• Title/Summary/Keyword: piezo

Search Result 713, Processing Time 0.024 seconds

Development of Scent Display Device using Micro-pore Piezo Actuator (마이크로 다공성 압전 진동자를 이용한 발향장치 설계)

  • Lee, Young-Joon;Lim, Seung-Ju;Kim, Min-Ku;Lee, Hae-Lyong;Kim, Jeong-Do
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.6
    • /
    • pp.399-405
    • /
    • 2016
  • Scent diffuser using micro-pore piezo actuator achieved a commercial success because of its cheap production cost, but it is easy to be use for IT-based contents due to difficulty of scent intensity control. To solve this problem, we control the emission amount of scent diffuser by changing amplitude and frequency of input voltage applied to micro-pore piezo actuator. And, we analyzed the effect of density of cotton core on emission amount and a relationship between hole-size of mesh in piezo actuator and viscosity of scents to design a mechanically optimal scent device.

A Study on the Piezo Injector Control Algorithm for CRDI Diesel Engines (커먼레일 디젤 엔진용 피에조 인젝터 제어에 관한 연구)

  • Oh, Byoung-Gul;Oh, Seung-Suk;Park, Yeong-Seop;Lee, Kang-Yoon;SunWoo, Myoung-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.2
    • /
    • pp.54-62
    • /
    • 2009
  • The purpose of this study is to develop a piezo injector driver for common-rail direct injection diesel engines. In this research, we analyzed the electrical and mechanical characteristics of the piezo actuator through experiments. Current flow and charging voltage of the piezo injector are controlled by the PWM signal of variable duty ratio in order to realize both fast response and low peak current. The optimal switching duty ratio was designed by modeling and analyzing of the piezo driver circuit. In order to avoid resonance and unacceptably long settling time, appropriate frequency range of the PWM signal was derived based on the driver circuit model. The developed injector driver was validated by experiments under various fuel rail pressure, injection duration, and charging voltage.

A Piezo-Driven Miniaturized XY Stage with Two Prismatic-Prismatic Joints Type Parallel Compliant Mechanism (2 개의 병진-병진 관절형 병렬 탄성 메커니즘을 갖는 압전구동 소형 XY 스테이지)

  • Choi, Kee-Bong;Lee, Jae Jong;Kim, Gee Hong;Lim, Hyung Jun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.12
    • /
    • pp.1281-1286
    • /
    • 2013
  • In this paper, a miniaturized stage with two prismatic-prismatic joints (2-PP) type parallel compliant mechanism driven by piezo actuators is proposed. This stage consists of two layers which are a motion guide layer and an actuation layer. The motion guide layer has 2-PP type parallel compliant mechanism to guide two translational motions, whereas the actuation layer has two leverage type amplification mechanisms and two piezo actuators to generate forces. Since the volume of the stage is too small to mount displacement sensors, the piezo actuators embedding strain gauge sensors are chosen. With the strain gauge-embedded piezo actuators, a semi-control is implemented, which results in hysteresis compensation of the stage. As the results, the operating range of $30{\mu}m$, the resolution of 20 nm, and the bandwidth of 400 Hz in each axis were obtained in the experiments.

Comparison Analysis of Dynamic Characteristics of Servo-hydraulic Piezo-driven Injector between 3-way and Bypass-circuit Type (3-way형과 Bypass형 서보유압 피에조 인젝터의 구동특성 비교)

  • Jo, Insu;Jeong, Myoungchul;Lee, Jinwook
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.21 no.5
    • /
    • pp.169-175
    • /
    • 2013
  • CRDi technology of diesel engine was developed from in the early 2000s due to a need to increase fuel efficiency and environment care. Especially, high-pressure fuel injection system in CRDi system which has a fuel injection unit including an injector, a fuel pump and common-rail, etc. becomes possible to make the exhaust gas clean as well as power improvement. In this study, comparison of dynamic characteristics of servo-hydraulic piezo-driven injector with 3-way and bypass-circuit type was analyzed by using the AMESim code. As results of this study, it found the bypass-circuit inside servo-hydraulic piezo injector can cause a faster injection response than that of the 3-way type. Also it was shown that bypass-circuit type had better control capability due to hydraulic bypass system.

Pilot Spray Characteristics of Piezo type Injectors for High Pressure Injection (고압 분사용 Piezo 인젝터의 Pilot 분무특성)

  • Bae, J.W.;Kim, H.N.;Lee, J.W.;Kang, K.Y.;Ryu, J.I.
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.2076-2081
    • /
    • 2004
  • Future exhaust gas limits for diesel-driven passenger cars will force the automotive industry to significantly improve the performance of engine. Since modern common-rail injection systems deliver more degrees of freedom referring to the injection process, again the optimization of the injection process could offer a possibility to meet the exhaust gas limits. This study describes the characteristic the pilot spray structure of piezo-driven injector for a passenger car common-rail system to be applicable multiple injection caused by fast response rather than solenoid-driven injector. The piezo-driven injector is prototype injector with same needle chamber of solenoid injector and the solenoid-driven one is commercial injector. The pilot spray characteristic such as spray tip penetration, spray speed, spray angle were obtained by spray images, which is measured by the Mie scattering method with optical system for high-speed temporal photography. It was found that piezo-driven injector effected electric change as important factor and showed faster response than solenoid-driven injector.

