• Title/Summary/Keyword: pipe joint

Search Result 172, Processing Time 0.034 seconds

The Proportional Hazards Modeling for Consecutive Pipe Failures Based on an Individual Pipe Identification Method using the Characteristics of Water Distribution Pipes (상수도 배수관로의 특성에 따른 개별관로 정의 방법을 이용한 파손사건 사이의 비례위험모델링)

  • Park, Suwan;Kim, Jung Wook;Jun, Hwan Don
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.1
    • /
    • pp.87-96
    • /
    • 2007
  • In this paper a methodology of identifying individual pipes according to the internal and external characteristics of pipe is developed, and the methodology is applied to a case study water distribution pipe break database. Using the newly defined individual pipes the hazard rates of the cast iron 6 inch pipes are modeled by implementing the proportional hazards modeling approach for consecutive pipe failures. The covariates to be considered in the modeling procedures are selected by considering the general availability of the data and the practical applicability of the modeling results. The individual cast iron 6 inch pipes are categorized into seven ordered survival time groups according to the total number of breaks recorded in a pipe to construct distinct proportional hazard model (PHM) for each survival time group (STG). The modeling results show that all of the PHMs have the hazard rate forms of the Weibull distribution. In addition, the estimated baseline survivor functions show that the survival probabilities of the STGs generally decrease as the number of break increases. It is found that STG I has an increasing hazard rate whereas the other STGs have decreasing hazard rates. Regarding the first failure the hazard ratio of spun-rigid and spun-flex cast iron pipes to pit cast iron pipes is estimated as 1.8 and 6.3, respectively. For the second or more failures the relative effects of pipe material/joint type on failure were not conclusive. The degree of land development affected pipe failure for STGs I, II, and V, and the average hazard ratio was estimated as 1.8. The effects of length on failure decreased as more breaks occur and the population in a GRID affected the hazard rate of the first pipe failure.

Fatigue Properties of the Small Diameter Branch Welded Pipe Joint with variation of Welding Procedures and Welding Shapes. (용접공정 및 용접형상 변화에 따른 소구경 분기배관 용접부의 피로특성)

  • 백종현;김철만;김우식
    • Proceedings of the KWS Conference
    • /
    • 2003.11a
    • /
    • pp.191-193
    • /
    • 2003
  • S-N fatigue tests were conducted to investigate the fatigue strength of the small diameter socket and butt welded joints of carbon steels. Experimental parameters were pipe diameter, throat depth, shape of socket welds and welding procedure. Filler metals used in SMAW and GTAW procedure were E9016-G with diameter of 4.0 mm and ER70S-G with diameter of 2.4 m. API 5L Gr.B pipes were adopted as a small diameter branch pipes. All socket fittings were machined from ASTM A105 carbon steel. Fatigue strength in socket weld joints increased with increasing pipe diameter, area of weld metal and weld leg length of pipe side.

  • PDF

Influence of Welding Shapes and Welding Procedures on Fatigue Strength of Small Diameter Branch Welded Pipe Joint (소구경 분기배관 용접부의 피로강도에 미치는 용접부 형상 및 용접공정의 영향)

  • Baek, Jong-Hyun;Kim, Cheol-Man;Kim, Woo-Sik
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1092-1097
    • /
    • 2003
  • S-N fatigue tests were conducted to investigate the fatigue strength of small diameter socket and butt welded joints made of carbon steels. Experimental parameters were pipe diameter, throat depth, shape of socket welds and welding procedure. Filler metals used in SMAW and GTAW procedure were E9016-G with diameter of 4.0 mm and ER70S-G with diameter of 2.4 mm. API 5L Gr.B pipes were adopted as a small diameter branch pipes. All socket fittings were machined from ASTM A105 carbon steel. Tensile strength was not affected by the welding procedure. Fatigue strength in socket weld joints increased with increasing pipe diameter, area of weld metal and weld leg length of pipe side.

  • PDF

Characteristic Evaluation of mock-up Structural Welding between casting and pipe for USC TPP ($621^{\circ}C$급 화력발전용 소재 실기규모 Mock-up품 구조용접부 특성평가)

  • Lee, Myeong-Yeol;Ji, Byeong-Ha;Song, Geun-Ho;Kim, Jeong-Tae
    • Proceedings of the KWS Conference
    • /
    • 2007.11a
    • /
    • pp.39-41
    • /
    • 2007
  • In this study, actual scale welding were conducted at the USC thermal power plant turbine and main steam pipe casting candidate mock up material 9Cr-1.5Mo-CoVNbNB steel(CB2) and 9Cr-0.5Mo-MVNbN steel(P92). And to evaluate the welding process for the actual production, mechanical property testes were conducted for the weld metal. The Mock-up welding condition successfully led to an excellent structural welding joint between casting and pipe material.

