• Title/Summary/Keyword: photoelastic study

Search Result 119, Processing Time 0.025 seconds

Hybrid Full-field Stress Analysis around a Circular Hole in a Tensile Loaded Plate using Conformal Mapping and Photoelastic Experiment (등각사상 맵핑 및 광탄성 실험법에 의한 원형구명 주위의 하이브리드 응력장 해석)

  • Baek, Tae-Hyun;Kim, Myung-Soo;Rhee, Ju-Hun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.23 no.6 s.165
    • /
    • pp.988-1000
    • /
    • 1999
  • An experimental study is presented for the effect of number of terms of a pewee series type stress function on stress analysis around a hole in tensile loaded plate. The hybrid method coupling photoelastsic data inputs and complex variable formulations involving conformal mappings and analytical continuity is used to calculate tangential stress on the boundary of the hole in uniaxially loaded, finite width tensile plate. In order to measure isochromatic data accurately, actual photoelastic fringe patterns are two times multiplied and sharpened by digital image processing. For qualitative comparison, actual fringes are compared with calculated ones. For quantitative comparison, percentage errors and standard deviations with respect to percentage errors are caculated for all measured points by changing the number of terms of stress function. The experimental results indicate that stress concentration factors analyzed by the hybrid method are accurate within three percent compared with ones obtained by theoretical and finite element analysis.

PHOTOELASTIC STRESS ANALYSIS ON THE SUPPORTING TISSUE OF MANDIBULAR DISTAL EXTENSION REMOVABLE PARTIAL DENTURE WITH VARIOUS DESIGN OF DIRECT RETAINERS (직접유지장치 설계 변화에 따른 하악 후방연장 국소의치 지지조직의 광탄성 응력분석)

  • Lee Chang-Ho;Kim Kwang-Nam;Chang Ik-Tae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.30 no.2
    • /
    • pp.203-224
    • /
    • 1992
  • The purpose of this study was to evaluate the stress distribution developed in supporting structures by distal extension removable partial denture with 4-types of direct retainer. The direct retainers examined were Akers clasp, RPI clasp, RPA clasp and RPL clasp in bilateral & unilateral free end case. 3-dimensional photoelastic stress analysis was used to record the isochromatic fringe patterns and to calculate the compressive stress at measuring points. The results were as follows. 1. In bilateral free end case, RPI clasp exhibited the similar stress distribution on distal and mesial alveolar crest but Akers clasp exhibited higher stress concentration on distal alveolar crest than mesial alveolar crest. 2. In bilateral free end case, RPA clasp and RPL clasp exhibited the similar stress distribution on distal and mesial alveolar crest and RPL clasp exhibited higher stress concentration on buccal alveolar crest than lingual alveolar crest. 3. Akers clasp produced high stress concentration on residual alveolar ridge distally, but RPI clasp, RPA clasp and RPL clasp produced even stress distribution on residual alveolar ridge. 4. Removable partial denture in unilateral free end case exerted higher stress on abutment tooth root apex than bilateral distal extension removable partial denture.

  • PDF

Photoelastic Stress Analysis of the Abutment Surrounding Tissue According to Shape of the Proximal Plate of the RPI Clasp (압축하중시 RPI clasp의 3가지 다른 proximal plate 형태에 따른 지대치 주위조직의 광탄성 응력 분석)

  • Choi, Jung Soo;Kim, Busob
    • Journal of Technologic Dentistry
    • /
    • v.34 no.4
    • /
    • pp.473-482
    • /
    • 2012
  • Purpose: The purpose of this study was to investigate the stress distribution of the surrounding tissues according to 3 proximal plate types of the RPI clasp. Methods: The removeable partial denture which mandibular right and left second premolars and mandibular molars were lost was attached to a three dimensional photo elastic epoxy resin model. Then 120N of vertical load was applied. After 3-dimensional photoelastic stress analysis was used to record the isochromatic fringe patterns. Results: Kratochvil type guiding plane exhibited little uniform stress distribution on load center and alveolar ridge, but higher stress concentration on buccal surface of second premolar. Krol type guiding plane exhibited the stress concentration on the front of load center and relatively higher stress concentration on buccal surface of first premolar. However, this type had no effect on canine. Researcher type guiding plane showed the stress concentration on second premolar and molar, but the little stress distribution on first premolar. Conclusion: In all types, excessive stress concentration was appeared and three types were not significant different.

