• Title/Summary/Keyword: placement of analog

Search Result 17, Processing Time 0.02 seconds

The Effect of Clarified Mapping Strategy and Placement of Analog on Middle School Students' Conceptual Understanding in Science (대응 명료화 전략 및 비유물의 제시 시기가 중학생들의 과학 개념 이해에 미치는 효과)

  • Noh, Tae-Hee;Kim, Chang-Min;Kwon, Hyeok-Soon
    • Journal of The Korean Association For Science Education
    • /
    • v.19 no.1
    • /
    • pp.107-116
    • /
    • 1999
  • The effects of clarified mapping strategy and placement of analog on middle school students' conceptual understanding were investigated. According to the usage of clarified mapping strategy and the sequence in presenting analogy, four types of learning materials were developed and pilot tested. Prior to the treatment, the field dependence-independence test was administered and a previous achievement test scores were obtained. The scores were used as blocking variables. The learning materials were read by randomly assigned middle school students (N=111), and the conceptions test was administered immediately and four weeks later. In the recall problems of immediate and retention test, there were no significant differences. In the application problems of immediate and retention test, however, the students learned with clarified mapping strategy scored significantly higher than those with analog-only. Field-independent students learned with clarified mapping strategy scored significantly higher in the immediate application than those with analog-only, and higher-level students learned with clarified mapping strategy scored significantly higher in the retention application than those with analog-only. In the immediate application, higher-level students learned analog first with clarified mapping strategy scored significantly higher in the immediate application than those learned target concept first with clarified mapping strategy. However, lower-level students learned target concept first with clarified mapping strategy scored significantly higher than those learned analog first with clarified mapping strategy.

  • PDF

Specification-based Analog and Mixed-signal Circuits Test with Minimal Built-In Hardware Overhead (내장 하드웨어 오버헤드를 최소화한 Specification 기반의 아날로그 및 혼합신호 회로 테스트)

  • Lee, Jae-Min
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.633-634
    • /
    • 2006
  • A new specification-based analog and mixed-signal test technique using high performance current sensors is proposed. The proposed technique using current sensors built in external ATE has little hardware overhead in circuit under test and high testability without time consuming operation of test point placement algorithm.

  • PDF

A prospective study of fully covered self-expandable metal stents for refractory benign pancreatic duct strictures

  • Bhavik Bharat Shah;Gajanan Ashokrao Rodge;Usha Goenka;Shivaraj Afzalpurkar;Mahesh Kumar Goenka
    • Clinical Endoscopy
    • /
    • v.55 no.6
    • /
    • pp.793-800
    • /
    • 2022
  • Background/Aims: Fully covered self-expanding metal stents (FCSEMSs) are a relatively novel option for treating painful main pancreatic duct refractory strictures in patients with chronic pancreatitis. Herein, we aimed to assess the efficacy, feasibility, and safety of FCSEMSs in this patient group. Methods: This prospective single-center study included patients who underwent endoscopic retrograde pancreatography with FCSEMS placement. The primary endpoints were the technical and clinical success rates. A reduction in visual analog scale pain score of >50% compared with that before stent placement was defined as clinical success. Secondary endpoints were resolution of pancreatic strictures on fluoroscopy during endoscopic retrograde pancreatography and the development of stent-related adverse events. Results: Thirty-six patients were included in the analysis. The technical success rate was 100% (n=36) and the clinical success rate was 86.1% (n=31). There was a significant increase in stricture diameter from 1.7 mm to 3.5 mm (p<0.001) after stent removal. The mean visual analog scale pain score showed statistically significant improvement. At 19 months of follow-up, 55.6% of the patients were asymptomatic. Stent migration (16.7%), intolerable abdominal pain (8.3%), development of de novo strictures (8.3%), and mild pancreatitis (2.8%) were the most common adverse events. Conclusions: FCSEMS placement showed good technical and clinical success rates for achieving pain relief in patients with refractory main pancreatic duct strictures.

Esthetic reconstruction of upper central incisor using immediate Frialit-2 implant placement, immediate temporary crown fabrication and IPS Empress 2 crown (즉시 Frialit-2 implant 식립, 즉시 임시치관 제작 그리고 IPS Empress 2 crown을 이용한 상악중절치의 심미적 수복)

  • Kim, Yu-Lee;Oh, Sang-Chun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.19 no.1
    • /
    • pp.43-48
    • /
    • 2003
  • During the past several years, significant advances have occurred in the utilization of osseointegrated implants for the treatment of partially edentulous patients. One of the biggest purposes for treating of these patients is the high demand for improved esthetics, especially in the anterior region. For this esthetics, the new trend in dental implants is the immediate placement and immediate superstructure fabrication. The refined surgical technique, the skillful soft tissue management, and the proper prosthetic coordination are the main factors to achieve natural looking of implant supported prosthesis. The customized provisional restoration and the customized impression coping are recommended for the optimal peri-implant soft tissue contour. The basic concept of Frialit 2 system was the immediate replacement of a tooth with root-analog fixture after extraction. This system guarantees an ideal result in function and esthetics. The ceramic abutment system offers improved quality in the respect of esthetics, fitness, translucency, and biocompatibility. In this clinical report, the final restoration made with IPS Empress 2 crown on the CeraBase abutmen of Frialit 2 system allowed the reproduction of the natural vitality of tooth and adjacent gingiva.

