• 제목/요약/키워드: phase type

검색결과 4,520건 처리시간 0.034초

흡착입자간 상호작용에 따른 흡착등온선 패턴 (Adsorption Isotherm Patterns According to the Interactions Between Adsorbed Particles)

  • 김철호
    • 한국재료학회지
    • /
    • 제23권8호
    • /
    • pp.462-468
    • /
    • 2013
  • We study and describe-from the point of view of the interactions of the adsorbed particles-three types of the adsorption isotherms, namely, Langmuir type adsorption isotherms, phase transition type adsorption isotherms, and adsorption limited type adsorption isotherms, which are observed by experiments. By introducing and using a one dimensional statistical occupancy model, we derived analytical adsorption isotherms for the no force, the attractive force, and the repulsive force exerted on the other adsorbed particles. Our derived adsorption isotherms qualitatively pretty well agree with the experimental results of the adsorption isotherms. To specify each adsorption type, Langmuir type adsorption is a phenomenon that occurs with no forces between the adsorbed particles, phase transition type adsorption is a phenomenon that occurs with the strong attractive forces between the adsorbed particles, and adsorption limited type adsorption is a phenomenon that occurs with the repulsive forces between the adsorbed particles. The theoretical analysis-only using fundamental thermodynamics and occupancy statistics though-qualitatively quite well explains the experimental results.

접지된 결합 C형 공진기를 이용한 X대역 전압제어 발진기 설계 및 구현 (Design and Implementation of VCO for X-band with Shorted Coupled C type Resonator)

  • 김종화;김기래
    • 한국정보전자통신기술학회논문지
    • /
    • 제9권6호
    • /
    • pp.539-545
    • /
    • 2016
  • 본 논문에서는 평면형 마이크로스트립 공진기를 이용한 고주파 발진기의 단점인 위상잡음 특성을 개선하기 위해 접지된 결합 C형 공진기를 제안하였다. 제안된 공진기를 이용하여 위상잡음 특성 개선 효과를 나타내기 위해 발진기를 설계하여, 9.8 GHz 기본 주파수에서 4.87dBm의 출력과 -84.7 dBc@100kHz의 위상잡음 특성을 나타내었다. 다음은 제안된 공진기에 버랙터다이오드를 추가하여 전압 제어발진기를 구현하였다. 전압 제어발진기의 특성은 최소 9.7807 GHz에서 최대 9.8145 GHz까지 33.8 MHz 정도의 튜닝범위를 가지고, -115~-112.5 dBc/Hz@100kHz의 위상잡음 특성을 갖는다. 본 논문의 발진기는 평면형 구조로 쉬운 작업공정과 소형화 특성 때문에 MIC 또는 MMIC 분야의 설계에 응용될 수 있을 것이다.

BRAZING CHARACTERISTICS BETWEEN CEMENTED CARBIDES AND STEEL USED BY AG-IN BRAZING FILLER

  • Nakamura, Mitsuru;Itoh, Eiji
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2002년도 Proceedings of the International Welding/Joining Conference-Korea
    • /
    • pp.551-554
    • /
    • 2002
  • As a general rule, the brazing process between cemented carbides and steel used by Silver (Ag) type brazing filler. The composition of Ag type filler were used Ag-Cu-Zn-Cd type filler mainly. But, the demand of Cadmium (Cd)-free in Ag type filler was raised recently. The reason why Cd-free in Ag brazing filler were occupied to vaporize as a CdO$_2$ when brazing process, because of Cd element was almost low boiling point of all Ag type filler elements. And, CdO$_2$ was a very harmful element for the human body. This experiment was developed Cd-freeing on Ag type filler that was used Indium (In) instead of Cd element. In this experiment, there were changed from 0 to 5% In addition in Ag brazing filler and investigated to most effective percentage of Indium. As a result, the change of In addition instead of Cd, there was a very useful element and obtained same property only 3% In added specimens compared to Cd 19% added specimens. These specimens were obtained same or more deflective strength. In this case, there were obtained 70 MPa over strength and wide brazing temperature range 650-800 C. A factor of deflective strength were influenced by composition and the shape of $\beta$ phase and between $\beta$ phase and cemented carbides interface. Indium element presented as $\alpha$ phase and non-effective factor directly, but it's occupied to solid solution hardening as a phase. $\beta$ phase were composed 84-94% Cu-Ni-Zn elements mainly. Especially, the presence of Ni element in interface was a very important factor. Influence of condensed Ni element in interface layer was increased the ductility and strength of brazing layer. Therefore, these 3% In added Ag type filler were caused to obtain a high brazing strength.

