• 제목/요약/키워드: photovoltaic system

검색결과 1,979건 처리시간 0.023초

PV모듈의 음영 상태 및 바이패스 다이오드 단락 고장 특성 분석 (The Characteristics of PV module under the Partial Shading Condition and with a Failure of Bypass Diode with Short)

  • 고석환;주영철;소정훈;황혜미;정영석;강기환
    • 한국태양에너지학회 논문집
    • /
    • 제36권4호
    • /
    • pp.41-47
    • /
    • 2016
  • A bypass diode is connected in parallel to solar cells with opposite polarity. The advantage of using the bypass diode is circumvented a destructive efforts of hot-spot heating in the photovoltaic(PV) module. In addition, it is possible to reduce a energy loss under the partial shading on the PV module. This paper presents a characteristic of photovoltaic module under partial shading condition and with defective bypass diode by using the experimental data. The results of field testing for each photovoltaic modules, when photovoltaic system which is connected power grid is operating, the inner junction-box temperature of shading photovoltaic module is high $5^{\circ}C$ because of difference of flowing current through into bypass diode. And incase of not operating photovoltaic system, the inner junction-box temperature of module with defective bypass diode is greatly higher than partial shading PV module.

50kw급 PV시스템 시뮬레이터의 구현 및 경제성 분석에 관한 연구 (Implementation of the 50kW Utility Interconnected PV System Simulator and the Study of Financial Analysis)

  • 이강연;김용구;신석두;김형곤;전형석;김병철;민완기;김남오
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 정기총회 및 학술대회 전문대학교육위원
    • /
    • pp.157-159
    • /
    • 2008
  • This paper summarizes the results of these efforts by offering a photovoltaic system structure in 50kW. The combination of photovoltaic system components are interconnected and system monitoring system will be summarized for the purpose of the increasing safety in this article. This paper describes configuration of utility interactive photovoltaic system which generated electric power supplies to dormitory. In order to installing the middle or large scale photovoltaic system, It must investigated the optimal design of system, compute quantity of power generation, economic rate of return and so on. In this paper represent 50kW utility photovoltaic system examination, developed simulation results and financial analysis. The performance of photovoltaic system has been evaluated, analyzed with simulation and financial analysis results. The results obtained in this research will be much useful to prior investigation for installing utility interactive photovoltaic system.

  • PDF

수상태양광의 시공기술에 관한 실증연구 (The Technique of Installing Floating Photovoltaic Systems)

  • 최영관;이종석
    • 한국산학기술학회논문지
    • /
    • 제14권9호
    • /
    • pp.4447-4454
    • /
    • 2013
  • 2011년 10월 국내 최초로 다목적댐 저수지에 100kW급 수상태양광발전 상용화 실증 플랜트가 합천댐에 설치되었다. 수상태양광발전 설비는 육상에 설치하는 태양광발전 설비와는 달리 수상부유체, 계류장치, 수중케이블 등 설치에 많은 어려움이 있다. 특히 수상이라는 환경적 제약으로 인해 육상 태양광 시공 방법으로 공정 관리를 할 수 없는 많은 변수가 속출한다. 수상태양광발전의 구조체는 수상태양광 모듈 및 기타 전기설비를 수상에 부상시키기 위한 설비로서 바람이나 태풍 등 기상환경에 견뎌야 하고 수질에 악영향을 미치지 말아야하며 시공성, 경제성 등 종합적인 고려가 필요하다. 본 논문에서는 100kW 수상태양광 시공사례를 바탕으로 수상태양광의 구조체, 계류장치, 수중케이블, 전력설비 및 원격감시제어시스템의 시공기술에 대한 기초자료를 제공하였다. 본 연구에서 시공된 100kW 수상태양광은 현재 평균 설비이용률 15%로 운영중에 있다.

다습환경 태양광발전시스템 안전성 평가 (Safety Evaluation of Solar Power System in High Humidity Environment)

  • 윤용호
    • 한국인터넷방송통신학회논문지
    • /
    • 제19권2호
    • /
    • pp.181-186
    • /
    • 2019
  • 수상태양광발전 시스템은 건물옥상이나 산지 등에 개발되는 육상 태양광 발전과는 달리 주로 댐이나 저수지 등 수면위에 부력체를 이용하여 태양광 모듈을 설치하는 새로운 개념의 발전기술로서 국내 저수지 수면의 약 5 % 정도만 활용하다라도 약 4,170 MW 규모의 발전시설 건설이 가능할 만큼 개발 잠재량이 풍부하여 환경에 대한 훼손이 없이 국토의 효율적 이용이 가능한 장점이 있다. 그러나 육상과 달리 수면위에서 태양광 발전을 하기 위해서는 부력체를 이용하여 모듈 등 발전시설을 수면 위에 설치하여야 하며, 이와 더불어 수위 및 유속의 변동 등에도 안정적으로 시설을 유지할 수 있는 기술이 요구된다. 이러한 수상태양광발전 시스템에 추가적으로 안전성을 평가할 수 있는 기술기준이 현재 정립이 되어 있지 않으며 본 논문을 통해 수상태양광발전 시스템의 표준화를 위해 고려할 사항들을 정리하였다.

