• 제목/요약/키워드: physical camera parameters

검색결과 49건 처리시간 0.02초

Determination of Physical Camera Parameters from DLT Parameters

  • Jeong Soo;Lee Changno;Oh Jaehong
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2004년도 Proceedings of ISRS 2004
    • /
    • pp.233-236
    • /
    • 2004
  • In this study, we analyzed the accuracy of the conversion from DLT parameters to physical camera parameters and optimized the use of DLT model for non-metric cameras in photogrammetric tasks. Using the simulated data, we computed two sets of physical camera parameters from DLT parameters and Bundle adjustment for various cases. Comparing two results based on the RMSE values of check points, we optimized the arrangement of GCPs for DLT.

  • PDF

직접선형변환 매개변수로부터 물리적 사진기 매개변수의 산정 (Determination of Physical Camera Parameters from DLT Parameters)

  • 정수;이창노;오재홍
    • 대한공간정보학회지
    • /
    • 제13권2호
    • /
    • pp.39-43
    • /
    • 2005
  • 본 연구에서는 비측량용 시진기의 해석 모델로서 주로 사용되는 직접선형변환(Direct Linear Transformation) 모델의 매개변수로부터 물리적 사진기 매개변수를 산정하는 데 있어서의 정확도를 분석하였으며, 사진측량 작업에서 직접선형변화 모델의 사용을 최적화 하였다. 모의 관측 자료를 사용하여, 다양한 경우에 대하여 물리적 사진기 매개변수를 직접선형변환에 의한 방법과 번들 조정에 의한 방법으로 각각 계산하였으며, 두 결과에 대해 검사점들의 평균제곱근오차를 비교함으로써 직접선형변환을 적용함에 있어서 지상기준점의 배치를 최적화 하였다.

  • PDF

신경망을 이용한 카메라 보정에 관한 연구 (A Study m Camera Calibration Using Artificial Neural Network)

  • 정경필;우동민;박동철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 B
    • /
    • pp.1248-1250
    • /
    • 1996
  • The objective of camera calibration is to obtain the correlation between camera image coordinate and 3-D real world coordinate. Most calibration methods are based on the camera model which consists of physical parameters of the camera like position, orientation, focal length, etc and in this case camera calibration means the process of computing those parameters. In this research, we suggest a new approach which must be very efficient because the artificial neural network(ANN) model implicitly contains all the physical parameters, some of which are very difficult to be estimated by the existing calibration methods. Implicit camera calibration which means the process of calibrating a camera without explicitly computing its physical parameters can be used for both 3-D measurement and generation of image coordinates. As training each calibration points having different height, we can find the perspective projection point. The point can be used for reconstruction 3-D real world coordinate having arbitrary height and image coordinate of arbitrary 3-D real world coordinate. Experimental comparison of our method with well-known Tsai's 2 stage method is made to verify the effectiveness of the proposed method.

  • PDF

퍼지 모델을 이용한 카메라 보정에 관한 연구 (Camera Calibration Using the Fuzzy Model)

  • 박민기
    • 한국지능시스템학회논문지
    • /
    • 제11권5호
    • /
    • pp.413-418
    • /
    • 2001
  • 본 논문에서는 기존에 사용한 물리적 카메라 모델 대신 퍼지 모델을 사용한 새로운 카메라 보정 방식을 제안한다. 카메라 보정은 카메라의 영상 좌표계와 실제 환경이 가지는 좌표계와의 관계를 규정하는 것으로, 퍼지 모델을 이용하는 방법은 기존의 방법에서 이용했던 물리적 변수들을 설정할 수는 없지만 카메라 보정의 목적인 카메라 좌표계와 실제 환경 좌표계와의 관계를 별다른 제약없이 규정할 수 있으므로 매우 간단하고 효율적인 카메라 보정 방법이다. 실제 실험을 통해 얻은 실공간상의 하나의 보정면 좌표에 대해 퍼지 모델링 방법을 이용하여 3차원 실 공간 좌표 및 2차원 영상좌표 예측을 통해 제안한 방법의 유효성을 보인다.

  • PDF

새로운 선형의 외형적 카메라 보정 기법 (A New Linear Explicit Camera Calibration Method)

  • 도용태
    • 센서학회지
    • /
    • 제23권1호
    • /
    • pp.66-71
    • /
    • 2014
  • Vision is the most important sensing capability for both men and sensory smart machines, such as intelligent robots. Sensed real 3D world and its 2D camera image can be related mathematically by a process called camera calibration. In this paper, we present a novel linear solution of camera calibration. Unlike most existing linear calibration methods, the proposed technique of this paper can identify camera parameters explicitly. Through the step-by-step procedure of the proposed method, the real physical elements of the perspective projection transformation matrix between 3D points and the corresponding 2D image points can be identified. This explicit solution will be useful for many practical 3D sensing applications including robotics. We verified the proposed method by using various cameras of different conditions.

Multi-camera System Calibration with Built-in Relative Orientation Constraints (Part 1) Theoretical Principle

  • Lari, Zahra;Habib, Ayman;Mazaheri, Mehdi;Al-Durgham, Kaleel
    • 한국측량학회지
    • /
    • 제32권3호
    • /
    • pp.191-204
    • /
    • 2014
  • In recent years, multi-camera systems have been recognized as an affordable alternative for the collection of 3D spatial data from physical surfaces. The collected data can be applied for different mapping(e.g., mobile mapping and mapping inaccessible locations)or metrology applications (e.g., industrial, biomedical, and architectural). In order to fully exploit the potential accuracy of these systems and ensure successful manipulation of the involved cameras, a careful system calibration should be performed prior to the data collection procedure. The calibration of a multi-camera system is accomplished when the individual cameras are calibrated and the geometric relationships among the different system components are defined. In this paper, a new single-step approach is introduced for the calibration of a multi-camera system (i.e., individual camera calibration and estimation of the lever-arm and boresight angles among the system components). In this approach, one of the cameras is set as the reference camera and the system mounting parameters are defined relative to that reference camera. The proposed approach is easy to implement and computationally efficient. The major advantage of this method, when compared to available multi-camera system calibration approaches, is the flexibility of being applied for either directly or indirectly geo-referenced multi-camera systems. The feasibility of the proposed approach is verified through experimental results using real data collected by a newly-developed indirectly geo-referenced multi-camera system.

