• 제목/요약/키워드: petrochemical wastewater

검색결과 38건 처리시간 0.019초

공기부상 생물막 반응기를 이용한 산업폐수 처리 (Wastewater Treatment using Air-lift Biofilm Reactor)

  • 최광수;한기백
    • 한국환경과학회지
    • /
    • 제9권4호
    • /
    • pp.351-367
    • /
    • 2000
  • Air-lift biofilm reactor should be an admirable process substituting conventional activated sludge process, because of its small area requirement as well as high volumetric loading capacity and stability against loading and chemical shocks. However most of the past research on the performance of ABR was focused on the sewage treatment. This research studied the applicability of ABR to treat high strength wastewater. A bench-scale ABR was operated to treat high strength synthetic wastewater, tannery wastewater and petrochemical wastewater, and its applicability was conclusive In case of synthetic wastewater, ABR showed good performance in which the substarate removal efficiency was higher that 80% even under short HRT(1.4 hr) and high volumetric loading rate(9.3 kgCODcr/$m^3$.day). When ABR was applied to treat tannery wastewater, it was suggested that the maximum volumetric loading rate and F/M ratio should be 7.7kgCODcr/$m^3$.day, 0.76 $day^{-1}$, respectively. And high substrate removal efficiency over than 90 % was observed with 4,000 mgCODcr/L of petrochemical wastewater. Even though effluent concentration was quite high, ABR should be applicable to treat the high strength wastewater, because of its high loading capacity.

  • PDF

석유화학계 기초화합물 제조시설과 합성수지 및 기타 플라스틱물질 제조시설의 폐수처리시설 BAT평가 (Assessment of Best Available Technology of Wastewater Treatment Facilities in Petrochemical Basic Compound Manufacturing and Plastics and Synthetic Resins Manufacturing)

  • 김영노;임병진;권오상
    • 한국물환경학회지
    • /
    • 제22권1호
    • /
    • pp.59-65
    • /
    • 2006
  • The effluent limitations for individual industry based on the best available technology economically achievable (BAT) have been required to achieve effective regulation. BAT assessment criteria that are suitable for the circumstances of Korean industry were developed in the previous study. The criteria were applied to determine the BAT for petrochemical basic compound manufacturing (PBCM) and plastics and synthetic resins manufacturing (PSRM) industry. Wastewater discharged from the each category contains high concentration of COD and toluene. Eighteen sites were surveyed and wastewater qualities were analyzed. Six and two different technologies were applied to the PBCM and PSRM industry for the end-of-pipe treatment process, respectively. The technology candidates were evaluated in terms of environmental impacts, economically achievability, treatment performance and economical reasonability. As the result, the technology options: typical activated-sludge process + sand filtration + activated carbon adsorption (PBCM) and wet oxidation + chemical precipitation + typical activated-sludge process + chemical precipitation (PSRM) were selected as the BAT for each industry.

석유화학폐수슬러지와 유기성 폐기물 혼합에 의한 연소특성 및 고형연료 폐기물화 재활용에 관한 연구 (A Study on Combustion Characteristics and Evaluating of RDFs(Refused Derived Fuels) from Mixture of Petrochemical Wastewater Sludge and Organic Matters)

  • 한영립;최영익
    • 한국환경과학회지
    • /
    • 제24권2호
    • /
    • pp.237-244
    • /
    • 2015
  • This objectives of research are to figure out combustion characteristics with increasing temperature with petrochemical sludge by adding wasted organic matters which are waste electric wire, anthracite coal and sawdust, and to exam heating value and ignition temperature for using refused derived fuels(RDFs). After analyzing TGA/DTG, petrochemical sludge shows a rapid weight reduction by vaporing of inner moisture after $170^{\circ}C$. Gross weight reduction rate, ignition temperature and combustion rates represent 68.6%, $221.9^{\circ}C$ and 54.1%, respectively. In order to assess the validity of the RDFs, the petrochemical sludge by adding wasted organic matters which are waste electric wire, anthracite coal and waste sawdust. The materials are mixed with 7:3(petrochemical sludge : organic matters)(wt%), and it analyzes after below 10% of moisture content. The ignition temperatures and combustion rates of the waste electric wire, anthracite coal and waste sawdust are $410.6^{\circ}C$, $596.1^{\circ}C$ and $284.1^{\circ}C$, and 85.6%, 30.7% and 88.8% respectively. In heating values, petrochemical sludge is 3,600 kcal/kg. And the heating values of mixed sludge (adding 30% of the waste electric wire, anthracite coal and waste sawdust) each increase up to 4,600 kcal/kg, 4,100 kcal/kg and 4,300 kcal/kg. It improves the ignition temperatures and combustion rates by mixing petrochemical sludge and organic matters. It is considered that the production of RDFs is sufficiently possible by using of petrochemical sludge by mixing wasted organic matters.

