• Title/Summary/Keyword: piezoelectric property

Search Result 115, Processing Time 0.025 seconds

Ferroelectricity of the $Pb(Sc_{1/2}Nb_{1/2}$O$_3$-$PbTiO_3$ based Ceramics ($Pb(Sc_{1/2}Nb_{1/2}$O$_3$-$PbTiO_3$계 세라믹스의 강유전성)

  • 김진수;김소정;김호기;이덕출
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.11a
    • /
    • pp.149-152
    • /
    • 1997
  • High-power piezoelectric materials are being developed for applications such as actuators and ultrasonic motors. In this paper, ferroelectric property of iron-doped 0.57 (Sc$_{1}$2//Nb$_{1}$2/)O$_3$-0.43 PbTiO$_3$. which is the morphotropic phase boundary composition for the PSN-PT system, was investigated. The maximum dielectric constant ( $\varepsilon$$_{33}$/$\varepsilon$$_{0}$ = 2551) and the minimum dielectric loss(tan $\delta$ = 0.51 %) at room temperature were obtained at 01. wt% and 0.3 wt% of iron additions. With additions of the Fe$_2$O$_3$ the electromechanical coupling factor of radial mode k$_{p}$ and the piezoelectric coefficient d$_{33}$ were slightly decreased, on the other hand the mechanical quality factor was increased significantly. The highest mechanical quality factor (Qm= 297) was obtained at 0.3 wt% Fe$_2$O$_3$, which is 4.4 times larger than that of pure 0.57 PSN-0.43PT ceramics. The temperature dependence of the dielectric constant and dielectic loss was observed between 2$0^{\circ}C$ and 35$0^{\circ}C$ .X> .X> .

  • PDF

Performance analysis of bone scaffolds with carbon nanotubes, barium titanate particles, hydroxyapatite and polycaprolactone

  • Osfooria, Ali;Selahi, Ehsan
    • Biomaterials and Biomechanics in Bioengineering
    • /
    • v.4 no.1
    • /
    • pp.33-44
    • /
    • 2019
  • This paper presents a novel structural composition for artificial bone scaffolds with an appropriate biocompatibility and biodegradability capability. To achieve this aim, carbon nanotubes, due to their prominent mechanical properties, high biocompatibility with the body and its structural similarities with the natural bone structure are selected in component of the artificial bone structure. Also, according to the piezoelectric properties of natural bone tissue, the barium titanate, which is one of the biocompatible material with body and has piezoelectric property, is used to create self-healing ability. Furthermore, due to the fact that, most of the bone tissue is consists of hydroxyapatite, this material is also added to the artificial bone structure. Finally, polycaprolactone is used in synthetic bone composition as a proper substrate for bone growth and repair. To demonstrate, performance of the presented composition, the mechanical behaviour of the bone scaffold is simulated using ANSYS Workbench software and three dimensional finite element modelling. The obtained results are compared with mechanical behaviour of the natural bone and the previous bone scaffold compositions. The results indicated that, the modulus of elasticity, strength and toughness of the proposed composition of bone scaffold is very close to the natural bone behaviour with respect to the previous bone scaffold compositions and this composition can be employed as an appropriate replacement for bone implants.

PZT Impedance-based Damage Detection for Civil Infrastructures (토목 구조물의 PZT Impedance 기반 손상추정기법)

  • S. H. Park;Y. Roh;C. B. Yun;J. H. Yi
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2004.04a
    • /
    • pp.373-380
    • /
    • 2004
  • This paper presents the feasibility of an impedance-based damage detection technique using piezoelectric (PZT) transducers for civil infrastructures such as steel bridges. The impedance-based damage detection method is based on monitoring the changes in the electrical impedance. Those changes in the electrical impedance are due to the electro-mechanical coupling property of the piezoelectric material and structure. An effective integrated structural health monitoring system must include a statistical process of damage detection that is automated and real time assessment of damage in the structure. Once measured, damage sensitive features from this impedance change can be statistically quantified for various damage cases. The results of the experimental study on three kinds of structural members show that cracks or loosened bolts/nuts near the PZT sensors may be effectively detected by monitoring the shifts of the resonant frequencies. The root mean square (RMS) deviations of impedance functions between before and after damages were also considered as a damage indicator. The subsequent statistical methods using the impedance signature of the PZT sensors were investigated.

