고온 태양열기기용 액체금속 히트파이프의 작동조건에 따른 성능 특성 (Performance Characteristics of a Liquid-Metal Heat Pipe for igh-temperature Solar Thermal Devices Depending on the Operating Conditions)

  • 박철민;이정륜;부준홍;강용혁
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.247-250
    • /
    • 2009
  • Sodium heat pipe for high-temperature solar thermal application was manufactured and tested for transient and steady-state operations. Total length of the heat pipe was 650 mm and the outer diameter was 12.7 mm. Thermal performance was compared experimentally for two different cooling methods of the forced and the natural convection cooling in the heat pipe condenser. During the experiment, the maximum temperature was about 1300K, and different cooling methods were applied to the condenser region to charge the operating temperature. The effective thermal conductivity and the thermal resistance were investigated as a function of heat flux, heat transport length, and operating temperature.

  • PDF

냉수파이프에 의한 온실의 제습 및 증발냉각효율 (Dehumidification and Evaporative Cooling Efficiency by Water Pipes in Greenhouse)

  • 김문기;남상운;윤남규
    • 생물환경조절학회지
    • /
    • 제7권3호
    • /
    • pp.237-245
    • /
    • 1998
  • 극심한 고온으로 인해 정상적인 작물의 재배가 어려운 여름철의 온실 내 기온을 억제시키기 위한 방법 중 가장 효율을 인정받고 있는 증발냉각법은 실내 습도의 증가로 인해 그 사용에 제한을 받게 된다. 본 연구에서는 온실에서 증발냉각법의 냉방효율을 높이기 위한 방법으로 냉수파이프를 설치하여, 그 열적 특성을 분석하고, 제습효과를 조사하였으며, 그 결과를 요약하면 다음과 같다. 동파이프와 아연도금스틸파이프의 총열전달량을 비교한 결과, 동파이프가 다소 크게 나타났으나, 유의성이 없었으며, 두 가지 파이프 모두 이론값 보다 실측값이 더 작게 나타났다. 냉수파이프 표면에 응축되어 제거된 수증기의 양은 동파이프와 아연도금스틸파이프 사이에서 큰 차이를 보이지 않았으나, 두 가지 파이프 모두에서 제습효과는 충분히 큰 것으로 나타났다. 냉수파이프를 설치함으로써 증발냉각시스템의 냉방효율을 평균 48%만큼 높일수 있으며, 평균 1.3$^{\circ}C$만큼의 실내기온을 추가로 냉각시킬 수 있는 것으로 예측되었다. 또한, 냉수파이프를 이용해 증발냉각시스템의 가동으로 인한 실내의 과습문제를 해결하기 위해서는 파이프표면의 응축된 수분을 효과적으로 제거할 수 있는 장치나 방법에 대한 추가적인 연구가 필요할 것으로 판단된다.

  • PDF

벽체 구조물의 파이프쿨링 공법 적용성 분석 (Application of Pipe-cooling Method in the Concrete Wall Structure)

  • 신경섭;김세훈;차수원
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 추계 학술발표회 제20권2호
    • /
    • pp.501-504
    • /
    • 2008
  • 최근 들어 구조물의 노후화에 따른 콘크리트 구조물의 내구성에 대한 관심이 증대되고 있고, 특히 초기재령에서 발생하는 온도응력에 의한 균열은 구조물 전체의 내구성에도 큰 영향을 미친다. 콘크리트구조물의 온도응력에 의한 균열을 제어하는 방법으로는 크게 재료 및 배합상의 방법, 설계상의 방법, 시공상의 방법으로 나눌 수 있다. 이 중에서 시공상의 방법 중 하나로 콘크리트 단면내의 온도 상승량을 감소시킬 수 있는 파이프쿨링 공법에 의한 사후냉각효과에 대해 연구를 진행하고자 한다. 지금까지 파이프쿨링 공법은 주로 기초등의 매스콘크리트에 많이 적용되었지만 새로이 벽체에도 적용하였고, 파이프쿨링 요소를 묘사할 수 있는 범용구조해석 프로그램을 이용하여 파이프쿨링 공법이 적용된 벽체구조물에 대한 온도응력해석을 수행하였다. 벽체 구조물에 쿨링 파이프의 배치에 따른 해석 결과를 바탕으로 파이프쿨링 공법의 벽체구조물에 대한 냉각효과 및 균열제어 효과를 알아보았다.

  • PDF

멀티에어컨의 연결 배관길이의 변화에 따른 운전특성 변화 (The Variation of Multi Air Conditioner Operation Characteristics with the Arrangements of Connection Pipe Lengths)

  • 박병덕;하도용;정백영;고재윤;임장순
    • 태양에너지
    • /
    • 제20권4호
    • /
    • pp.45-52
    • /
    • 2000
  • Multi A/C is consisted of one outdoor unit and several indoor units. When the Multi Air conditioner is installed, we have to be cautious of the length of pipe arrangements. When the pipe arrangement is installed with unbalance or too long, there can be cooling capacity losses and low EER. An experimental study was carried out about the operation characteristic of Multi Air conditioner varying the length of pipe arrangements. If the pipe arrangement of the system is 15m, the cooling capacity and EER were decreased 0.8% and 1.3% respectively compared to the case when pipe arrangement is 5m. In case of 25m, the cooling capacity and EER were decreased 10.7% and 12.2% respectively compared to the case of 5m. When the length of pipe is not same each other, it is profitable to make the pipe length of highest capacity indoor unit shortest.

