• Title/Summary/Keyword: physical measurement

Search Result 2,887, Processing Time 0.029 seconds

Stress Index Processing Algorithm (스트레스 지수 처리 알고리즘에 관한 연구)

  • Han, Seung-Heon;Kim, Young-Kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.06a
    • /
    • pp.135-138
    • /
    • 2007
  • We may have had experience to use meaning of stress once at least. Because various mental and physical frustration, conflict, deprivation, and pressure have been happened around the us while we live our whole life. The stress is always existing at our surroundings as much. Now, most stress measurement method is composed of mental method and physical method. The accuracy of stress grade lacks to the disproportion of subjectivity, objectivity, and a science trait. Therefore, in this paper, we propose the index processing algorithm for a stress relief better, after mixing mental measurement result and physical measurement result.

  • PDF

Plan to build up a measurement system for rock physical properties monitoring during $CO_2$ injection ($CO_2$ 주입 암석물성 측정 장치 구축 방안)

  • Cho, Seong-Jun;Kim, Jung-Ho;Son, Jeong-Sul;Bang, Eun-Seok;Keehm, Young-Seuk;Synn, Joong-Ho
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.303-306
    • /
    • 2007
  • After Kyoto protocol took effect, many countries are making efforts to reduce $CO_2$ one of effective which is geosequestration. But a percentage of geosequestration in total research budget is very small and the priority order of research also is receded in Korea. As one of efforts to activate the research on geosequestration in field of geophysics, we proposed the plan to build up a measurement system for rock physical properties monitoring during $CO_2$ injection which will function as original technology. The system consists of two part, one of which is a data acquisition system based on seismic and complex resistivity tomographic measurement and the other of which is a tri-axial compressive system to realize the in-situ condition. And also developments of various inversion algorithms are proposed to interpret data qualitatively such as a inversion algorithm for confined cylindrical boundary, a joint inversion algorithm and a 4-D inversion algorithm.

  • PDF

Comparisons of Test-Retest Reliability of Strength Measurement of Gluteus Medius Strength between Break and Make Test in Subjects with Pelvic Drop

  • Jeon, In-Cheol
    • The Journal of Korean Physical Therapy
    • /
    • v.31 no.3
    • /
    • pp.147-150
    • /
    • 2019
  • Purpose: The purpose of this study was to compare the reliability of unilateral hip abductor strength assessment in side-lying with break and make test in subjects with pelvic drop. Hip abduction muscles are very important in the hip joint structures. Therefore, it is essential to evaluate their strength in a reliable way. Methods: Twenty-five subjects participated in this study. Unilateral isometric hip abductor muscle strength was measured in side-lying, with use of a specialized tensiometer using smart KEMA system for make test, of a hand held dynamometer for break test. Coefficients of variation, and intra class correlation coefficients were calculated to determine test-retest reliability of hip abductor strength. Results: In make test, maximal hip abductor strength in the side-lying position was significantly higher compared with break test (p<0.05). Additionally, Test-retest reliability of hip abductor strength measurements in terms of coefficients of variation (3.7% for make test, 16.1% for break test) was better in the side-lying position with make test. All intraclass correlation coefficients with break test were lower than make test (0.90 for make test, 0.73 for break test). Conclusion: The side-lying body position with make test offers more reliable assessment of unilateral hip abductor strength than the same position with break test. Make test in side-lying can be recommended for reliable measurement of hip abductor strength in subjects with pelvic drop.

