• Title/Summary/Keyword: photo-detection

Search Result 223, Processing Time 0.023 seconds

Photoreactivity of Anthraquinones for the Analysis of Ginsenosides Using Photoreduction Fluorescence Detection-HPLC

  • Park, Man-Ki;Kim, Bak-Kwang;Park, Jeong-Hill;Shin, Young-Geun;Cho, Kyung-Hee;Do, Young-Mi
    • Archives of Pharmacal Research
    • /
    • v.19 no.6
    • /
    • pp.562-565
    • /
    • 1996
  • The photoreactivity of twelve anthraquinone derivatives was examined to evaluate its usefulness as a photo-reagent for the analysis of ginsenosides using photoreduction fluorescence (PRF) detection method. Among the tested compounds, 2-tert-butylandthraquinone (TBAQ), 2-chloroanthraquinone (CAQ) and anthraquinone (AQ) showed good characteristics as photoreagents. The detection limits of ginsenoside $Rg_{1}$PRF-HPLC method using TBAQ, CAQ or AQ as a photo-reagent were found to be ca. 35 ng, 50 ng and 50 ng, respectively.

  • PDF

Process Monitoring in Laser Beam Cutting by Photo Diode (레이저 절단에서 광소자를 이용한 가공공정 모니터링)

  • 김봉채;장욱진;김재도
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1994.10a
    • /
    • pp.354-359
    • /
    • 1994
  • On-line process control equipment for CO $_{2}$ laser cutting is unavailable for industrial application. The major part of the industrial cutting machines are regulated off-line by highly educated engineers. The quality inspection of the sample is visual and referred to different quality scales. Due to lack of automation potential laser users hesitate to implement the cutting method. The first step toward an automation of the process is development of a process monitoring system and the research is concentrated on the area of on-line quality detection during CO $_{2}$ laser cutting. The method bases on the detection of the emitted light from the cut front by photo diode. the signal from photo diode has been undertaken from Fourier analysis and statistical analysis. As a result, it is possible to estimate striation pattern according to beam travel speed.

  • PDF

Photo-Acoustic Signal Detection of Water using FIR Light Source (원적외선 광원을 이용한 Water에서의 Photo Acoustic Signal의 검출)

  • 김건식;김태우;전계진;윤길원;최중길;박승한
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2002.07a
    • /
    • pp.252-253
    • /
    • 2002
  • 원적외선 영역에서 혈중성분들의 분광 특성이 존재함이 확인되면서 이 영역의 빛을 이용한 혈중 성분의 정량 분석을 통한 진단기술 개발이 활발히 진행되고 있다1). 특히 원적외선 영역에서 특정 파장에서의 반응성을 이용한 여러 방법들 중 photo-Acoustic을 이용한 방법이 여러 가지로 연구되어지고 있다. (2) 현재 수용액 상태의 혈중 성분들의 원적외선 분광 특성을 연구하였으며, 이를 이용한 혼합 성분들의 흡수 spectrum 정량-정성 분석이 가능하며, 이러한 특성을 이용하여 non-invasive로 이용 가능한 분광법을 연구 진행 중이다. (중략)

  • PDF

Development and Characterization of Finger-type PIN Photodiode for Fluorescence Detection of RNA (RNA 형광 검출을 위한 Finger형 PIN 광다이오드의 제작 및 평가)

  • Kim, Ju-Hwan;Oh, Myung-Hwan;Ju, Byeong-Kwon
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.2
    • /
    • pp.85-89
    • /
    • 2004
  • This paper represents the development of high sensitivity photo-sensor for the fluorescence detection in the integrated biological analysis system. The finger-type PIN photodiodes were fabricated as the photo-sensor, and had a high sensitivity ($I_{light}/I_{dark}$ = 8720). The interference filter consisted of $TiO_{2}$ and $SiO_{2}$ was directly deposited on the photodiodes. Deposited filter with 95.5% reflection under 532 nm and 98% transmission over 580 nm exceedingly decreased the magnitude of background signal in the detection. The PDMS micro-fluidic channels are bonded on the photodiode by $O_{2}$ plasma treatment. The detection current was proportional to two primary parameters (light intensity, concentration), and the on-chip detection system could detect fluorescence signals down to 100 nM concentration (LOD = Limit of detection of rhodamine).

Easy Detection of Amyloid β-Protein Using Photo-Sensitive Field Effect

  • Kim, Kwan-Soo;Ju, Jong-Il;Song, Ki-Bong
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.5
    • /
    • pp.339-344
    • /
    • 2012
  • This article describes a novel method for the detection of amyloid-${\beta}$($A{\beta}$) peptide that utilizes a photo-sensitive field-effect transistor (p-FET). According to a recent study, $A{\beta}$ protein has been known to play a central role in the pathogenesis of Alzheimer's disease (AD). Accordingly, we investigated the variation of photo current generated from p-FET with and without intracellular magnetic beads conjugated with $A{\beta}$ peptides, which are placed on the p-FET sensing areas. The decrease of photo current was observed due to the presence of the magnetic beads on the channel region. Moreover, a similar characteristic was shown when the Raw 264 cells take in magnetic beads treated with $A{\beta}$ peptide. This means that it is possible to simply detect a certain protein using magnetic beads and a p-FET device. Therefore, in this paper, we suggest that our method could detect tiny amounts of $A{\beta}$ for early diagnosis of AD using the p-FET devices.

