Study of Localized Surface Plasmon Polariton Effect on Radiative Decay Rate of InGaN/GaN Pyramid Structures

  • Gong, Su-Hyun;Ko, Young-Ho;Kim, Je-Hyung;Jin, Li-Hua;Kim, Joo-Sung;Kim, Taek;Cho, Yong-Hoon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.184-184
    • /
    • 2012
  • Recently, InGaN/GaN multi-quantum well grown on GaN pyramid structures have attracted much attention due to their hybrid characteristics of quantum well, quantum wire, and quantum dot. This gives us broad band emission which will be useful for phosphor-free white light emitting diode. On the other hand, by using quantum dot emission on top of the pyramid, site selective single photon source could be realized. However, these structures still have several limitations for the single photon source. For instance, the quantum efficiency of quantum dot emission should be improved further. As detection systems have limited numerical aperture, collection efficiency is also important issue. It has been known that micro-cavities can be utilized to modify the radiative decay rate and to control the radiation pattern of quantum dot. Researchers have also been interested in nano-cavities using localized surface plasmon. Although the plasmonic cavities have small quality factor due to high loss of metal, it could have small mode volume because plasmonic wavelength is much smaller than the wavelength in the dielectric cavities. In this work, we used localized surface plasmon to improve efficiency of InGaN qunatum dot as a single photon emitter. We could easily get the localized surface plasmon mode after deposit the metal thin film because lnGaN/GaN multi quantum well has the pyramidal geometry. With numerical simulation (i.e., Finite Difference Time Domain method), we observed highly enhanced decay rate and modified radiation pattern. To confirm these localized surface plasmon effect experimentally, we deposited metal thin films on InGaN/GaN pyramid structures using e-beam deposition. Then, photoluminescence and time-resolved photoluminescence were carried out to measure the improvement of radiative decay rate (Purcell factor). By carrying out cathodoluminescence (CL) experiments, spatial-resolved CL images could also be obtained. As we mentioned before, collection efficiency is also important issue to make an efficient single photon emitter. To confirm the radiation pattern of quantum dot, Fourier optics system was used to capture the angular property of emission. We believe that highly focused localized surface plasmon around site-selective InGaN quantum dot could be a feasible single photon emitter.

  • PDF

A Case of Neuro-Behest's Disease: Comparison of Neurological Symptoms with PET, SPECT, and MRI Findings (신경 베체트병 1례: 신경학적 증상과 뇌 PET, SPECT, MRI 소견의 비교)

  • Kim, Jin-Wook;An, Min;Kim, So-Yon;Kim, Young-Jung;Cho, Min-Koo;Lee, Gwon-Jun;Lim, Sang-Moo;Hong, Sung-Woon;Choi, Chang-Woon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.6
    • /
    • pp.534-541
    • /
    • 1998
  • We describe a 27-year-old man who developed gait disturbance and dysarthria 2 years after the onset of cardinal symptoms of Behcet's disease. Positron emission tomography with $^{18}F$-fluorodeoxyglucose revealed severe hypometabolisrn in the cerebellum, in accordance with cerebellar symptoms and signs of the patient. However, single-photon emission tomography with $^{99m}Tc$-HMPAO and $^{99m}Tc$-ECD did not disclose significant perfusion abnormalities in the brain. Routine brain magnetic resonance imaging did not show signal abnormalities. The findings of imaging studies compared with neurological manifestations of the patient are discussed.

  • PDF

In Vivo Stem Cell Imaging Principles and Applications

  • Seongje Hong;Dong-Sung Lee;Geun-Woo Bae;Juhyeong Jeon;Hak Kyun Kim;Siyeon Rhee;Kyung Oh Jung
    • International Journal of Stem Cells
    • /
    • v.16 no.4
    • /
    • pp.363-375
    • /
    • 2023
  • Stem cells are the foundational cells for every organ and tissue in our body. Cell-based therapeutics using stem cells in regenerative medicine have received attracting attention as a possible treatment for various diseases caused by congenital defects. Stem cells such as induced pluripotent stem cells (iPSCs) as well as embryonic stem cells (ESCs), mesenchymal stem cells (MSCs), and neuroprogenitors stem cells (NSCs) have recently been studied in various ways as a cell-based therapeutic agent. When various stem cells are transplanted into a living body, they can differentiate and perform complex functions. For stem cell transplantation, it is essential to determine the suitability of the stem cell-based treatment by evaluating the origin of stem, the route of administration, in vivo bio-distribution, transplanted cell survival, function, and mobility. Currently, these various stem cells are being imaged in vivo through various molecular imaging methods. Various imaging modalities such as optical imaging, magnetic resonance imaging (MRI), ultrasound (US), positron emission tomography (PET), and single-photon emission computed tomography (SPECT) have been introduced for the application of various stem cell imaging. In this review, we discuss the principles and recent advances of in vivo molecular imaging for application of stem cell research.