Measurement of Internal Temperature Distribution for the Evaluation of Focused Ultrasound (FUS) Stimulation Devices (집속초음파 자극기의 성능평가를 위한 팬텀 내부온도 측정)

  • Doh, Il;Joe, Daniel J.;Kim, Sung Mok;Baik, Kyung Min;Kim, Yong Tae;Park, Seung Min
    • Journal of Biomedical Engineering Research
    • /
    • v.43 no.3
    • /
    • pp.147-152
    • /
    • 2022
  • This research is to measure real-time temperature distribution inside a tissue-mimicking phantom for the safety and effectiveness evaluations of focused ultrasound (FUS) device capable of linear scanning stimulation. Since the focusing area of the FUS stimulation device is smaller than diameter of conventional thermal probe and keeps moving, it is impossible to monitor temperature distribution inside the phantom. By using the phantom with a thin film temperature sensor array inserted, real-time temperature change caused by the FUS device was measured. The translation of the measured temperature peak was also tracked successfully. The present phantom had been experimentally proven to be applicable to validate the performance and safety of the therapeutic ultrasound devices.

A Study on the Physical Characteristics of Steel-Wire Sound Absorbing Materials (금속와이어 흡음재의 물리적 특성에 관한 연구)

  • 주경민;이동훈;용호택
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.1244-1249
    • /
    • 2002
  • In this study, the physical characteristics of steel-wire sound absorbing materials with different thickness and bulk density is experimentally obtained in terms of the porosity and specific flow resistivity. Based on the experimental results, the following conclusions can be made. The porosities of steel-wire sound absorbing materials are smaller than those of general absorbing materials, which are inversely proportional to the volume densities. For the porosity measurement with a good accuracy, the dynamic correction based on the system compliance should be involved in porosity measurement. In addition, the flow condition for the precise measurement of the specific flow resistivity of steel-wire sound absorbing materials should be limited in the laminar flow region.

  • PDF

Optical Performance Degradation Effects by Fabrication Errors of Circular-type Computer Generated Holograms

  • Kim, Young-Gwang;Rhee, Hyug-Gyo;Ghim, Young-Sik
    • Journal of the Korean Physical Society
    • /
    • v.73 no.11
    • /
    • pp.1657-1662
    • /
    • 2018
  • A null test method which relies on a computer generated hologram (CGH) is widely used to measure a large aspheric surface. For precise measurements of the surface shape of an aspheric optics, the CGH must precisely generate a wavefront that can fit on the ideal surface shape of the aspheric optics. If fabrication errors arise in the CGH, an unwanted wavefront will be generated and the measuring result will lack trustworthiness. Thus far, there has been limited research on wavefronts generated by CGH using only linear-type binary grating models. In this study, a theoretical error model of a circular-type zone plate, the most commonly used types for CGH patterns, is suggested. The proposed error model is checked by simulations and experiments.

A hybrid evaluation of information entropy meta-heuristic model and unascertained measurement theory for tennis motion tracking

  • Zhong, Yongfeng;Liang, Xiaojun
    • Advances in nano research
    • /
    • v.12 no.3
    • /
    • pp.263-279
    • /
    • 2022
  • In this research, the physical education training quality was investigated using the entropy model to compute variance associated with a random value (a strong tool). The entropy and undefined estimation principles are used to extract the greatest entropy of information dependent on the index system. In the study of tennis motion tracking from a dynamic viewpoint, such stages are utilized to improve the perception of the players' achievement (Lv et al. 2020). Six female tennis players served on the right side (50 cm from the T point). The initial flat serve from T point was the movement under consideration, and the entropy was utilized to weigh all indications. As a result, a multi-index measurement vector is stabilized, followed by the confidence level to determine the structural plane establishment range. As a result, the use of the unascertained measuring technique of information entropy showed an excellent approach to assessing athlete performance more accurately than traditional ways, enabling coaches and athletes to enhance their movements successfully.

