• 제목/요약/키워드: physical measurement

검색결과 2,900건 처리시간 0.027초

A Display-based Visual Stimulator for Psychophysical and Electrophysiological Color Sensitivity Measurements

  • Hwang, Jisoo;Park, Seung-Nam;Park, Cheol-Min;Lee, Geun Woo;Kim, Kiseong
    • Journal of the Optical Society of Korea
    • /
    • 제16권2호
    • /
    • pp.145-150
    • /
    • 2012
  • We present a display-based visual stimulator for psychophysical and electrophysiological visual sensitivity measurements. The stimulator offers various psychophysical visual stimuli and transfers the signals from external devices along with the stimulation signals to an electrophysiological recorder. As an experimental demonstration, we perform a visual sensitivity experiment in the mesopic vision range by using the display-based stimulator. The intensity of the steady-state visual evoked potential is observed to correlate with the luminance of the flickering visual stimulation. For the psychophysically determined detection thresholds, we determine the mesopic luminance, showing agreement with the perceived brightness within the uncertainty of the luminance measurement.

Reliability of Navicular Drop Measurements in Standing and Sitting Positions

  • Park, Ji-Won;Chang, Jong-Sung;Nam, Ki-Seok
    • The Journal of Korean Physical Therapy
    • /
    • 제22권6호
    • /
    • pp.29-33
    • /
    • 2010
  • Purpose: This study was designed to investigate inter-rater and intra-rater reliability of navicular drop measurements by clinicians in sitting and standing positions. Methods: Fourteen subjects with pronated foot were recruited. Two physical therapists randomly assessed the same patients on different occasions but on the same day. Almost all patients were assessed on more than one day. The intra-rater and inter-rater reliability of navicular dropwas estimated by calculation of the intraclass correlation coefficient (ICC). Results: The intra-rater reliability of navicular drop measurements ranged from 0.93 to 0.87, the inter-rater reliability from 0.98 to 0.70 with the patient in standing and sitting positions. These results showed good reliability for calculated variables. Intra-rater and inter-rater reliability of navicular drop in standing position was higher than those of sitting position. Conclusion: Although inter-rater and intra-rater reliability of navicular drop in the sitting position was lower than in the standing position, measurement of navicular drop in the sitting position showed good reliability and was acceptable for patients who could not stand alone without assistance. We recommend that having the patient in the standing position is appropriate in navicular drop measurement.

편마비 환자의 운동조절 능력 향상을 위한 중재 프로그램의 효과 (The Effect of Intervention Program for Motor Control Ability in Hemiplegic Patients)

  • 신홍철;김웅각;강정일
    • The Journal of Korean Physical Therapy
    • /
    • 제17권3호
    • /
    • pp.377-390
    • /
    • 2005
  • The purpose of this study is to investigate the effect of neuromuscular re-education program and general intervention program. It is focused on difference between changes of experimental before and after on 20 stroke patient's motor control ability. The obtained results are as follows; In change in motor control ability, neuromuscular re-education program group about the motor control ability was a significant difference(p<.01). And traditional intervention program group, the motor control ability was a significant difference in all of items (p<.01; p<.05) but, were not a significant difference in bladder management, social interaction, problem solving and memory. And also comparison of change in motor control ability between the experimental group and control group, the between-subjects factors were a significant difference. Most of the functional items on the functional items on the functional measurement and neuromuscular function measurement are concerned with the physical autonomy of the hemiplegic patients. More in depth knowledge may be acquired about the distribution of physical and motor control patterns with respect to the degree of neurologic deficit for the enhencement of residual motor control function in hemiplegia. In conclusion, the neuromuscular re-education program was more effect then traditional intervention program in motor control ability.

  • PDF

남해 및 남동해역 대륙붕 퇴적물의 지음향 특성 (Geoacoustic Characteristics of Shelf Sediment in the South Sea and Southeastern Sea of Korea)

  • 김대철;서영교;정자헌;김길영
    • 한국수산과학회지
    • /
    • 제37권4호
    • /
    • pp.312-322
    • /
    • 2004
  • Physical and geoacoustic properties of inner shelf sediment in the South and Southeastern Seas of Korea have been studied based on six piston core samples. The sediments are largely composed of homogeneous mud except the core from the southeasternmost part of the area. Both physical and geoacoustic properties and mean grain size are relatively uniform with sediment depth, suggesting little effect of sediment compaction and/or consolidation. Mean grain size appears to be the most Important variable to determine the physical and acoustic properties. In contrast, the attenuation shows more or less fluctuations. Correlations between physical properties and sediment texture show slight deviations from those of the compared data, caused by the difference of sedimentary processes, mineral composition, and the difference of measurement system. In particular, the velocity is lower (approximately 20-30 m/s) than that of the previous data measured in the same area. This is probably due to the difference in velocity measurement system (particularly, error by a length of sample). We propose new relationships for physical and geoacoustic characteristics of shelf sediment in the study area.