팔걸이가 편마비환자의 보행에 미치는 영향 (Effect of an Arm Sling on Gait with Hemiparesis)

  • 송근호;이현옥
    • The Journal of Korean Physical Therapy
    • /
    • 제18권4호
    • /
    • pp.27-40
    • /
    • 2006
  • Purpose: This study was to investigate the effect of an arm sling on gait with hemiparesis. Methods: Fifteen patients(8 male, 7 female) with hemiparesis participated in this study and walked self-selected speed over 10m walkway, randomly without arm sling, with Single strap hemisling and Rolyan humeral cuff sling. It were filmed by 5 video camera and used with 3-dimensional motion analyzer system. The following gait variables were analyzed: temporo-spatial parameters, kinematic parameters. Results: In the comparison of temporo-spatial parameters each trial, walking velocity and single support time on affected side was significantly increased and step length on affected side, step length asymmetry ratio, single support time asymmetry ratio was significantly decreased in the Single strap hemisling and Rolyan humeral cuff sling. In the comparison of kinematic parameters each trial, maximal angle of the hip flexion on affected side was significantly increased in the Single strap hemisling and Rolyan humeral cuff sling and maximal angle of the knee flexion on affected side was significantly increased in the Rolyan humeral cuff sling and maximal angle of the ankle dorsiflexion on affected side was significantly increased in the Single strap hemisling. Conclusion: An arm sling improved walking velocity and decreased asymmetry and increased maximal angle of hip, knee, ankle flexion on affected side with hemiparesis caused by stroke.

  • PDF

비젼 제어시스템에 사용된 카메라의 최적개수에 대한 실험적 연구 (An Experimental Study on the Optimal Number of Cameras used for Vision Control System)

  • 장완식;김경석;김기영;안힘찬
    • 한국공작기계학회논문집
    • /
    • 제13권2호
    • /
    • pp.94-103
    • /
    • 2004
  • The vision system model used for this study involves the six parameters that permits a kind of adaptability in that relationship between the camera space location of manipulable visual cues and the vector of robot joint coordinates is estimated in real time. Also this vision control method requires the number of cameras to transform 2-D camera plane from 3-D physical space, and be used irrespective of location of cameras, if visual cues are displayed in the same camera plane. Thus, this study is to investigate the optimal number of cameras used for the developed vision control system according to the change of the number of cameras. This study is processed in the two ways : a) effectiveness of vision system model b) optimal number of cameras. These results show the evidence of the adaptability of the developed vision control method using the optimal number of cameras.

The effect of a water exercise on gait characteristics in the elderly post stroke patients

  • Lim, Hee-Sung;Lee, Suk-Min
    • Physical Therapy Rehabilitation Science
    • /
    • 제1권1호
    • /
    • pp.17-21
    • /
    • 2012
  • Objective: To investigate the effect of long-term water exercise on gait parameters in the elderly post stroke patients. Design: One group pretest-posttest design. Methods: Twenty elderly post stroke patients (age: $56.5{\pm}10.1$ years, height: $168.6{\pm}5.8cm$, body mass: $69.3{\pm}6.9kg$, handicapped level: $2.5{\pm}0.8$) participated in this study. Participants took part in gait training of 1 hour per day, three days per week, for three months. Participants' gaits were analyzed to find the effect of 3 months water exercise by a 3-D motion analysis with 8 infrared camera and 1 force plate (sampling frequency: 100 and 1,000 Hz, respectively). A paired t-test was used to find the significance with significant level as 0.05. Results: Gait velocity, step length & step width significantly increased, and asymmetric index for gait parameters significantly decreased after the water exercise (p<0.05). Conclusions: The water exercise effectively affect on patients' gait ability and electromyography analysis will be needed further study.

  • PDF

Distance Measurement Using a Single Camera with a Rotating Mirror

  • Kim Hyongsuk;Lin Chun-Shin;Song Jaehong;Chae Heesung
    • International Journal of Control, Automation, and Systems
    • /
    • 제3권4호
    • /
    • pp.542-551
    • /
    • 2005
  • A new distance measurement method with the use of a single camera and a rotating mirror is presented. A camera in front of a rotating mirror acquires a sequence of reflected images, from which distance information is extracted. The distance measurement is based on the idea that the corresponding pixel of an object point at a longer distance moves at a higher speed in a sequence of images in this type of system setting. Distance measurement based on such pixel movement is investigated. Like many other image-based techniques, this presented technique requires matching corresponding points in two images. To alleviate such difficulty, two kinds of techniques of image tracking through the sequence of images and the utilization of multiple sets of image frames are described. Precision improvement is possible and is one attractive merit. The presented approach with a rotating mirror is especially suitable for such multiple measurements. The imprecision caused by the physical limit could be improved through making several measurements and taking an average. In this paper, mathematics necessary for implementing the technique is derived and presented. Also, the error sensitivities of related parameters are analyzed. Experimental results using the real camera-mirror setup are reported.