Standard Field Generation Using a Micro-TEM Cell and Its Measurement Uncertainty Evaluation (Micro-TEM Cell을 사용한 표준 전자기장의 발생 및 측정불확도 평가)

  • Kang, Jin-Seob;Kim, Jeong-Hwan;Kang, Ung-Taek;Kang, No-Weon;Kang, Tae-Weon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.1
    • /
    • pp.91-99
    • /
    • 2009
  • In this paper, a standard field generation method using a micro-TEM ceil is described and its measurement uncertainty is evaluated. The standard field generation system consists of an auto-leveling signal source, a micro-TEM cell operating up to 1.2 GHz, and a power measuring Instrument using a thermistor mount. Measurement results of a field strength key comparison (CCEM.RF-K20) for the field strength of 20 V/m at frequencies between 10 MHz and 1 GHz are presented for validating the standard field generation method.

The Reliability and Relationships Between Thoracic Kyphosis, Postural Stiffness and Thoracic Rotation in Young Subjects (젊은 성인의 흉추후만지수 및 자세 경직도와 흉추회전각 간의 상관성과 신뢰도)

  • Jang, Hyun-Jeong;Kim, Suhn-Yeop;Kim, Myung-Jun
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.18 no.2
    • /
    • pp.49-55
    • /
    • 2012
  • Background: The purposes of this study were to: 1) investigate the relation between thoracic kyphosis, postural stiffness and thoracic rotation and 2) the intra-rater reliability of the measurement methods for thoracic kyphosis and rotation angle. Methods: Thirty-nine young adults (13 males, 26 females) participated in the study. Thoracic kyphosis was measured using a Flexicurve while standing in their usual relaxed posture and then in their maximally erector posture. Index of kyphosis (IK) measures taken in the relaxed and maximally erect positions were used to estimate postural stiffness. Thoracic rotation range of motion (ROM) was measured using universal goniometer and inclinometer in two positions. The association between the magnitude of the IK and thoracic stiffness and thoracic rotation ROM was also examined. Reliability was determined using intra-class correlation coefficients (ICC). Results: When measured from the mean relaxed IK (${\pm}SD$) was 7.42 (${\pm}1.47$) and mean erect IK was 4.92 (${\pm}1.63$) and mean IK ratio was 1.66 (${\pm}.65$). The relaxed IK was significantly correlated with the range of motion thoracic rotation in two positions (r=.503~580, p<.01). Conclusion: Thoracic kyphosis in relaxed position was associated with the range of motion thoracic rotation. Thoracic kyphosis measurement with the Flexicurve and range of motion 2 techniques of thoracic rotation showed good reliablity and may be a useful measurement tool in clinical practice.

  • PDF

The Reliability of the Pediatric Functional Muscle Testing in Children with Developmental Delay

  • Seo, Hye-Jung;Kim, Joong-Hwi
    • The Journal of Korean Physical Therapy
    • /
    • v.27 no.4
    • /
    • pp.183-189
    • /
    • 2015
  • Purpose: The aim of this study was to examine the test-retest and inter-rater reliability of the pediatric functional muscle testing (PFMT) when applied to children with developmental delay. Methods: Sixteen children with developmental delay (seven females, nine males) participated in this study. For the inter-rater reliability, each was scored on the PMFT by two pediatric physical therapists with more than 8 years of clinical experience on the same day. For assessment of the test-retest reliability, one therapist tested the children again within 10 days. The second measurement was performed by taking a first measurement in video. Intraclass correlation coefficient (ICC) was calculated to determine the test-retest and inter-rater reliability of the PFMT, and Chronbach's alpha was used to measure internal consistency. Results: The results of this study were as follows: 1) The test-retest ICC of the score of the infant action month and the right side of the PFMT was from 0.53 to 1.00 and from 0.63 to 0.99, respectively. 2) The inter-rater ICC of the score of the infant action month and the right side of the PFMT was from 0.66 to 1.00 and from 0.64 to 1.00, respectively. 3) Chronbach's alpha was 0.93. The internal consistency indicated excellent. Conclusion: In conclusion, this study showed that the test-retest and inter-rater reliability of the PFMT was relatively high, except for a few items. Therefore, it can be suggested that the PFMT will be a useful tool for measurement of muscle strength for children with developmental delay if it be some modifications.