• Title/Summary/Keyword: photo sensitivity

Search Result 124, Processing Time 0.031 seconds

Infusion Pump용 Drop Sensor 개발에 관한 연구

  • Lee, Jong-Sil;Gwon, Jang-U;Lee, Eung-Hyeok;Park, Jeong-Seon;Gu, Ja-Il;Hong, Seung-Hong
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1995 no.11
    • /
    • pp.18-21
    • /
    • 1995
  • When we inject drugstuffs to a patient for a long time, it is important to control proper injection amount and flow rate. Since inproper injection amount and a flow rate would cause bad a recovery a patient, the relience of sensors which detect injection amount is an important factor for whole injection systems' performance. In this research, we've compared the suitability of three sensors for injection pump monitoring system. The three types of sensors, piezo film sensor, photo transistor made up with three transmitting photodiodes and receving photodiode, and photo array, were selected for comparing. Using suggested data processing technique and photo amy sensors, we could minimize the effect of interference, disturbance, illumanation change, and sensitivity change caused by sensor's position. According to the experiments, the photo amy showed the higher reliance than any other the three types of sensors. The developed systems could be the foundation of beginning home production of infusion pump system and available for the base model of whole monitoring and control systems.

  • PDF

Development and Characterization of Finger-type PIN Photodiode for Fluorescence Detection of RNA (RNA 형광 검출을 위한 Finger형 PIN 광다이오드의 제작 및 평가)

  • Kim, Ju-Hwan;Oh, Myung-Hwan;Ju, Byeong-Kwon
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.2
    • /
    • pp.85-89
    • /
    • 2004
  • This paper represents the development of high sensitivity photo-sensor for the fluorescence detection in the integrated biological analysis system. The finger-type PIN photodiodes were fabricated as the photo-sensor, and had a high sensitivity ($I_{light}/I_{dark}$ = 8720). The interference filter consisted of $TiO_{2}$ and $SiO_{2}$ was directly deposited on the photodiodes. Deposited filter with 95.5% reflection under 532 nm and 98% transmission over 580 nm exceedingly decreased the magnitude of background signal in the detection. The PDMS micro-fluidic channels are bonded on the photodiode by $O_{2}$ plasma treatment. The detection current was proportional to two primary parameters (light intensity, concentration), and the on-chip detection system could detect fluorescence signals down to 100 nM concentration (LOD = Limit of detection of rhodamine).

Fabrication and characteristic evaluation of microfluidics chip integrated OLED for the light sources (OLED광원이 집적화된 마이크로 플루이딕칩의 제작 및 특성 평가)

  • Kim, Young-Hwan;Han, Jin-Woo;Kim, Jong-Yeon;Kim, Byoung-Yong;Seo, Dae-Shik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.377-377
    • /
    • 2007
  • A simplified integration process including packaging is presented, which enables the realization of the portable fluorescence detection system. A fluorescence detection microchip system consisting of an integrated PIN photodiode, an organic light emitting diode (OLED) as the light source, an interference filter, and a microchannel was developed. The on-chip fluorescence detector fabricated by poly(dimethylsiloxane) (PDMS)-based packaging had thin-film structure. A silicon-based integrated PIN photo diode combined with an optical filter removed the background noise, which was produced by an excitation source, on the same substrate. The active area of the finger-type PIN photo diode was extended to obtain a higher detection sensitivity of fluorescence. The sensitivity and the limit of detection (LOD S/N = 3) of the system were $0.198\;nA/{\mu}M$ and $10\;{\mu}M$, respectively.

  • PDF

Sensing Characteristics of Uncoated Double Cladding Long-period Fiber Grating Based on Mode Transition and Dual-peak Resonance

  • Zhou, Yuan;Gu, Zheng Tian;Ling, Qiang
    • Current Optics and Photonics
    • /
    • v.5 no.3
    • /
    • pp.243-249
    • /
    • 2021
  • In this paper, the sensing characteristics of a double cladding fiber (DCF) long-period fiber grating (LPFG) to the surrounding refractive index (SRI) are studied. The outer cladding of the DCF plays the role of the overlay, thus, the mode transition (MT) phenomenon of DCF can be induced by etching the outer cladding radius instead of coating overlays. The response characteristics of the effective refractive index (ERI) of the cladding mode to the outer cladding radius are analyzed. It is found that in the MT range, the change rate of ERIs of cladding modes is relatively larger than that for other ranges. Further, based on the features of the mode transition region (MTR), the phase-matching curve of the 11th cladding mode is investigated, and the response of the DCF-LPFG to the SRI is characterized by the change of wavelength intervals between the dual peaks under different outer cladding radii. The numerical simulation results show that the SRI sensitivity is greatly improved, which is available to 3484.0 nm/RIU with the fitting degree 0.998 in the SRI range of 1.33-1.37. The proposed DCF-LPFG can provide new theoretical support for designing the DCF-LPFG refractive index sensor with excellent performances of sensitivity, linearity and structure.

fabrication of the Microfluidic LOC System with Photodiode (광 다이오드를 가진 Microfluidic LOC 시스템 제작)

  • 김현기;신경식;김용국;이상렬;김태송;양은경;주병권
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.12
    • /
    • pp.1097-1102
    • /
    • 2003
  • In this paper, we used only PR as etching mask, while it used usually Cr/AU as etching mask, and in order to fabricate a photosensor has the increased sensitivity, we investigated on the sensitivity of general type and p-i-n type diode. we designed microchannel size width max 10um, min 5um depth max 10um, reservoir size max 100um, min 2mm. Fabrication of microfluidic devices in glass substrate by glass wet etching methods and glass to glass fusion bonding. The p-i-n diode has higher sensitivity than photodiode, Considering these results, we fabricated p-i-n diodes on the high resistive(4㏀$.$cm) wafer into rectangle and finger pattern and compared internal resistance of each pattern. The internal resistance of pin diode can be decreased by the application of finger pattern has parallel resistance structure from 571Ω to 393Ω.

