• 제목/요약/키워드: physical measurement

검색결과 2,900건 처리시간 0.031초

The High Resistance Measurement up to 100 PΩ using a Low Resistance, a Low Voltage Source and a Commercial Digital Multimeter

  • Yu, Kwang Min;Lee, Sang Hwa;Kang, Jeon Hong;Kim, Wan-Seop
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권3호
    • /
    • pp.1392-1397
    • /
    • 2018
  • The potentiometric measurement result for a high resistance up to $100P{\Omega}$ using a low resistance, a low voltage source and a commercial digital multimeter(DMM) is presented. With the method, a resistance can be easily, fast and economically measured. Using the method, resistance ranges over the $10G{\Omega}$ range which is difficult to measure using a commercial DMM and resistance ranges between $100T{\Omega}$ and $100P{\Omega}$ which cannot measure using an insulation tester were measured within accuracy of a few percent. It is expected that it can be useful to determine the temperature and voltage effect of a high resistance and an insulation material because it uses a reference resistance with a low resistance, very low temperature and voltage effect. Besides, it is expected that it can be useful to calibrate a dc high voltage divider with a large resistance ratio and a very low resistance because arbitrary resistance ratio measurements are possible with it.

CNN 기법의 이미지 학습을 통한 팔굽혀펴기 자세 정확도 측정 (Measurement of Push-up Accuracy Using Image Learning by CNN)

  • 이준석;오동한;안경일
    • 한국멀티미디어학회논문지
    • /
    • 제24권6호
    • /
    • pp.805-814
    • /
    • 2021
  • Push-ups are one of the body exercises that can be easily measured anytime, anywhere. As one of the most widely used techniques as a test tool for evaluating physical strength, they are broadly used in various fields, especially in fields that require physical ability to estimate, such as military, police, and firefighters. However, social distancing is currently being implemented, and the issue of fairness has been steadily raised due to subtle differences between measurement. Accordingly, in this paper, the correct posture for each individual was photographed and learned by a high-performance computer, and the result was derived by comparing it with the case of performing the incorrect posture of the individual. If method is introduced into the physical fitness evaluation through the proposed method, the individual takes the correct posture and learns the photographed photo, and measures the posture with several images taken during a given time. Through this, it is possible to measure more objectively because it measures with the merit that can be measured even in the present situation and with one's correct posture.

뇌졸중 환자의 비마비측 슬관절 등척성 수축시 각도와 운동 방향이 마비측 대퇴사두근 활성도에 미치는 영향 (Effects of Angle and Direction of Maximal Isometric Contraction of Non-Hemiparetic Knee on Electromyographic Activity of Hemiparetic Quadriceps Femoris in Patients With Stroke)

  • 기경일;김선엽;오덕원;최종덕;김경환
    • 한국전문물리치료학회지
    • /
    • 제17권2호
    • /
    • pp.1-9
    • /
    • 2010
  • To develop effective training methods for strengthening a weakened quadriceps femoris muscle in hemiplegic patients, we examined the effects of maximal isometric contraction of the nonparalyzed knee joint on the electromyographic activities of the paralytic muscle. An electromyogram (EMG) was used to record the electromyographic activities of the paralytic quadriceps femoris muscle in 27 hemiplegic patients. The maximal isometric contraction was measured for each subject to normalize the electromyographic activities. The maximal isometric extension and flexion exercises were randomly conducted when the knee joint angles of the nonparalyzed knees were $0^{\circ}$, $45^{\circ}$, and $90^{\circ}$. The patients were encouraged to maintain maximal isometric contractions in both knee joints during each measurement, and three measurements were taken. A one-minute rest interval was given between each measurement to minimize the effects of muscle fatigue. An average from the three values was taken as being the root mean square of the EMG and was recorded as being the maximal isometric contraction. The electromyographic activity obtained for each measurement was expressed as a percentage of the reference voluntary contraction, which was determined using the values obtained during the maximal isometric contraction. The results of this study are summarized as follows: First, when the knee joint angle of the nonparalyzed knee was $0^{\circ}$, the electromyographic activities of the paralytic medial aspect of rectus femoris were related to measurement by a maximal isometric flexion exercise than by an extension exercise (p<.05). Second, when the knee joint angle of the nonparalyzed knee was $90^{\circ}$, the electromyographic activities of the paralytic lateral aspect of rectus femoris were related to measurement by a maximal isometric flexion exercise than by an extension exercise (p<.05). The results show that myoelectrical activities of paralytic quardriceps were not related to measurement angles and exercise directions of the nonparalized knee joint. Studies on various indirect intervention to improve muscular strength of patients with nervous system disorders of the weakened muscle should be constantly conducted.