A Novel Method for the Fabrication of Monodispersed Carbon Nanospheres and Their Crosslinked Forms

  • Im, Ji-Eun;Lee, Ha-Na;Li, Jing;Kim, Yong-Rok
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.3
    • /
    • pp.871-874
    • /
    • 2014
  • Monodispersed carbon nanospheres (CNSs) were fabricated by a novel method and their structural properties were investigated. CNSs were prepared by the pyrolysis of nanospherical polystyrenes (PS). With the coating of $SiO_2$ shell, PS particles were effectively separated during pyrolysis process which resulted to CNSs with an average diameter of 40 nm. Moreover, CNSs could be crosslinked with each other through the bondings between the functional groups on their surfaces. Morphology of the fabricated carbon spheres and their crosslinked form were characterized by X-ray diffraction (XRD), field-emission scanning electron microscopy (FESEM), transmission electron microscopy (TEM), and fourier transform infrared spectroscopy (FT-IR).

Concentration optimization of Tb/Yb co-doped alumino-germanosilicate optical fiber for upconversion visible laser applications

  • Lin, Aoxiang;Watekar, Pramod R.;Liu, Xueming;Cho, Hye-Jin;Chung, Young-Joo;Han, Won-Taek
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2008.02a
    • /
    • pp.249-250
    • /
    • 2008
  • We report on the visible photoluminescence of the Tb/Yb co-doped alumino-germano-silicate fibers for visible fiber laser application. By changing the concentration ratios of $Tb^{3+}$ to $Yb^{3+}$, we optimized the solution doping conditions and obtained the highest emission efficiency at 546nm. The luminescence intensity at 546nm was found to increase with the relative increase of $Tb^{3+}$ ions.

  • PDF

Quantum Jump Approach to Stimulated Absorption and Emission

  • Lee, Chang Jae
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.8
    • /
    • pp.1186-1188
    • /
    • 2006
  • In this paper a new theory is presented to treat the problem of stimulated absorption and emission of photons between energy levels from the standpoint of discrete quantum jumps. In order to implement the theory a scheme to avoid the quantum Zeno effect is proposed. Numerical simulations are performed to demonstrate that this approach does not contradict the principles of the standard wave mechanics. It is shown that with this approach one can obtain photon observation statistics as well.

Photon Extraction Efficiency in InGaN Light-emitting Diodes Depending on Chip Structures and Chip-mount Schemes (InGaN LED에서 칩 구조 및 칩마운트 구조에 따른 광추출효율에 관한 연구)

  • Lee, Song-Jae
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.3
    • /
    • pp.275-286
    • /
    • 2005
  • The performance of the InGaN LED's in terms of the photon extraction efficiency has been analyzed by the Monte Carlo photon simulation method. Simulation results show that the sidewall slanting scheme, which works well for the AlInGaP or InGaN/SiC LED, plays a very minimal role in InGaN/sapphire LED's. In contrast to InGaN/SiC LED's, the lower refractive index sapphire substrate restricts the generated photons to enter the substrate, minimizing the chances for the photons to be deflected by the slanted sidewalls of the epitaxial semiconductor layers that are usually very thin. The limited photon transmission to the sapphire substrate also degrades the. photon extraction efficiency especially in the epitaxial-side down mount. One approach to exploit the photon extraction potential of the epitaxial-side down mount may be to texture the substrate-epitaxy interface. In this case, randomized photon deflection off the textured interface directly increases the number of the photons entering the sapphire substrate, from which they easily couple out of the chip and thereby improving the photon extraction efficiency drastically.

Radioligands for Imaging Dopamine and Serotonin Receptors and Transporters (도파민과 세로토닌 운반체 및 수용체 영상을 위한 방사성리간드)

  • Chi, Dae-Yoon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.3
    • /
    • pp.159-168
    • /
    • 2000
  • In the 1980s, techniques to image the human subjects in a three-dimensional direction were developed. Two major techniques are SPECT (Single Photon Emission Computed Tomography) and PET (Positron Emission Tomography) which allow the detector to detect a single photon or annihilation photons emitted from the subjects injected with radiopharmaceuticals. Since the latter two techniques can measure the density of receptors, enzymes and transporters in living human, it may be very important project to develop selective methods of labeling with radionuclides and to develop new radiopharmaceuticals. There has been a considerable interest in developing new compounds which specifically bind to dopamine and serotonin receptor and transporters, and it will be thus very useful to label those compounds with radionuclides in order to gain a better understanding in biochemical and pharmacological interactions in living human. This review mentions the characteristics of radioligands for the imaging of dopamine and serotonin receptors and transporters. Although significant progress has been achieved in the development of new PET and SPECT ligands for in vivo imaging of those receptors and transporters, there are continuous needs of new diagnostic radioligands.

  • PDF

A finite Element Analysis on the discharge characteristics of $SF_6$ gas ($SF_6$ 가스 방전 특성의 유한요소해석)

  • 최승길;심재학;강형부
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.3
    • /
    • pp.265-272
    • /
    • 2000
  • In this paper the corona discharge in SF$_{6}$ gas used as insulating material in lots o high voltage equipment, is simulated by finite element method with Flux-Corrected Transport(FCT) method. By application of proposed method the negative corona discharge characteristics in needle to plane electrode is analyzed with time step. For the accuracy of analysis the secondary electron emission by photon and ion are also considered as well as the accuracy of analysis the secondary electron emission by photon and ion are also considered as well as townsend first ionization and electron attachment. The calculated results show that the electric field intensity between anode and ion group is decreased as times go-by according to field distortion by those space charge. Accordingly the electron density is decreased strongly by the attatchment effect of SF6 gas so that the corona discharge becomes extinguished abruptly.y.

  • PDF