A Stress Analysis of the Rotary Blade by Freezing Photoelastic Method (동결(凍結) 광탄성법(光彈性法)에 의한 로터리 경운날의 응력해석(應力解析))

  • Choi, S.I.;Kim, J.H.
    • Journal of Biosystems Engineering
    • /
    • v.16 no.3
    • /
    • pp.211-218
    • /
    • 1991
  • In this study, the break of the rotary blade which is occured from a stress concentration of the inside of blade by the outside impulsive load, is analyzed to 3-dimension used by the Freezing Photoelastic Method. These results are as follows. 1. The bending and compression stress are the greatest at the location of blade case. 2. The section area of 3cm-location from the blade case is the smallest, therefore, there are breaked 58% of all at this location and are proofed to the most danger section 3. The section area which by stress concentration of 3cm-location from blade case is caused by the production of blade, and it was higher danger of break than another location's. 4. In the location of 6cm and 9cm from the blade case, the bending stress has received a little and the section area has larger than another's, so it is not almost possible that the break at that location 5. In order to prevent of break, the external part which has contacted soil have to made tender for receiving a little stress and the internal part which received a large stress have to strengthen.

  • PDF

A Photoelastic Stress Analysis of Bilateral Distal Extension Removable Partial Denture with Attachment Retainers (정밀 부착형 유지장치에 따른 양측성 유리단 국소의치의 광탄성 응력분석)

  • Cho, Hye-Won;Chang, Ik-Tae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.23 no.1
    • /
    • pp.97-112
    • /
    • 1985
  • The purpose of this study was to evaluate the stress patterns developed in supporting structures by removable partial denture with attachment retainers. The attachments tested were Dalbo(miniature) attachment, resilient Ceka attachment, rigid Ceka attachment, precision and sleeve attachment, and R.P.I. clasp as a contrast. 3-dimensional photoelastic stress analysis was used to record the isochromatic and isoclinic fringe patterns and to calculate principal stress components at measuring points. The results showed that: 1. The maximum compressive stress on residual ridge was produced under the loading point with Dalbo and resilient Ceka attachment, distal to the loading point with rigid Ceka and precision and sleeve attachment, and mesial to the loading point with R.P.I. clasp. 2. The Dalbo attachment produced the most stress on residual ridge, and the least stress on abutment teeth. and resilient Ceka attachment showed favorable stress distribution. 3. Rigid Ceka attachment produced higher compressive stress on buccal. alveolar crest, and precision and sleeve attachment produced higher compressive stress on distal alvelolar crest and mesial surface of the root apex in abutment teeth. 4. R.P.I. clasp produced higher compressive stress on mesial alveolar crest.

  • PDF

A STUDY OF THE STRESS TRANSMISSION OF VARIOUS ARTIFICIAL TEETH AND DENTURE BASE MATERIALS TO THE UNDER-LYING SUPPORTING TISSUES (인공치와 의치상의 재질에 따른 의치상 하부 지지조직에의 응력전달에 관한 연구)

  • Chung, Hyun-Gun;Chung, Moon-Kyu;Lee, Ho-Yong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.27 no.2
    • /
    • pp.79-100
    • /
    • 1989
  • The Purpose of this study was to investigate material differences in stress transmission among various artificial teeth and denture base materials. For this study, a two-dimensional finite element model and a two-dimensional photoelastic model of a mandible with complete denture were made. A resin tooth and a porcelain tooth were used as artificial teeth, and a resin base, a metal lined base, and a soft-liner lined base were used as denture bases. An occlusal load was applied and principal stresses generated in the supporting tissues were compared. To test the impact stress transmission, strain gauge attached to the denture base specimens made of the different materials were made in thick and thin groups. Voltage outputs from hitting the specimen with a steel ball were compared. The results were as follows : 1. In FEM, increasing the mucosal thickness reduced the maximum principal stresses in the supporting tissues, but altering the tooth materials and the base materials induced no difference in the stresses. 2. In photoelastic model study, no difference in fringe order among the specimens were observed, but the thick mucosa group and the soft-liner lined group revealed a more uniform distribution of the load. 3. In strain measuring, the impact force transmission was highest in the soft-liner lined group, and was the lowest in the metal lined group(p<0.01). 4. In the thin group using the resin base, the porcelain tooth showed higher impact stress transmission than the resin tooth(p<0.01), but no difference was observed between them in the thick group. In the soft-liner lined group, the porcelain tooth showed higher impact stress transmission than the resin tooth(p<0.01), but no difference was observed between them in the metal lined group. 5. The thick group showed lower impact stress transmission than the thin group(p<0.01).

  • PDF

A Study on the Prediction and Reduction of Residual Stress in Glass (I): Analysis of Residual Stress in Glass by Instant Freezing Model (유리의 잔류응력 예측 및 감소화 방안 연구(I): 순간동결모델에 의한 유리의 잔류응력 해석)

  • 이재춘;백태현
    • Journal of the Korean Ceramic Society
    • /
    • v.31 no.8
    • /
    • pp.902-910
    • /
    • 1994
  • Residual stress measurements were made for cylindrical glass rods to compare experimental results with the calculated values obtained by Instant Freezing Model. According to the photoelastic measurements, the stress ratio of surface compression and center tension was increased from 1.4 to 2.0 as the heat-treatment temperature was lowered, the fictitious forzen temperature was found to be closer to the heat-treatment temperature and the fictitious coefficient was increased.

