• Title/Summary/Keyword: phase angle detection

Search Result 86, Processing Time 0.022 seconds

Performance Comparison of GPS Fault Detection and Isolation via Pseudorange Prediction Model based Test Statistics

  • Yoo, Jang-Sik;Ahn, Jong-Sun;Lee, Young-Jae;Sung, Sang-Kyung
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.5
    • /
    • pp.797-806
    • /
    • 2012
  • Fault detection and isolation (FDI) algorithms provide fault monitoring methods in GPS measurement to isolate abnormal signals from the GPS satellites or the acquired signal in receiver. In order to monitor the occurred faults, FDI generates test statistics and decides the case that is beyond a designed threshold as a fault. For such problem of fault detection and isolation, this paper presents and evaluates position domain integrity monitoring methods by formulating various pseudorange prediction methods and investigating the resulting test statistics. In particular, precise measurements like carrier phase and Doppler rate are employed under the assumption of fault free carrier signal. The presented position domain algorithm contains the following process; first a common pseudorange prediction formula is defined with the proposed variations in pseudorange differential update. Next, a threshold computation is proposed with the test statistics distribution considering the elevation angle. Then, by examining the test statistics, fault detection and isolation is done for each satellite channel. To verify the performance, simulations using the presented fault detection methods are done for an ideal and real fault case, respectively.

A Study on the Precise End-Point Detection in Titration by Using the Phase Angle Measurements (위상각 측정에 의한 적정의 정확한 종말점 검출법에 관한 연구)

  • Park, Byung-Bin;Shin, Ho-Sang;Lee, Han-Hyoung
    • Analytical Science and Technology
    • /
    • v.12 no.4
    • /
    • pp.290-298
    • /
    • 1999
  • A study on the application of impedance phase angle for redox titration, acid-base titration, chelate titration and precipitation titration has been carried out. A constant alternating current was passed between two platinum electrodes. One of them was a polarizable micro-electrode of $0.1cm^2$ or $0.026cm^2$ surface area and the other a non-polarizable large electrode of $1cm^2$ surface area dipped in the solution to be titrated. The impedance and the phase angle of the titration cell were measured with lock-in amplifier to obtain well behaved titration curve respectively. In titration of oxalic acid vs. potassium permanganate, the end-point was obtained successfully from the phase angle titration curve. In this experiment, the concentration of 0.0005 M to 0.05 M, the current of $50{\mu}A$ and the frequency of near 50 Hz were used. In titration of phosphoric acid vs. sodium hydroxide, the first end-point was obtained successfully on the optimum experimental condition of 0.001 M concentration, $50{\mu}A$ current and 25~97 Hz frequency. However, the end-point in titration of cupric sulfate vs. disodium-EDTA couldn't be obtained clearly. The end-point was obtained with the out-of-phase impedance curve on the experimental condition of 0.01 M concentration, $100{\mu}A$ current, 5~35 Hz frequency range. In titration of sodium chloride vs. silver nitrate, the end-point was obtained successfully on the experimental condition of 0.1 M concentration, $100{\mu}A$ current and 5~47 Hz frequency range. This study showed that the impedance phase angle was applicable for the detection of the end-points in redox titration curve, acid-base titration curve, chelate titration curve and precipitation titration curve.

  • PDF

Evaluation of Regional Wall Motion by Phase Analysis of Radionuclide Cardiac Blood Pool Scintigrams in Coronary Artery Disease Patients (관상동맥질환 환자에서 방사성동위원소 위상분석에 의한 심근 국소 운동 평가)

  • Yi, Gang-Wook;Chung, June-Key;Oh, Byeong-Hui;Park, Young-Bae;Lee, Myung-Chul;Lee, Young-Woo;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.21 no.2
    • /
    • pp.167-174
    • /
    • 1987
  • Among noninvasive approaches for the evaluation of left ventricular performance, radionuclide ventriculography (RVG) has been shown to be of particular values. Phase analysis, recently introduced as more objective means for evaluating the temporal sequence of systolic ventricular wall motion than cine image of RVG comprises a pixel by pixel Fourier transformation of the time activity curve of a multiple gated acquisition equilibrium blood pool study. To examine the regional wall motion of ventricles in myocardial infarctions, we evaluated the phase image and histogram constructed for each ventricle by total phase angle range and full width of half maximum (FWHM). This study consisted of 7 normal subjects and 23 subjects with acute myocardial infarction. Contrast ventriculography and coronary angiography was performed in all partients with myocardial infarction. And we compared the result of phase analysis with cine image of RVG and examined the interrelationship between phase analysis and contrast ventriculography with coronary angiography. The results were as follows; 1) The total phase angle range and FWHM of LV phase histogram in myocardial infarction ($86^{\circ}\;and\;32^{\circ}$, repectively) were wider than those in normal control ($38^{\circ}\;and\;18^{\circ}$, respectively p<0.01). 2) RV phase angle range and FWHM in patients with right coronary artery (RCA) occlusion ($79^{\circ}\;and\;37^{\circ}$, respectively) were wider than those in normal control ($39^{\circ}\;and\;18^{\circ}$, respectively p<0.001) and the patients without RCA occlusion ($52^{\circ}\;and\;19^{\circ}$, respectively p<0.01). 3) Phase analysis was more sensitive (95%) than cine image of RVG (70%) for the detection of regional wall motion abnormality of LV.