  • PDF

PHP를 이용한 히트싱크의 냉각 성능에 관한 연구 (A Study on Cooling Performance of Heat Sink using Pulsating Heat Pip)

  • 최우석;김종수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2438-2443
    • /
    • 2007
  • In order to guarantee the performance of electronic products. It is needed to improve the cooling performance of heat sink. So this paper has been made to investigate the cooling performance for the aluminum heat sink using pulsating heat pipe(PHP). The pulsating heat pipe was used as a heat spreader. Working fluid was R-22. Heater (50 mm ${\times}$ 50 mm ${\times}$ 3mm) was attached to heat sink and it generated 30W, 60W, 80W, 100W. Heat sink was tested for forced convection with 1${\sim}$4m/s of inlet air velocity. And both type heat sinks were carried out by using CFD simulation. This study showed that pulsating heat pipe can be a good tool to improve cooling performance of heat sink.

  • PDF

매스 콘크리트 구조물의 파이프 쿨링에 의한 냉각효과 (The Cooling Effect of Pipe Cooling in Mass Concrete Structures)

  • 오병환;신경준;차수원
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 봄 학술발표회 논문집(I)
    • /
    • pp.299-304
    • /
    • 1999
  • Cracking of concrete is one of the main issues of structural design next to ensuring the load-bearing capacity. Thermal cracking is a recurring concern in the production of concrete structures in particular when large, massive structures are considered. Thremal stresses arise from the differential temperature distribution either within s sturcture or between newly cast sectons and adjoining older parts. There are many different methods of reducing thermal stresses. A method often used for reducing temperature within a structure, is to cool the inner core with embedded cooling pipes. In this study, finite element method is employed for thermal analysis of concrete structures. To calculate water temperature variation in pipe, the conservation of thermal energy in internal flow was adopted. The cooling effect of pipe cooling is studied with several factors like convective coefficient, water temperature, concrete heat characteristics

  • PDF

ON-POWER DETECTION OF PIPE WALL-THINNED DEFECTS USING IR THERMOGRAPHY IN NPPS

  • Kim, Ju Hyun;Yoo, Kwae Hwan;Na, Man Gyun;Kim, Jin Weon;Kim, Kyeong Suk
    • Nuclear Engineering and Technology
    • /
    • 제46권2호
    • /
    • pp.225-234
    • /
    • 2014
  • Wall-thinned defects caused by accelerated corrosion due to fluid flow in the inner pipe appear in many structures of the secondary systems in nuclear power plants (NPPs) and are a major factor in degrading the integrity of pipes. Wall-thinned defects need to be managed not only when the NPP is under maintenance but also when the NPP is in normal operation. To this end, a test technique was developed in this study to detect such wall-thinned defects based on the temperature difference on the surface of a hot pipe using infrared (IR) thermography and a cooling device. Finite element analysis (FEA) was conducted to examine the tendency and experimental conditions for the cooling experiment. Based on the FEA results, the equipment was configured before the cooling experiment was conducted. The IR camera was then used to detect defects in the inner pipe of the pipe specimen that had artificially induced defects. The IR thermography developed in this study is expected to help resolve the issues related to the limitations of non-destructive inspection techniques that are currently conducted for NPP secondary systems and is expected to be very useful on the NPPs site.

HEV용 인버터의 방열을 위한 수냉식 배관구조 (Water Cooling Pipe Structure for Heat-Dissipation of HEV Inverter System)

  • 김경만;우병국;이용화;강찬호;전태원;조관열
    • 전력전자학회논문지
    • /
    • 제15권1호
    • /
    • pp.27-34
    • /
    • 2010
  • 하이브리드 전기자동차(HEV)용 인버터의 스위칭 소자에서 발생하는 열을 효율적으로 냉각시키기 위한 수냉식구조를 제안한다. 기존의 볼트형 냉각구조는 강한 수압에서 누수현상이 발생할 수 있으므로 본 논문에서는 이를 방지하기 위해 방열판 내에 파이프 형태의 구조를 적용하였다. 발열원을 기준으로 수로의 이격거리 변화와 여러 형태의 수로에 대해 방열현상을 시뮬레이션으로 해석하고, 방열효과가 우수한 2가지 배관구조 모델을 기준으로 방열효과를 비교 분석하였다. 시뮬레이션 결과를 토대로 2가지 배관구조를 적용한 HEV용 30kW급 인버터를 제작하여 방열효과를 검증하였다.

PHP를 결합한 알루미늄 히트싱크의 냉각성능에 관한 연구 (A Study on Cooling Performance of Aluminium Heat Sink with Pulsating Heat Pipe)

  • 김종수;하수정;권용하
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제35권8호
    • /
    • pp.1016-1021
    • /
    • 2011
  • 열전소자를 이용한 냉각 장치에 있어서 열전소자발열부측의 제거 열량은 제품의 성능 및 적용범위를 결정하는 주요변수가 되므로 히트싱크의 열저항을 최소화 할 수 있는 최적 조건의 히트싱크 설계를 필요로 한다. 발열부가 작고 상대적으로 히트싱크 면적이 커서 히트싱크 전체면으로 열확산이 필요한 경우 히트싱크의 방열 성능을 향상시키기 위하여 작동유체 R-22의 진동형 히트파이프를 이용하여 열전소자의 발열부측의 발열량(30W, 60W, 80W, 100W)과 공기 유속(1~4 m/s)에 따른 히트싱크의 열저항 실험 및 수치해석 결과와 비교 분석을 통해 히트싱크의 냉각 성능을 향상 시킬 수 있는 방법을 연구하였다.