Planar near-field antenna measurement method based on symplectic relation and reaction concept

  • Cho, Yong-Heui
    • International Journal of Contents
    • /
    • 제6권2호
    • /
    • pp.6-9
    • /
    • 2010
  • Using symplectic relation and reaction concept, we propose a planar near-field antenna measurement method. A generalized probe compensation equation is deduced to obtain the probe correction formulation. To verify our approach, a reflector antenna with $1{\times}2$ horn array is fabricated and measured in the near-field measurement facility. The near-field measurement results are compared with the physical optics (PO) simulation. The results of measurement and simulation agree very well near to the mainbeam.

Application of Decision Tree to Classify Fall Risk Using Inertial Measurement Unit Sensor Data and Clinical Measurements

  • Junwoo Park;Jongwon Choi;Seyoung Lee;Kitaek Lim;Woochol Joseph Choi
    • 한국전문물리치료학회지
    • /
    • 제30권2호
    • /
    • pp.102-109
    • /
    • 2023
  • Background: While efforts have been made to differentiate fall risk in older adults using wearable devices and clinical methodologies, technologies are still infancy. We applied a decision tree (DT) algorithm using inertial measurement unit (IMU) sensor data and clinical measurements to generate high performance classification models of fall risk of older adults. Objects: This study aims to develop a classification model of fall risk using IMU data and clinical measurements in older adults. Methods: Twenty-six older adults were assessed and categorized into high and low fall risk groups. IMU sensor data were obtained while walking from each group, and features were extracted to be used for a DT algorithm with the Gini index (DT1) and the Entropy index (DT2), which generated classification models to differentiate high and low fall risk groups. Model's performance was compared and presented with accuracy, sensitivity, and specificity. Results: Accuracy, sensitivity and specificity were 77.8%, 80.0%, and 66.7%, respectively, for DT1; and 72.2%, 91.7%, and 33.3%, respectively, for DT2. Conclusion: Our results suggest that the fall risk classification using IMU sensor data obtained during gait has potentials to be developed for practical use. Different machine learning techniques involving larger data set should be warranted for future research and development.

Test-retest Reliability and Concurrent Validity of a Headphone and Necklace Posture Correction System Developed for Office Workers

  • Gyu-hyun Han;Chung-hwi Yi;Seo-hyun Kim;Su-bin Kim;One-bin Lim
    • 한국전문물리치료학회지
    • /
    • 제30권3호
    • /
    • pp.174-183
    • /
    • 2023
  • Background: Office workers experience neck or back pain due to poor posture, such as flexed head and forward head posture, during long-term sedentary work. Posture correction is used to reduce pain caused by poor posture and ensures proper alignment of the body. Several assistive devices have been developed to assist in maintaining an ideal posture; however, there are limitations in practical use due to vast size, unproven long-term effects or inconsistency of maintaining posture alignment. We developed a headphone and necklace posture correction system (HANPCS) for posture correction using an inertial measurement unit (IMU) sensor that provides visual or auditory feedback. Objects: To demonstrate the test-retest reliability and concurrent validity of neck and upper trunk flexion measurements using a HANPCS, compared with a three-dimensional motion analysis system (3DMAS). Methods: Twenty-nine participants were included in this study. The HANPCS was applied to each participant. The angle for each action was measured simultaneously using the HANPCS and 3DMAS. The data were analyzed using the intraclass correlation coefficient (ICC) = [3,3] with 95% confidence intervals (CIs). Results: The angular measurements of the HANPCS for neck and upper trunk flexions showed high intra- (ICC = 0.954-0.971) and inter-day (ICC = 0.865-0.937) values, standard error of measurement (SEM) values (1.05°-2.04°), and minimal detectable change (MDC) values (2.92°-5.65°). Also, the angular measurements between the HANPCS and 3DMAS had excellent ICC values (> 0.90) for all sessions, which indicates high concurrent validity. Conclusion: Our study demonstrates that the HANPCS is as accurate in measuring angle as the gold standard, 3DMAS. Therefore, the HANPCS is reliable and valid because of its angular measurement reliability and validity.