Resolution improvement of a CMOS vision chip for edge detection by separating photo-sensing and edge detection circuits (수광 회로와 윤곽 검출 회로의 분리를 통한 윤곽 검출용 시각칩의 해상도 향상)

  • Kong, Jae-Sung;Suh, Sung-Ho;Kim, Sang-Heon;Shin, Jang-Kyoo;Lee, Min-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.112-119
    • /
    • 2006
  • Resolution of an image sensor is very significant parameter to improve. It is hard to improve the resolution of the CMOS vision chip for edge detection based on a biological retina using a resistive network because the vision chip contains additional circuits such as a resistive network and some processing circuits comparing with general image sensors such as CMOS image sensor (CIS). In this paper, we proved the problem of low resolution by separating photo-sensing and signal processing circuits. This type of vision chips occurs a problem of low operation speed because the signal processing circuits should be commonly used in a row of the photo-sensors. The low speed problem of operation was proved by using a reset decoder. A vision chip for edge detection with $128{\times}128$ pixel array has been designed and fabricated by using $0.35{\mu}m$ 2-poly 4-metal CMOS technology. The fabricated chip was integrated with optical lens as a camera system and investigated with real image. By using this chip, we could achieved sufficient edge images for real application.

Development and Application of Non-Contact Rock Fall Detection System utilizing Photo Sensor and Camera (광센서와 카메라를 활용한 비접촉식 낙석감지 시스템 개발 및 적용)

  • Jung, Yong-Bok;Song, Won-Kyong;Kim, Bok-Chul;Kim, Myung-Jin
    • Tunnel and Underground Space
    • /
    • v.20 no.3
    • /
    • pp.207-216
    • /
    • 2010
  • Rockfall monitoring systems generally used in the country are mainly based on the detection of tension of protection wire or tilting of protection post due to rock fall. However, rock fall protection net must be installed prior to the monitoring system and continual maintenance work after each rock fall event is required for a normal operation of these detection systems. To solve these problems, we suggested and implemented a non-contact rock fall detection system using multiple photo sensors and additional camera. After a laboratory experiment and field application, we can conclude that this system is effective and reliable for detecting, collecting and analyzing the rock fall information. In addition, lighten and difference operations on two captured images were able to yield rough estimation of size and direction of rock fall.

Development of Photo-diode for LOC fluorescence detector (LOC 형광검출 소자를 위한 광 다이오드의 제작 및 특성 평가)

  • Kim, Ju-Hwan;Shin, Kyeong-Sik;Kim, Yong-Kook;Kim, Sang-Sik;Ju, Byeong-Kwon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.04a
    • /
    • pp.100-103
    • /
    • 2003
  • Signal detection technologies such as fluorescence, charge and electrochemical detection used in the monolithic capillary electrophoresis system to convert the biochemical reaction into the electrical signal. The fluorescence detection using photodiodes that measure fluorescence emitted from eluting molecules is widely used for the monolithic capillary electrophoresis system. In this paper, in order to fabricate a photosensor has the increased sensitivity, we investigated on the sensitivity of general type and p-i-n type diode. The p-i-n diode has higher sensitivity than photodiode. Considering these results, we fabricated p-i-n diodes on the high resistive$(4k{\Omega}{\cdot}cm)$ wafer into rectangle and finger pattern and compared internal resistance of each pattern. The internal resistance of p-i-n diode can be decreased by the application of finger pattern has parallel resistance structure from $571{\Omega}$ to $393{\Omega}$.

  • PDF

Fabrication and characteristic evaluation of microfluidics chip integrated OLED for the light sources (OLED광원이 집적화된 마이크로 플루이딕칩의 제작 및 특성 평가)

  • Kim, Young-Hwan;Han, Jin-Woo;Kim, Jong-Yeon;Kim, Byoung-Yong;Seo, Dae-Shik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.377-377
    • /
    • 2007
  • A simplified integration process including packaging is presented, which enables the realization of the portable fluorescence detection system. A fluorescence detection microchip system consisting of an integrated PIN photodiode, an organic light emitting diode (OLED) as the light source, an interference filter, and a microchannel was developed. The on-chip fluorescence detector fabricated by poly(dimethylsiloxane) (PDMS)-based packaging had thin-film structure. A silicon-based integrated PIN photo diode combined with an optical filter removed the background noise, which was produced by an excitation source, on the same substrate. The active area of the finger-type PIN photo diode was extended to obtain a higher detection sensitivity of fluorescence. The sensitivity and the limit of detection (LOD S/N = 3) of the system were $0.198\;nA/{\mu}M$ and $10\;{\mu}M$, respectively.

  • PDF

Auto Correction Technique of Photography Composition Using ROI Extraction Method (ROI 추출을 통한 사진 구도 자동 보정 기법)

  • Ha, Ho-Saeng;Park, Dae-Hyun;Kim, Yoon
    • Journal of Information Technology and Architecture
    • /
    • v.10 no.1
    • /
    • pp.113-122
    • /
    • 2013
  • In this paper, we propose the method that automatically corrects the composition of a picture stylishly as well as reliably by cropping pictures based on the Rule of Thirds. The region of interest (ROI) is extracted from a picture by applying the Saliency Map and the Image Segmentation technology, the composition of the photo is amended based on this area to satisfy the Rule of Thirds. In addition, since the face region of the person is added to ROI by the Face Detection technique and the composition is amended by the various scenario according to ROI, the little more natural picture is acquired. The experimental result shows that the photo of the corrected composition was naturally amended compared with the original photo.