• Title/Summary/Keyword: phase speed

Search Result 2,642, Processing Time 0.029 seconds

Speed Sensorless Control of Switched Reluctance Motor (스위치드 리럭턴스 전동기의 센서리스 속도제어)

  • Shin, Kyoo-Jae;Kwon, Young-Ahn
    • Journal of IKEEE
    • /
    • v.2 no.2 s.3
    • /
    • pp.166-172
    • /
    • 1998
  • Switched reluctance motor(SRM) has the advantages of simple structure, low rotor inertia and high efficiency. However, position sensor is essential in SRM in order to synchronize the phase excitation to the rotor Position. The Position sensors increase the cost of drive system and tend to reduce system reliability. This paper investigates the speed control of sensorless SRM in which the Phase current and change rate are utilized in position decision, and the period of dwell angle is variable for speed control. The proposed system consists of Position decision circuit, speed controller, digital logic commutator, switching angle controller and inverter The performances in the proposed system are verified through the experiment.

  • PDF

Development of Dual Beam High Speed Doppler OFDI

  • Kim, SunHee;Park, TaeJin;Oh, Wang-Yuhl
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.3
    • /
    • pp.283-288
    • /
    • 2013
  • This paper describes development of a high speed Doppler OFDI system for non-invasive vascular imaging. Doppler OFDI (optical frequency domain imaging) is one of the phase-resolved second generation OCT (optical coherence tomography) techniques for high resolution imaging of moving elements in biological tissues. To achieve a phase-resolved imaging, two temporally separated measurements are required. In a conventional Doppler OCT, a pair of massively oversampled successive A-lines is used to minimize de-correlation noise at the expense of significant imaging speed reduction. To minimize a de-correlation noise between targeted two measurements without suffering from significant imaging speed reduction, several methods have been developed such as an optimized scanning pattern and polarization multiplexed dual beam scanning. This research represent novel imaging technique using frequency multiplexed dual beam illumination to measure exactly same position with aimed time interval. Developed system has been verified using a tissue phantom and mouse vessel imaging.

A Delta-Sigma Fractional-N Frequency Synthesizer for Quad-Band Multi-Standard Mobile Broadcasting Tuners in 0.18-μm CMOS

  • Shin, Jae-Wook;Kim, Jong-Sik;Kim, Seung-Soo;Shin, Hyun-Chol
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.7 no.4
    • /
    • pp.267-273
    • /
    • 2007
  • A fractional-N frequency synthesizer supports quadruple bands and multiple standards for mobile broadcasting systems. A novel linearized coarse tuned VCO adopting a pseudo-exponential capacitor bank structure is proposed to cover the wide bandwidth of 65%. The proposed technique successfully reduces the variations of KVCO and per-code frequency step by 3.2 and 2.7 times, respectively. For the divider and prescaler circuits, TSPC (true single-phase clock) logic is extensively utilized for high speed operation, low power consumption, and small silicon area. Implemented in $0.18-{\mu}m$ CMOS, the PLL covers $154{\sim}303$ MHz (VHF-III), $462{\sim}911$ MHz (UHF), and $1441{\sim}1887$ MHz (L1, L2) with two VCO's while dissipating 23 mA from 1.8 V supply. The integrated phase noise is 0.598 and 0.812 degree for the integer-N and fractional-N modes, respectively, at 750 MHz output frequency. The in-band noise at 10 kHz offset is -96 dBc/Hz for the integer-N mode and degraded only by 3 dB for the fractional-N mode.

The Kinematical Analysis of Straddle Jump to Push up Motion on Sports Aerobics (스포츠 에어로빅스 Straddle Jump to Push up 동작의 운동학적 분석)