석유화학 폐수의 생물학적 처리시간 단축을 위한 오존 산화의 적용 (Application of Ozone Oxidation to Reduce the Biological Treatment Time of Petrochemical Wastewater)

  • 홍은식;김현석;이상희;정진석;신은우;류근갑;유익근
    • 대한환경공학회지
    • /
    • 제28권5호
    • /
    • pp.573-576
    • /
    • 2006
  • The efficacy of integrated ozone oxidation-biodegradation treatment was examined in the treatment of petrochemical wastewater with a special focus on the overall treatment time. When raw wastewater with chemical oxygen demand(COD) of 70-80 mg/L was oxidized by ozone, approximately 20% of initial COD was removed in less than 1.5 min at a dosing rate of 400 mg $O_3/L{\cdot}h $. No further decrease in COD was observed for the extended ozone treatment up to 30 min. Biological treatment alone showed a rapid reduction of COD to 40-50 mg/L, subsequently resulting in the decreased rate of COD removal. Pre-treatment by ozone before biological treatment did not significantly affect the specific rate of COD removal in a biological treatment. When ozone oxidation followed biological treatment, the extent of COD removal by ozone oxidation was greater compared to that of biologically-treated wastewater for a shorter time. Taken together, it was decided that the biological treatment time could be reduced if the treatment processes of concern will be properly arranged.

다중척도 의사결정 전략을 이용한 여수 석유화학단지의 폐수 중화망 설계 (Design for Wastewater Neutralization Network in Yeosu Petrochemical Complex by Multi-Criteria Decision Making Strategy)

  • 이태용
    • 청정기술
    • /
    • 제17권2호
    • /
    • pp.175-180
    • /
    • 2011
  • 생태산업단지의 산업 공생망 구성을 위한 다중척도 의사결정 전략을 개발하고 이를 여수산업단지의 산/염기성 폐수 중화망 설계에 적용하였다. 산(또는 염기)성 폐수는 화학산업에서 공통적으로 나오며, 다른 곳에서 나온 염기(또는 산)성 폐수를 자체적으로 중화할 수 있는 원료가 될 수 있다. 따라서 산/염기성 폐수가 대량으로 발생되는 석유화학산업단지에서 대규모의 산업 공생망을 구축할 수 있는 가능성을 지나고 있다. 본 연구에서는 산/염기성 폐수의 상호 중화를 위한 물질 흐름 모델을 구성하고, 여기에 다중척도의사결정 전략을 적용하여 최적이며 대등한 다수의 산업 공생망 후보를 설계하고 이들의 성능을 비교 분석하였다.

Petrochemical effluent treatment using natural coagulants and an aerobic biofilter

  • Bandala, Erick R.;Tiro, Juan Bernardo;Lujan, Mariana;Camargo, Francisco J.;Sanchez-Salas, Jose Luis;Reyna, Silvia;Moeller, Gabriela;Torres, Luis G.
    • Advances in environmental research
    • /
    • 제2권3호
    • /
    • pp.229-243
    • /
    • 2013
  • Coagulation-flocculation (CF) was tested coupled with an aerobic biofilter to reduce total petroleum hydrocarbon (TPHs) concentration and toxicity from petrochemical wastewater. The efficiency of the process was followed using turbidity and chemical oxygen demand (COD). The biofilter was packed with a basaltic waste (tezontle) and inoculated with a bacterial consortium. Toxicity test were carried out using Lactuca sativa var. capitata seeds. Best results for turbidity removal were obtained using alum. Considerable turbidity removal was obtained when using Opuntia spp. COD removal with alum was 25%, for Opuntia powder it was 36%. The application of the biofilter allowed the removal of 70% of the remaining TPHs after 30 days with a biodegradation rate (BDR) value 47 $mgL^{-1}d^{-1}$. COD removal was slightly higher with BDR value 63 $mgL^{-1}d^{-1}$. TPH kinetics allowed a degradation rate constant equal to $4.05{\times}10^{-2}d^{-1}$. COD removal showed similar trend with $k=4.23{\times}10^{-2}d^{-1}$. Toxicity reduction was also successfully achieved by the combined treatment process.

여수석유화학산단의 공선성 시험을 이용한 VOC 오염원 분류표 개발 (Development of the vac Source Profile using Collinearity Test in the Yeosu Petrochemical Complex)

  • 전준민;허당;황인조;김동술
    • 한국대기환경학회지
    • /
    • 제21권3호
    • /
    • pp.315-327
    • /
    • 2005
  • The total of 35 target VOCs (volatile organic compounds), which were included in the TO-14, was selected to develop a VOCs' source profile matrix of the Yeosu Petrochemical Complex and to test its collinearity by singular value decomposition(SVD) technique. The VOCs collected in canisters were sampled from 12 different sources such as 8 direct emission sources (refinery, painting, wastewater treatment plant, incinerator, petrochemical processing, oil storage, fertilizer plant, and iron mill) and 4 general area sources (gasoline vapor emission, graphic art activity, vehicle emission, and asphalt paving activity) in this study area, and then those samples were analyzed by GC/MS. Initially the resulting raw data for each profile were scaled and normalized through several data treatment steps, and then specific VOCs showing major weight fractions were intensively reviewed and compared by introducing many other related studies. Next, all of the source profiles were tested in terms of degree of collinearity by SVD technique. The study finally could provide a proper VOCs' source profile in the study area, which can give opportunities to apply various receptor models properly including chemical mass balance (CMB).