  • PDF

Accuracy improvement in motion tracking of tennis balls using nano-sensors technology

  • Shuning Yan;Chaozong Xiang;Li Guo
    • Advances in nano research
    • /
    • v.14 no.5
    • /
    • pp.409-419
    • /
    • 2023
  • Tracking the motion of tennis balls is a challenging task in using cameras around the tennis court. The most important instance of the tennis trajectory is the time of impact and touch the court which in some cases could not be detected precisely. In the present study, we aim to present a novel design of tennis balls equipped with nano-sensors to detect the touch of the ball to the court. In the impact instance, tennis ball receives significant acceleration and change in the linear momentum. This large acceleration could deform a small-beam structure with piezoelectric layer to produce voltage. The voltage could further be utilized to produce infrared waves which could be easily detected by infrared detection sensors installed on the same video cameras or separately near the tennis court. Therefore, the exact time of the impact could be achieved with higher accuracy than image analyzing method. A detailed dynamical property of such sensors is discussed using nonlinear beam equations. The results show that within the acceleration range of tennis ball during an impact, the piezoelectric patches of the nano-sensors in the tennis ball could produce enough voltages to propagate infrared waves to be detected by infrared detectors.

A Study on Self-Healing Bolted Joints using Shape Memory Alloy (형상기억합금을 이용한 자가치유 볼트접합부 시스템에 관한 연구)

  • Chang, Ha-Joo;Lee, Chang-Gil;Park, Seung-Hee
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.5
    • /
    • pp.629-636
    • /
    • 2011
  • This paper describes the smart structural system that uses smart materials for real-time monitoring and active control of bolted joints in steel structures. The impedance-based structural health monitoring (SHM) techniques, which utilize the electro-mechanical coupling property of piezoelectric materials, was used to detect loose bolts in bolted joints. By monitoring the measured electrical impedance and comparing it with the measured baseline, a bolt loosening damage was detected. The damage was evaluated quantitatively using the damage metrics in conductance signature with respect to the healthy states. When loosening damage was detected in the bolted joint, the external heater actuated the shape memory alloy (SMA) washer. Then the heated SMA washer expanded axially and adjusted the bolt tension to restore the lost torque. An experiment was conducted by integrating the piezoelectric-material-based SHM function and the SMA-based active control function on a bolted joint, after which the performance of thesmart self-healing joint system was investigated.

Modified Piezoelectric Ceramics for Portable Ultrasonic Medical Probe Application (휴대용 의료 초음파 프로브 적용을 위한 압전체 제조 및 특성)

  • Kang, Dong Heon;Chae, Mi Na;Hong, Se Won
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.8
    • /
    • pp.483-488
    • /
    • 2016
  • Ultrasound imaging by using piezoelectric materials, such as lead zirconium titanate (PZT) has been one of the most preferred modes of imaging in the medical field due to its simple, low cost and non-ionizing radiation in comparison to other imaging techniques. Recently, the market demand for portable ultrasound is becoming larger with applications in developing countries, disaster area, military, and emergency purposes. However, most of ultrasound probes used is bulky and high power consumable, so unsuitable for such applications. In this study, the 3 layered ceramic specimen consisted of 128 pitches of $420{\mu}m$ in width and $450{\mu}m$ in thickness were prepared by using the Ti-rich PZT compositions co-fired at $1,050^{\circ}C$. Their electrical and ultrasound pulse-echo properties were investigated and compared to the single layer specimen. The 3 layered ultrasound probe showed 1.584 V of Vp-p, which is 3.2 times higher than single layered one, implying that it would allow effectively such a portable ultrasound probe system. The result were discussed in terms of higher capacitance, lower impedance and higher dielectric coefficient of the 3 layered ultrasound probe.

Electro-Optical Characteristics and Analysis of 1×1 mm2 Large-Area InGaN/GaN Green LED (1×1 mm2 대면적 녹색 LED의 전기 광학적 특성 분석)

  • Jang, L.W.;Jo, D.S.;Jeon, J.W.;Ahn, Tae-Young;Park, M.J.;Ahn, B.J.;Song, J.H.;Kwak, J.S.;Kim, Jin-Soo;Lee, I.H.;Ahn, H.K.
    • Journal of the Korean Vacuum Society
    • /
    • v.20 no.4
    • /
    • pp.288-293
    • /
    • 2011
  • We investigated the effects of piezoelectric field on the electro-absorption characteristics in InGaN/GaN multiple-quantum well (MQW) green light emitting diodes (LED). Double crystal X-ray diffraction measurement was performed to study the crystalline property and indium (In) composition in the MQW active layer. To measure the electro-luminescence and electro-reflectance (ER) spectroscopy, we fabricated the $1{\times}1\;mm^2$ large-area green LED chip. The piezoelectric field inside the LED structure was evaluated from the Vcomp in active layer by the ER spectra. Finally, we analyzed the electro-absorption characteristics of the green LED by using the photo-current spectroscopy.