  • PDF

A study on the stress analysis for rake face of a tool with crack in cutting process (적삭중인 공구의 경사면상에 crack을 갖는 경우의 응력해석에 관한 연구)

  • 김원익;남준우
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.9 no.3
    • /
    • pp.66-75
    • /
    • 1987
  • The determination of stress distributions on the rake face of tool are important to understand the mechanism of metal cutting. For this reason, many researchers have been payed much effort to analyize machining stress distribution on the rake face. The author's photoelastic experiment has shown that the stress distributions on a rake face can be obtained photoelastically by using a specially designed tool made of epoxy resin plate, and also, Stress Intensity Factors $k_{I}$, $k_{II}$ and Crack Extension Angle can be deter mined by using Linear Elastic Fracture Mechanics.ics..

  • PDF

A PHOTOELASTIC STUDY OF THE STRESS DISTRIBUTION IN THE SURROUNDING TISSUES OF THE FIXED PARTIAL DENTURE WITH INTERMEDIATE ABUTMENT (중간지대치가 포함된 고정가공의치의 지대치 주위조직에서 발생하는 응력에 관한 광탄성학적 연구)

  • Jo, Kwang-Hyun;Choi, Boo-Byung;Park, Nam-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.25 no.1
    • /
    • pp.55-69
    • /
    • 1987
  • The purpose of this study was to evaluate the stress distributions of the fixed partial denture with five unit intermediate abutment. This fixed partial denture was attached to a three dimensional photoelastic epoxy resin model. Three dimensional photoelastic models were used, with the stress areas recorded photographically. A vertical load was applied to the second molar, which is the most posterior abutment of the fixed partial denture. Similarly, a vertical load was applied to the first molar because this tooth receives the heaviest masticatory load. These loads were added to two types of fixed partial denture. the rigid connector, and the nonrigid connector which was connected on the distal side of the intermediate abutment by a key and keyway device. After the stress patterns in surrounding tissues were observed, the following conclusions were as follows: 1. When the vertical load was applied to the first and second molars on the occlusal surfaces, the surrounding tissues of the roots of the canine, the second premolar, and the second molar were all compressive stresses. 2. When the vertical load was applied on the occlusal surface of the second molar, the tissue surrounding the roots of the canine, the second premolar, and the second molar all showed more stresses with the nonrigid connector than with the rigid connector. 3. When the vertical load was applied to the occlusal surface of the first molar, the stress concentration on the canine and the second molar was similar, whether the rigid or nonrigic connectors were used. However, on the second premolar, the stress concentration shown by the nonrigid connector was noticeably more than that shown by the rigid connector. 4. Whether the rigid or nonrigid connectors were used, when the load was placed on the first molar, the stress concentration on the canine and the second premolar was greater than that observed for the second molar. When the load was placed on the second molar, the load affected the second molar more than the canine and the second premolar.

  • PDF

A PHOTOELASTIC ANALYSIS OF STRESS DISTRIBUTIONS AROUND FIVE DIFFERENT TYPES OF ENDOSSEOUS IMPLANTS ACCORDING TO THEIR STRUCTURES (5종 골내 임플란트의 구조에 따른 주위의 응력분산에 관한 광탄성학적 연구)

  • Lee Jeong-Nam;Cho Sung-Am
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.4
    • /
    • pp.643-659
    • /
    • 1993
  • This study was performed for the purpose of evaluating the stress distributions around five different types of implants according to their structures. The stress distribution around the surrounding bone was analysed by two-dimensional photoelastic method. Five epoxy resin models were made, and vertical and lateral forces were applied to the models. A circular polariscope was used to record the isochromatic fringes. The results of this study were summerized as follows : 1. Threaded type implants showed more even stress distribution patterns than cylinderical type implants when vertical and lateral forces were applied. 2. The stress concentrated patterns were observed at the neck portion and middle portion of the cylindrical type implants comparing with threaded type implants when vertical force was applied. 3. Model 1 and model 4 which are tthreaded type implants showed similar stress distribution patterns at the middle and apical portions and more stress was concentrated at the neck porion of model 1 comparing with model 4 when vertical force was applied. The stresses around model 1 were more evenly distributed when lateral force was applied. 4. More stress was concentrated at the neck and middle portion of cylindrical type implants than threaded type implants when lateral force was applied. 5. Model 1 showed the most even stress distribution patterns when lateral force was applied and stress distribution did no occured at the apical portion of modedl 2 when lateral force was applied. 6. There were almost no differences in stress concentrated patterns with or without having hollow design. And the stress concentrated patterns were observed at the corner of apex in model 5 which has hollow design when vertical force was applied.

  • PDF