태양광/풍력 복합발전 시스템의 최대출력제어기 설계 (A hybrid maximum power tracker for a photovoltaic/wind hybrid power system)

  • 정상식;김시경;정영석;유권종;송진수
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 전력전자학술대회 논문집
    • /
    • pp.134-137
    • /
    • 1998
  • In this paper, a hybrid maximum power tracker for a photovoltaic/wind hybrid power system is proposed. In the hybrid system, a direct interfacing the wind power system to the photovoltaic system gives the problems of voltage fluctuations, poor maximum power tracking, and harmonics generation associated with the random wind speed, the random solar irradiation and the pulsating torque came from the wind turbine synchronous generator and photovoltaic. To overcome these problems, a wind side DC/DC converter are proposed employing a star/delta transformer interconnected between the wind turbine side and the photovoltaic side. The control objective for each dc/dc converter is to extract maximum power from each different photovoltaic system and wind system, and transfer two different powers to the inverter and load.

  • PDF

조선대학교 기숙사전원용 50kW 태양광발전시스템 발전특성 (Operating Characteristics of 50kW Utility Interactive Photovoltaic System)

  • 박정민;김지훈;최연옥;김대곤;장용해
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.720-722
    • /
    • 2005
  • A photovoltaic panel is a device that, through the photovoltaic effect, converts luminous energy into electric energy. Photovoltaic generation system uses infinity of solar energy, cost of fuel is needless and there is no all pollution or waste occurrence. This paper summarizes the results of these efforts by offering a photovoltaic system structure in 50kW large scale applications installed In Chosun University dormitory roof. The status of PV system components, are inter-connection and safety equipment monitoring system will be summarized as this article. This describes configuration of utility interactive photovoltaic system which generated power supply for dormitory In this paper represent 50kw utility PV system examination result

  • PDF

Development of Tracking Algorithm for Floating Photovoltaic System

  • So, Byung-Moon;Im, Ik-Tae
    • 반도체디스플레이기술학회지
    • /
    • 제18권1호
    • /
    • pp.53-58
    • /
    • 2019
  • Since floating facility with mooring system can be moved and rotated by wind or other environmental variables, the error in azimuthal angle must be compensated using a GPS receiver and geo-magnetic sensor. Accordingly, when an existing photovoltaic tracking algorithm is applied to a floating photovoltaic system, it is difficult to do the optimal solar tracking. In this paper, an effective azimuthal angle algorithm is develop for the photovoltaic tracking in floating condition. In order to verify the developed algorithm, the prototype of the floating photovoltaic system is manufactured and the developed algorithm is applied to the system. The algorithm shows a good tracking feasibility on the prototype.

Design loads for floating solar photovoltaic system: Guide to design using DNV and ASCE standards

  • Gihwan Kim;Moonsu Park
    • Structural Engineering and Mechanics
    • /
    • 제89권2호
    • /
    • pp.171-179
    • /
    • 2024
  • The market of the floating solar photovoltaic system is rapidly growing around the world with the rise of renewable energy that can replace fossil energy. While the floating solar photovoltaic system is operating and being installed in several countries, the system is exposed to the risk in terms of structural safety due to the absence of the proper design guideline. In this paper, design loads suitable for the floating solar photovoltaic system are presented. Utilizing the existing reliable design standards such as ASCE 7-16 (ASCE 7-16 2016) and DNV-RP-C205 (DNV-RP-C205 2010), the appropriate design loads for the floating solar photovoltaic system are presented. The proper load combinations are also presented by putting wave load based on DNV standards (DNV-OS-C101 2015 and DNV-OS-C201 2015) into the load combinations in ASCE standards (ASCE 7-16 2016). We present the load combinations for the allowable stress design and load and resistance factor design, respectively.

태양광발전시스템의 장기운전에 의한 성능변화 분석 (Performance Analysis of long term operation for photovoltaic system)

  • 김의환;김정삼
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 춘계학술대회 초록집
    • /
    • pp.110.1-110.1
    • /
    • 2011
  • This study analyzed the performance of long term operation photovoltaic system The 50 kWp grid connected photovoltaic system which was installed at KEPRI site in 1999 has been operated more than 12 years. In order to acquire long term operation characteristics of medium size photovoltaic system, the operation test data related on power generation electricity and capacity factor of 50 kWp system, which have been collected since 1999, were analysed. From the analysing results, 57.7 MWh in annual power generation electricity of 50 kWp photovoltaic system in 1999 has been decreased 49.1 MWh in 2005 and reached 38.0 MWh in 2010. In addition to, the capacity factor of 50 kWp photovoltaic system also showed 13.2 % in 1999, 11.2% in 2005 and finally reached 8.8% in 2011. The operation test data showed a trend of decreasing of generation electricity and capacity factor during the 12 years operation time and we guessed that was caused by solar cell performance degradation and decreasing of PCS system efficiency.

  • PDF

광역별 MW급 태양광발전시스템의 발전량 특성 비교분석 기초(I) (The Basic of Comparative Analysis on Characteristic of MW Photovoltaic Power System on Wide Area)

  • 박석기;김동균;최익;최주엽;유권종
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2016년도 전력전자학술대회 논문집
    • /
    • pp.475-476
    • /
    • 2016
  • According to government supporting a renewable generation, a number of industrial MW photovoltaic systems have already been installed and rapidly increased. Even though the supporting is increased, analysis on power valuation and roll of a photovoltaic system are insufficient. In this paper, comparative analysis on characteristic of photovoltaic power system are illustrated as basic of power valuation by collecting power and irradiation data from MW photovoltaic system on wide area.

  • PDF