• Title/Summary/Keyword: pipet method

Search Result 6, Processing Time 0.021 seconds

Accuracy and Precision of Spectrophotometric Measurement of Clay Content in Soils (분광광도계를 이용한 점토함량 분석의 정확성 및 정밀성 평가)

  • Park, Soon-Nam;Kim, Kye-Hoon;Kang, Ji-Young
    • Applied Biological Chemistry
    • /
    • v.49 no.2
    • /
    • pp.153-157
    • /
    • 2006
  • Accuracy and precision of the spectrophotometeric analysis of clay content in soils were estimated by comparison with the conventional pipet method. Clay contents in 25 soil samples of various physico-chemical properties including texture were determined by spectrophotometry and pipet methods, and the two sets of data an clay content were compared by several statistical analyses. The correlation between clay contents determined by spectrophotometry and pipet methods was highly significant. The regression coefficient was $0.98^{**}$ and the slope of regression equation was close to 1.0. The standard deviation and CV of clay contents measured by spectorphotometry were smaller than those found in the data of clay contents obtained by pipet method. In conclusion, compared to the conventional pipet method, spectrophotometry was a rapid, convenient, accurate and precise method for the measurement of clay content in soils.

Use of Spectrophotometry for Quantitative Determination of Soil Clay Content (분광광도계를 이용한 점토함량 분석)

  • Park, Soon-Nam;Kim, Kye-Hoon;Kang, Ji-Young
    • Applied Biological Chemistry
    • /
    • v.48 no.2
    • /
    • pp.183-188
    • /
    • 2005
  • This study was conducted to develop a method for the quantitative determination of soil clay content by spectophotometry. The optimum wavelength obtained with reference clay minerals for spectrophotometry was 500 nm. For the proposed spectrophotometry, 0.5 g of soil sample was put in the 250 ml Erlenmeyer flask and 100 ml dispersing agent was added. After shaking the flask at 130 rpm with a mechanical shaker overnight, the flask was removed from the shaker and was shaken up-and-down for 30 seconds. With a micro-pipet, 4 ml of the suspension was transferred into the previously-inserted cell and the absorbance was measured instantly. Results by the spectrophotometry for clay content analysis were compared with those by the conventional sedimentation technique (the pipet method). The proposed equation was $y\;=\;38.03x_1-0.17x_2-1.17$, where y, $x_1$, and $x_2$ were clay content (%) by the pipet method, water content corrected clay content (%) by spectrophotometry, and organic matter content ($g{\cdot}kg^{-1}$), respectively. The regression coefficient for the equation was $r\;=\;0.984^{**}$, indicating highly significant correlation between the results of the two methods.

Development of a user-friendly training software for pharmacokinetic concepts and models

  • Han, Seunghoon;Lim, Byounghee;Lee, Hyemi;Bae, Soo Hyun
    • Translational and Clinical Pharmacology
    • /
    • v.26 no.4
    • /
    • pp.166-171
    • /
    • 2018
  • Although there are many commercially available training software programs for pharmacokinetics, they lack flexibility and convenience. In this study, we develop simulation software to facilitate pharmacokinetics education. General formulas for time courses of drug concentrations after single and multiple dosing were used to build source code that allows users to simulate situations tailored to their learning objectives. A mathematical relationship for a 1-compartment model was implemented in the form of differential equations. The concept of population pharmacokinetics was also taken into consideration for further applications. The source code was written using R. For the convenience of users, two types of software were developed: a web-based simulator and a standalone-type application. The application was built in the JAVA language. We used the JAVA/R Interface library and the 'eval()' method from JAVA for the R/JAVA interface. The final product has an input window that includes fields for parameter values, dosing regimen, and population pharmacokinetics options. When a simulation is performed, the resulting drug concentration time course is shown in the output window. The simulation results are obtained within 1 minute even if the population pharmacokinetics option is selected and many parameters are considered, and the user can therefore quickly learn a variety of situations. Such software is an excellent candidate for development as an open tool intended for wide use in Korea. Pharmacokinetics experts will be able to use this tool to teach various audiences, including undergraduates.

Ultrarapid Freezing of Biopsied Mouse Embryos at the 4-cell Stage (할구 한 개가 제거된 생쥐 4세포기 수정란의 초급속동결)

  • 강만종;이철상;한용만;유대열;이경광
    • Journal of Embryo Transfer
    • /
    • v.7 no.2
    • /
    • pp.81-88
    • /
    • 1992
  • Cryopreservation of mouse embryos biopsied at 4-cell stage was investigated by ultrarapid freezing. Four-cell embryos were obtained from ICR mice on 55h after hCG injection. Zona pellucida of the embryos were partially dissected with a cutting pipet, and then single blastomeres were biopsied from the embryos followed by incubation in $Ca^2$+ and $Mg^2$+-free M16 medium for 30min. Biopsied embryos cultured for lh or 15h were frozen by ultrarapid freezing method using 3M DMSO or 5M glycerol as a cryoprotectant, respectively. The developmental rate of biopsied embryos after ultrarapid freezing and thawing to blastocysts was 81 % in the group of biopsied embryos cultured for lb and 98% in the group of biopsied embryos cultured for 15h, respectively. When biopsied embryos after ultrarapid freezing and thawing were transferred to the uteri of pseudopregnant recipients, normal live young were born. These results suggest that this freezing method can efficiently cryopreserve biopsied mouse embryos.

