• 제목/요약/키워드: pin-hole

검색결과 200건 처리시간 0.027초

Extreme Ultraviolet Plasma and its Emission Characteristics Generated from the Plasma Focus in Accordance with Gas Pressure for Biological Applications

  • Kim, Jin Han;Lee, Jin Young;Kim, Sung Hee;Choi, Eun Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 한국진공학회 2013년도 제45회 하계 정기학술대회 초록집
    • /
    • pp.178.2-178.2
    • /
    • 2013
  • Conventional ultraviolets A,B,C are known to be very important factor of killing, changing surface properties of biological cells and materials. It is of great importance to investigate the influence of extreme ultraviolet (EUV) exposure on the biological cell. Here we have studied high density EUV plasma and its emission characteristics, which have been generated by plasma focus device with hypercycloidal pinch (HCP) electrode under various Ar gas pressures ranged from 30~500 mTorr in this experiment. We have also measured the plasma characteristics generated from the HCP plasma focus device such as electron temperature by the Boltzman plot, plasma density by the Stark broading method, discharge images by open-shuttered pin hole camera, and EUV emission signals by using the photodiode AXUV-100 Zr/C.

  • PDF

Study on the Improvement of Adhesion between Cu Laminate and PSR (동박과 PSR간의 접합력 향상에 관한 연구)

  • 김경섭;정승부;신영의
    • Journal of Welding and Joining
    • /
    • 제17권2호
    • /
    • pp.61-65
    • /
    • 1999
  • Because of the need for packages which accommodate high pin count, high density and high speed device, PBGA(plastic ball grid array) package gets more spotlight. But the substrate material which is used for PBGA package is in nature susceptible to moisture penetration. The objective of the study is to find out the path of delamination in the stacked structure of substrate. To increase the adhesion between the cooper laminate and PSR(photo solder resist) which is the weakest part, experiments were performed by changing parameters of printing pre-treatment and post-treatment process. As a result of experiments, the factor effects on the adhesion between the cooper laminate and PSR is caused by all of the pre-treatment and post-treatment condition. A considerable change was observed depending on the amount of UV irradiation after thermal cure which is typical of printing post-treatment condition rather than pre-treatment condition.

  • PDF

A novel hemispherical microbond specimen for evaluating the interfacial shear strength of single fiber composite (복합재료의 계면 전단강도를 평가하기 위한 새로운 반구형 미소접합 시험편)

  • Park, Joo-Eon;Choi, Nak-Sam
    • Composites Research
    • /
    • 제21권2호
    • /
    • pp.25-30
    • /
    • 2008
  • A hemispherical microbond specimen adhered onto single carbon fiber has been proposed for evaluating the interfacial shear strength between epoxy and carbon fiber. Hemispherical microbond specimens showed low interfacial shear strength data and its small standard deviation as compared with the droplet one, which seemed to be caused by the reduction of the meniscus effects and of the stress concentration in the region contacting with the tip of pin hole. In comparison with the droplet specimen the hemispherical specimen showed the shear stress distribution similar to the cylindrical one in that low stress concentration arose around the contacting region. Average interfacial shear strength obtained by the hemispherical ones represented a good correlation with the hardness of the epoxy matrix.

Influence of Iodinated Contrast Media and Paramagnetic Contrast Media on Changes in Uptake Counts of 99mTc

  • Cho, Jae-Hwan;Lee, Jin-Hyeok;Park, Cheol-Soo;Lee, Sun-Yeob;Lee, Jin;Moon, Deog-Hwan;Lee, Hae-Kag
    • Journal of Magnetics
    • /
    • 제19권3호
    • /
    • pp.248-254
    • /
    • 2014
  • The purpose of this study is to figure out how uptake counts of technetium ($^{99m}Tc$) among radioisotopes in the human body are affected if computed tomography (CT), magnetic resonance imaging (MRI) and isotope examination are performed consecutively. $^{99m}Tc$ isotope material, iodinated contrast media for CT and paramagnetic contrast media for magnetic resonance (MR) were used as experimental materials. First, $^{99m}Tc$ was added to 4 cc normal saline in a test tube. Then, 2 cc of CT contrast media such as $Iopamidol^{(R)}$ and $Dotarem^{(R)}$ were diluted with 2 cc normal saline, and 2cc of MRI contrast media such as $Primovist^{(R)}$ and $Gadovist^{(R)}$ were diluted with 2 cc normal saline. Each distributed contrast media was a total of 4 cc and included 10m Ci of $^{99m}Tc$. A gamma camera, a LEHR (Low energy high resolution) collimator and a pin-hole collimator were used for image acquisition. Image acquisition was repeated a total of 6 times and 120 frames were obtained and uptake counts of $^{99m}Tc$ were measured (from this procedure). In this study, as a result of measuring the uptake counts of $^{99m}Tc$ using the LEHR collimator, the uptake counts were less measured in all contrast media than normal saline as a reference. In particular, the lowest uptake counts were measured when $Gadovist^{(R)}$, contrast media for MRI, was used. However, the result of measuring the uptake counts of $^{99m}Tc$ using the pin-hole collimator showed higher uptake counts in all contrast media, except for $Iopamidol^{(R)}$, than normal saline as a reference. The highest uptake counts were measured particularly when $Primovist^{(R)}$, contrast media for MRI, was used. In performing the gamma camera examination using contrast media and $^{99m}Tc$, it is considered significant to check the changes in the uptake counts to improve various diagnosis values.