Effect of DyFeO3 Addition on Crystal Structure and Ferrcelectricity of the BiFeO3-PbTiO3 System

  • Kim, Seong-Seog;Kwon, Jong-Uk;Cheon, Chae Il
    • Journal of the Korean Ceramic Society
    • /
    • v.42 no.5 s.276
    • /
    • pp.299-303
    • /
    • 2005
  • The crystal structure and ferroelectricity of the $(1-x)BiFeO_3\;(BF)-xPbTiO_3$ (PT) ceramic system with the addition of $DyFeO_3$ (DF) have been investigated for attaining a high temperature piezoelectric material. This study is focused on the relation between crystal structure and ferroelectric property with the addition of DF over the phase boundary in the (1-x)BF-xPT system. Hysteresis curves of polarization-electric field at room temperature have been measured. The X-ray and neutron diffraction data were analyzed by the rietveld refinement method. The addition of 0.1 mole DF into BF-PT system greatly increases the ferroelectric remanant polarization Pr values, e.g. 17 ${\mu}C/cm^2$ in 0.6BF-yDF-(0.4-y)PT and 31${\mu}C/cm^2$ in 0.5BF-yDF-(0.5.y)PT, respectively. The improved Pr value has been discussed in relation with crystal structure and electrical property.

Characterization of the PVDF Fibers Fabricated by Hybrid Wet Spinning (하이브리드 습식 공정을 통한 PVDF 섬유의 제조 및 특성에 관한 연구)

  • Jeong, Kun;Kim, Seong-Su
    • Composites Research
    • /
    • v.29 no.4
    • /
    • pp.145-150
    • /
    • 2016
  • Polyvinylidene fluoride (PVDF) as a representative polymer with the piezoelectric property has been studied since the 1960s. Crystalline structure of poly(vinylidene fluoride) polymer is composed of five different crystal structure of the polymer as a semi-crystalline. Among the various crystal structures, ${\beta}-type$ crystal exhibits a piezoelectricity because the permanent dipoles are aligned in one direction. Generally ${\beta}-form$ crystal structure can be obtained through the transformation of the ${\alpha}-form$ crystal structure by the stretching and it can increase the amount through the after treatment as poling process after stretching. ${\beta}-form$ crystal structure the PVDF fibers produced by wet spinning is formed through a diffusion mechanism of a polar solvent in the coagulation bath. However, it has a disadvantage that the diffusion path of the solvent remains as pores in the fiber because the fiber solidification occurs simultaneously with the diffusion of the polar solvent. These pores play a role in reducing effect of poling process owing to effect of disturbances acting on the polarization by the electric field. In this work, the drying method using the microwave was introduced to remove more effectively the residual solvent and the pore within PVDF fibers produced through wet-spinning process and piezoelectric PVDF fibers was produced by transformation of the remaining ${\alpha}$ form crystal structure into ${\beta}-crystal$ structure through the stretching process.

Surface Acoustic Wave Sensor using Electroactive Paper (EAPap) (Electroactive Paper (EAPap)를 이용한 표면탄성파 센서)

  • Lee, Min-Hee;Kim, Joo-Hyung;Kim, Jae-Hwan
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.368-371
    • /
    • 2008
  • Cellulose based Electroactive Paper (EAPap) has been developed as a new smart material due to its advantages of piezoelectricity, large displacement, low power consumption, low cost and flexibility. EAPap can be used fur a surface acoustic wave (SAW) device using the piezoelectric property of EAPap, resulting in the cost effective and flexible SAW device. In this paper, inter digit transducer (IDT) structure using lift-off technique with a finger gap of $10{\mu}m$ was used for micro fabrication of the cellulose EAPap SAW devices. The performance of IDT patterned SAW device was characterized by a Network Analyzer. The feasibility of cellulose EAPap as a potential acoustic device was presented and explained.

  • PDF