  • PDF

A Study On the Diagnosis Breakdown Using Fractal Characteristics and the Method of Acoustic Emission in Low Density Polyethylene (프랙탈 특성과 음향방출 계측법을 이용한 LDPE 시료에서의 트리잉 파괴진단에 관한 연구)

  • Yoon, H.J.;Park, J.J.;Shin, S.J.;Choi, J.K.;Kim, S.H.;Kim, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1758-1760
    • /
    • 1997
  • Automatic detection system to detect acoustic emission pulse and fractal dimension were developed, to observe tree deterioration phenomena in LDPE. The purpose of our work are to use acoustic emission system and fractal dimension and to investigate the treeing phenomena in polymeric insulation under applied AC voltage 11[kV] with an artificial needle-shaped void(1.5[mm]) using the above system. We analyzed and phase angle-acoustic emission pulse amplitude-deterioration time ($\Phi$-AEA-t) pattern and phase angle-acoustic emission pulse number-deterioration time($\Phi$-AEN-t) pattern using statistical operators such as skewness, fractal dimension. In this paper show that the correlation of $\Phi$-AEA-t, $\Phi$-AEN-t, fractal dimension using regression analysis by the method of least squares can be used to predict the breakdown just before the breakdown occurs.

  • PDF

FPGA Based Robust Open Transistor Fault Diagnosis and Fault Tolerant Sliding Mode Control of Five-Phase PM Motor Drives

  • Salehifar, Mehdi;Arashloo, Ramin Salehi;Eguilaz, Manuel Moreno;Sala, Vicent
    • Journal of Power Electronics
    • /
    • v.15 no.1
    • /
    • pp.131-145
    • /
    • 2015
  • The voltage-source inverters (VSI) supplying a motor drive are prone to open transistor faults. To address this issue in fault-tolerant drives applicable to electric vehicles, a new open transistor fault diagnosis (FD) method is presented in this paper. According to the proposed method, in order to define the FD index, the phase angle of the converter output current is estimated by a simple trigonometric function. The proposed FD method is adaptable, simple, capable of detecting multiple open switch faults and robust to load operational variations. Keeping the FD in mind as a mandatory part of the fault tolerant control algorithm, the FD block is applied to a five-phase converter supplying a multiphase fault-tolerant PM motor drive with non-sinusoidal unbalanced current waveforms. To investigate the performance of the FD technique, the fault-tolerant sliding mode control (SMC) of a five-phase brushless direct current (BLDC) motor is developed in this paper with the embedded FD block. Once the theory is explained, experimental waveforms are obtained from a five-phase BLDC motor to show the effectiveness of the proposed FD method. The FD algorithm is implemented on a field programmable gate array (FPGA).

Sensorless speed control of a Switched Reluctance Motor using Fuzzy position estimation algorithm (퍼지회전자 위치평가 알고리즘을 이용한 SRM센서리스 속도제어에 관한 연구)

  • 최재동;김갑동;안재황;성세진
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.4
    • /
    • pp.343-351
    • /
    • 2000
  • This paper introduces a new rotor position estimation algorithm for the Switched Reluctance Motor, based on the magnetizing curves only at aligned and unaligned rotor positions. The flux linkage is calculated by measured data from phase voltage and phase current, and calculated data are used as the input of magnetizing profiles for rotor position detection. The fuzzy flux observer using novel knowledge-based fuzzy controller are presented to achieve sensorless control of the SRM. The method for selecting optimal angle is proposed for the rotor position detection. The robustness of the proposed algorithm is proved through the comparison of the simulation and experimental results.

  • PDF

Sensorless driving strategy of Single-Phase Hybrid SRM basing on Back-EMF detection (역기전력을 이용한 단상 하이브리드 SRM의 위치 추정 방법)

  • Tang, Ying;Lee, Donghee;Ahn, Jin-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.521-522
    • /
    • 2016
  • This paper presents a novel scheme to estimate the rotor position of a single-phase hybrid switched reluctance motor (HSRM). The proposed method uses the differential of back-EMF within a position region to estimate rotor position. By detecting the crossing-zero signal of back-EMF differential value, the minimum position of back-EMF corresponding to an absolute rotor position can be captured and used for position estimation four times in every mechanical rotation. In this way, a sensorless operation with adjustable turn on/off angle can be achieved without substantial computation. For the starting, two current comparators are adopted. The experimental verification using a prototype drive system is provided to demonstrate the viability of the proposed sensorless scheme.

