• Title/Summary/Keyword: pin joint

Search Result 172, Processing Time 0.024 seconds

A Study on Estimating of Fretting Wear of a Spline Coupling (스플라인 커플링의 프레팅 마멸 예측에 관한 연구)

  • Kim, Eung-Jin;Lee, Sang-Don;Cho, Yong-Joo
    • Tribology and Lubricants
    • /
    • v.25 no.4
    • /
    • pp.256-260
    • /
    • 2009
  • Fretting is a kind of wear which effects on reliability and durability. When machine parts are joined joint in parts such as a bolt or a rivet or a pin, fretting phenomenon is occurred by micro relative movement. When fretting occurs in joint parts, there is wear which is the cause of fatigue crack. Recently, although the ways of assessment of fatigue and damage tolerance are established, there is no way to evaluate fatigue crack initiation life by fretting phenomenon. Consequently, the prediction of life and prevention plan caused by fretting are needed to improve reliability. The objective of this paper is to predict fretting wear by using a experimental method and contact analysis considering wear process. For prediction of fretting wear volume, systematic and controlled experiments with a disc-plate contact under gross slip fretting conditions were carried out. A modified Archard equation is used to calculate wear depths from the contact pressure and stroke using wear coefficients obtained from the disc-plate fretting tests.

Bony Fragment Excision Followed by Multiple Drilling and Fragment Fixation Using Bio-absorbable Pins for Bilateral Osteochondral Fracture of the Lateral Talar Dome: A Case Report (양측 족관절에 발생한 외측 거골원개 골연골의 골절에 대한 골편제거 후 다발성 천공술 및 생흡수성 핀을 이용한 골편고정: 증례 보고)

  • Lee, Yong Jae;Suh, Jin Soo;Choi, Jun Young
    • Journal of Korean Foot and Ankle Society
    • /
    • v.23 no.4
    • /
    • pp.201-207
    • /
    • 2019
  • An osteochondral fracture is considered to be an injury involving the cartilage and subchondral bone. Acute traumatic osteochondral fractures can be related to joint instability because abnormal joint motion causes shearing and rotatory stress. Acute osteochondral fractures are frequently missed or misdiagnosed as a pure soft tissue injury. Thus, surgeons' proactive attention is highly required as articular cartilage has limited potential for self-repair and these lesions may develop osteoarthritis. In order to minimize the progression of post-traumatic osteoarthritis, it is important to properly identify and treat osteochondral fractures. Yet, little is known about the operative management of acute osteochondral fractures of the talus. We report here on a case of a middle-aged male with acute osteochondral fractures of the bilateral lateral talar dome. We applied different operative methods on each side with regard to fragment size and stability. A favorable clinical outcome was obtained at 18 months follow-up.

Improved Wearability of the Upper Limb Rehabilitation Robot NREX with respect to Shoulder Motion (어깨의 움직임을 중심으로 한 상지재활로봇 NREX의 착용감 개선)

  • Song, Jun-Yong;Lee, Seong-Hoon;Song, Won-Kyung
    • The Journal of Korea Robotics Society
    • /
    • v.14 no.4
    • /
    • pp.318-325
    • /
    • 2019
  • NREX, an upper limb exoskeleton robot, was developed at the National Rehabilitation Center to assist in the upper limb movements of subjects with weak muscular strength and control ability of the upper limbs, such as those with hemiplegia. For the free movement of the shoulder of the existing NREX, three passive joints were added, which improved its wearability. For the flexion/extension movement and internal/external rotation movement of the shoulder of the robot, the ball lock pin is used to fix or rotate the passive joint. The force and torque between a human and a robot were measured and analyzed in a reaching movement for four targets using a six-axis force/torque sensor for 20 able-bodied subjects. The addition of two passive joints to allow the user to rotate the shoulder can confirm that the average force of the upper limb must be 31.6% less and the torque must be 48.9% less to perform the movement related to the axis of rotation.

Application of epoxy putty external skeletal fixator for stabilization of tarsocrural arthrodesis in small dogs and cats

  • Moon, Je-Sung;Lee, June-Sub;Han, Hyun-Jung
    • Korean Journal of Veterinary Research
    • /
    • v.60 no.4
    • /
    • pp.187-194
    • /
    • 2020
  • Two small-breed dogs and two cats, with an average body weight of 4.88 kg (range: 4.3-5.5 kg), suffered hindlimb lameness due to luxation with or without fractures of the tarsocrural joint. These patients underwent tarsocrural arthrodesis with epoxy putty external skeletal fixator. The animals' skins were incised minimally, and the articular cartilage of the tarsocrural joint was removed, followed by autogenous cancellous bone grafting. Epoxy putty and positive Centerface®, pins with diameters 1.2 mm and 2.0 mm, were used for connecting bar and as a full pin fixation, respectively. All the patients regained the ability to bear weight on the affected limb within 3-7 days and resumed a normal gait within 9-15 weeks. The external skeletal fixator frame was removed within 13-17 weeks without major complications. Tarsocrural arthrodesis using epoxy putty external skeletal fixator resulted in excellent outcomes without severe postoperative complications in this study. Epoxy putty external skeletal fixator can be a valuable surgical option for tarsocrural arthrodesis in patients weighing less than 5.5 kg.

