• Title/Summary/Keyword: persistent mode

Search Result 68, Processing Time 0.023 seconds

Performance Improvement of Ethernet using Dynamic Mode Change (동적 모드 변환을 이용한 이더넷 성능 개선)

  • 황민태;윤일환;이재조
    • Journal of Korea Multimedia Society
    • /
    • v.4 no.4
    • /
    • pp.349-355
    • /
    • 2001
  • In this paper, we newly propose a performance enhanced CSMA/CD MAC(Medium Access Control) protocol for the Ethernet which changes its operation mode dynamically according to the network status, not fixed it as one of p-persistent mode and non-persistent mode. Dynamic mode change occurs independently on each node, and uses the consecutive success count and the fail count of the frame transmission. The simulation result shows that the dynamic mode change maintains the enhanced network utilization and transmission delay characteristics. Also we show the implementation simplicity of our MAC protocol through its conceptual design using the Ethernet commercial chip as it stands.

  • PDF

A MIMO VSS with an Integral-Augmented Sliding Surface for Uncertain Multivariable Systems (불확실 다변수 시스템을 위한 적분 슬라이딩 면을 갖는 다입출력 가변 구조 제어기)

  • Lee, Jung-Hoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.5
    • /
    • pp.950-960
    • /
    • 2010
  • In this paper, a multi-input multi-output(MIMO) integral variable structure system with an integral-augmented sliding surface is designed for the improved robust control of uncertain multivariable system under the matched persistent disturbance. To effectively remove the reaching phase problems, the integral augmented sliding surface is proposed. Then for its design, the eigenstructure assignment technique is introduced to. To guarantee the designed performance against the persistent disturbance, the stabilizing control for multi-input system is also designed to generate the sliding mode on the integral sliding surface. The stability of the global system together with the existence condition of the sliding mode are investigated and proved for the case of multi input system in the presence of uncertainty and disturbance. The reaching phase is completely removed in proposed MIMO VSS by satisfying the two requirements. An example and computer simulations will be present for showing the usefulness of algorithm.

Energization method of Superconducting Magnet System with Persistent Current Mode (영구전류모드를 가지는 초전도 마그네트 시스템의 여자방법)

  • Ye, Jung-Hee;Nah, Wan-Soo;Joo, Jin-Ho;Hong, Gye-Won
    • Proceedings of the KIEE Conference
    • /
    • 1998.07a
    • /
    • pp.305-307
    • /
    • 1998
  • One of the merits of superconducting magnet system is that it has persistent current mode, in which the current can be constant without any external power supply. The problem is that when we energize the magnet we can not reach the target current with constant current source, in principle. It needs another energization methods, in which it can be energized with reasonable accuracy and time. This paper suggests two energization methods for a superconducting magnet with persistnet current mode and the comparisons of the two are made with respect to the accuracy and the time.

  • PDF

2D numerical study of the mechanical behaviour of non-persistent jointed rock masses under uniaxial and biaxial compression tests

  • Vaziri, Mojtaba Rabiei;Tavakoli, Hossein;Bahaaddini, Mojtaba
    • Geomechanics and Engineering
    • /
    • v.28 no.2
    • /
    • pp.117-133
    • /
    • 2022
  • Determination of the mechanical behaviour of jointed rock masses has been a challenge for rock engineers for decades. This problem is more pronounced for non-persistent jointed rock masses due to complicated interaction of rock bridges on the overall behaviour. This paper aims to study the effect of a non-persistent joint set configuration on the mechanical behaviour of rock materials under both uniaxial and biaxial compression tests using a discrete element code. The numerical simulation of biaxial compressive strength of rock masses has been challenging in the past due to shortcomings of bonded particle models in reproducing the failure envelope of rock materials. This problem was resolved in this study by employing the flat-joint contact model. The validity of the numerical model was investigated through a comprehensive comparative study against physical uniaxial and biaxial compression experiments. Good agreement was found between numerical and experimental tests in terms of the recorded peak strength and the failure mode in both loading conditions. Studies on the effect of joint orientation on the failure mode showed that four zones of intact, transition to block rotation, block rotation and transition to intact failure occurs when the joint dip angle varies from 0° to 90°. It was found that the applied confining stress can significantly alter the range of these zones. It was observed that the minimum strength occurs at the joint dip angle of around 45 degrees under different confining stresses. It was also found that the joint orientation can alter the post peak behaviour and the lowest brittleness was observed at the block rotation zone.