석유화학공장 방류수내 난분해성 유기물의 Fenton 산화처리 (Fenton난s Reagent Oxidation of Refractory Organics in Petrochemical Plant Effluent)

  • 이규훈;정대영;박태주
    • 한국환경과학회지
    • /
    • 제5권1호
    • /
    • pp.51-59
    • /
    • 1996
  • The purpose of this study was to evaluate the partial oxidation of the biological treatment plant effluents using Fenton's reagent as a pretreatment step prior to a tertiary biological oxidation of these effluents. Fenton's reagent was evaluated as a pretreatment process for inhibitory or refractory organics. Based on the Fenton oxidation system, the petrochemical wastewater treatment plant effluent was shown to have significant improvement in toxicity after oxidation with hydrogen peroxide. For example, at ranee of 42 ∼ 184 mg/L COD of petrochemical plant effluents, the COD removal efficiencies were from 38.2% to 60.1% after reaction with hydrogen peroxide 200 mg/L and Fe2+ 100 mg/L and reaction time was 30 minutes. The total TOC reduction were about 15.8∼22.4% with same test condition and difference between the overall removal rate and BOD/COD ratio after Fenton's oxidation estabilished in the biodegradation and otherwise meets the discharge standard or reuse for cooling tower make-up water.

  • PDF

Water quality big data analysis of the river basin with artificial intelligence ADV monitoring

  • Chen, ZY;Meng, Yahui;Wang, Ruei-yuan;Chen, Timothy
    • Membrane and Water Treatment
    • /
    • 제13권5호
    • /
    • pp.219-225
    • /
    • 2022
  • 5th Assessment Report of the Intergovernmental Panel on Climate Change Weather (AR5) predicts that recent severe hydrological events will affect the quality of water and increase water pollution. To analyze changes in water quality due to future climate change, input data (precipitation, average temperature, relative humidity, average wind speed, and solar radiation) were compiled into a representative concentration curve (RC), defined using 8.5. AR5 and future use are calculated based on land use. Semi-distributed emission model Calculate emissions for each target period. Meteorological factors affecting water quality (precipitation, temperature, and flow) were input into a multiple linear regression (MLR) model and an artificial neural network (ANN) to analyze the data. Extensive experimental studies of flow properties have been carried out. In addition, an Acoustic Doppler Velocity (ADV) device was used to monitor the flow of a large open channel connection in a wastewater treatment plant in Ho Chi Minh City. Observations were made along different streams at different locations and at different depths. Analysis of measurement data shows average speed profile, aspect ratio, vertical position Measure, and ratio the vertical to bottom distance for maximum speed and water depth. This result indicates that the transport effect of the compound was considered when preparing the hazard analysis.

석유화학공업 폐수중 다환방향족 탄화수소류에 관한 조사연구 (An Analytical Study on The Polycyclic Aromatic Hydrocarbons of Wastewater Effluents from Petrochemical Industries)

  • 한희정;박석환;정문식
    • 한국환경보건학회지
    • /
    • 제20권3호
    • /
    • pp.1-12
    • /
    • 1994
  • Wastewaters being treated and final effluents were collected from 3 wastewater treatment plants of petrochemical industries, from August 31 to October 4, 1993 in an interval of 10 days, and further analysed by GC/FID to investigate discharge situation and removal efficiency on polycyclic aromatic hydrocarbons. The results were as follows: 1. The PAHs 294.57 $\mu$g/l were discharged in primary treatment effluent of plant A to manufacture vinyl acetate resin and acryl, and removed 54.51% by aeration and totally 84.71%. 2. The PAHs of the highest concentration were discharged in primary treatment effluent of plant B to manufacture PS resin and ABS resin, but removed 91.65% by activated sludge process and 98.19% by activated carbon to discharge PAHs of the lowest concentration comparing to another treatment operations. 3. The PAHs 99.96 $\mu$g/l of the lowest concentration were discharged in wastewater of plant C to manufacture epoxy resin, and removed 80.48% by activated sludge process. 4. B treatment system including activated carbon showed up the best removal efficiency of PAHs. Activated carbon therefore, seems to be effective as tertiary treatment. 5. Correlation coefficient of components to total PAHs was generally low, and correlation coefficients of phenanthrene, pyrene and acenaphthylene to total PAHs were each 0.98, 0.97 and 0.80, respectively. Correlation coefficient of the sum of phenanthrene, pyrene and acenaphthylene to total PAHs was 0.99, so that the sum of phenanthrene, pyrene and acenaphthylene was available as index to estimated total PAHs. 6. Phenanthrene and Chrysene were very well treated biologically and acenaphthylene and fluoranthene were untreated biologically. 7. Considering EPA standards, it seems that the concentration of phenanthrene, pyrene, fluoranthene, and benzo(k)fluoranthene is high level.

  • PDF