  • PDF

Evaluation of Volatile Compounds Isolated from Pork Loin (Longissimus dorsi) as Affected by Fiber Type of Solid-phase Microextraction (SPME), Preheating and Storage Time

  • Park, Sung-Yong;Yoon, Young-Mo;Schilling, M. Wes;Chin, Koo-Bok
    • 한국축산식품학회지
    • /
    • 제29권5호
    • /
    • pp.579-589
    • /
    • 2009
  • This study was conducted to investigate the effects of heating, fiber type used in solid-phase microextraction (SPME, two phase vs three phase) and storage time on the volatile compounds of porcine M. longissimus dorsi (LD). Volatile compounds were measured using a gas chromatography and mass spectrometry (GC/MS) with a quadrupole mass analyzer. Among the volatile compounds identified, aldehydes (49.33%), alcohols (24.63%) and ketones (9.85%) were higher in pre-heated loins ($100^{\circ}C$/30 min), whereas, alcohols (34.33%), hydrocarbons (22.84%) and ketones (16.88%) were higher in non-heated loins. Heating of loins induced the formation of various volatile compounds such as aldehydes (hexanal) and alcohols. The total contents of hydrocarbons, alcohols, and carboxylic acids were higher in two phase fibers, whereas those of esters tended to be higher in three-phase fibers (p<0.05). Most volatile compounds increased (p<0.05) with increased storage time. Thus, the analysis of volatile compounds were affected by the fiber type, while heating and refrigerated storage of pork M. longissimus dorsi increased the volatile compounds derived from lipid oxidation and amino acid catabolism, respectively.

Carrier Phase-Shift PWM to Reduce Common-Mode Voltage for Three-Level T-Type NPC Inverters

  • Nguyen, Tuyen D.;Phan, Dzung Quoc;Dao, Dat Ngoc;Lee, Hong-Hee
    • Journal of Power Electronics
    • /
    • 제14권6호
    • /
    • pp.1197-1207
    • /
    • 2014
  • Common-mode voltage (CMV) causes overvoltage stress to winding insulation and damages AC motors. CMV with high dv/dt causes leakage currents, which create noise problems for equipment installed near the converter. This study proposes a new pulse-width modulation (PWM) strategy for three-level T-type NPC inverters. This strategy substantially eliminates CMV. The principle for selecting suitable triangle carrier signals for the three-level T-type NPC is described. The proposed method can mitigate the peak value of CMV by 50% compared with the phase disposition pulse-width modulation method. Furthermore, the proposed method exhibits better harmonic spectrum and lower root mean square value for the CMV than those of the reduced-CMV method on the basis of the phase opposition disposition PWM scheme with modulation index higher than 0.5. The proposed modulation can easily be implemented using software without any additional hardware modifications. Both simulation and experimental results demonstrate that the proposed carrier phase-shift PWM method has good output waveform performance and reduces CMV.

New Resonant AC Link Snubber-Assisted Three-Phase Soft-Switching PWM Inverter and Its Comparative Characteristics Evaluations

  • Yoshida, Masanobu;Hiraki, Eiji;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • 제3권4호
    • /
    • pp.239-248
    • /
    • 2003
  • This paper presents a novel prototype of three-phase voltage source type zero voltage soft-switching inverter with the auxiliary resonant snubbers suitable for high-power applications with IGBT power module packages in order to reduce their switching power losses as well as electromagnetic conductive and radiative noises. A proposed single inductor-assisted resonant AC link snubber circuit topology as one of some auxiliary resonant commutation snubbers developed previously to achieve the zero voltage soft-switching (ZVS) for the three-phase voltage source type sinewave PWM inverter operating under the instantaneous space voltage vector modulation is originally demonstrated as compared with the other types of resonant AC link snubber circuit topologies. In addition to this, its operation principle and unique features are described in this paper. Furthermore, the practical basic operating performances of the new conceptual instantaneous space voltage vector modulation resonant AC link snubber-assisted three-phase voltage source type soft-switching PWM inverter using IGBT power module packages are evaluated and discussed on the basis of switching voltage and current waveforms, output line to line voltage quality, power loss analysis, actual power conversion efficiency and electromagnetic conductive and radiative noises from an experimental point of view, comparing with those of conventional three-phase voltage source hard-switching PWM inverter using IGBT power modules.

