• Title/Summary/Keyword: pitch production

Search Result 185, Processing Time 0.022 seconds

Study of Production and Material Properties of Micro Screw Using SWCH18A and SUS XM7 Materials (SWCH18A 와 SUS XM7 을 적용한 초소형 나사제작 및 물성분석에 관한 연구)

  • Ra, Seung-Woo;Kim, In-Rak;Hwang, Sung Tack
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.9
    • /
    • pp.1043-1048
    • /
    • 2014
  • As micro screws feature reduced screw lengths and pitches, the resulting clamping force diminishes because of the reduced length of the actual joints. The elements of the clamping force are material, geometry, and friction. We studied the shrinking size of the screw and the methods to improve the clamping force by changing the material. We developed a micro screw using SWCH18A and SUS XM7 materials, and obtained the precision and thickness of the pitch through three-dimensional measurement. We also measured the external resistance of the micro screw by applying the Vicker's hardness test and conducted a break surface analysis using a break torque test and SEM for obtaining the break characteristics.

Classification of Porcine Wasting Diseases Using Sound Analysis

  • Gutierrez, W.M.;Kim, S.;Kim, D.H.;Yeon, S.C.;Chang, H.H.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.23 no.8
    • /
    • pp.1096-1104
    • /
    • 2010
  • This bio-acoustic study was aimed at classifying the different porcine wasting diseases through sound analysis with emphasis given to differences in the acoustic footprints of coughs in porcine circo virus type 2 (PCV2), porcine reproductive and respiratory syndrome (PRRS) virus and Mycoplasma hyopneumoniae (MH) - infected pigs from a normal cough. A total of 36 pigs (Yorkshire${\times}$Landrace${\times}$Duroc) with average weight ranging between 25-30 kg were studied, and blood samples of the suspected infected pigs were collected and subjected to serological analysis to determine PCV2, PRRS and MH. Sounds emitted by coughing pigs were recorded individually for 30 minutes depending on cough attacks by a digital camcorder placed within a meter distance from the animal. Recorded signals were digitalized in a PC using the Cool Edit Program, classified through labeling method, and analyzed by one-way analysis of variance and discriminant analysis. Input features after classification showed that normal cough had the highest pitch level compared to other infectious diseases (p<0.002) but not statistically different from PRRS and MH. PCV2 differed statistically (p<0.002) from the normal cough and PRRS but not from MH. MH had the highest intensity and all coughs differed statistically from each other (p<0.0001). PCV2 was statistically different from others (p<0.0001) in formants 1, 2, 3 and 4. There was no statistical difference in duration between different porcine diseases and the normal cough (p>0.6863). Mechanisms of cough sound creation in the airway could be used to explain these observed acoustic differences and these findings indicated that the existence of acoustically different cough patterns depend on causes or the animals' respiratory system conditions. Conclusively, differences in the status of lungs results in different cough sounds. Finally, this study could be useful in supporting an early detection method based on the on-line cough counter algorithm for the initial diagnosis of sick animals in breeding farms.

Turret location impact on global performance of a thruster-assisted turret-moored FPSO

  • Kim, S.W.;Kim, M.H.;Kang, H.Y.
    • Ocean Systems Engineering
    • /
    • v.6 no.3
    • /
    • pp.265-287
    • /
    • 2016
  • The change of the global performance of a turret-moored FPSO (Floating Production Storage Offloading) with DP (Dynamic Positioning) control is simulated, analyzed, and compared for two different internal turret location cases; bow and midship. Both collinear and non-collinear 100-yr GOM (Gulf of Mexico) storm environments and three cases (mooring-only, with DP position control, with DP position+heading control) are considered. The horizontal trajectory, 6DOF (degree of freedom) motions, fairlead mooring and riser tension, and fuel consumptions are compared. The PID (Proportional-Integral-Derivative) controller based on LQR (linear quadratic regulator) theory and the thrust-allocation algorithm which is based on the penalty optimization theory are implemented in the fully-coupled time-domain hull-mooring-riser-DP simulation program. Both in collinear and non-collinear 100-yr WWC (wind-wave-current) environments, the advantage of mid-ship turret is demonstrated by the significant reduction in heave at the turret location due to the minimal coupling with pitch mode, which is beneficial to mooring and riser design. However, in the non-collinear WWC environment, the mid-turret case exhibits unfavorable weathervaning characteristics, which can be reduced by employing DP position and heading controls as demonstrated in the present case studies. The present study also reveals the plausible cause of the failure of mid-turret Gryphon Alpha FPSO in milder environment than its survival condition.

