• Title/Summary/Keyword: pipe-network model

Search Result 110, Processing Time 0.021 seconds

A Study on Cost Benefit Analysis Optimization Model for Water Distribution Network Rehabilitation Project of Taebaek Region (태백권 배수관망 개량사업의 비용효과분석 최적화 모델 연구)

  • Kim, Taegon;Choi, Taeho;Kim, Kyoungpil;Koo, Jayong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.3
    • /
    • pp.395-406
    • /
    • 2015
  • This research carried out an analysis on input cost and leakage reduction effect by leakage reduction method, focusing on the project for establishing an optimal water pipe network management system in the Taebaek region, which has been executed annually since 2009. Based on the result, optimal cost-benefit analysis models for water distribution network rehabilitation project were developed using DEA(data envelopment analysis) and multiple regression analysis, which have been widely utilized for efficiency analysis in public and other projects. DEA and multiple regression analysis were carried out by applying 4 analytical methods involving different ratios and costs. The result showed that the models involving the analytical methods 2 and 4 were of low significance (which therefore were excluded), and only the models involving the analytical methods 1 and 3 were suitable. From the result it was judged that the leakage management method to be executed with the highest priority for the improvement of revenue water ratio was installation of pressure reduction valve, followed by replacement of water distribution pipe, replacement of water supply pipe, and then leakage detection and repair; and that the execution of leakage management methods in this order would be most economical. In addition, replacement of water meter was also shown to be necessary in case there were a large number of defective water meters.

The Development of Effective Database Model for Pipe Network Management Monitoring Program (상수도 관망시스템의 유지관리용 모니터링 프로그램을 위한 효율적 D/B 모델의 개발)

  • Kang, Byung-Mo;Lee, Hyun-Dong;Hong, In-Sik
    • Journal of Internet Computing and Services
    • /
    • v.9 no.4
    • /
    • pp.157-166
    • /
    • 2008
  • There has been a renewal of interest in management of underground facility in recent years. As several research have been made on management for underground facility of waterworks pipe. In this paper smart-tag is defined and applied to requiring ubiquitous environment. Also, GPS is essential technology for the implementation of proposed program, which has GPS and RFID mixed business model. And it manages data of underground facility with RFID system effectively and provides the high quality practical effectiveness of entire system through GPS receiving module and network communication on GIS. In conclusion, this paper proposed applications management system with location mixed database. Proposed database and interface skill is tested and evaluated through the simulation.

  • PDF

A Study on the Water-cooling Jacket Design of IPMSM for Railway Vehicles (철도차량용 IPMSM의 Water-cooling Jacket 설계 연구)

  • Park, Chan-Bae;Lee, Jun-Ho;Lee, Byung-Song
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.10
    • /
    • pp.1475-1480
    • /
    • 2013
  • In this paper, the basic design study of a water-cooling jacket, which have reported no cases for applying to railway traction motors so far, were conducted for applying to Interior Permanent Magnet Synchronous Motor (IPMSM) for railway vehicles. The basic thermal characteristics analysis of the 110kW-class IPMSM was performed by using 3-dimentional thermal equivalent network method. The necessary design requirements of the water-cooling jacket were derived by analyzing the results of the basic thermal properties. Next, the thermal characteristics analysis technique was established by using the equivalent model of the solenoid-typed pipe to be installed on the inside of the water-cooling jacket for 110kW-class IPMSM. Finally, a design model of 6kW-class water-cooling jacket was derived through the analysis of various design parameters.

Characteristic Studies on Loop Heat Pipe with Micro Ceramic Wick (마이크로 세라믹 윅을 사용한 루프 히트파이프의 특성 연구)

  • Park, Jong-Chan;Lee, Chung-Gu;Rhi, Seok-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.10
    • /
    • pp.823-831
    • /
    • 2007
  • This paper presents the experimental and simulation study of a loop heat pipe (LHP) that can be applied to present electronics, space missions and thermal control systems. The present experimental study was carried out employing sintered alumina ceramic wick ($d=2.96\;{\mu}m$, ${\phi}=0.61$). High purity R-134a, R-22 and water were also used as alternative working fluids in addition to ammonia. The experimental study showed that the maximum heat transfer performance for the test LHP in the vertical top heating mode was over 100 Watts when ammonia was used as the working fluid. The simulation results have been compared with the experimental results to validate a simulation model based on the thermal resistance network that was developed to evaluate the performance of LHPs, focusing on their prospective applications in electronics. The simulation model is based on the loop overall energy, mass, and momentum balance. The simulation program can predict the effects of various parameters which affect the performance of LHP within 5% compared with the experimental results.

Numerical Simulation of Oil Supply System of Reciprocating Compressor for Household Refrigerators (냉장고용 왕복동 압축기 급유 시스템의 수치해석)

  • Kim, H.J.;Lee, J.K.
    • Journal of Power System Engineering
    • /
    • v.9 no.4
    • /
    • pp.24-30
    • /
    • 2005
  • For a reciprocating compressor of household refrigerators, a direct analogy between the pipe flow network and the electric circuit network has been utilized to set up a mathematical model for oil supply system. Individual lubrication elements of the oil supply system, such as propeller- installed oil cap, oil galleries, radial oil feeding holes, spiral oil grooves, and various sliding surfaces have been analogized by equivalent electric elements, and these have been combined together to form an electric circuit corresponding to the whole oil supply system. By solving the closed network equations of the model, oil flow rates at various lubrication elements could be obtained. Total amount of the oil flow rate drawn into the shaft has been measured and compared reasonably well with the prediction of the numerical simulation.