A Study on Loading Method of Large Scaffolding Module for LNG Carriers Using TRIZ (TRIZ를 이용한 LNG 운반선 대형 비계 모듈의 탑재 방안 연구)

  • Park, Myeong-Chul;Shin, Sang-Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • 제22권3호
    • /
    • pp.94-100
    • /
    • 2021
  • To improve the productivity of cargo containment construction for a membrane LNG carrier, it is important to shorten the installation period and process of the scaffolding system, which is a construction workbench of a cargo containment for a membrane LNG carrier. As an effective method, opinions are being gathered to enlarge the lifting unit from the existing two stages to eight stages. On the other hand, the stresses around the pin and hole will increase significantly because of the increase in lifting load according to the large size of the module. The purpose of this study was to establish a new large module-lifting plan by introducing TRIZ to solve these problems. This study adopted a method to utilize 40 inventive principles, which is one of the various problem-solving tools of TRIZ. First, technical contradictions were derived, the engineering parameters were selected. Second, efficient inventive principles were selected to overcome the technical contradictions using a contradiction matrix. Finally, the general and specific solutions were derived through the selected inventive principle, and structural analysis confirmed that the stress generated in the structure was low. The utility of TRIZ was confirmed by the successful lifting of large modules using the established lifting method.

Interfacial shear strength test by a hemi-spherical microbond specimen of carbon fiber and epoxy resin (탄소섬유/에폭시의 반구형 미소접합 시험편에 대한 계면강도 평가)

  • Park, Joo-Eon;Gu, Ja-Uk;Kang, Soo-Keun;Choi, Nak-Sam
    • Composites Research
    • /
    • 제21권4호
    • /
    • pp.15-21
    • /
    • 2008
  • Interfacial shear strength between epoxy and carbon fiber was analyzed utilizing a hemi-spherical microbond specimens adhered onto single carbon fiber. The hemi-spherical microbond specimen showed high regression coefficient and small standard deviation in the measurement of interfacial strength as compared with a droplet and an inverse hemi-spherical one. This seemed to be caused by the reduced meniscus effects and the reduced stress concentration In the region contacting with a pin-hole loading device. Finite element analysis showed that the stress distributions along the fiber/matrix interface in the hemi-spherical specimen had a stable shear stress distribution along the interface without any stress mode change. The experimental data was also different according to the kinds of loading device such as the microvise-tip and the pin-holed plate.

Standardization of machining process for progressive press die (순차이송형 프레스 금형의 가공표준화)

  • Lee, S.M.;Lee, S.J.
    • Journal of the Korean Society for Precision Engineering
    • /
    • 제10권2호
    • /
    • pp.114-125
    • /
    • 1993
  • In the present study the newly developed CAD/CAM system is applied to the process of the molding design, machining for mini-sized and precise processive die, and the production of press-stamped parts. When the design of a die was completed by means of CAD, wire cut NC data were generated with the aid of a design drawing in the CAD system and then inputed into the wire cut machine, and with the aid of a hole chart which had been made for this purpose, all the data were classified into the categories of CNC milling, jig boring, jig grinding, and machine center, and then developing a program of generating NC data, errors in process were reduced and programming time was shortened. The program was developed by using Autolisp language which was built-in the CAD, and realizing the intergation of designing a die, generating and processing NC data directly by a designer, designing time and machinery processing time were shorted. And the traditionally required working time for design. NC program required 6 days of work becomes 4 days of work by using the developed CAD/CAM system so that the efficiency shows 150% of the reduction working time. The prpgram of the design of the automation a progressive die mold was developed in the PC-Class Autocad system, therefore development expense could be reduced, and the integration of the CAD/CAM of the progressive die mold with the standard DB being built could be realized.