The comparative Study of the Acoustic Representation between Pansori singer's and Spasmodic dysphonia patient's Voice (병적인 소리 떨림증과 소리꾼 떨림증의 음향학적인 비교연구)

  • Hong, K.H.;Kim, H.G.;Lee, J.K.;Choi, J.S.
    • Proceedings of the KSPS conference
    • /
    • 2007.05a
    • /
    • pp.143-145
    • /
    • 2007
  • Muscle groups that are located in and around the vocal tract can produce audible changes in frequency and/or intensity of the voice. Vocal vibrato is a characteristic feature in the singing of performers trained in the western classical tradition and vibrato is generally considered to result from modulation in frequency amplitude and timbre. Vocal tremor is also characterized by periodic fluctuations in the voice frequency or intensity and vocal tremor is symptom of a neurological disease as Spasmodic dysphonia , Parkinson's disease. Vocal vibrato and Vocal tremor may have many of the same origins and mechanisms in the voice production systems. The purpose of this study is to find acostic character of Korean traditional song Pansori singer's vibrato and Spasmodic dysphonia patient's vocal tremor. twelve Pansori singers and seven Spasmodic dysponia patients participated to this study. Power spectrum and Real time Spectrogram are used to analyze the acoustic characteristics of Pansori singing and Spasmodic dysphonia patient's voice The results are as follows; First, vowel formant differences between Pansori singing and Spasmodic dysphonia patient's voice are higher F1, F3. Second, The vibrato rate show differences between Pansori singing and Spasmodic dysphonia patients;$4^{\sim}6/sec$ and $5{\sim}6/sec$ Vibrato rate of pitch is 5.7 Hz ${\sim}$ 42.4 Hz for Pansori singing , 3.8 Hz ${\sim}$ 27.9 Hz for Spasmodic dysphonia patients ;Vibrato rate of intensity range is 0.07 dB ${\sim}$ 8.26 dB for Pansori singing and 0.07 dB ${\sim}$ 4.81 dB for Spasmodic dysphonia patients

  • PDF

The First Formant Characteristics in Vocalize of One Soprano (소프라노 1인의 모음곡 발성 시 제 1 포먼트의 변화양상)

  • Song, Yun-Kyung;Jin, Sung-Min
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.16 no.1
    • /
    • pp.10-14
    • /
    • 2005
  • Background and Objectives : Vowels are characterized on the basis of formant patterns. The first formant(F1) is determined by high-low placement of the tongue, and the second formant (F2) by front-back placement of the tongue. The fundamental frequency(F0) of a soprano often exceed the normal frequency of the first formant. And the vocal intensity is boosted when F0 is high and a harmonic coincides with a formant. This is called a formant tuning. Experienced singers thus learned how to tune their formants over a resonable range by lowering the tongue to maximize their vocal intensity. So, the current study aimed to identify the formant tuning in one experienced soprano by comparing the first formants of vowel [i] in three different voice production : speech, ascending scale, and vocalize. Materials and Method : All voices recordings of vowel [i] in speech, ascending scale (from F4 note to A4 note), and vocalize(:Ridente la calam") were made with digital audio tape-corder in a sound treated room. And the captured data were analyzed by the long term average(LTA) power spectrum using the FFT algorithm of the Computerized Speech Lab(CSL, Kay elementrics, Model, 4300B). Results : Although the first formant of vowel [i] in speech was 238Hz, those of ascending scale [i] were 377Hz, 405Hz, 453Hz respectively in F4(349z), G4(392Hz), A4(440Hz) note, and 722Hz, 820Hz, 918Hz respectively in F5 (698Hz), G5(784Hz), A5(880Hz) note. In vocalize, first formants of [i] were 380Hz, 398Hz, 453Hz respectively in F4, G4, A4 note, and 720Hz, 821Hz, 890Hz respectively in F5, G5, A5 note. Conclusion : These results showed that the first formant of ascending scale and vocalize sustained higher frequency than fundamental frequency in high pitch. This finding implicates that the formant tuning of vowel [i] in ascending scale was also noted in vocalize.