  • PDF

3D Hand Tracking Method Using the Range of Fingers Joint Motion and MediaPipe (손가락 관절 운동범위와 MediaPipe를 이용한 3 차원 손 추적 방법)

  • Yun, Hee-Heon;Jung-Min Park
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2023.05a
    • /
    • pp.752-753
    • /
    • 2023
  • 본 논문에서는 손가락 관절의 운동범위와 MediaPipe 손 추적기를 이용하여 3 차원 손 추적 방법을 설계하였다. MediaPipe 손 추적기가 추정한 신뢰할 수 있는 2 차원 좌표를 바탕으로 손 랜드마크의 깊이를 추정한 후, 손가락 관절 운동범위와 부합한 결과를 도출하였다. 본 논문에서 제안한 3 차원 손 추적 방법은 전용 하드웨어 없이 동작하며 기존의 3 차원 손 추적기에 비해 보다 직관적인 인간-컴퓨터 인터페이스 확산에 긍정적 영향을 줄 것으로 기대한다.

Sanitary Plumbing System Design of High-rise Building (초고층 건축물의 위생설비 시스템 설계)

  • Ju, Duck-Hoon;Byun, Woon-Seob;Yun, Hae-Dong
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.491-496
    • /
    • 2009
  • Recently, the high-rise building has been constructed competitively because it is symbol of the national competitive power including the technical power. The higher buildings are getting, the more important building mechanical systems are. So, the building mechanical systems are getting developed. Among the building mechanical systems, the sanitary system is basically necessary in order to maintain the building hygienically along with convenience and safety. This study has been investigated for various cases of high-rise building plumbing system. As a result, a variety of zoning method has been applied to most skyscrapers depending on the building height in the building mechanical system. And a variety of joint have been applied to minimize the Shortening and Sway. Also, the drainage in same uses has been discharged outside of a build through the one vertical pipe line. And airing system has been used like Individual Vent Pipe Yoke Vent Pipe Stack Vent Pipe Loop Vent Pipe Relief Vent Pipe method. It is sure that this study could be used as the high-rise building design.

  • PDF

Development of a Probability Model for Burst Risks of Water Main using the Analysis Methods of Leakage Type (매설환경에 따른 배수관망의 누수발생원인 특성분석)

  • Park, Sang-Bong;Choi, Tae-Ho;Koo, Ja-Yong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.2
    • /
    • pp.141-152
    • /
    • 2011
  • In this study, we extracted effective factors of pipe burst from the status data of water asset, operating data of pressure, volume and etc. and 7 years' pipe burst and repair records. The extracted factors were sorted by each attribution and then a statistical analysis was performed to generate a pipe burst probability function using the logistic regression model. As the result, material, diameter, length, laying year, pressure and road width affected to pipe burst significantly. Especially, in case of small diameter, laying year was most effective factor and in case of steel pipe, external loading was main cause of burst, and in case of cast iron, PE, PC, HP pipes, the deterioration of joint was main cause. The other side, as a result of Hosmer-Lemeshow goodness of fit test the models are turned out significant statistically. Also the classification criteria were determined to minimize the total cost from classification errors, when the predicted probability was more than 18% this pipe could have a chance of burst.

A Study on Modeling of the Ground Reinforcement under a Pipe Joint Subjected to Differential Settlement (부등침하를 받는 매설관 기초지반 보강 모델링 연구)

  • 손준익;홍성완
    • Geotechnical Engineering
    • /
    • v.7 no.1
    • /
    • pp.33-40
    • /
    • 1991
  • This paper reports the application study of the ground reinforcement under a pipe joint. The soil-reinforcement interaction helps to minimize the stress concentration at joint. The settlement pattern and the earth pressure variation have been evaluated under the pipeline subjected to differential settlement. The pipeline is fixed at one side with the other side set free being loaded with a uniform surface loading. The problem has been studied by means of laboratory model test and flite element technique, and the analysis results are compared for both non-reinforced and reinforced cases to evaluate the effectiveness of the soil reinforcement for restraining the settlement of the pipeline.

  • PDF

A Study on the Ignition Distance from a Leakage Point of the LP Gas Pipe (LP 가스 배관의 누출부로부터 점화가능 거리에 관한 연구)

  • Ryou, Young-Don;Kim, Young-Gu;Jo, Young-Do
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.5
    • /
    • pp.70-76
    • /
    • 2017
  • The standards related to the "Urban Gas Business Act" and the "Safety Control and Business Regulation of Liquefied Petroleum Gas Act" prescribe the separation distance between gas piping joint excluding welded joints and electric equipments(electric switch, watt meter, breaker, connector, etc). The "Korea Electro technical Regulation" also prescribes the distance between gas piping joints and electric equipments in accordance with the gas related standards. In case of the standards related to the "Urban Gas Business Act", the distance criteria stipulated in the standard of supplying facilities are different from those stipulated in the standard of using facilities. In this study, we have conducted pilot test on the possible ignition distance from the piping joint when LP gas is leaked from the point. We have also examined the adequacy of current standards on the separation distance between gas piping joint and electric equipments. As a result of the tests, we have found that ignition is able to occur at a distance of 30 cm as stipulated in the current standards or more when LP gas is leaked from the joint of the pipe. Therefore, we have made a decision that the criteria for separation distance between gas piping joint and electric equipment specified in the current standards related to the "Urban Gas Business Act" and the "Safety Control and Business Regulation of Liquefied Petroleum Gas Act" is appropriate.