  • PDF

Flowable Oxide를 이용한 저온 Flexible OLED 박막봉지 제작

  • Yong, Sang-Hyeon;Kim, Dae-Gyeong;Kim, Hun-Bae;Jo, Seong-Min;Chae, Hui-Yeop
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 한국진공학회 2012년도 제43회 하계 정기 학술대회 초록집
    • /
    • pp.249-249
    • /
    • 2012
  • 최근 주목받고 있는 Flexible Organic Light Emitting Diode (OLED) display에서는 Flexible 특성이 요구된다. 이는 현재 쓰이는 유리기판 대신 플라스틱기판으로 만들어야 가능하다. 하지만 플라스틱기판은 구성물질로 유기물을 사용하므로 수분과 산소의 투과에 매우 취약하다. 이는 장시간 사용 시 기판 위에 제작된 소자성능저하를 야기하는 등의 소자 신뢰도에 치명적 결함을 갖게 하는 원인이 된다. 따라서 기판 위의 소자를 보호할 수 있는 봉지기술 개발이 필요한데 가장 잘 알려진 플라스틱 기판에 적합한 Barrier기술로 유기물과 무기물을 교대로 적층하는 기술[1] 등이 있다. 본 연구에서는 PE-CVD 공정기술을 이용한 Flowable Oxide 박막과 ALD 공정기술을 이용한 Al2O3 무기물 박막을 적층하여 봉지박막을 구성하려 한다. Flowable Oxide는 저온공정이 가능하며 높은 증착속도와 뛰어난 Gap fill 특성을 가지고 있는데 이는 플라스틱기판의 엉성한 분자구조를 치밀하게 만들 것으로 예상되며 표면의 Pin-hole 또한 쉽게 채우는 특성이 있다. 실험은 Polyethylene Naphthalate (PEN) film 위에 PE-CVD 공정을 이용하여 Flowable Oxide를 증착하고, 그 후에 ALD 공정을 이용하여 Al2O3을 적층한 것을 하나의 샘플로 하였다. 샘플의 분석은 Ca test를 이용한 Water Vapor Transmission rate(WVTR)과 FT-IR, FE-SEM을 이용하여 분석하였다. FT-IR로 박막의 구성요소를 확인 하고 FE-SEM으로 박막의 Cross section image를 얻을 수 있었으며 또한 $4.85{\times}10^{-5}g/m^2$ day의 초기 WVTR 값을 얻을 수 있었다.

  • PDF

Control of a mobile robot supporting a task robot on the top

  • Lee, Jang M.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 Proceedings of the Korea Automatic Control Conference, 11th (KACC); Pohang, Korea; 24-26 Oct. 1996
    • /
    • pp.1-7
    • /
    • 1996
  • This paper addresses the control problem of a mobile robot supporting a task robot with needs to be positioned precisely. The main difficulty residing in the precise control of a mobile robot supporting a task robot is providing an accurate and stable base for the task robot. That is, the end-plate of the mobile robot which is the base of the task robot can not be positioned accurately without external position sensors. This difficulty is resolved in this paper through the vision information obtained from the camera attached at the end of a task robot. First of all, the camera parameters were measured by using the images of a fixed object captured by the camera. The measured parameters include the rotation, the position, the scale factor, and the focal length of the camera. These parameters could be measured by using the features of each vertex point for a hexagonal object and by using the pin-hole model of a camera. Using the measured pose(position and orientation) of the camera and the given kinematics of the task robot, we calculate a pose of the end-plate of the mobile robot, which is used for the precise control of the mobile robot. Experimental results for the pose estimations are shown.

  • PDF

Improved Bias Stress Stability of Solution Processed ITZO/IGZO Dual Active Layer Thin Film Transistor

  • Kim, Jongmin;Cho, Byoungdeog
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 한국진공학회 2015년도 제49회 하계 정기학술대회 초록집
    • /
    • pp.215.2-215.2
    • /
    • 2015
  • We fabricated dual active layer (DAL) thin film transistors (TFTs) with indium tin zinc oxide (ITZO) and indium gallium zinc oxide (IGZO) thin film layers using solution process. The ITZO and IGZO layer were used as the front and back channel, respectively. In order to investigate the bias stress stability of ITZO SAL (single active layer) and ITZO/IGZO DAL TFT, a gate bias stress of 10 V was applied for 1500 s under the dark condition. The SAL TFT composed of ITZO layer shows a poor positive bias stability of ${\delta}VTH$ of 13.7 V, whereas ${\delta}VTH$ of ITZO/IGZO DAL TFT was very small as 2.6 V. In order to find out the evidence of improved bias stress stability, we calculated the total trap density NT near the channel/gate insulator interface. The calculated NT of DAL and SAL TFT were $4.59{\times}10^{11}$ and $2.03{\times}10^{11}cm^{-2}$, respectively. The reason for improved bias stress stability is due to the reduction of defect sites such as pin-hole and pores in the active layer.

  • PDF