  • PDF

Studies on the Manufacturing of Carbon Bond Graphite Crucible (카아본 본드형 흑연 도가니 제조에 관한 연구)

  • 김충일;김문수
    • Journal of the Korean Ceramic Society
    • /
    • v.13 no.1
    • /
    • pp.11-19
    • /
    • 1976
  • This study was focused on the improvement of production techniques of small crucibles in relation with the appropriate selection of raw materials, various batch compositions and physical and chemical characteristics of the crucibles. Various tests gave the optimum batch composition for the carbon bond graphite cructble as follows: Pyontaek graphite flake (refractory aggregate) : 40Part Silicon carbide: 15Part Tar pitch (binder) : 11Part Inorganic additives (to improve the oxidation resistance) : 15 Part Cryolite : 3 Part Ferro manganese : 2 Part Ferrosilicon : 25 Part Crucibles pressed with 400kg/$\textrm{cm}^2$ at 12$0^{\circ}C$. and fired in reducing atmosphere at 120$0^{\circ}C$ brought the most favorable results as follows: Bulk density : 2.31 Apparent density : 2.58 Porosity : 15.2% Oxidation loss at 1, 50$0^{\circ}C$. for 3 hrs : below 3.77% Water absorption : 6.01% Compressive strength : 438kg/$\textrm{cm}^2$ Tensile strength : 256kg/$\textrm{cm}^2$.

  • PDF

On-line Surface Defect Detection using Spatial Filtering Method (공간필터법을 이용한 온라인 표면결함 계측)

  • Moon, Serng-Bae;Jun, Seung-Hwan
    • Journal of Navigation and Port Research
    • /
    • v.28 no.1
    • /
    • pp.43-49
    • /
    • 2004
  • Defects inspection of commodities are very important with those design and manufacturing process and essential to strengthen the competitiveness of those. If on-line automatic defects detection is performed without damaging to products, the production cost shall be curtailed through the reducing man-power, economical management of Q.C(Quality Control). In this paper, it is suggested three spatial filtering methods which can extract the necessary information in case of defects being on the surface of object like iron plate. In addition, the dependence of filtering characteristics on parameters such as the pitch and width of slits is analyzed and the surface defect detection system is constructed. Several experiments were carried out for determining the adequate spatial filtering method through comparing and analyzing effects of parameters like defect's size and shape, intensity of light, noise of coherent source and slit number.

Realization of 3D Image on Metal Plate by Optimizing Machining Conditions of Ultra-Precision End-Milling (초정밀 엔드밀링 가공조건 최적화를 통한 금속상의 3차원 이미지 구현)