  • Kim, Cha-Nam
    • Korean Journal of Applied Biomechanics
    • /
    • v.12 no.2
    • /
    • pp.77-90
    • /
    • 2002
  • This study serves the purpose of understanding about correct jump and landing motion through Kinematical Analysis of Straddle Jump to Push up Motion at target by four elite sports aerobics athletes have more than four years career. And further more that make good assistance for coaches effective guidance through an offer basic data and correct diagnosis, evaluate of motions. It was picture-taked by two-video camera for Straddle Jump to Push up Motions. Camera speeds are 60 frame/sec. There are Kinematical Variation elements for analysis, the displacement of COG, each angle displacement left/right of shoulder-joint, each angle displacement left/right of knee-joint and each speed left/right of tip of the toes. Every each person accomplished severaly 3 times and we have acquired this conclusion. The conclusions were as follows; 1. Each situation for displacement of COG showed low height of COG by phase 1, 4, 5(79.05${\pm}9.07,\;46.41{\pm}3.65,\;18.66{\pm}0.54cm$) and It showed high height of COG by phase 2, 3($120.80{\pm}6.13,\;148.12{\pm}9.19cm$). 2. Each displacement left, right of shoulder-joint flexion by phase 1($91.07{\pm}8.30,\;90.77{\pm}5.72$deg/sec)and It showed maximal extension angles by phase 2($102.48{\pm}10.00,\;102.39{\pm}10.51$deg/sec). in part of phase 3, left of shoulder-joint angle($94.43{\pm}4.12$deg/sec) showed flexion phase 1, the other right shoulder-joint angle(88.38${\pm}$4.98deg/sec) showed more a little lower than phase 1, in last phase that showed most low by phase 4($70.58{\pm}13.72,\;54.24{\pm}11.58$deg/sec). 3. Each displacement left, right of hip joint showed maximal extent conditions by phase 2, 3($160.35{\pm}22.68,\;1534.77{\pm}5.40$deg/sec, $150.04{\pm}12.79,\;145.54{\pm}13.00$deg/sec) beside, ankle-joint showed minimal angle by phase 1, 4($93.59{\pm}18.92,\;85.37{\pm}13.23$deg/sec, $66.60{\pm}15.77,\;80.60{\pm}16.57$deg/sec). 4. Each displacement left, right of hip joint showed maximal extent conditions by phase 2($157.15{\pm}9.13,\;163.52{\pm}8.18$deg/sec), and right of hip joint showed minimal angle by phase 3($110.87{\pm}13.81,\;77.53{\pm}8.95$deg/sec) It showed alike condition of low angle by phase 1, 4($91.04{\pm}2.31,\;96.26{\pm}2.20$deg/sec). 5. Each displacement left, right of knee-joint showed maximal extent conditions by phase 1, 3, 4($173.46{\pm}2.95,\;171.51{\pm}5.44$deg/sec, $172.24{\pm}4.49,\;171.26{\pm}0.65$deg/sec, $162.78{\pm}2.13,\;164.10{\pm}5.97$deg/sec) but It showed flexion only left of knee-joint by phase 2($164.45{\pm}7.51,\;159.38{\pm}3.48$deg/sec). 6. Each speed left, right of the tip of the toes showed most fastest when someone jumped with lift up leges by phase 1, 2($321.32{\pm}67.91,\;316.90{\pm}41.97$cm/sec, $410.06{\pm}153.06,\;399.77{\pm}189.34$cm/sec), It showed more less speed than phase 1,2 by phase 3($169.74{\pm}67.17,\;150.00{\pm}63.80$cm/sec) and It showed most slow speed than phase 1,2,3 by phase 4($87.22{\pm}34.90,\;85.72{\pm}52.23$cm/sec).

Determination of Non-Steroidal Anti-Inflammatory Drugs in Human Urine Sample using HPLC/UV and Three Phase Hollow Fiber-Liquid Phase Microextraction (HF-LPME)

  • Cha, Yong Byoung;Myung, Seung-Woon
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.11
    • /
    • pp.3444-3450
    • /
    • 2013
  • Three phase hollow fiber-liquid phase microextraction (HF-LPME), which is faster, simpler and uses a more environmentally friendly sample-preparation technique, was developed for the analysis of Non-Steroidal Anti-Inflammatory Drugs (NSAIDs) in human urine. For the effective simultaneous extraction/concentration of NSAIDs by three phase HF-LPME, parameters (such as extraction organic solvent, pH of donor/acceptor phase, stirring speed, salting-out effect, sample temperature, and extraction time) which influence the extraction efficiency were optimized. NSAIDs were extracted and concentrated from 4 mL of aqueous solution at pH 3 (donor phase) into dihexyl ether immobilized in the wall pores of a porous hollow fiber, and then extracted into the acceptor phase at pH 13 located in the lumen of the hollow fiber. After the extraction, 5 ${\mu}L$ of the acceptor phase was directly injected into the HPLC/UV system. Simultaneous chromatographic separation of seven NSAIDs was achieved on an Eclipse XDB-C18 (4.6 mm i.d. ${\times}$ 150 mm length, 5 ${\mu}m$ particle size) column using isocratic elution with 0.1% formic acid and methanol (30:70) at a HPLC-UV/Vis system. Under optimized conditions (extraction solvent, dihexyl ether; $pH_{donor}$, 3; $pH_{acceptor}$, 13; stirring speed, 1500 rpm; NaCl salt, 10%; sample temperature, $60^{\circ}C$; and extraction time, 45 min), enrichment factors (EF) were between 59 and 260. The limit of detection (LOD) and limit of quantitation (LOQ) in the spiked urine matrix were in the concentration range of 5-15 ng/mL and 15-45 ng/mL, respectively. The relative recovery and precision obtained were between 58 and 136% and below 15.7% RSD, respectively. The calibration curve was linear within the range of 0.015-0.96 ng/mL with the square of the correlation coefficient being more than 0.997. The established method can be used to analyse of NSAIDs of low concentration (ng/mL) in urine.

