• Title/Summary/Keyword: piezo film sensor

Search Result 27, Processing Time 0.02 seconds

A study on the optimum configuration of sensor part for measurement of pulse using piezo film sensor in brachial artery (Piezo Film Sensor를 이용하여 상완 동맥에서 맥박 측정을 위한 센서부 최적 구조에 관한 연구)

  • Jo, Sung-Hyun;Kim, Sheen-Ja;Lee, Young-Woo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.10a
    • /
    • pp.441-443
    • /
    • 2009
  • Piezo Film Sensor를 이용하여 팔뚝의 상완 동맥에서 맥박 측정을 위한 센서부 최적 구조에 관한 연구를 하였다. 탈부착이 쉬운 팔뚝형 밴드 형태에 Piezo Film Sensor를 삽입하여 생체 신호를 측정 하였다. 센서부의 최적 구조를 알기 위해서 센서패드 구조물의 형태에서 매질 및 두께를 변화시켜 가면서 생체 신호의 크기를 비교하였다.

  • PDF

Dispersive Wave Analysis of a Beam under Impact Load by Piezo-Electric Film Sensor and Wavelet Transform (충격하중을 받는 보에서 압전 필름센서와 웨이브렛 변환을 이용한 문산파동의 해석)

  • Kwon., Il-Bum;Choi, Man-Yong;Jeong., Hyun-Jo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.5 no.4
    • /
    • pp.215-225
    • /
    • 2001
  • Stress waves monitored on the surface of structures under various loading conditions can provide useful information on the structural health status. In this paper, stress waves are measured by several sensors when a steel beam is impacted by a ball drop. The sensors used include the piezo-electric film Sensor, the electrical strain gage, and the ultrasonic transducer, and special attention is given to the pieza film sensor. The wavelet transform is used for the time-frequency analysis of dispersive waves propagating in the beam. The velocities of the wave produced in the team due to the lateral impact is found to be frequency-dependent and identified as the flexural wave velocity based on the comparisons with the Timoshenko beam theory. A linear impact site identification method is developed using the flexural wave, and the impact sites of the beam can be accurately estimated by the piezo film sensors. It is found that the piezo film sensor is appropriate for sensing stress waves due to impact and for locating impact sites in the beam.

  • PDF

A Study on Detection of Elastic Wave Using Patch Type Piezo-Polymer Sensor (부착형 고분자 압전센서를 이용한 탄성파 검출 연구)

  • Kim, Ki-Bok;Yoon, Dong-Jin;Kueon, Jae-Hwa;Lee, Young-Seop
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.3
    • /
    • pp.268-274
    • /
    • 2004
  • Patch type piezo-polymer sensors for smart structures were experimented to detect elastic wave. The pencil lead braking test was performed to analyze the characteristics of patch-type piezo-polymer sensors such as polyvinyliden fluoride (PVDF) and polyvinylidene fluoride trifluorethylene (P(VDF-TrFE)) for several test specimens with various elastic wave velocities and acoustical impedances. The characteristics of the patch-type piezo-polymer sensor were compared with the commercial PZT acoustic emission (AE) sensor. The vacuum grease and epoxy resin were used as a couplant for the acoustic impedance matching between the sensor and specimen. The peak amplitude of elastic wave increased as the diameter of piezo-film and acoustical impedance of the specimen increased. The frequency detection range of the piezo-film sensors decreased with increasing diameter of the piezo-film sensor. The P(VDF-TrFE) sensor was more sensitive than the PVDF sensor.

Detection the Biomedical Information using the Piezo Film Sensor (Piezo Film Sensor를 이용한 생체 정보 검출)

  • Lee, H.W.;Seo, H.;Jeong, W.G.;Jang, D.B.;Lee, G.K.
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.3 no.3
    • /
    • pp.14-21
    • /
    • 2010
  • For the ubiquitous healthcare environment, real-time measurement of biomedical signals and accuracy of the measured biomedical information are very important. In addition, it is important to develop a healthcare device with low power In this paper, the synchronized pulse in a heartbeat was detected from the radial artery using the piezo film sensor, in order to eliminate inconvenience to wear a pulse detection finger probe. We can get a best output after applying the adaptive noise canceller using two piezo film sensor signals, pulse signal having motion artifacts and motion artifacts reference signal. To detect heartbeat, we use maximum point detection method from pulse removed motion artifacts.

  • PDF

Accuracy Analysis of Pulse Wave Sensor Data of Ear Label of Husbandry Livestock (축산 가축 이표용 맥파 센서의 데이터 정확도 분석)

  • Kim, Il-Gon;Kang, So-Hyung
    • Journal of Digital Convergence
    • /
    • v.12 no.11
    • /
    • pp.387-393
    • /
    • 2014
  • In this research, we aimed to investigate the most optimum pulse wave sensor to ear label of live stocks among pulse wave piezo film sensor, conductive textile sensor, photo sensor. As a result of this research with application to 10 cattle, 10 pigs objects with pulse wave piezo film sensor, conductive textile sensor, photo sensor, photo sensor shows less standard deviation to average value than piezo film sensor or conductive textile sensor which means it is the most stable for the cattle. With pigs, piezo film sensor, conductive textile sensor and photo sensor all show stable pulse rate. Thus, to take pulse rate of livestock with curved body and long and dense coat such as cow, photo sensor will be considered as the most efficient mean.

