The lumbrical muscles contribute to the intrinsic plus position, that is simultaneous metacarpophalangeal (MCP) flexion and interphalangeal (IP) extension. The strength of the lumbrical muscles is necessary for normal hand function. However, there is no objective and efficient method of strength measurement for the lumbrical muscles. In addition, previous studies have not investigated the measurement of the cross-sectional area (CSA) of the lumbrical muscles using ultrasonography (US) and the relationship between lumbrical muscle strength in the intrinsic plus position and the CSA. Therefore, the purpose of this study was to identify the measurement method of the CSA of the lumbrical muscles using US and to examine the relationship between maximal isometric strength and the CSA of lumbrical muscles. Nine healthy males participated in this study. Maximal isometric strength of the second, third, and fourth lumbrical muscles was assessed using a tensiometer in the intrinsic plus position which isolated MCP flexion and IP extension. The CSA of the lumbrical muscles was measured with an US. The US probe was applied on the palmar aspect of the metacarpal head with a transverse view of the hand in resting position. There was no significant difference between maximal isometric strength of the lumbrical muscles, but the fourth lumbrical muscle was stronger than the others. The CSA of the lumbrical muscles was significantly different and the fourth lumbrical muscle was significantly larger than the second lumbrical muscle. There was moderate to good correlation between maximal isometric strength and the CSA of the lumbrical muscles. Therefore, we conclude that maximal isometric strength of the lumbrical muscles was positively correlated to the CSA of the lumbrical muscle in each finger, while the measurement of the CSA of the lumbrical muscles, using US protocol in this study, was useful for measuring the CSA of the lumbrical muscles.
Lim, Ji Young;Lee, Se-Yeong;Jung, Seung-Hwa;Park, Dae-Sung
대한물리의학회지
/
제16권2호
/
pp.45-52
/
2021
PURPOSE: This study examined the imaging procedure of pectoralis minor muscle thickness and assessed the intra- and inter-rater reliability of the muscle thickness measured by two raters using rehabilitative ultrasound imaging (RUSI) in healthy individuals. METHODS: Fifteen participants (aged 21 - 28, seven females, and eight males) were involved in the study. The primary rater palpated the coracoid process and the fourth rib, defined as the width of the index finger lateral to the sternum to avoid breast tissues, and lined the two landmarks. The second examiner checked 1 / 3 (1st point) and 1 / 2 (2nd point) of the line length as measurement points. The two raters obtained right side muscle images of the participants at a standardized sitting position using RUSI with a 7.5 MHz linear transducer at 40mm depth. For intra-rater reliability, the principal rater took three images per point and tried to take one more with an interval. For the inter-rater reliability, the other rater performed the same tasks as the principal rater on the same day. The reliability was analyzed using the intra-class correlation coefficient (ICC), the standard error of the measurement (SEM), and Bland and Altman plots. RESULTS: The reliability at all points was excellent for the same rater (ICC3,1 = .973 - .978, SEM = .042 - .046), and between raters (ICC2,1 = .939 - .959, SEM = .059 - .097). CONCLUSION: These findings show that the RUSI could be reliable for examining the pectoralis minor muscle thickness in healthy individuals at all measurement sites.
Background: This study was carried out to investigate the effect of mulligan taping group and repeated measurement group on muscle activity and grip strength of adult with forward head posture. Methods: Thirty adults with forward head posture were randomly assigned to each of 15 mulligan taping and repeat measurement groups. The mulligan taping group measured the pre-test and post-test muscle activity and the grip strength three times and compared the mean values. The repeat group was repeatedly measured and measured before and after the experiment, The collected data were analyzed using SPSS statistical program. Results: There was no significant difference between mulligan taping group and repeated measurement group in changes of muscle activity. There was a significant difference between mulligan taping group and repeated measurement group in changes of grip strength. Conclusions: Mulligan taping was applied to an adult with forward head posture, there was no significant change in muscle activity of flexor carpi radialis and palmaris longus, but it seems to improve hand function by re-aligned of nearby muscles by maintaining scapular stability.
The research is focused on relationship between body fat percentage and physical characteristics of women in age group between 20s and 30s who experience great deal of physical change such as marriage, pregnancy, delivery, breast-feeding, and etc. The research used physical measurement of two hundreds women: 50 women in their early twenties, 50 women in their late twenties, 50 women in their early thirties, and 50 women in their late thirties. The research provides base data for women clothing industry by observing relationship between physical figure and body fat percentage rate based on obesity study on body fat percentage, physical BMI, R$\ddot{o}$hrer Index, and Vervaeck Index. Followings are conclusion of the research. The older the ages, the shorter the height and the heavier the weight. Recognizable differences in circumference, thickness, and width rather than in length are found. Also recognizable increases in average body fat percentage and average physical characteristics by age have found. By observing body fat percentage and physical measurements, it was revealed that weight has more effect on body fat percentage than height in all ages. Circumference, width, and thickness have more impact than length measurements among physical measurements. Main body or upper body has more impact than legs and arms or lower body. Body fat percentage increase rapidly by ages. 2.0% of age 20~24, 20.0% of age 25~29, 28.0% of age 30~34, and 54.0% of age 35~39 were sorted as obesity.
