쓰레기 관로운송 시스템의 운송에너지 손실에 관한 수치해석적 연구 (Computational Study of Energy Loss in a Pipe of Refuse Collecting System)

  • 이종길;변재기;최영돈;최윤;홍기철
    • 설비공학논문집
    • /
    • 제24권1호
    • /
    • pp.37-44
    • /
    • 2012
  • This paper describes energy loss in a pipe line of refuse collecting system. Analysis of energy loss in a pipe line is the decisive factor in a design of refuse collecting system. Using the results of energy loss analysis, we can determine the power of turbo-blower. The flow characteristics of the pipe line with refuse bags were analyzed by three-dimensional CFD. The refuse bag is modeled by using the shape obtained from profile measurement. Friction factors were calculated with changing the refuse bag size, mixing ratio and Reynolds number. And drag coefficients were calculated using the CFD results. From the results we can calculate energy loss in a pipe line of refuse collecting system and predict the capacity of turbo-blower.

제한된 공간에 맞는 새로운 소음기부품의 개발에 대한 연구 (A Study on the Development of a New Muffler Component required in the Geometrically Constrained Space)

  • 이정권;이병호
    • 한국음향학회지
    • /
    • 제1권1호
    • /
    • pp.76-81
    • /
    • 1982
  • To get minimum noise level by making full use of the constrained geometric space and being compatible with the minimum pressure-drop condition, 3-pipe through-flow system is designed by inserting a new pipe which is shaped a resonator in the cavity of 2-pipe system. As a result of the 1/3-octave-band frequency analysis for the noise reduction characteristics, this system is proved to have good sound attenuation effect in the high frequency region, so that it is found to be a useful component of a muffler.

  • PDF

상수원 관망 부식 제어를 위한 부식성 수질 관리: 북미지역 관리 사례 및 국외 현황 (The Regulations and Guidelines for Management of Corrosive Water and Pipe Corrosion in Drinking Water Distribution System in North America)

  • 김민희;현승훈;이원석
    • 한국물환경학회지
    • /
    • 제33권3호
    • /
    • pp.359-369
    • /
    • 2017
  • Water distribution systems supply drinking water to consumers' taps. Internal corrosion of metallic pipe used in drinking water distribution systems has reduced water quality and led to increased levels of toxic heavy metals such as lead, copper and nickel. These problems have been experienced to varying degrees by water utilities in many countries. North America has successfully managed and controlled pipe corrosion and corrosive water in water distribution system based on various policies, regulations and rules. Practical and engineering guidelines for evaluation of pipe corrosion and determination of treatment options are also provided to assist drinking water supplies. In addition, the corrosion mechanism in water distribution systems, such as the complex effects of physical and chemical parameters on the corrosion pipes has been improved to accurately predict corrosion rates of metallic pipes in actual water distribution systems. This paper reviews various regulations, policy statement, and treatment produces on controlling corrosion in drinking water distribution systems in US and Canada and then offers suggestion for management of corrosive water and pipe corrosion in drinking water distribution system in Korea.

이중송수관로를 이용한 안정적인 송수를 위한 설계인자에 관한 연구 (A research on the design parameters for a double-transmission main system for sustainable water supply)

  • 현인환;홍준의;김두일
    • 상하수도학회지
    • /
    • 제27권1호
    • /
    • pp.129-138
    • /
    • 2013
  • Water interruption is often caused by a rupture in the branch-like singular pipeline. This will cause critical complaints from household and may decrease public service quality. As an alternative of singular pipeline, additional parallel pipeline could be installed for sustainable water supply. This system is called double pipeline system and able to be utilized for water transmission line between treatment plant and distribution reservoir. Construction of double pipeline was thought to increase capital cost, which can be an issue to waterworks authorities. Reducing capital cost was possible by means of installing connectors between two parallel pipelines because of reduced diameter of each pipe. To obtain optimal design condition for connectors, it was necessary to compare water pressure according to accident location, to investigate flow according to connection pipe spacing, connection pipe diameter, and aging of pipe. Reliable and economical connection layouts were determined based on these results. The cost estimation for each design condition was carried out. Cost was approximately reduced by 20 ~ 30 % compared to the double pipeline without connections. In addition to this, connection between double pipelines could expect extra benefits for maintenance since the pipe could be repaired and rehabilitated without interruption.

전자교환시스템 냉각을 위한 히트파이프 적용 연구 (A study on the application of heat pipe to the cooling of ATM switching system)

  • 김원태;이윤표;윤성영
    • 설비공학논문집
    • /
    • 제9권4호
    • /
    • pp.497-503
    • /
    • 1997
  • In the present study, the cooling package using the heat pipe has been developed to improve the thermal performance in the point of cooling characteristics of the electronic chip placed to the subrack being readily assembled and disassembled in ATM switching system. As the preliminary experiments, the cooling performances between a conventional way using a cooling fin and a proposed method applying the heat pipe are compared and analyzed. The cooling performance at a simulated electronic component packaging a heat pipe module is approximately achieved up to $5.0W/cm^2$ heat flux and the allowable temperature at the heated chip is sustained in the range within $70^{\circ}C$. From the results, it is confirmed that temperature oscillations are also settled by inserted wick in the evaporator section. From the user's viewpoint, the method to assemble and disassemble the heat pipe easily has been devised.