Catalytic combustion type hydrogen gas sensor using TiO2 and UV LED (TiO2 광촉매와 UV LED를 이용한 접촉연소식 수소센서)

  • Hong, Dae-Ung;Han, Chi-Hwan;Han, Sang-Do;Gwak, Ji-Hye;Lee, Sang-Yeol
    • Journal of Sensor Science and Technology
    • /
    • v.16 no.1
    • /
    • pp.7-10
    • /
    • 2007
  • A thick film catalytic gas sensors which can be operated at $142^{\circ}C$ in presence of ultra violet-light emitting diode has been developed to measure hydrogen concentration in 0-5 % range. The sensing material as a combustion catalyst consists of $TiO_{2}$ (5 wt%) and Pd/Pt (20 wt%) supported on $Al_{2}O_{3}$ powder and the reference material to compensate the heat capacity of it in a bridge circuit was an catalyst free $Al_{2}O_{3}$ powder. Platinum heater and sensor materials were formed on the alumina plate by screen printing method and heat treatment. The effect of UV radiation in the presence of photo catalyst $TiO_{2}$ on the sensor sensitivity, response and recovery time has been investigated. The reduction of operating temperature from $192^{\circ}C$ to $142^{\circ}C$ for hydrogen gas sensing property in presence of UV radiation is attributed to the hydroxy radical and superoxide which was formed at the surface of $TiO_{2}$ under UV radiation.

Economic Evaluation of Domestic Photobiological Hydrogen Production (국내 광생물학적 수소생산의 경제성 평가)

  • Gim, Bong-Jin;Kim, Jong-Wook
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.19 no.4
    • /
    • pp.322-330
    • /
    • 2008
  • This paper deals with an economic evaluation of domestic photobiological hydrogen production. We evaluate the economic feasibility of domestic photobiological hydrogen production utilizing green algae and cyanobacteria. In addition, we make some sensitivity analysis of hydrogen production prices by changing the values of input factors such as the price of a photo-bioreactor and the value of solar to hydrogen efficiency. The estimated hydrogen production price of the two-step indirect biophotolysis was 12,099won/kg$H_2$. It is expected that the hydrogen production price by the two-step indirect biophotolysis can be reduced to 2,143won/kg$H_2$ if the solar to hydrogen efficiency is increased to 10% and the price of a photo-bioreactor is decreased to $25/$m^2$. The two-step indirect biophotolysis is evaluated as uneconomical at this time, and we need to enhance the solar to hydrogen efficiency and to reduce the prices of the photo-bioreactor and system facilities.

Development of Ultra-High Pressure Capillary Reverse-Phase Liquid Chromatography/Tandem Mass Spectrometry for High-Sensitive and High-Throughput Proteomics

  • Kim, Min-Sik;Choie, Woo-Suk;Shin, Yong-Seung;Yu, Myeong-Hee;Lee, Sang-Won
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.12
    • /
    • pp.1833-1839
    • /
    • 2004
  • Recently mass spectrometry and separation methods such as liquid chromatography have become major tools in the field of proteomics. In this report, we describe in detail our efforts to develop ultra-high pressure capillary reverse-phase liquid chromatography (cRPLC) and its online coupling to a mass spectrometer by a nanoelectrospray (nanoESI) interface. The RPLC system is constructed in house to deliver LC solvents at the pressure up to 20,000 psig, which is four times higher than conventional RPLC systems. The high operation pressure allows the efficient use of packed micro-capillary columns (50, 75 and 150 ${\mu}$m i.d., up to 1.5 m long). We will discuss the effect of column diameter on the sensitivity of cRPLC/MS/MS experiments and the utility of the developed technique for proteome analysis by its application in the analysis of proteome samples having different levels of complexity.

Aqueous Glucose Solution Measurement by Three Types NIR Spectrometer (세 가지 방식의 근적외선 분광분석기를 이용한 글루코오스 수용액의 측정)

  • 백주현;강나루;우영아;김효진
    • YAKHAK HOEJI
    • /
    • v.47 no.6
    • /
    • pp.461-468
    • /
    • 2003
  • A method is described for measuring clinically relevant levels of glucose in a pH 7.4 phosphate buffer by nearinfrared (NIR) absorption spectroscopy. Three types of NIR spectrometer, dispersive type, photo-diode array (PDA) type, and fourier transform (FT) type spectrometer were used and the performance was compared. Spectra were collected with a cuvette cell or quartz liquid fiber of 1 mm or 2 mm optical pathlength as transmittance method. Glucose absorption band appeared at second overtone, first overtone, and combination region for all systems. By use of the multivariate technigue of partial least squares (PLS) regression, glucose concentrations can be determined with a 16, 44, and 9.1 mg/d l standard error of prediction for dispersive type, photo-diode array type, and fourier transform type system, respectively. Sensitivity of spectrometer was evaluated by absorbance for the difference of 10 mg/d l glucose. Three absorption bands, second overtone, first overtone, and combination region were suited to three types systems, dispersive type, photo-diode array type, and fourier transform type systems, respectively. This investigation showed that three types NIR spectrometer were proper method for identification and quantitative analysis of glucose and possible for noninvasive blood glucose monitoring.