Effect of a 5% naproxen patch on reducing pain caused by separators prior to fixed orthodontic treatment

  • Eslamian, Ladan;Rad, Nazila Akbarian;Nobar, Behnam Rahbani;Mortazavi, Seyed Alireza
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.18 no.3
    • /
    • pp.151-159
    • /
    • 2018
  • Background: The pain involved in orthodontic treatments may involve inflammatory processes. This study evaluated the effect of using a naproxen patch for pain reduction in the separating stage of fixed orthodontic treatment. Methods: In this double-blind, randomized, controlled clinical trial of 35 orthodontic patients (age: 14-19 years) who had pain during separator placement, each patient randomly placed naproxen and placebo patches in the first permanent molar region, in opposite quadrants of the same jaw. Patches were replaced every 8 hours until 3 days after separator placement. Patients recorded their pain perception at 2, 6, and 24 hours, and on days 2 (6 PM), 3 (10 AM and 6 PM), and 7 (10 AM and 6 PM), using a visual analog scale. Mean pain scores were compared for the two patches, and effects of sex and age thereon determined. Results: Data from 29 patients (21 girls, eight boys) were analyzed. Mean pain values decreased over time for both patches (P < 0.001). Recorded pain did not differ significantly between the sexes (P = 0.059) or between those aged <16 and those ${\geq}16years$ (P = 0.106). Mean pain recorded with naproxen patches was statistically significantly less than that with placebo patches at all time points (P = 0.004). Conclusion: The naproxen patch was more efficient than the placebo patch for reducing pain at all time points. The highest pain score was recorded at 6 hours, and the least pain was recorded at the $7^{th}$ day after separator placement.

Orthodontic pain control following arch wire placement; a comparison between pre-emptive tenoxicam and chewing gum: a randomized clinical trial

  • Basam, Lakshman Chowdary;Singaraju, Gowri Sankar;Obili, Sobitha;Keerthipati, Thejasree;Basam, Ram Chowdary;Prasad, Mandava
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.22 no.2
    • /
    • pp.107-116
    • /
    • 2022
  • Background: Pain during fixed orthodontic treatment can have a detrimental effect on patient treatment compliance. To overcome this, there is a definite need to establish the best pain-relieving methods suitable for orthodontic patients in terms of efficacy and use. The objective of this study was to compare the effect of chewing gum and pre-emptive tenoxicam on pain after initial archwire placement and to evaluate the pain perceptions of orthodontic patients in the two groups while performing various functions at specific time intervals. Methods: Forty-two patients were selected and randomly divided into two groups: group A (chewing gum) and group B (pre-emptive tenoxicam). Pain perception was documented by patients immediately; at 4 h; at bedtime on the day of archwire placement; the next morning; at 24 h; and at bedtime on the 2nd, 3rd, and 7th day after the initial archwire placement. Pain scores were noted during fitting of the posterior teeth, biting, and chewing using a visual analog scale. The data obtained were subjected to statistical analysis. Results: Group A showed a significant increase in pain until the next morning while fitting the posterior teeth, biting, and chewing [36.2, 52.0, 33.4, respectively]], followed by a gradual decrease by the 7th day. Group B showed a significant increase in pain at bedtime on biting, with a peak value of 47.5. Pain on chewing, fitting posterior teeth, peaked the morning of the next day (100.0, 45.0). The Freidman test showed a statistically significant difference with a p-value of < 0.01. Higher pain scores were observed while chewing and biting compared with that while fitting the posterior teeth in both groups. The overall comparison of pain control between the two groups was not statistically significant [P > 0.05] between the two groups. Conclusions: Chewing gum was not inferior to pre-emptive tenoxicam. Thus, chewing gum is a non-pharmacological alternative to analgesics for orthodontic pain control that eliminates the chance of adverse reactions and can be used in the absence of adult observation.

