• Title/Summary/Keyword: physical measurement

Search Result 2,906, Processing Time 0.026 seconds

Comparison of the Tongue-Palate Pressure Patterns According to the Tongue Pressure in Community-Dwelling Older Adults

  • Min-Ji Jo;Soo-Min Kim;Seong-Chan Park;Hye-Jin Park;Yun-Seon Lee;Tae-Woo Kim;Ji-Seon Hong;Eui-Yeon Lee;Sung-Hoon Kim;Sun-Young Han
    • Journal of dental hygiene science
    • /
    • v.23 no.4
    • /
    • pp.320-329
    • /
    • 2023
  • Background: Oral frailty has garnered considerable interest following its identification as a risk factor for physical frailty. The Korean oral frailty diagnosis criteria have emphasized the need for extensive research on oral frailty diagnostic items and interventions. Our study performed an in-depth analysis of the tongue-palate pressure patterns in healthy community-dwelling older adults. Methods: Of the 217 older adults aged ≥60 years who visited a senior center in Wonju, 205 participants who completed tongue pressure measurement were included in the final analysis. Pressure changes over time were recorded by instructing the participants to press their tongue against the hard palate with for 7 seconds per cycle. The participants were divided into the normal and abnormal tongue pressure (NTP and ATP, respectively) groups based on whether they achieved the target tongue pressure at least once; tongue pressure patterns were compared between the groups. Furthermore, the average time taken to achieve the standard tongue pressure value was calculated for the participants in the NTP group and used to evaluate the decrease in tongue pressure in the ATP group. Results: Among the 205 participants, 40.5% had ATP. The tongue pressure graph revealed a gentle and consistent incline that was maintained even after achieving standard tongue pressure in the NTP group. The graph was more extreme in the ATP group, and the changes in the pressure type varied across individuals; the tongue pressure was only 48.4%, 40.7%, 31.9%, and 22.6% of the NTP in the participants in their 60s, 70s, 80s, and ≥90s, respectively (p<0.05). Conclusion: Tongue pressure weakness was observed in 40.5% of the healthy community-dwelling older adults. Furthermore, ATP graphs were observed in the patients with tongue pressure weakness. Thus, activities improving the oral function in community-dwelling older adults and systematic oral rehabilitation programs should be devised to promote normal swallowing.

Opto-Mechanical Detailed Design of the G-CLEF Flexure Control Camera

  • Jae Sok Oh;Chan Park;Kang-Min Kim;Heeyoung Oh;UeeJeong Jeong;Moo-Young Chun;Young Sam Yu;Sungho Lee;Jeong-Gyun Jang;Bi-Ho Jang;Sung-Joon Park;Jihun Kim;Yunjong Kim;Andrew Szentgyorgyi;Stuart McMuldroch;William Podgorski;Ian Evans;Mark Mueller;Alan Uomoto;Jeffrey Crane;Tyson Hare
    • Journal of The Korean Astronomical Society
    • /
    • v.56 no.2
    • /
    • pp.169-185
    • /
    • 2023
  • The GMT-Consortium Large Earth Finder (G-CLEF) is the first instrument for the Giant Magellan Telescope (GMT). G-CLEF is a fiber feed, optical band echelle spectrograph that is capable of extremely precise radial velocity measurement. G-CLEF Flexure Control Camera (FCC) is included as a part in G-CLEF Front End Assembly (GCFEA), which monitors the field images focused on a fiber mirror to control the flexure and the focus errors within GCFEA. FCC consists of an optical bench on which five optical components are installed. The order of the optical train is: a collimator, neutral density filters, a focus analyzer, a reimager and a detector (Andor iKon-L 936 CCD camera). The collimator consists of a triplet lens and receives the beam reflected by a fiber mirror. The neutral density filters make it possible a broad range star brightness as a target or a guide. The focus analyzer is used to measure a focus offset. The reimager focuses the beam from the collimator onto the CCD detector focal plane. The detector module includes a linear translator and a field de-rotator. We performed thermoelastic stress analysis for lenses and their mounts to confirm the physical safety of the lens materials. We also conducted the global structure analysis for various gravitational orientations to verify the image stability requirement during the operation of the telescope and the instrument. In this article, we present the opto-mechanical detailed design of G-CLEF FCC and describe the consequence of the numerical finite element analyses for the design.