  • PDF

New Control Scheme for 3 Phase PWM AC/DC Converter without Phase Angle Detection under Unbalanced Input Voltage Conditions (불평형 입력 전압 하에서 위상 검출이 없는 3상 PWM AC/DC 컨버터의 새로운 제어 기법)

  • 박규서;안성찬;현동석
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.3
    • /
    • pp.254-260
    • /
    • 2000
  • 일반적으로 3상 PWM AC/DC 컨버터는 정상상태에서의 효과적인 오차제거 및 빠른 과도응답 특성을 얻기 위해 동기좌표계상으로 모델링하여 제어한다. 그러나 이와 같은 제어기는 입력전압이 평형일 경우를 전제조건으로 하므로, 입력전압이 불평형일 경우 입력전류와 직류링크 전압에 2차 고조파 성분이 나타나게 된다. 본 논문에서는 불평형 입력전압 하에서 컨버터 시스템의 입력전류와 직류링크 전압에 발생하는 2차 고조파 성분을 최소화하기 위한 새로운 제어기법을 제안하였다. 입력측 역기전력 성분으로 간주할 수 있는 동기좌표계상의 전압을 입력전압의 상태에 따라 변동하였으며, 전류지령치를 무효전력과 2차 고조파 유효전력을 선택적으로 제거하도록 선정하였다. 입력전압의 분석은 동기좌표계상에서 수행되어지며, 각 상의 위상과 진폭의 검출이 불필요하다. 제안한 제어기법은 매우 간단하며 불평형 입력전압 상태에서 입출력 시스템의 고조파 왜란을 효과적으로 제어할 수 있다.

  • PDF

A New Start-up Method for a Load Commutated Inverter for Large Synchronous Generator of Gas-Turbine

  • An, Hyunsung;Cha, Hanju
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.201-210
    • /
    • 2018
  • This paper proposes a new start-up method for a load commutated inverter (LCI) in a large synchronous gas-turbine generator. The initial rotor position for start-up torque is detected by the proposed initial angle detector, which consists of an integrator and a phase-locked loop. The initial rotor position is accurately detected within 150ms, and the angle difference between the real position and the detected position is less than 1%. The LCI system operates in two modes (forced commutation mode and natural commutation mode) according to operating speed range. The proposed controllers include a forced commutation controller for the low-speed range, a PI speed controller and a PI current controller, where the forced commutation controller is connected to the current controller in parallel. The current controller is modeled by Matlab/Simulink, where a six-pulse delay of the thyristor and a processing delay are considered by using a zero-order hold. The performance of the proposed start-up method is evaluated in Matlab/Psim at standstill and at low speed. To verify the feasibility of the method, a 5kVA LCI system prototype is implemented, and the proposed initial angle detector and the system performance are confirmed by experimental results from standstill to 900rpm.

SLODAR System Development for Vertical Atmospheric Disturbance Profiling at Geochang Observatory

  • Ji Yong Joo;Hyeon Seung Ha;Jun Ho Lee;Do Hwan Jung;Young Soo Kim;Timothy Butterley
    • Current Optics and Photonics
    • /
    • v.8 no.1
    • /
    • pp.30-37
    • /
    • 2024
  • Implemented at the Geochang Observatory in South Korea, our slope detection and ranging (SLO-DAR) system features a 508 mm Cassegrain telescope (f /7.8), incorporating two Shack-Hartmann wave-front sensors (WFS) for precise measurements of atmospheric phase distortions, particularly from nearby binary or double stars, utilizing an 8 × 8 grid of sampling points. With an ability to reconstruct eight-layer vertical atmospheric profiles, the system quantifies the refractive index structure function (Cn2) through the crossed-beam method. Adaptable in vertical profiling altitude, ranging from a few hundred meters to several kilometers, contingent on the separation angle of binary stars, the system operates in both wide (2.5 to 12.5 arcminute separation angle) and narrow modes (11 to 15 arcsecond separation angle), covering altitudes from 122.3 to 611.5 meters and 6.1 to 8.3 kilometers, respectively. Initial measurements at the Geochang Observatory indicated Cn2 values up to 181.7 meters with a Fried parameter (r0) of 8.4 centimeters in wide mode and up to 7.8 kilometers with an r0 of 8.0 centimeters in narrow mode, suggesting similar seeing conditions to the Bohyun Observatory and aligning with a comparable 2014-2015 seeing profiling campaign in South Korea.