엉덩관절 수술 환자에서 스마트폰을 이용한 관절가동범위 측정의 신뢰도 및 타당도 연구 (The Reliability and Validity of Hip Range of Motion Measurement using a Smart phone Operative Patient)

  • 박선욱;김명수;배효선;차용호
    • 대한물리의학회지
    • /
    • 제10권2호
    • /
    • pp.1-7
    • /
    • 2015
  • PURPOSE: The aims of this study were to assess the intra-tester and inter-tester reliability and validity of hip range of motion using a smart phone in hip operative patients. METHODS: Twenty-five patients (eight total hip arthroplasty and seventeen femur neck fracture) participated in this study. The range of motions in active and passive hip flexion, abduction and external rotation were measured with a goniometer and smart phone over two times by two observers. The intra-tester and inter-tester reliability were evaluated using the intraclass correlation coefficient (ICC2,1). The validity was measured by Pearson's correlation coefficient RESULTS: The intra-observer reliability was good in all measured items (ICC>0.78). The inter-observer reliability was high with ICC (>0.90). All correlation coefficients of smart phone and goniometer was greater than 0.85 and showed a significant positive correlation (p<0.01). CONCLUSION: The range of motion measurement with a smart phone showed acceptable reliability. Therefore, it could be convenient and have economical benefits to measure the range of motion of the hip joint using a smart phone.

무릎관절 멀리건 테이핑이 균형능력과 각근력에 미치는 효과와 측정의 반복에 의한 효과 비교 (Comparison of the Balancing Capacity and Strength of Taping for the Knee Joint and Repeated Measurements)

  • 박보현;최수홍;김성중;박수형;오강오
    • 대한정형도수물리치료학회지
    • /
    • 제24권2호
    • /
    • pp.9-15
    • /
    • 2018
  • Background: The purpose of this study was to compare the effects of mulligan taping on knee joints on balance ability and strength with repeated measurements. Methods: Seventeen patients were randomly assigned to the 8 taping group and the 9 repeat measurement group. To measure the balance ability, fall risk assessment equipment was used, and the measurement of the muscle strength was performed by using the equipment of the same company. Results: Balanced abilities and muscle strength were increased in groups with taping only after Mulligan taping. Conclusions: The application of mulligan taping did not have the effect of stimulating the inherent receptive sensation. However, active grouping of the knee joint taping only, and muscle strength and muscle strength were increased. It increases the stability and activity of the muscles that operate on the balance of the active knee joint and muscle strength, thereby enhancing exercise prevention and prevention performance and exercise performance.

디지털경사계를 사용한 체간재위치오류 검사의 신뢰도 분석 (Analysis of Intrarater and Interrater Reliability of Trunk Repositioning Error Test using a Portable Digital Inclinometer)

  • 장우남;이경보;염준우;황병용
    • The Journal of Korean Physical Therapy
    • /
    • 제25권4호
    • /
    • pp.210-216
    • /
    • 2013
  • Purpose: A cost effective tool for the clinical measurement of trunk reposition sense is clearly needed. This study was to analyze intrarater and interrater Reliability of trunk repositioning error (TRE) test which assesses trunk position sense using a portable digital inclinometer. Methods: Twenty four normal healthy subjects were recruited. TRE was measured using a portable digital inclinometer. A digital inclinometer (Acumar-ACU360; Lafayetter Instrument) with precision to $1^{\circ}$ was placed on skin over the spinous process from first to second thoracic vertebra (T1-T2) and secured with double-sided tape. TRE test during sitting forward and lateral flexion movement was assessed. When they reached a point approximately 50% of full trunk flexion range, the examiner instructed the subjects to stop and told them. This was the target position that they should try to reproduce exactly. Each subject performed six trials. Results: ICC (2,1) for intrarater reliability (with-day and between-day) of TRE test in sagittal and frontal plane of movement was 0.75 and 0.78 (excellent reliability). Interrater reliability was 0.66 in sagittal and 0.64, frontal plane (fair to good reliability). However, there were poor correlations between an average of TRE test in sagittal and frontal plane. Conclusion: TRE test using a portable digital inclinometer demonstrated good to excellent reliability. The device may be a cost effective clinical measurement for trunk reposition sense measurement.