A Study on the Measurement of Oil-Film Pressure in Engine Connecting Rod Bearing and Piston Pin-Boss by Thin-Film Sensor

  • Mihara, Yuji;Someya, Tsuneo
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2002.10b
    • /
    • pp.409-410
    • /
    • 2002
  • In order to measure the oil-film pressure in sliding surface of machinery, we have developed a piezo-resistive type thin-film pressure sensor. To reduce the measurement error due to temperature and strain, the constituent of the pressure sensitive alloy was optimized and a new sensor shape was devised. In this study, we present the measurement results of the oil-film pressure distribution in engine connecting rod big-end bearing and piston pin- bosses with 3 different pin-boss shapes using the newly developed thin-film pressure sensor.

  • PDF

Fall detection of the elderly through floor vibrations (바닥 진동을 통한 노인 낙상 검출)

  • Kim, Dong-Wan;Ryu, Jong-Hyun;Beack, Seung-Hwa
    • Journal of IKEEE
    • /
    • v.18 no.1
    • /
    • pp.134-139
    • /
    • 2014
  • According to survey, more than 57.2% of the fall which is the most frequent safety accident of the elders takes place at home. This research aims to verify the fall by measuring and analyzing the floor vibration. And the vibration sensor module was designed with piezo film sensor and operation amplifier. The vibration signals are converted to digital signals through the data acquisition device and vibration sensor module. And then modified the signals into frequency domain to obtain characteristic vibration data. The characteristic signals are verified by K-Nearest Neighbor verification, and experimental results shows the recognition rate 93.6%. Also the fall detection sensor module is useful for extract the meaningful data for fall detection. 10 persons are participated for this experiment.

Study of Output Characteristics of Pressure T/D using Piezo Capacitor Type (Piezo-Capacitor방식 입력 Transducer와 출력특성 고찰)

  • Lee, Seong-Jae;Yoo, Byung-Ki
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.245-246
    • /
    • 2009
  • 정전용량형 후막 스트레인 게이지(piezocapacitive thick film strain gage)는 세라믹 ($Al_2O_3$)을 주 원료로 하는 지지대(약 5mm)와 다이어프램(약 $300{\mu}m$) 그리고 가드 링으로 구성된다. 전극 판은 도전성 페이스트를 이용하여 지지대와 다이어프램에 형성되었으며 극판 사이에는 유전체 메이스트를 사용하여 스크린 인쇄로 후막을 형성하였다. 극판 사이의 가드 링 두께는 약 $30{\mu}m$정도로 다이어프램의 변위 최대값을 유지시키는 데 필요한 간격이다. 따라서 정전용랑형 후막 스트레인 게이지는 지지대를 중심으로 다이어프램에 압력 (0.5~1.0bar)이 인가될 때 변위를 발생시키면서 커패시터 값이 압력의 크기에 따라 비례 특성을 가지고 변화하는 것을 이용한 것이다. 압력이 없을때 초기값은 35pF~40pF 정도이고 정격압력의 최대치를 인가시켰을 때 약 55pF~55p를 나타내었다.

  • PDF

Development of a Weight in Motion sensor using Piezo Film (피에조 필름을 이용한 축중감지기 개발)

  • Yang, Hui-Sun;Park, Yon-Kyu;Kang, Dae-Im;Kim, Am-Kee
    • Proceedings of the KSME Conference
    • /
    • 2000.11a
    • /
    • pp.262-267
    • /
    • 2000
  • This paper describes a weight in motion(WIM) sensor to measure the weight of a vehicle in motion. The main sensing element of the WIM sensor is the PVDF(Polyvinylidene fluoride) film that shows rapid response to an external excitation. Due to the property of rapid response, it is possible to measure the weight of a vehicle in motion with high speed. In the development of the WIM sensor, the dominant target value was the uniformity of the sensor. To increase the uniformity, We employed shrinkable tube made of rubber to enhance the uniformity, and performed the rolling of the brass tube repeatedly. The uniformity of the sensor was examined experimentally. It was comparable to that of a WIM sensor of the MSI which was the benchmark of this development. This paper also describes the mechanical modeling of the sensor and the suitable charge amplifier for the sensor.

  • PDF

The Developement of a Wind Direction/Speed Measurement Equipment Using RTD or Piezo Sensors (RTD 및 피에조 센서를 활용하는 풍향/풍속 측정장치 개발)

  • Joo, Jae-Hun;Kim, Dong-Hyun;Gong, Byung-Gunn;Lee, Jin-Ho;Choi, Jung-Keyng
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.05a
    • /
    • pp.827-830
    • /
    • 2011
  • In this paper, a wind speed & direction module and the DSP(Digital Signal Processor) sensor interface circuit board are proposed. This DSP system accepts and process the informations from a wind speed & direction module, the atmospheric pressure sensor, the ambient air temperature sensor and transfers it to the PC monitering system. Especially, a wind speed & direction module and a DSP hardware are directly designed and applied. A wind speed & direction module have a construction that it have four film type RTD(Resistive Temperature Detectors) or film type Piezo sensors adhered around the circular metal body for obtaining vector informations about wind. By this structure, the module is enabled precise measurement having a robustness about vibration, humidity, corrosion. A sensor signal processing circuit is using TMS320F2812 TI(Texas Instrument) Corporation high speed DSP.

  • PDF