Dissolved Methane Measurements in Seawater and Sediment Porewater Using Membrane Inlet Mass Spectrometer (MIMS) System (Membrane Inlet Mass Spectrometer (MIMS) 시스템을 이용한 해수 및 퇴적물 공극수내 용존 메탄의 측정)

  • An, Soon-Mo;Kwon, Ji-Nam;Lim, Jea-Hyun;Park, Yun-Jung;Kang, Dong-Jin
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.12 no.3
    • /
    • pp.244-250
    • /
    • 2007
  • Membrane inlet mass spectrometer (MIMS) has been used to accurately quantify dissolved gases in liquid samples. In this study, the MIMS system was applied to measure dissolved methane in seawater and sediment porewater. To evaluate the accuracy of the measurement, liquid samples saturated with different methane partial pressure were prepared and the methane concentrations were quantified with the MIMS system. The measured values correspond well with the expected values calculated from solubility constants. The standard error of the measurements were $0.13{\sim}0.9%$ of the mean values. The distribution of dissolved methane concentration in seawater of the South Sea of Korea revealed that the physical parameters primarily control the methane concentration in sea water. The MIMS system was effective to resolve the small dissolved methane difference among water masses. The probe type inlet in MIMS system was proven to be effective to measure porewater methane concentration.

Analysis of mechanical properties of secondary concrete products using CO2 captured material (이산화탄소 고정 탄산화물을 적용한 콘크리트 2차 제품의 기초 특성 분석)

  • Hye-Jin Yu;Sung-Kwan Seo;Kuem-Dan Park;Hyuk-Joon Kwon;Jeong-Hwan Kim
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.34 no.2
    • /
    • pp.66-72
    • /
    • 2024
  • In this study, the applicability of CCMs (Carbondioxide conversion capture materials) manufactured by reacting carbon dioxide gas with DG (Desulfurization gypsum) as a cement substitute for secondary concrete products were evaluated and the basic physical properties of CCMs-mixed mortar and concrete specimens were measured to derive the optimal mixing ratio. The main chemical oxides of CCMs were CaO and SO3, and the main crystalline phases were CaSO4·2H2O, Ca(OH)2, CaCO3, and CaSO4. In addition, by the results of particle size analysis and heavy metal measurement, the applicability of CCMs as a cement substitute for secondary concrete products was confirmed. As a result of measuring the strength behavior using mortar and concrete specimens with CCMs, the compressive and flexural strength decreased as the mix ratio of CCMs increased, but requirements by the standards for interlocking blocks and retaining wall blocks, which are target products in this study, were satisfied up to the optimal mixing ratio of 10 wt.% substitution. Therefore, its applicability as a cement substitute for secondary concrete products was confirmed.

Muscle Fiber, Connective Tissue and Meat Quality Characteristics of Pork from Low Birth Weight Pigs as Affected by Diet-Induced Increased Fat Absorption and Preferential Muscle Marbling

  • Bimol C. Roy;Patience Coleman;Meghan Markowsky;Kun Wang;Yongbo She;Caroline Richard;Spencer D. Proctor;Heather L. Bruce
    • Food Science of Animal Resources
    • /
    • v.44 no.1
    • /
    • pp.51-73
    • /
    • 2024
  • This study investigated how birth weight differences in piglets affected carcass and muscle fiber properties as well as meat quality at slaughter. Within litters, piglets were grouped according to their birth weight as either normal (NBW; 1.62-1.73 kg) or low (LBW; 1.18-1.29 kg). At 5 weeks of age, NBW piglets were randomly transitioned to control (C) or isocaloric high fat diets derived from non-dairy (HF), while LBW piglets were randomly transitioned to high fat diets derived from non-dairy (HF) or dairy sources (HFHD). Piglets were reared in individual pens under standardized housing and feeding conditions. Live weight was recorded weekly, and pigs were slaughtered at 12 weeks of age. Hot carcass weights, dressing percentages, lean meat yield, and primal cut proportions were determined. The m. longissimus thoracis was collected from the right side of the carcass for measurement of physical and chemical properties of meat and muscle fiber characteristics. Results indicated that LBW pigs compensated for their live weight compared to NBW pigs at 6 weeks of age. The mean muscle fiber diameter of LBW-HFHD group is significantly higher than NBW-C and NBW-HF group, and the type I muscle fiber diameter is significantly higher than NBW-C group. Dairy fat inclusion in LBW pig diet reduced carcass back fat thickness. This increased the calculated lean meat yield to be comparable to that of NBW pigs fed a commercial diet. Incorporating dairy-sourced high-fat into LBW pigs' diets appears to be an effective strategy for producing carcasses equivalent to NBW pigs.