Experimental investigation on strength of CFRST composite truss girder

  • Yinping Ma;Yongjian Liu;Kun Wang
    • Steel and Composite Structures
    • /
    • v.48 no.6
    • /
    • pp.667-679
    • /
    • 2023
  • Concrete filled rectangular steel tubular (CFRST) composite truss girder is composed of the CFRST truss and concrete slab. The failure mechanism of the girder was different under bending and shear failure modes. The bending and shear strength of the girder were investigated experimentally. The influences of composite effect and shear to span ratio on failure modes of the girder was studied. Results indicated that the top chord and the joint of the truss were strengthened by the composited effect. The failure modes of the specimens were changed from the joint on top chord to the bottom chord. However, the composite effect had limited effect on the failure modes of the girder with small shear to span ratio. The concrete slab and top chord can be regarded as the composite top chord. In this case, the axial force distribution of the girder was close to the pin-jointed truss model. An approach of strength prediction was proposed which can take the composite effect and shear to span ratio into account. The approach gave accurate predictions on the strength of CFRST composite truss girder under different bending and shear failure modes.

A Study on Strength Prediction of Mechanical Joint of Composite under Bending Load (굽힘 하중을 받는 복합재 기계적 체결부의 강도예측에 관한 연구)

  • Baek, Seol;Kang, Kyung-Tak;Lee, Jina;Chun, Heoung-Jae
    • Composites Research
    • /
    • v.27 no.6
    • /
    • pp.213-218
    • /
    • 2014
  • This paper predicted the strength of mechanical joint of composites under bending load by means of the characteristic curve method. The method has been employed only for tensile and compression load conditions, but in this study, this method was extended to the bending load condition. For the finite element analysis (FEA), the nonlinear analysis was conducted considering the contact and friction effects between composite material and pin. The failure strength and mode on characteristic curve were evaluate with Tsai-Wu failure theory. To validate the results of FEA, the experiments were conducted to find out the failure load by applying bending moment on the composite specimens. The results showed reasonable agreements with theoretical results. These results lead to a conclusion that the characteristic curve method can be applied to predict the bending strength of mechanical joint of composites.

A 6-degree-of-freedom force-reflecting hand controller using fivebar parallel mechanism (+5각 관절 병렬 구조를 이용한 6자유도 힘 반사형 원격 조종기)

  • 진병대;우기영;권동수
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.1545-1548
    • /
    • 1997
  • A Force-refecting hand controller can provide the kinesthetic information obtained from a slave manipulator to the operator of a teleoperation system. This thesis presents the desgn and the analysis of a 6-degree-of-freedom force-reflecting hand controller using fivebar parallel mechanism. The goal of this thesis is to construct a superior hand controller that can provide large workspace and good force-reflecting ability. The forward kinematics of the fivebar paprallel mechanism has been calculated in real-time using three pin-joint sensors in addition to six actuator position sensors. A force decomposition approach is used to comput the Jacobin. To analyze the characteristics of the fivebar parallel mechanism, it has been compared with the other three parallel mechanisms in terms with workspace and manipulability measure. The force-reflecting hand controller using the fivebar parallel mechanism has been constructed and tested to verify the feasibility of the design concept.

  • PDF

Strength Estimation of Composite Joints Based on Progressive Failure Analysis (점진적 파손해석 기법을 이용한 복합재 체결부의 강도해석)

  • 신소영;박노회;강경국;권진회;이상관;변준형
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2001.05a
    • /
    • pp.163-167
    • /
    • 2001
  • A two-dimensional progressive failure analysis method is presented for the strength characterization of the composite joints under pin loading. The eight-nodes laminated she]1 element is utilized based on the updated Lagrangian formulation. The criteria by Yamada-Sun, Tsai-Wu, and the maximum stress are used for the failure estimation. The stiffness of failed layer is degraded by the complete unloading method. No factor depending on test is included in the finite element analysis except for the material strength and stiffness. Total 20 plate specimens with and without hole are tested to validate the finite element prediction. The Tsai-Wu failure criterion most conservatively estimates the strength of laminate, and the maximum stress criterion yields the highest strength because it does not consider the coupling of the failure modes. The strength by Yamada-Sun method neglecting the matrix failure effect are located between other two methods and shows best agreement with test result for laminate with hole.

  • PDF

Experimental Study on Hardness and Wear Characteristics of Welded Rails (레일 용접부의 경도와 마멸특성에 관한 실험적 연구)

  • Kim, Chung-Kyun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.2 s.173
    • /
    • pp.431-437
    • /
    • 2000
  • In this paper, thermite and gas pressure weldings have been used to join rails in-track and analyzed as functions of hardness and wear characteristics. The wear rate of thermite welded rail is low compared with that of gas pressure welded rail, which is tested in a pin-on-disk wear tester. The hardness of thermite welded materials is relatively high and narrowly distributed between three zones; welded part, thermally affected zone, and base matrix. Wear of a welded rail may be a major factor in railroad maintenance costs and failures at the rail-rail huh joint.

A Six-Degree-of-Freedom Force-Reflecting Master Hand Controller using Fivebar Parallel Mechanism (5각 관절 병렬 구조를 이용한 6자유도 힘 반사형 마스터 콘트롤러)

  • 진병대;우기영;권동수
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.5 no.3
    • /
    • pp.288-296
    • /
    • 1999
  • A force-reflecting hand controller can provide the kinesthetic information obtained from a slave manipulator to the operator of a teleoperation system. The goal is to construct a compact hand controller that can provide large workspace and good force-reflecting capability. This paper presents the design and the analysis of a 6-degree-of-freedom force-reflecting hand controller using fivebar parallel mechanism. The forward kinematics of the fivebar parallel mechanism has been calculated in real-time using three pin-joint sensors in addition to six actuator position sensors. A force decomposition approach is used to compute the Jacobian. To evaluate the characteristics of the fivebar parallel mechanism, it has been compared with the other three parallel mechanisms in terms with workspace and manipulability measure. The hand controller using the fivebar parallel mechanism has been constructed and tested to verify the feasibility of the design concept.

  • PDF