Vector Control of Interior Permanent Magnet Synchronous Motor without Speed Sensor (속도센서 없는 매입형 영구자석 동기전동기의 벡터제어)

  • Choi, Jong-Woo;Lee, Seung-Hun;Kim, Heung-Geun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.7
    • /
    • pp.1241-1249
    • /
    • 2007
  • Lately, many approaches of speed sensorless control method for Interior Permanent Magnet Synchronous Motor(IPMSM) ha, been developed. This paper proposes a novel sensorless algorithm for speed estimation of IPMSM. First of all, proposes sensorless method estimates flux of rotor using foundational voltage equation of IPMSM and then estimates position and speed of rotor using Phase Locked Loop(PLL). Proposed sensorless algorithm demonstrated through simulation using Matlab simulink and experiment.

Propagation Speed of Torsional Waves in a Circular Rod with Harmonically Varying Material Properties

  • Kim, Jin-Oh
    • The Journal of the Acoustical Society of Korea
    • /
    • v.19 no.1E
    • /
    • pp.43-47
    • /
    • 2000
  • The paper describes a theoretical study on the speed of torsional elastic waves propagating in a circular rod whose material properties vary periodically as harmonic functions of the axial coordinate. An approximate solution for the phase speed has been obtained by using the perturbation technique for sinusoidal modulation of small amplitude. This solution shows that the wave speed in the nonuniform rod is dependent on the wave frequency as well as the periodic variation of the material properties. It implies that the torsional waves considered in this paper are dispersive even in the fundamental mode.

  • PDF

A Development of Single Action Press Robot (프레스 단동로봇의 개발)

  • 허성창;황병복
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1997.03a
    • /
    • pp.261-264
    • /
    • 1997
  • A single action press robot, which consists of a driving unit, rotator, up-down feed base and feed bar, is developed and applied for the press automation. The driving unit is made up with a face cam and blade cam, which have a phase angle. The feeding system consists of a double speed-up apparatus and linear motion guides, and has a fast motion characteristics. A horizontal feeding speed of the feed bar is increased twice by the double speed-up apparatus. The driving mechanism could be simplified due to the speed-up of the feeding unit.

  • PDF

3-Phase SR Drive System (범용 3상 SR Drive System)

  • Kim T.H.;Ahn J.W.;Park H.W.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.856-859
    • /
    • 2003
  • The switched reluctance motor(SRM) drive system provides a good adjustable speed and torque characteristics. However, because of the torque production mechanism, it also has some disadvantage such as higher torque ripple and fluctuation in speed. To reduce torque ripple and to control speed precisely, digital signal processor(BSP) is adopted. The DSP TMS320F241 was used to be realized this drive system. Test results show that the suggested control system has the ability of dynamic and precise speed control.

  • PDF

Effect of Rubber on Microcellular Structures from High Internal Phase Emulsion Polymerization

  • Park, Ji-Sun;Chun, Byoung-Chul;Lee, Seong-Jae
    • Macromolecular Research
    • /
    • v.11 no.2
    • /
    • pp.104-109
    • /
    • 2003
  • A microcellular, which combines a rubber with the conventional formulation of styrene/divinylbenzene/sorbitan monooleate/water system, was prepared using high internal phase emulsion (HIPE) polymerization. Although the open microcellular foam with low density from the conventional HIPE polymerization shows highly porous characteristics with fine, regular and isotropic structure, the one having much smaller cell size is desirable for various applications. In this study, a polybutadiene was introduced to reduce the cell size with comparable properties. Major interests were focused on the effects of rubber concentration and agitation speed on the cell sizes and compression properties. Scanning electron microscopy was used to observe the microcellular morphology and compression tests were conducted to evaluate the stress-strain behaviors. It was found that the cell size decreased as rubber concentration increased, reflecting a competition between the higher viscosity of continuous phase and the lower viscosity ratio of dispersed to continuous phases due to the addition of high molecular weight rubber into the oil phase of emulsion. A correlation for the average cell size depending on agitation speed was attempted and the result was quite satisfactory.