Developing Measurement Items for the Service Quality of Clinical Trials based on the Brady & Cronin Model (Brady & Cronin의 모델에 기반한 임상시험 서비스 질 측정 문항 개발)

  • Go-Eun Lee;Sanghee Kim;Sue Kim;Sang Hui Chu;Jeong-Ho Seok;So Yoon Kim
    • The Journal of KAIRB
    • /
    • v.6 no.1
    • /
    • pp.17-31
    • /
    • 2024
  • Purpose: This study aims to develop preliminary items for measuring the perceived service quality of clinical trials among participants and to verify content validity. Methods: This study was designed as a methodological study. A conceptual framework was established based on Brady and Cronin's hierarchical model, and preliminary items were prepared through translation-back-translation, a review of existing instruments, and in-depth interviews with clinical trial participants and clinical research coordinators. The final items were completed through content validity testing by experts and a review of items by clinical trial participants for the prepared preliminary items. Results: Through this study, a set of 58 items across four domains (quality of interaction with researchers, the physical environment, performance procedures, and performance results) and 9 components (information·education·communication, trust, respect for participant preferences, securing facilities and space, accessibility, comfortability, informed consent, coordination of care, subjective understanding of clinical trials) on the service quality of clinical trials were completed. The scale content validity index of all preliminary items was 0.96, meeting the recommended standards. The individual-item content validity index also meets the recommended criteria for most items, excluding four items. Conclusion: This study holds significance in developing items to measure the quality of clinical trial execution from the perspective of participants. By verifying the reliability and validity of these items through subsequent research, it is expected that they can be utilized as a valuable instrument to devise strategies for improving the quality of clinical trials.

  • PDF

Deep Learning-based UWB Distance Measurement for Wireless Power Transfer of Autonomous Vehicles in Indoor Environment (실내환경에서의 자율주행차 무선 전력 전송을 위한 딥러닝 기반 UWB 거리 측정)

  • Hye-Jung Kim;Yong-ju Park;Seung-Jae Han
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.13 no.1
    • /
    • pp.21-30
    • /
    • 2024
  • As the self-driving car market continues to grow, the need for charging infrastructure is growing. However, in the case of a wireless charging system, stability issues are being raised because it requires a large amount of power compared with conventional wired charging. SAE J2954 is a standard for building autonomous vehicle wireless charging infrastructure, and the standard defines a communication method between a vehicle and a power transmission system. SAE J2954 recommends using physical media such as Wi-Fi, Bluetooth, and UWB as a wireless charging communication method for autonomous vehicles to enable communication between the vehicle and the charging pad. In particular, UWB is a suitable solution for indoor and outdoor charging environments because it exhibits robust communication capabilities in indoor environments and is not sensitive to interference. In this standard, the process for building a wireless power transmission system is divided into several stages from the start to the completion of charging. In this study, UWB technology is used as a means of fine alignment, a process in the wireless power transmission system. To determine the applicability to an actual autonomous vehicle wireless power transmission system, experiments were conducted based on distance, and the distance information was collected from UWB. To improve the accuracy of the distance data obtained from UWB, we propose a Single Model and Multi Model that apply machine learning and deep learning techniques to the collected data through a three-step preprocessing process.