  • PDF

Recommended Method for Radioisotope Red-Cell Survival Studies (방사성(放射性) 동위원소(同位元素)를 이용(利用)한 적혈구수명측정법(赤血球壽命測定法)(ICSH 추천))

  • Berlin, N.I.;Dudley, R.A.;Garby, L.;Heimpel, H.;Lee, M.;Lewis, S.M.;McIntyre, P.;Mollison, P.L.;Najean, Y.;Pettit, J.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.14 no.2
    • /
    • pp.1-9
    • /
    • 1980
  • 혈액질환(血液疾患), 특히 용혈성빈혈(溶血性貧血)을 수반(隨伴)한 경우(境遇)에 적혈구(赤血球)의 생성(生成), 파괴과정(破壞過程)을 정확히 파악하는 것은 빈혈(貧血)의 발생기전(發生機轉) 및 병인(病因), 치료(治療), 예후(豫後) 결정(決定)에 매우 중요(重要)하다. 적혈수명측정법(赤血壽命測定法)은 최근(最近) 방사성(放射性)동위원소(同位元素)를 이용(利用)한 방법(方法)이 소개된 이래 널리 시행(施行)되어 왔다. 그러나 그 방법(方法) 및 결과(結果) 해석(解釋)에 표준화(標準化)가 되어 있지 않았던 중 1971년 ICSH (International Committee for Standardization in Hematology)에서 expert panel을 갖고 ICSH 추천 방법(方法)을 발표(發表)하였고, 본지(本誌)에서도 그 내용(內容)을 게재(揭載)한 바 있다. 1980년 ICSH는 전문기관 및 전문가의 협조(協調)를 얻어 다시 expert panal을 갖은 후 1971년에 추진한 적혈구수명측정법(赤血球壽命測定法)의 일부(一部)를 수정(修正)하여 ICSH의 표준방법(標準方法)으로 발표(發表)하였다. 개정(改正)된 표준방법(標準方法)과 1971년 ICSH추친 방법(方法)과의 차이(差異)는 다음과 같다. $^{51}Cr$표지방법중(標識方法中) 참고방법(參考方法)(Reference method)인 ACD법(法)에 수정(修正)을 가하여, ACD solution 구성성분(構成成分)이 차이(差異)가 있으며, 표지(標識)$^{51}Cr$의 양(量)을 체중당(體重當) $1.5{\mu}Ci$에서 $0.5{\mu}Ci$로 제한(制限)시켰다. 투여방법(投與方法)에 대한 언급 특히 투여하는 표지적혈구(標識赤血球)의 용적을 정확하게 측정 하기 위한 방법 4가지를 추가하였고, 검체준비(檢體準備) 과정중(過程中)의 pipet error를 방지(防止)하기위해 일정(一定)한 형태의 pipet을 사용(使用)하며, 1ml의 tuterculin syringe는 사용(使用)하지 않기로 하였다. 또한 결과분석시(結果分析時) 혈구용적(血球容積)의 항정성(恒定性)을 위해 Sodium pertectnetate($^{99m}Tc$)를 이용(利用)해 혈구용적(血球容積)을 반복(反復)해 측정(測定)하도록 하였으며 이때 사용(使用)하는 방사성동위원소(放射性同位元素)는 $^{32}P$ 대신 $^{99m}Tc$로 하였다. 결과해석시(結果解釋時) IgG 항체(抗體) 또는 IgM 항체(抗體)에 따른 차이점(差異點)에 대한 고려가 추가(追加)되었다. ICSH와 국제혈액학회(國際血液學會)에서 수정(修正)된 ICSH 표준방법(標準方法)에 의한 적혈수명측정법(赤血壽命測定法)을 널리 소개(紹介)하여 결과(結果)의 표준화(標準化)를 기하고자 연관잡지(聯관(關)雜誌)에 게재(揭載)할 것을 요청(要請)하였기에 전문(全文)을 본지(本誌)에 소개(紹介)하고자 한다.

  • PDF

Quantifying Uncertainty of Vitamin C Determination in Infant Formula by Indophenol Titration Method (인도페놀 적정법에 의한 성장기용조제식 중 비타민 C 함량분석의 측정불확도 산정)

  • Jun, Jang-Young;Kwak, Byung-Man;Ahn, Jang-Hyuk;Kong, Un-Young
    • Korean Journal of Food Science and Technology
    • /
    • v.37 no.3
    • /
    • pp.352-359
    • /
    • 2005
  • Uncertainty involved during determination of vitamin C content in infant formula was quantified by indophenol titration method. Uncertainty sources in measurand, such as purity, weight, final volume of standard, volume of standard solution used for titration, sample weight, final volume of sample, extraction solution used for titration, titration of extraction solution and standard solution by indophenol solution were identified and used as parameters for combined standard uncertainty based on Guide to the expression of uncertainty in measurement (GUM) and Draft EURACHEM/CITAC Guide. Uncertainty parameters of each source in measurand were identified as resolution, reproducibility and stability of chemical balance, standard material purity, repeatability, reproducibility, end point of titration, 1 mL pipet, 5 mL autopipet, and 100 mL mass flask. Each uncertainty component was evaluated by types A and B and included to calculate combined uncertainty. Analytical test result for traceability under laboratorial conditions using Certified Reference Material (CRM) test was certified as $108.4{\pm}1.7mg/100g$, which was within CRM certification range of $114.6{\pm}6.6mg/100g$. Uncertainty test result of vitamin C content of 5 g sampling was $56.7{\pm}2.44mg/100g$. Uncertainty could be reduced by identification of uncertainty sources and components related with vitamin C determination by indophenol titration method and by decreasing uncertainty sources and components.