피스톤 펌핑 위상이 텐덤형 사판식 액셜 피스톤 펌프의 진동, 소음에 미치는 영향에 관한 연구(2) (A Study on Effects of Piston Pumping Phase on Vibration and Noises of Tandem Swash Plate Type Axial Piston Pump(2))

  • 박성환;이진걸
    • 한국정밀공학회지
    • /
    • 제16권12호
    • /
    • pp.31-39
    • /
    • 1999
  • Previous researches and experiments have already verified that the primary noise source of high pressure tandem axial thpe piston pump is fluid-borne noise from the process of oil distribution between the kidney-shaped port and valve plate. So, many researchers have improved pressure gradients and reduced sound levels by applying pre-compression and pre-decompression metering grooves to valve plate. In practice however, the sound level of th high pressure tandem axial type piston pump is still undesirable. This paper testified the effect of pumping phase of the piston on vibration and noise of th high pressure tandem axial type piston pump on the best of theoretical research in $this^(1)$. Therefore considering the pumping phase of the piston when assembling the tandem axial type piston pump, it is possible to reduce 1.5~2[dB]of sound level.

  • PDF

Reliability Models for Redundant Systems Using Phase-type Distributions

  • Moon, Sinmyeong;Lie, Changhoon
    • Management Science and Financial Engineering
    • /
    • 제7권2호
    • /
    • pp.73-90
    • /
    • 2001
  • This paper presents the reliability models for redundant systems composed of repairable components whose failure time and repair time distributions are phase-type. It is shown that the distribution of time to system failure is also phase-type. The dependency between components are considered and integrated into the model by the used of the rate adjustment factor. The phase-type representation is constructed for the system through algebraic operations on the parameters of components\` failure time and repair time distributions and the corresponding rate adjustment factors. Types of system structures considered are parallel, k-out-of-N system with load sharing scheme and standby system with operation priority.

  • PDF

Inverter 방식(方式) X선장치(X線裝置)의 임상응용(臨床應用) (Clinical Application of Inverter type X-ray Generator)

  • 이선숙;허준;이재원;김정민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제15권1호
    • /
    • pp.107-113
    • /
    • 1992
  • Inverter type X-ray apparatus has been introduced and used several hospitals. Principle of inverter type X-ray generators are such as to convert the frequency of commercial power supply to high frequency and to control the high voltages for X-ray tube. Inverter generators are now on the way for futher development to elliminate single phase generators and three phase generators. We compared inverter type X-ray apparatus with conventional single phase 2 peak and three phase 12 peak, apparatus in the following aspects X-ray out put to tube voltage, linearity of X-ray out put to mA, HVL according to mA contrast to kV.

  • PDF

THE DIMENSION REDUCTION ALGORITHM FOR THE POSITIVE REALIZATION OF DISCRETE PHASE-TYPE DISTRIBUTIONS

  • Kim, Kyung-Sup
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • 제16권1호
    • /
    • pp.51-64
    • /
    • 2012
  • This paper provides an efficient dimension reduction algorithm of the positive realization of discrete phase type(DPH) distributions. The relationship between the representation of DPH distributions and the positive realization of the positive system is explained. The dimension of the positive realization of a discrete phase-type realization may be larger than its McMillan degree of probability generating functions. The positive realization with sufficient large dimension bound can be obtained easily but generally, the minimal positive realization problem is not solved yet. We propose an efficient dimension reduction algorithm to make the positive realization with tighter upper bound from a given probability generating functions in terms of convex cone problem and linear programming.