  • PDF

Non-invasive acceleration-based methodology for damage detection and assessment of water distribution system

  • Shinozuka, Masanobu;Chou, Pai H.;Kim, Sehwan;Kim, Hong Rok;Karmakar, Debasis;Fei, Lu
    • Smart Structures and Systems
    • /
    • 제6권5_6호
    • /
    • pp.545-559
    • /
    • 2010
  • This paper presents the results of a pilot study and verification of a concept of a novel methodology for damage detection and assessment of water distribution system. The unique feature of the proposed noninvasive methodology is the use of accelerometers installed on the pipe surface, instead of pressure sensors that are traditionally installed invasively. Experimental observations show that a sharp change in pressure is always accompanied by a sharp change of pipe surface acceleration at the corresponding locations along the pipe length. Therefore, water pressure-monitoring can be transformed into acceleration-monitoring of the pipe surface. The latter is a significantly more economical alternative due to the use of less expensive sensors such as MEMS (Micro-Electro-Mechanical Systems) or other acceleration sensors. In this scenario, monitoring is made for Maximum Pipe Acceleration Gradient (MPAG) rather than Maximum Water Head Gradient (MWHG). This paper presents the results of a small-scale laboratory experiment that serves as the proof of concept of the proposed technology. The ultimate goal of this study is to improve upon the existing SCADA (Supervisory Control And Data Acquisition) by integrating the proposed non-invasive monitoring techniques to ultimately develop the next generation SCADA system for water distribution systems.

250kW급 폐열회수 시스템용 유기랭킨사이클 배관 열유동해석에 관한 연구 (Thermal and Flow Analysis of Organic Rankine Cycle System Pipe Line for 250 kW Grade Waste Gas Heat Recovery)

  • 김경수;방세경;서인호;이상윤;이중섭
    • 한국기계가공학회지
    • /
    • 제18권4호
    • /
    • pp.26-33
    • /
    • 2019
  • This study is a thermal and flow analysis of Organic Rankine Cycle (ORC) pipe line for 250 kW grade waste gas heat recovery. We attempted to obtain the boundary condition data through the process design of the ORC, which can produce an electric power of 250 kW through the recovery of waste heat. Then, we conducted a simulation by using STAR-CCM+ to verify the model for the pipe line stream of the 250 kW class waste heat recovery system. Based on the results of the thermal and flow analyses of each pipe line applied to the ORC system, we gained the following conclusion. The pressure was relatively increased at the pipe outside the refracted part due to the pipe shape. Moreover, the heat transfer amount of the refrigerant gas line is relatively higher than that of the liquid line.

생활폐기물 자동집하시설의 관로망 최적 설계 (Optimal Piping Network Design of Pneumatic Waste Collection System)

  • 성순경;서상호
    • 한국유체기계학회 논문집
    • /
    • 제13권3호
    • /
    • pp.54-58
    • /
    • 2010
  • The pneumatic waste collection system, which is a complete solution for solving the waste collection problems, are constructed in many countries all over the world. However, research data for piping network design are insufficient. In this paper the pressure losses of the straight and curved pipes, pipe junctions are obtained using the numerical method in order to investigate the optimal pipe network design for the waste collection system. As an experimental result, the length of 1.8 meter is the reasonable for the radius of curvature of a curved pipe and the angle of 30 degree is suitable for confluent pipe.

쓰레기 관로운송 시스템의 운송에너지 손실에 관한 수치해석적 연구 (Computational Study of Energy Loss in a Pipe of Refuse Collecting System)

  • 이종길;최윤;홍기철;최영돈
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.421-426
    • /
    • 2009
  • This paper describes on energy loss in a pipe of refuse collecting system. Analysis energy loss in a pipe is the decisive factor in a design for refuse collecting system. From the analysis energy loss, we can determine the capacity of turbo blower. The flow characteristics in the pipe with the refuse bag are analyzed by three-dimensional Navier-Stokes analysis. The refuse bag is modeled using the actual measurement. We obtain friction factor by changing refuse bag's size and mixing ratio and Reynolds number. And From the result we calculate energy loss by using compressible flow analysis.

  • PDF

대체 난방용 히트파이프 온도 제어 시스템 설계에 관한 연구 (A Study on the Temperature Control System Design of Heat Pipe for Alternative Heating)

  • 윤석암;서장수;조경재;차인수
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(2)
    • /
    • pp.908-912
    • /
    • 2003
  • The waste heat recovery system using heat pipe was tested for the consideration of developing the high-efficiency waste heat recovery technology. Heat pipe, a effective device that can quickly transfer large amounts of heat energy using the phase change of the working fluid and the characteristics of Electric Heater Bars used for alternative heating system are introduced In this paper. In order to increase energy efficiency, the system which controls the status of electric heater bars and the temperature of heat pipe installed has developed.

  • PDF