• Title/Summary/Keyword: plant facilities

Search Result 936, Processing Time 0.03 seconds

Effects of Pipe Network Composition and Length on Power Plant Waste Heat Utilization System Performance for Large-scale Horticulture Facilities (발전소 온배수를 적용한 대규모 시설원예단지용 난방시스템의 열원이송 배관 재질 및 거리에 따른 성능평가)

  • Lee, Keum ho;Lee, Jae Ho;Lee, Kwang Ho
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.11 no.4
    • /
    • pp.14-21
    • /
    • 2015
  • Korean government plans to establish large-scale horticulture facility complexes using reclaimed land in order to improve the national competitiveness of agriculture at the government level. One of the most significant problems arising from the establishment of those large-scale horticulture facilities is that these facilities still largely depend on a fossil fuel and they require 24 h a day heating during the winter season in order to provide the necessary breeding conditions for greenhouse crops. These facilities show large energy consumption due to the use of coverings with large heat transmission coefficients such as vinyl and glass during heating in the winter season. This study investigated the applicability of waste heat from power plant for large-scale horticulture facilities by evaluating the waste heat water temperature, heat loss and energy saving performance as a function of distance between power plant and greenhouse. As a result, utilizing power plant waste heat can reduce the energy consumption by around 85% compared to the conventional gas boiler, regardless of the distance between power plant and greenhouse.

Development of Requirement Taxonomy for Design Bases Management during NPP lifecycle (원전 생애주기간 설계기준 정보관리를 위한 요건 분류체계 개발)

  • Kim, Jong-Myeong
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.11a
    • /
    • pp.134-135
    • /
    • 2018
  • Nuclear Power Plant consists of about 1.4 million facilities. and the design standards and design requirements for the continuos utilization and safety of facilities are complexly connected with the facilities. When a design change for facilities or design requirements is occurred at the time of construction or operation, there are a lot of facilities, design requirements, and design bases that are affected by the facilities or design bases being changed. The above design changes are so complex that the existing document-bases design change process is time-consuming and may also cause human error. In this study, we developed a design requirement taxonomy that can be applied to the data-centric design bases document that can improve it. To do this, we analyze the design elements from the highest level to the lowest level applied to the nuclear power plant, and classify the design elements according to the characteristics of the design elements.

  • PDF

SPSF : Smart Plant Safety Framework based on Reliable-Secure USN (차세대 USN기반의 스마트 플랜트안전 프레임워크 개발)

  • Jung, Ji-Eun;Song, Byung-Hun;Lee, Hyung-Su
    • Journal of The Institute of Information and Telecommunication Facilities Engineering
    • /
    • v.9 no.3
    • /
    • pp.102-106
    • /
    • 2010
  • Recently process industries from oil and gas procedures and mining companies to manufactures of chemicals, foods, and beverages has been exploring the USN (Ubiquitous Sensor Networks) technology to improve safety of production processes. However, to apply the USN technology in the large-scale plant industry, reliability and security issues are not fully addressed yet, and the absence of the industrial sensor networking standard causes a compatibility problem with legacy equipment and systems. Although this situation, process industry such as energy plants are looking for the secure wireless plant solution to provide detailed, accurate safety monitoring from previously hard-reach, unaccordable area. In this paper, SPSF (Smart Plant Safety Framework based on Reliable-Secure USN) is suggested to fulfill the requirements of high-risk industrial environments for highly secure, reliable data collection and plant monitoring that is resistant to interference. The SPSF consists of three main layers: 1) Smart Safety Sensing Layer, 2) Smart Safety Network Layers, 3) Plant Network System Layer.

  • PDF

A Study on Architectural Form of Waste to Energy Plants in accordance with Law - Focus on Seoul and Tokyo - (법규에 따른 자원회수시설의 건축적 형태에 관한 연구 - 서울과 도쿄를 중심으로 -)

  • Jung, Seung-won;Lee, Kang-jun
    • Journal of Urban Science
    • /
    • v.11 no.1
    • /
    • pp.29-35
    • /
    • 2022
  • Waste to Energy Plant were recognized as hateful facilities, and there were many conflicts in the location due to social problems such as the NIMBY phenomenon due to problems such as damage to property in the surrounding area, odor, and image loss. Problems such as air pollution and odor are solved by the development of advanced prevention facilities such as electric dust collectors, wet cleaning systems, semi-dry reaction towers, bag filters, and catalyst towers (SCR: Selective Catalytic Reduction), and air recycling facilities in waste storage tanks. However, it is being avoided because of the perception that it is an incinerator. To resolve these conflicts, the government installs and operates resident convenience facilities to compensate residents near resource recovery facilities, provides green space and improves the environment, and supports heating expenses in accordance with the 「Waste Treatment Facility Support Act」. The purpose of this study is to derive implications through the analysis of domestic and overseas case studies for resident convenience facilities and environment improvement for the promotion of local communities in resource recovery facilities and use them as basic data for community promotion and environmental improvement when installing resource recovery facilities in the future.