  • PDF

LIPUS Promotes Endothelial Differentiation and Angiogenesis of Periodontal Ligament Stem Cells by Activating Piezo1

  • Rui Hu;Zheng-yan Yang;Yue-heng Li;Zhi Zhou
    • International Journal of Stem Cells
    • /
    • v.15 no.4
    • /
    • pp.372-383
    • /
    • 2022
  • Background and Objectives: Low-intensity pulsed ultrasound (LIPUS) promotes differentiation and regulates biological functions of various stem cells, but its effect on the endothelial differentiation of periodontal ligament stem cells (PDLSCs) is unclear. This study investigated the effect of LIPUS on endothelial differentiation and angiogenesis in PDLSCs and the role of the mechanically sensitive ion channel Piezo1 in this process. Methods and Results: PDLSCs obtained from healthy people were used for endothelial induction, and 10 ㎍/ml lipopolysaccharide (LPS) was used to simulate the inflammatory state. The induced cells were treated with LIPUS (50 mW/cm2, 1.5 MHz) to study its effect on the endothelial differentiation of PDLSCs and the tube formation of differentiated cells. PCR, flow cytometry, immunofluorescence, and Matrigel tube formation assays were used to detect the differentiation and tube formation of PDLSCs. GsMTx4 was used to inhibit the expression of Piezo1, and the role of the Piezo1 pathway in the endothelial differentiation and microvascular formation of PDLSCs after LIPUS treatment was studied. The data showed that LIPUS increased endothelial differentiation and angiogenesis in PDLSCs under inflammatory or noninflammatory conditions. The use of an inhibitor weakened the effect of LIPUS. Conclusions: This study demonstrated that LIPUS can activate the expression of Piezo1 and promote the endothelial differentiation and microvascular formation of PDLSCs.

Detection the Biomedical Information using the Piezo Film Sensor (Piezo Film Sensor를 이용한 생체 정보 검출)

  • Lee, H.W.;Seo, H.;Jeong, W.G.;Jang, D.B.;Lee, G.K.
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.3 no.3
    • /
    • pp.14-21
    • /
    • 2010
  • For the ubiquitous healthcare environment, real-time measurement of biomedical signals and accuracy of the measured biomedical information are very important. In addition, it is important to develop a healthcare device with low power In this paper, the synchronized pulse in a heartbeat was detected from the radial artery using the piezo film sensor, in order to eliminate inconvenience to wear a pulse detection finger probe. We can get a best output after applying the adaptive noise canceller using two piezo film sensor signals, pulse signal having motion artifacts and motion artifacts reference signal. To detect heartbeat, we use maximum point detection method from pulse removed motion artifacts.

  • PDF

The Design of Piezo-driven mirror for the Path Length Control in a Ring Resonator (링 공명기의 경로치 제어를 위한 피에조 구동 거울의 설계)

  • Lee, Jeong-Ick
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.10
    • /
    • pp.2551-2556
    • /
    • 2009
  • The principal operation of a ring laser gyroscope depends on the phase difference for the counter-propagating waves within a closed path. The reflection mirrors mounted on the resonator block form the traveling waves. Thus, the dimension accuracy of resonator block influences the traveling path of beam. In order to maintain the stable optical beam path in the ring resonator, the piezo-driven moveable mirror is adopted for the path length control under the thermal expansion or mechanical strain of resonator block. This paper presents the mathematical description of the elastic behavior of piezo-driven mirror. This description can be applied for the concept design of piezo-driven mirror.

Computer Simulation and Control performance evaluation of Ultra Precision Positioning Apparatus using Piezo Actuator (Piezo Actuator를 이용한 초정밀 위치결정기구의 Computer Simulation 및 제어 성능평가)

  • 김재열;김영석;곽이구;한재호
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.118-122
    • /
    • 2000
  • Recently, High accuracy and precision are required in various industrial field especially, semiconductor manufacturing apparatus, Ultra precision positioning apparatus, Information field and so on. Positioning technology is a very important one among them. For composition of this technology, the development of system with high speed and high resolution is needed. At start point and end position vibration must be repressed on this system for composition of position control. This vibration is arisen nose, is increased setting time, is reduced accuracy. Especially, repressed for the lead with high speed. The small actuator with high speed and high resolution is need to repression against this residual vibration. This actuator is, for example, piezo actuator, piezoelectric material that converting from electronic signal to mechanical force is adequate material, beacause of control of control to position and force. In this study, piezo electric material is used to actuator, ultra precision positioning apparatus with stage of hinge structure is designed, simulation is performed, control performance is tested by producing apparatus. For easy usage and stability in industrial field, we perform to simulation and to position control test by digital PID controller.

  • PDF

Improvement for Response Delays of Displacement Magnifier in Jetting Dispenser (젯팅 디스펜서 변위확대장치의 응답지연 개선 연구)

  • Ha, Myeong-Woo;Lee, Kwang-Hee;Hong, Seung-Min;Lee, Chul-Hee
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.5
    • /
    • pp.546-551
    • /
    • 2016
  • The objective of this study is to investigate the response delays between piezo-stack actuator and the displacement magnifier of jetting dispenser and to reduce its falling time in terms of displacement optimization. The dispenser is driven by the dual piezo-stack actuators with a hinge lever mechanism to precisely control flow rate of the working fluid (3000 cP). It is commonly found that piezo actuator-driven jetting dispensers involving viscous working fluids have displacement optimization problem for ideal performance. The response delay of the system is caused by the phenomenon that the displacement magnifier cannot exactly follow the motion of the piezo actuators. The response delay may lower the performance of the system due to the inaccurate discharge of working fluid or even damages to the system itself due to inharmonious motion of piezo actuators with lever system. To reduce its response delay, a new displacement profile obtained from displacement optimization is suggested; its performance is tested through finite element analysis; and experiments are carried out to verify the performance of the obtained displacement profile.