Objective: This study aimed to evaluate the validity of a depth camera-based system for monitoring physical function, assessing its feasibility for accurately monitoring activities of daily living. Design: A cross-sectional study. Methods: Twenty-three participants were enlisted to perform fifteen activities of daily living within a living laboratory designed to simulate a home environment. Activities were monitored using a depth camera system capable of classifying actions into standing, sitting, and lying down, with a conventional video camera employed for activity recording. The duration of each activity, as measured by the system, was compared to direct observations made by a physical therapist which were analyzed using a motion analysis software. The association between these two measurement approaches was assessed through correlation analysis, coefficient of determination, intraclass correlation coefficient (ICC), and Bland-Altman plots. Results: Our findings indicated that standing activities exhibited the highest correlation (r=0.847) between the system measurements and physical therapist observations, followed by sitting (r=0.817) and lying down (r=0.734), which demonstrated lower correlations. However, the ICC and Bland-Altman plots revealed notable variances between the two measurement methods, particularly for activities involving lying down. Conclusions: In this study, the depth camera-based physical monitoring system showed promise feasibility in distinguishing standing, sitting, and lying down activities at home environments. However, the current study also underlined some necessities of enhancements in capturing lying down activities.
Methods for measuring the physical workload of construction workers are classified into posture assessment techniques (i.e., OWAS, RULA, etc.) and physiological measurement techniques (i.e., EMG, heart rate, etc.). The one does not quantify the workload on a specific body part of a worker by considering the weight of the hand tools or materials on hand and time for holding a particular posture. This paper presents a procedure for evaluating a physical demand using the electromyography (EMG) sensor. This study compares the EMG measurement and the posture assessment. The case study is carried out on a masonry operation.
The magnetic field standards, facilities and capabilities available at NPL for the calibration of magnetometers and gradiometers and the measurement of the magnetic properties of materials will be introduced. The details of the low magnetic field facility will be explained and the capabilities this facility enables for the characterisation and calibration of ultra-sensitive room temperature magnetic sensors will be presented. Building on core material capabilities that are compliant with the IEC 60404 series of written standards, the example of a standard permeameter that has been modified for the measurement of strips for real world conditions is discussed. This was incorporated into a stress machine to measure the DC properties of the soft magnetic materials used by the partners of a collaborative industry led R&D project at stress levels of up to 700 MPa. The results for three materials are presented and the changes in the properties with applied stress compared to establish which material exhibits favourable properties.
Thoracic kyphosis is occasionally used to describe someone with accentuated thoracic curvature, hyperkyphosis is preferred since kyphosis itself refers to the normal sagittal angle of thoracic curvature. The angle of thoracic kyphosis tends to increase with age resulting in hyperkyphosis in some individuals. The persons who suffer from hyperkyphosis are at increased risk for a variety of adverse health outcomes that include musculoskeletal alteration, physical functional limitations, poor quality of life, falls, and even earlier mortality. Hyperkyphosis may develop from vertebral fractures, degenerative disc disease, either muscle weakness, decreased mobility and sensory deficits. The gold-standard orthopaedic technique for assessment of thoracic kyphosis is standing lateral spine radiographs. Other clinical measures are Debrunner kyphometer, inclinometer, flexicurve ruler, arcometer, flexible electrogoniometer and spinal mouse.
Purpose: This study examined the effect of Kettle bell swing exercise on the body composition and lower limb muscular activity. Methods: As subjects, 26 normal adults in their twenties were divided randomly into the experiment group (n=13), in which Kettle bell exercise was applied, and the control group (n=13), in which bar exercise was applied. Both groups participated in the interventions for eight weeks with three sessions per week. Each group was assessed before training and four and eight weeks into the training to determine the effects of training intervention within and between the groups. The body composition was measured with a body composition analyzer. The changes in muscle activity were measured with a surface electromyography. An independent t-test was conducted to test the significance between the groups according to the measurement points and Repeated measured ANOVA was performed to compare the groups according to the periods with the statistical significance level set to ${\alpha}=0.05$. Results: No significant changes to the main effects of time and the interactions of time according to the measurement points were observed in the Kettle bell and control groups in the body composition (p>0.05). The muscular activity of both muscles were significantly different between the Kettle bell and control groups according to the measurement points with the exception of the right lateral gastrocnemius muscle (p<0.05). Conclusion: These findings suggest that Kettle bell swing exercise can have positive effects on the development of lower limb muscles.
Purpose: The purpose of the present study was to investigate the effects of the contact-relax (CR) intervention on pelvic alignment in subjects with habitual poor posture. Methods: Fifteen subjects who have habitual poor posture participated in this study. The subjects received an intervention inducing pelvic posterior depression with the elevated pelvic side. Pre- and post-intervention, and two weeks after intervention, the pelvic alignment was measured with a palpation meter (PALM) and a three-dimensional diagnostic imaging system. Results: Measuring with PALM, the pelvic height and anterior tilt angle were significantly decreased immediately after and were still decreased two weeks after intervention, compared to the pre-measurement (p<0.05). Three-dimensional pelvic alignment was also significantly different between measurement points, while the pelvic position (pelvic lateral tilt) was significantly decreased after intervention (p<0.05). Conclusion: By applying the intervention generating CR on an elevated pelvis, frontal pelvic alignment can be improved.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.