Chewing gum as a non-pharmacological alternative for orthodontic pain relief: A randomized clinical trial using an intention-to-treat analysis

  • da Silva Santos, Diego Junior;Capelli, Jonas Jr.
    • The korean journal of orthodontics
    • /
    • v.51 no.5
    • /
    • pp.346-354
    • /
    • 2021
  • Objective: To compare the effectiveness of ibuprofen, acetaminophen, and chewing gum for orthodontic pain relief and to assess if chewing gum can be a non-pharmacological alternative for orthodontic pain relief. Methods: The study enrolled 106 patients of both sexes, aged ≥ 12 years, with body weight > 50 kg, and mild-to-moderate dental crowding in the upper arch. After randomization and allocation concealment, the intervention groups were either administered with ibuprofen (400 mg) or acetaminophen (500 mg) or chewed sugar-free chewing gum immediately after initial archwire placement and every 6 hours for 1 week if the pain persisted. The control group did not receive any pain relief. The pain was assessed on a 100-mm visual analog scale at rest and while biting down at T1 (2 hours), T2 (24 hours), T3 (2 days), T4 (3 days), T5 (7 days), and T6 (21 days). Statistical analyses were performed using the Kruskal-Wallis and post-hoc Mann-Whitney U tests (α = 0.05). Results: The chewing gum group experienced more pain relief than the ibuprofen group at while biting down at T3 (p = 0.04) and at rest at T4 (p < 0.001). The chewing gum group reported more pain relief than the acetaminophen and control groups while biting down at T3 (p = 0.03 and p = 0.0006, respectively) and T4 (both p < 0.001). Conclusions: Chewing gum can be a non-pharmacological alternative for orthodontic pain relief at 2 and 3 days after initial archwire placement.

Comparison Study with Pain Assessment Tools of Pain Measurement in Children for Intravenous Catheter Placement in the Computed Tomography (CT 검사에서 소아 환자의 정맥 카데터 삽입 통증에 대한 측정 도구 비교)

  • Kweon, Dae-Cheol;Jang, Keun-Jo
    • The Journal of the Korea Contents Association
    • /
    • v.8 no.2
    • /
    • pp.205-212
    • /
    • 2008
  • Needle phobia of medical devices is a significant problem in children patients. We conducted study in 130 pediatric patients aged $8{\sim}13$(mean age 10.5) who had venipuncture performed in a computed tomography. This review aims to explore the research available relating to three commonly used pain rating scales of children, the visual analogue scale(VAS), numeric pain rating scale(NPRS) and Wong-Baker faces pain scale(WBFPS) with scores. Its validity is supported by a strong positive correlation with the three-pain rating scales(correlations ranging from 0.70 to 0.92) measure in children. There were no significant differences between the means on the VAS and either of the pain rating scales. It has the advantage of being suitable for use with the most widely used metric for scoring($0{\sim}10$), and conforms closely to a linear interval scale. These scales presented moderate to good correlation and moderate agreement, sufficient for valid use in children. All three pain-rating scales are valid, reliable and appropriate for use in intravenous catheter placement.

Ultrasound-guided Pulsed Radiofrequency Lesioning of the Ulnar Nerve in a Patient with Cubital Tunnel Syndrome -A case report- (팔꿉굴증후군 환자에서 초음파를 이용한 척골신경의 박동성고 주파술의 경험 -증례보고-)

  • Ghil, Bo-Gyoung;Kil, Ho-Yeong
    • The Korean Journal of Pain
    • /
    • v.21 no.3
    • /
    • pp.224-228
    • /
    • 2008
  • Ulnar nerve compression in the cubital tunnel is a common entrapment syndrome of the upper limb. Pulsed radiofrequency lesioning (PRFL) has been reported as a treatment method for relieving neuropathic pain. Since the placement of the electrode in close proximity to a targeted nerve is very important for the success of PRFL, ultrasound seems to be well suited for this technique. A 36-year-old woman presented with complaints of numbness and pain on the medial aspect of the elbow and the pain radiated down to the $4^{th}$ and $5^{th}$ fingers for 10 years after she suffered an elbow contusion, we then scheduled this woman for the ultrasound guided PRFL of the ulanr nerve. The initial ultrasound examination demonstrated a swollen nerve, loss of the fascicular pattern and an increased cross sectional area of the ulnar nerve. After confirmation of the most swollen site of the nerve via ultrasound, two sessions of PRFL were performed. The postprocedural 10 cm visual analog scale score decreased from 8 to 1 after the two sessions of PRFL.

A Study on the Position Control of an Electro-Hydraulic Servomechanism Using Variable Structure System (가변구조를 이용한 전기-유압서보계의 위치제어에 관한 연구)

  • 허준영;권기수;하석홍;조겸래;이진걸
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.2
    • /
    • pp.213-220
    • /
    • 1989
  • This paper describes the application of the variable structure control(VSC) concept for the position control of an electro-hydraulic servomotor system. The basic philosopy of VSC is that the structure of the feedback control is altered as the state crosses discontinuity surfaces in the state space with the result that certain desirable properties are achieved. The switching of the control function yields total(or selective) invariance to system parameter variations and disturbances, and closed loop eigen value placement in time-varing and uncertain systems. The control scheme is derived, implemented and tested in the laboratory where analog controller have been used to control the representive servosystem. The control system schematics are given and simple results are shown for illustration. And the results of variable structure system for the electro-hydraulic servomotor were compared to that of the fixed structure system when load disturbance and system parameter variation exists.