제조기업의 물류원가정보시스템의 설계 (Design of Physical Distribution Cost Information Systems of Manufacturing Enterprises)

  • 김동석
    • 산업경영시스템학회지
    • /
    • 제18권33호
    • /
    • pp.161-171
    • /
    • 1995
  • When physical distribution cost can be correctly measured, its management can also be efficient. Thus the primary objective of the study is to develop systems for measuring correctly physical distribution cost. The systems have two aspects : the One is the consumption of the resourses(materials, labor service, the other services), the other is the creation of physical distribution services(transportation, storage, cargo, packing, distribution conversion, management). By measuring the cost through the systems, the commoditization of the physical distribution services is possible and measurement of the cost and revenue can also be reasonable ,which makes its management efficient.

  • PDF

한국형 물리치료근무환경 측정도구 개발 및 평가 (Development and Validation of the Korean Physical Therapy Work Environment Scale (K-PTWES))

  • 이화경
    • 대한통합의학회지
    • /
    • 제12권2호
    • /
    • pp.65-76
    • /
    • 2024
  • Purpose : This study aimed to develop and validate a reliable tool, the Korean physical therapists' work environment scale (K-PTWES), for assessing the work environment of Korean physical therapists. The study also sought to examine the validity and reliability of the instrument. Methods : This methodological study involved the development and testing of the measurement tool. The conceptual framework was established through a literature review and in-depth interviews with clinical physical therapists. A total of 40 meaningful statements emerged from this process, leading to the generation of 29 primary items. Following a content validity test, 29 items were selected for the preliminary tool. Data were collected from 220 physical therapists across various job roles and unit types, such as outpatient and inpatient physical therapy rooms in domestic hospitals, with more than one year of experience. The final analysis included data from all 220 physical therapists. Results : Varimax rotated principal component analysis was employed for validities, revealing four factors: organizational support, working system, sustainable development, and relationship with coworkers, explaining a total variance of 54.97 %. The Cronbach's α coefficient for the final tool was .939, indicating high reliability. Conclusion : In this study, we developed a measurement tool reflecting the characteristics of the Korean physical therapists' work environment scale (K-PTWES). Our findings highlight the tool demonstrated both validity and reliability. Utilizing this tool is expected to contribute to understanding the work environment of Korean physical therapists and fostering a healthy work environment. Based on our findings, we recommend, firstly, conducting research on the work environment and related factors of physical therapists working in diverse settings using the K-PTWES. Secondly, future studies should focus on validating the tool's criterion-related validity, as it was not addressed in this research.

3차원 스캔측정치와 직접치수간 차이의 성별 비교 -제5차 Size Korea 성인데이터를 대상으로- (A Comparative Analysis of the Difference between 3D Body Scan Measurements and Physical Measurements by Gender -5th Size Korea Adult Data-)

  • 한현숙;남윤자
    • 한국의류학회지
    • /
    • 제33권8호
    • /
    • pp.1190-1202
    • /
    • 2009
  • A 3D body scan measurement (SM) is used as an alternative to physical measurements (PM) as the information for designing industrial products. This study compared the mean difference (MD) between SM and PM by gender and analyzed the causes of the difference. The data used in this study were the scan measurements and physical measurements of adults aged twenty to seventy years old of the fifth Size Korea survey. The results of this study are as follows: 1. The comparison of MD between men and women for all subjects: The measurement of the significant differences between men and women were height, neck base girth, chest girth, under-bust girth, waist girth, armscye girth, back length, and foot length. The causes of difference are the difference of body shape. 2. The comparison of MD between men and women by BMI groups: Many measurements had significant differences between men and women at normal weight and overweight but underweight. Some measurements had significant differences only at a specific BMI group because the body shape difference between men and women is revealed clearly in the group. The comparison of MD between men and women by age groups: The measurements that show significant difference at more than four age groups were neck girth, chest girth, under-bust girth, waist girth, armscye girth, and foot length. The height and abdomen girth had a significant difference in the age range of 20's and 30's. There were measurements that increase MD with an increase in age; under-bust girth and lateral shoulder length for women and lateral shoulder length for men. This comparison of MD between men and women provide the correct guidelines for the use of SM.