Efficiency Calculation of Operating Induction Motors in Plant (플랜트에서 운전 중인 유도전동기의 효율 계산)

  • Park, Hyung-Joon;Chung, Chan-Soo;Lee, Hae-Soo;Lee, Sang-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.2046-2047
    • /
    • 2007
  • This paper is about the energy efficiency calculation of operating electric motors in production facilities. The most important 1st step to efficient operation of plants is the evaluation of the energy efficiency of the production facilities in that plant. Through this procedure, we can decide that which facilities i.e. induction motors, in this paper, should do maintenance or not. There are mainly 2 types of energy which are used in production facilities, the one is electric energy and the other is heat energy but in order to make calculation simple, in this paper, we are only focusing on electric energy, efficiency and energy loss of the electric motors under operation conditions. As a case study, we chose electric motors in a certain process in a production facilities, and calculated efficiency and loss by using measured data.

  • PDF

A Study of the Sectionalizing for Pipe Deterioration Evaluation in Industrial Facilities (산업시설 배관 노후도 평가를 위한 배관 섹션화 방안 연구)

  • Min, Hyuk-Ki;Kim, Sang-Bum;Kim, Byung-Woo;Kim, Hyoung-Ki;Park, Yool
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.2
    • /
    • pp.103-111
    • /
    • 2015
  • In general, no particularly well-established standards have been in place so far, for the method of evaluating the deteriorated level of pipes and ducts of industrial facilities. For that reason, the evaluation depends upon various studies which are based on the analysis of the residual life, thickness thinning, closure rate, and scale thickness that measure a few specific positions of pipes. It also depends upon the expertise in business operation and the specific techniques conducted by the inspection companies and institutions. This research introduces the concept of measuring units per section and the selection method of measurement points per section. Furthermore, specific methodologies were developed to plan and analyze deterioration level of industrial pipes and ducts by engineers and managers using a section map. Consequently, applying the outcomes from this study to the plant equipment of the incineration facility resulted in saving 42% of the repairing and remodeling cost.

A Study on the Utilization of QR Code for Improving the Effectiveness of Safety Education in Power Plant Workplaces (발전소 사업장의 안전교육 효과성 향상을 위한 QR Code 활용방안 연구)

  • Oh, Myeong-Geun;Kim, Young-Kook;Jeong, Kyung-Ok
    • Journal of the Korea Safety Management & Science
    • /
    • v.24 no.2
    • /
    • pp.33-39
    • /
    • 2022
  • In order to improve the implementation of safety and health education at the site for industrial accident prevention activities, research was conducted to minimize inconvenience and increase utilization by redesigning and developing existing education methods. To date, occupational safety and health education has been conducted without considering the general work characteristics and functional facilities (mechanical, electrical, instrumentation, chemical) of workers (mechanical: turbine, valve, pump, hydraulic system, electrical: generator, breaker, motor, etc.). In particular, plant facilities were classified as mechanical and electrical facilities to improve the methodology for industrial safety and health education for plant maintenance workers. In addition, the "One Page Education Plan" was announced as a learning case because the spread of COVID-19 infectious diseases made it impossible to reduce or control the number of people in all groups and groups. The improvement of this training method will play a major role in improving the effectiveness of safety education in power plant workplaces.

Analysis of Reliability Variation Affected by the Newly Installed Experimental Facilities in the HANARO Research Reactor (신규 실험설비 운전으로 인한 하나로 연구용 원자로의 운영 신뢰도 변화 분석)

  • Jung, Hoan-Sung;Lim, In-Cheol
    • Journal of Applied Reliability
    • /
    • v.10 no.1
    • /
    • pp.57-64
    • /
    • 2010
  • The HANARO nuclear research reactor had been operated successfully and smoothly up to the year 2008 since its first year of instability in year 1995 just after the completion of construction. But the reliability of the reactor has been degraded from the year 2009 due to new experimental facilities such as Feul Test Loop(FTL) and Cold Neutron Source(CNS) which were installed in the HANARO plant. It turned out that these new facilities contributed unexpected stoppage of the plant. This paper describes causes of stoppage and suggestions to improve the reliability of the plant.

Establishment of Field Robot System for Surveillance of Power Plant Facilities (발전 설비 감시.점검용 필드로봇 시스템 구축)

  • Lee, Jae-Kyung;Park, Joon-Young;Cho, Byung-Hak;Jeong, Chang-Ki
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.1077-1078
    • /
    • 2008
  • As power plant facilities are being deteriorated, their safety is getting more importance, and more routine surveillance is being required. For this purpose, this paper presents a field robot system which performs the surveillance of power plant facilities instead of human workers from the viewpoint of the workers' safety and work efficiency.

  • PDF

Indoor Localization System for Field Robot System of Power Plant Facilities Surveillance (발전 설비 감시 점검용 로봇 시스템을 위한 실내 위치 인식 시스템 설계)

  • Jeong, Chang-Ki;Lee, Jae-Kyung;Park, Joon-Young;Cho, Byung-Hak
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1559-1560
    • /
    • 2008
  • As power plant facilities are being deteriorated, their safety is getting more importance, and more routine surveillance is being required. For this purpose, this paper presents an indoor localization system for field robot system which performs the surveillance of power plant facilities instead of human workers from the viewpoint of the workers' safety and work efficiency.

  • PDF