  • PDF

Development of a Method to Reduce Damages by Pipe Failures (상수관 파괴에 의한 피해 경감기법의 개발)

  • Jun, Hwan-Don;Kim, Seok-Hyeon;Park, Moo-Jong;Kim, Joong-Hoon;Lee, Hwan-Goo
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.6
    • /
    • pp.31-36
    • /
    • 2008
  • A water distribution system should be constructed reasonably to supply water for the customer with proper quality and pressure as demands at nodes fluctuate with time. Also it should be reliable to minimize undesirable effects on the customer when various accidents happen such as pipe failures. A new method is presented here to reduce damages by pipe failures. For the work, two methods, namely, the method for estimating practical extent of damage by pipe failures and for estimating water distribution reliability, are adopted to analyze a water distribution system and to explore the damage reduction by pipe failures. As the results from the analysis of the model, the damage can be reduced effectively by increasing durability of each pipe in minimum cutsets according to the order of priority. The suggested method was applied to the Cherry-Hill network to verify its applicability.

Water pipe deterioration assessment using ANN-Clustering (ANN-Clustering 기법을 이용한 상수관로 노후도 평가 및 분류)

  • Lee, Sleemin;Kang, Doosun
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.11
    • /
    • pp.959-969
    • /
    • 2018
  • The aging water pipes induce various problems, such as water supply suspension due to breakage, insufficient water pressure, deterioration of water quality, damage by sink holes, and economic losses due to water leaks. However, it is impractical and almost impossible to repair and/or replace all deteriorated water pipes simultaneously. Hence, it is required to quantitatively evaluate the deterioration rate of individual pipes indirect way to determine the rehabilitation order of priority. In this study, ANN(Artificial Neural Network)-Clustering method is suggested as a new approach to assess and assort the water pipes. The proposed method has been applied to a water supply network of YG-county in Jeollanam-do. To assess the applicability of the model, the evaluation results were compared with the results of the Numerical Weighting Method (NWM), which is being currently utilized in practice. The assessment results are depicted in a water pipe map to intuitively grasp the degree of deterioration of the entire pipelines. The application results revealed that the proposed ANN-Clustering models can successfully assess the water pipe deterioration along with the conventional approach of NWM.

Simulation and Analysis of a Gas Pipeline Network in Kyungin Area using Statistical Approach (경인지역 가스 수송을 위한 배관망시스템의 모사 및 분석)

  • Lee Eun-Lyong;Chang Seung-Yong;Kim In-Won
    • Journal of the Korean Institute of Gas
    • /
    • v.1 no.1
    • /
    • pp.14-20
    • /
    • 1997
  • Pipeline network analysis requires fluid mechanics. A lot of equations have been used for flow analysis according to the behavior of fluid in pipelines and the operative situations. In this paper, simulation and analysis have been performed for the pipeline network system in Kyungin area using a steady-state mathematical model. Then, a statistical model using partial least squares(PLS) method has been developed with the data obtained from the developed mathematical model. The results showed that it is possible to simulate and analyze pipeline network systems using statistical approach.

  • PDF

Analysis of Operating and Maintenance Parameters for Agricultural Pipeline System Using EPANET (EPANET을 이용한 농업용 관수로 시스템의 운영 및 유지관리 인자 분석)

  • Kim, Nam Do;Kim, Sun Joo;Kwon, Hyung Joong;Kim, Phil Shik;Park, Hyun Jun
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.59 no.4
    • /
    • pp.17-26
    • /
    • 2017
  • In this study, EPANET model which is using on the pipe network analysis was applied to Haenam irrigation district has provided irrigation water by pipeline system about 1,125ha and then have built pipe network to study area and supply performance evaluation of existing structure was analyzed by SPA (Single Period Analysis) in EPANET. As model results of simulation average ratio of maximum supply quantity/irrigation water requirements(base demand) was analyzed by 2.63. It means also that was analyzed as being capable of ensuring the water supply capacity. It was provided the necessary information for the maintenance facility through analyzed hydraulic behaviors in the pipeline inside such as flow velocities, pressures and hydraulic grade lines. It was satisfied with the allowable design criteria that was compared analyzed results with presented allowable design standards at agricultural production infra improvement project planning and design (Pipeline design standard). In order to analyze efficiency promotions of irrigation water, using Extended Period Simulation it was compared supply quantity with irrigation water requirements while pumps set operating pattern in 24 hours, then efficiency promotions of irrigation water was determined through analyzed oversupply water quantity and occurrence time by branch lines. According to results for oversupply quantity in Haenam district by time and end of branch lines efficiency promotions of irrigation water was suggested from 0.33 % to 37.59 %. To draw reasonable operating rules for water use and through this research, it is expected to be helpful for efficient water use and operational management of agricultural pipeline system to the current agricultural irrigation.

Establishment of natural gas high-pressure pipeline network model in Korea (천연가스 전국 고압 배관망 모델 수립)

  • Park Young;Lee Young Chul;Lee Jeong Hwan;Cho Byoung Hak;Lim Jong Suk
    • Journal of the Korean Institute of Gas
    • /
    • v.5 no.2 s.14
    • /
    • pp.43-51
    • /
    • 2001
  • ln this study, a natural gas pipeline network model was established using STONER. First a map of natural gas pipeline network was drawn on STONER and then the length and diameter of the pipe were inputted. And as the specific gravity of gas flowing in the pipeline which is the value of natural gas was inputted. Finally in order to decide the pipeline variables and gas temperature, through the verification with observed real data, the possible error was minimized. For the verification, the pipeline variables and gas temperature were assumed and the pipeline network analysis was accomplished with real demand data. The square deviation of analysed pressure from observed pressure was calculated and the minimum case was selected for the optimum pipeline variables and gas temperature. Thus a proper natural gas pipeline network model for real network was established.

  • PDF