An Innovative Wellness Program Promoting Participation in Physical Activity of Community-Dwelling Frail Elderly

  • Choi, Bong-sam
    • 한국전문물리치료학회지
    • /
    • 제24권3호
    • /
    • pp.47-56
    • /
    • 2017
  • Background: Given the potential benefits of wellness programs promoting physical activity of the community-dwelling frail elderly, it is recommended that comprehensive wellness programs combined with the component of physical activity. This may improve overall health and potentially lower the health care cost of the frail elderly. In general, the frail elderly residing in community or those after being discharged from hospitals are often committed to enhancing the status of participation in physical activity. Objects: The purposes of this study were to identify specific shortcomings of current wellness programs as part of continuum of community rehabilitation services and to propose alternatives for the care of the community-dwelling frail elderly. Through this study, geriatric health care professionals may be able to implement assessments and programs to successfully promote an effective continuum of care for the frail elderly. Methods: Article reviews were summarized and evaluated. Results: A model elaborating the relationship between components of successful wellness program and participation in physical activities for the community-dwelling frail elderly are recommended. First, periodic monitoring the levels of physical activity by the use of online measurement system should be considered. Second, individualized adaptive technologies for selecting optimal physical activities for the elderly may be better fit to individuals' current status of physical activity. Conclusion: The current status of physical activity in community-dwelling frail elderly can be monitored by online assessment systems. Through the innovative measurement system, elderly may assess his/her physical activity status overtime, select optimal physical activities matching the status, and create the elderly's own adaptive wellness programs that match to the status while residing in his/her community.

Relation between Weight Bearing Ratio in the Standing Posture Immediately after Performing Standing Task and Balance and Functional Ambulation in Stroke Patients

  • Hwang, Da-Gyeom;Kim, Joong-Hwi
    • The Journal of Korean Physical Therapy
    • /
    • 제27권5호
    • /
    • pp.320-324
    • /
    • 2015
  • Purpose: The purpose of this study was to provide methods for assessment of functional balance through study of correlation with the weight bearing ratio, functional balance, and functional gait on patients with stroke. Methods: Thirty-nine patients with stroke participated in this study. The timed up and go test was used to measure balance and the functional ambulation category test to measure functional gait. Weight bearing was measured in the quiet standing posture and weight bearing in the quiet standing posture immediately after performing the standing-task. Results: Both timed up and go test and functional ambulation category test showed significant correlation with balance in the quiet standing posture immediately after performing the standing task. Conclusion: Measurement of balance in the quiet standing posture immediately after performing the standing-task was considered a meaningful scale for measurement of both balance function and gait function of patients with stroke.

미끄럼 바닥에서 안정성 유지를 위한 균형 전략과 평가방법 (Measurement and Strategies for Dynamic Stability During Locomotion on a Slippery Surface)

  • 김택훈;윤두식
    • 한국전문물리치료학회지
    • /
    • 제10권1호
    • /
    • pp.97-108
    • /
    • 2003
  • Slipping during various kinds of movement often leads to potentially dangerous incidents of falling. The purpose of this paper was to review some of the research performed in the field including such topics as rating scales for balance, kinematics and kinetics of slipping, adaptation to slippery conditions, postural and balance control, and protective movement during falling. Controlling slipping and fall injuries requires a multifaceted approach. Environmental conditions (state of floor surface, tidiness, lighting, etc), work task (walking, carrying, pushing, lifting, etc), and human behavior (anticipation of hazards, adaptation to risks, risk taking, etc) must be accounted for in the assessment of slip and fall-related risks. Future directions of research must deal with modeling of basic tribophysical, biomechanical, and postural control process involved in slipping and falling.

  • PDF

편측 장골이 후방 회전된 여성의 보행분석 : 임상 사례보고 (A Gait Analysis of the Women with Unilateral Posterior Rotated Ilium : A Clinical Case Report)

  • 양경혜
    • 대한정형도수물리치료학회지
    • /
    • 제20권1호
    • /
    • pp.27-34
    • /
    • 2014
  • Background: The purpose of this clinical case report is to confirm sacroiliac joint misalignment effects on the gait. Methods: A healthy women volunteered to participate in this case report. Measurement of the subject was performed two categories. One is physical examination of the pelvic by inspection, palpation, movement based tests and pain provocation tests. The other one is gait performance measurement by 3 dimentional motion analysis. Results: Diagnosis by physical examination of the subject was Lt. ilium posterior rotation. Pelvic, hip, knee and ankle in the 3 dimensional kinematic data, the most notable result was the ankle. Conclusion: To confirm the effect of the misalignment of the sacroiliac joint on the gait function, it must be evaluated by integrating the movement to the ankle from the lumbar.