  • Lee, Je-Ryung;Moon, Seung Hwan;Je, Tae-Jin;Jeong, Jun-Ho;Kim, Hwi;Jeon, Eun-chae
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.11
    • /
    • pp.885-891
    • /
    • 2016
  • 3D images are generally manufactured by complex production processes. We suggested a simple method to make 3D images based on a mechanical machining technology in this study. We designed a tetrahedron consisted of many arcs having the depth of $100{\mu}m$ and the pitch of $500{\mu}m$, and machined them on an aluminum plate using end-milling under several conditions of feed-rate and depth of cut. The area of undeformed chip including depth of cut and feed-rate can predict quality of the machined arcs more precisely than the undeformed chip thickness including only feed rate. Moreover, a diamond tool can improve the quality than a CBN tool when many arcs are machined. Based on the analysis, the designed tetrahedron having many arcs was machined with no burr, and it showed different images when observed from the left and right directions. Therefore, it is verified that a 3D image can be designed and manufactured on a metal plate by end-milling under optimized machining conditions.

Analysis and Experiments on the Thread Rolling Process for Micro-Sized Screws Part I: Process Parameter Analysis by Finite-Element Simulation (마이크로 체결부품 전조성형공정에 관한 해석 및 실험적 고찰(Part I: 유한요소 해석기반 공정변수 영향분석))

  • Song, J.H.;Lee, J.;Lee, H.J.;Lee, G.A.;Park, K.D.;Ra, S.W.;Lee, H.W.
    • Transactions of Materials Processing
    • /
    • v.20 no.8
    • /
    • pp.581-587
    • /
    • 2011
  • The production of high-precision micro-sized screws, used to fasten parts of micro devices, generally utilizes a cold thread-rolling process and two flat dies to create the teeth. The process is fairly complex, involving parameters such as die shape, die alignment, and other process variables. Thus, up-front finite-element(FE) simulation is often used in the system design procedure. The final goal of this paper is to produce high-precision screw with a diameter of $800{\mu}m$ and a thread pitch of $200{\mu}m$ (M0.8${\times}$P0.2) by a cold thread rolling process. Part I is a first-stage effort, in which FE simulation is used to establish process parameters for thread rolling to produce micro-sized screws with M1.4${\times}$P0.3, which is larger than the ultimate target screw. The material hardening model was first determined through mechanical testing. Numerical simulations were then performed to find the effects of such process parameters as friction between work piece and dies, alignment between dies and material. The final shape and dimensions predicted by simulation were compared with experimental observation.

Acoustic Analysis of Normal and Vocal Pathologic Voice Using Dr. Speech Science (Dr. Speech Science를 이용한 정상 및 후두질환 환자의 음향분석)

  • Lee, Hyung-Seok;Tae, Kyung;Jang, Kyung-Jin;Kim, Kyung-Woo;Kim, Kyung-Rae;Park, Chul-Won
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.8 no.2
    • /
    • pp.166-172
    • /
    • 1997
  • Background : For example, aerodynamic study, vibratory study, acoustic study, neuro-muscular test and psychoacoustic evaluation, a number of objective methods are now available for assessing pathologic voice change. They help to differentiate pathologic condition from normal condition and to monitor pathologic and aging change. These laboratory analyses are used commonly to monitor speech therapy and to follow a patient's recovery after surgery. Objectives : We investigated the values of jitter, shimmer and NNE of normal person and hoarseness patients in Korea. The values of Jitter and shimmer might be meaningful parameters distinguishing pathologic vibration from normal and recovery after surgery. Materials and Methods : Statistical significance between normal control and 48 subjects taken microlaryngeal surgery were compared with Dr. speech science program that is computerized system for acoustic analysis of voice production employed to determine vocal characteristics of pitch perturbation(jitter) and amplitude perturbation(shimmer). Results : The mean normal values of jitter and shimmer were 0.226${\pm}$0.110(%), 2.200${\pm}$0.421(%) in male and 0.164${\pm}$0.060(%), 2.063 ${\pm}$0.575(%) in female. In patients with vocal nodule, the preoperative and postoperative values of jitter and shimmer were valueless. In patients with vocal polyps, the preoperative and postoperative values of jitter and shimmer were valuable. Conclusion : Dr. speech science program was effective to monitor laryngeal disease and aging changes.

  • PDF