Functional beamforming for high-resolution ultrasound imaging in the air with random sparse array transducer (고해상도 공기중 초음파 영상을 위한 기능성 빔형성법 적용)

  • Choon-Su Park
    • The Journal of the Acoustical Society of Korea
    • /
    • v.43 no.3
    • /
    • pp.361-367
    • /
    • 2024
  • Ultrasound in the air is widely used in industry as a measurement technique to prevent abnormalities in the machinery. Recently, the use of airborne ultrasound imaging techniques, which can find the location of abnormalities using an array transducers, is increasing. A beamforming method that uses the phase difference for each sensor is used to visualize the location of the ultrasonic sound source. We exploit a random sparse ultrasonic array and obtain beamforming power distribution on the source in a certain distance away from the array. Conventional beamforming methods inevitably have limited spatial resolution depending on the number of sensors used and the aperture size. A high-resolution ultrasound imaging technique was implemented by applying functional beamforming as a method to overcome the geometric constraints of the array. The functional beamforming method can be expressed as a generalized beam forming method mathematically, and has the advantage of being able to obtain high-resolution imaging by reducing main-lobe width and side lobes. As a result of observation through computer simulation, it was verified that the resolution of the ultrasonic source in the air was successfully increased by functional beamforming using the ultrasonic sparse array.

A method for localization of multiple drones using the acoustic characteristic of the quadcopter (쿼드콥터의 음향 특성을 활용한 다수의 드론 위치 추정법)

  • In-Jee Jung;Wan-Ho Cho;Jeong-Guon Ih
    • The Journal of the Acoustical Society of Korea
    • /
    • v.43 no.3
    • /
    • pp.351-360
    • /
    • 2024
  • With the increasing use of drone technology, the Unmanned Aerial Vehicle (UAV) is now being utilized in various fields. However, this increased use of drones has resulted in various issues. Due to its small size, the drone is difficult to detect with radar or optical equipment, so acoustical tracking methods have been recently applied. In this paper, a method of localization of multiple drones using the acoustic characteristics of the quadcopter drone is suggested. Because the acoustic characteristics induced by each rotor are differentiated depending on the type of drone and its movement state, the sound source of the drone can be reconstructed by spatially clustering the results of the estimated positions of the blade passing frequency and its harmonic sound source. The reconstructed sound sources are utilized to finally determine the location of multiple-drone sound sources by applying the source localization algorithm. An experiment is conducted to analyze the acoustic characteristics of the test quadcopter drones, and the simulations for three different types of drones are conducted to localize the multiple drones based on the measured acoustic signals. The test result shows that the location of multiple drones can be estimated by utilizing the acoustic characteristics of the drone. Also, one can see that the clarity of the separated drone sound source and the source localization algorithm affect the accuracy of the localization for multiple-drone sound sources.

Effect of calf strengthening exercise on walking mechanism in middle-aged women (종아리 강화 운동이 중년여성의 보행메커니즘에 미치는 영향)

  • Jong-Geun Kim;Gyeong-Hee Cho
    • The Journal of the Convergence on Culture Technology
    • /
    • v.10 no.4
    • /
    • pp.235-240
    • /
    • 2024
  • We designed this study because it is necessary to take health care from middle age for to healthy old age. The purpose of this study was to confirm the effect of middle-aged women on the walking mechanism by applying an exercise program that can achieve the maximum effect through simple exercise regardless of time and place. A total of 20 subjects were selected from middle-aged women aged 45 years or older, with 10 calf-enhancing exercise groups and 10 control groups. As a result of comparing before and after exercise in the calf-enhancing exercise group, the step length left and right, and double support, step time, and speed were improved. As a result of comparing the walking mechanisms of the calf-enhancing exercise group and the non-exercise group after exercise, the step length left and right, and step time left and right were improved. The positive effect of the walking mechanism was shown through the calf-enhancing exercise regardless of time and place. In particular, it is judged that the stride was widened, resulting in an increase in the speed of walking due to the strength of the lower extremities and the shortening of the one-foot support section, resulting in meaningful results. In future studies, it is considered desirable to present measurement data for each life cycle by evaluating all ages, such as adolescents and the elderly, and to provide it as basic data for causing social problems due to lack of normal exercise.