Fabrication and Test of Persistent Current Switch for HTS Magnet System

  • Hyoungku Kang;Kim, Jung-Ho;Jinho Joo;Yoon, Yong-Soo;Ko, Tae-Kuk
    • Progress in Superconductivity and Cryogenics
    • /
    • v.5 no.1
    • /
    • pp.92-96
    • /
    • 2003
  • This paper deals with the characteristics of persistent current switch (rCS) system fer applied HTS magnet system. To apply the high-Tc superconductor in superconducting machine such as motror, generator, MAGLEV, MRI, and NMR, the study on high-Tc superconducting persistent current mode must be performed. In this experiment, the PCS system consists otd superconducting magnet, PCS and magnet power supply. The superconducting magnet was fabricated by connecting four double pancake coils (DPCs) in series. The PCS was inductive double pancake coil type and heated up by the SUS 303L tape heater. The optimal length of PCS was calculated and thermal quench state of PCS was simulated by using finite element method(FEM) and compared with experimental results. The optimal energy to normalize the PCS was calculated and introduced. Finally, the persistent current was observed with respect to various ramping up rate and magnitude of charging current.

Potential Health Risks from Persistent Organic Pollutants (POPs) in Marine Ecosystem

  • Lee, Youn Ju;Jang, Jae-Seok;Yang, Jae-Ho
    • Journal of Marine Bioscience and Biotechnology
    • /
    • v.8 no.1
    • /
    • pp.10-17
    • /
    • 2016
  • A wide-spread contamination of persistent organic pollutants (POPs) such as dioxins, PCBs, PBDEs in the aquatic ecosystem has generated a great concern over the potential risk for these substances to impact marine biotas and food web. Since a major exposure route of these substances to the humans is through the consumption of food including fish and marine byproducts, the consumption of contaminated products has been a great public health concern. Exposure to POPs has been associated with a wide spectrum of adverse effects including reproductive, developmental, immunologic, carcinogenic, and neurotoxic effects. This review covers the background information of key POPs substances and the recent development of toxicity studies including the mode of action. Because neurotoxic effects of some POPs have been observed in humans at low concentrations, polychlorinated biphenyl (PCB), a representative chemical of POPs, is focused to discuss the possible mode(s) of action for the neurotoxic effects. This review provides the updates of toxicity studies on POPs and paves ways to discuss a possible implication of contaminated marine biota over the human health among the marine biotechnology researchers.

Magnet applications of HTS wires

  • Oh, Sang-Soo
    • 한국초전도학회:학술대회논문집
    • /
    • v.10
    • /
    • pp.27-34
    • /
    • 2000
  • HTS wires processed by PIT method are now available for magnet applications. But, those wires can not be used over 40 K due to weak link. This leads to necessity of development of coated conductor which can retain high $J_c$ at high field in liquid nitrogen. In this paper, various technical issues and the R&D status for both PIT wires and coated conductor were discussed. The difference of coated conductor's processes were also investigated and summarized. Various requirements for a design of HTS magnets were discussed. Anisostropic $J_c$ property with respect to magnetic field was considered to determine the coil's critical current. Low n value is a critical parameter to degrade a field stability with respect to time for a persistent mode HTS magnet. The relation between the margin of operation current and n value was investigated. Prototype HTS magnets with PIT wires are being developed for various applications such as crystal growth, MRI, magnetic separator and etc. HTS magnets will come into wide use in various fields of industries if the HTS wires with a low performance cost is developed.

  • PDF

The distribution characteristics of persistent organic pollutants in incineration residues at solid waste incinerators (소각시설 소각재의 잔류성 유기오염 물질 분포특성)

  • Kim, Jong-Hyang;Lee, Bang-Hee;Baek, Sung-Bok;Lee, In-A;Lee, Sang-Hee;Park, Kyung-Ho;Kim, Hyun
    • Analytical Science and Technology
    • /
    • v.22 no.2
    • /
    • pp.119-127
    • /
    • 2009
  • This study was carried out to investigate the distribution characteristics of persistent organic pollutants in incineration residues at industrial waste incinerators and municipal solid waste incinerators, which were analyzed by the official analytical method for the endocrine disrupting chemicals and the waste. Seven of 12 persistent organic pollutants were quantitatively analyzed by GC-MSD (SIM-mode). Hexachlorobenzene was detected in 21 samples among 44 incineration residues. The level of hexachlorobenzene was 0.132-8.138 ng/g in incineration residues, 0.195-5.765 ng/g in fly ash at industrial waste incinerators, 0.270-1.828 ng/g in bottom ash and 0.154-50.643 ng/g in fly ash at municipal solid waste incinerators, respectively.

Temperature dependency of magnetic field drifts of HTS pancake coils for NMR/MRI applications

  • Choi, Kyeongdal;Lee, Seyeon;Kim, Woo-Seok;Lee, Sang Min
    • Progress in Superconductivity and Cryogenics
    • /
    • v.15 no.4
    • /
    • pp.44-47
    • /
    • 2013
  • We had proposed a winding method so called "Wind-and-Flip", which enables a persistent current operation of an HTS pancake coil without any electrical joint. In order to improve the magnetic field drift characteristics, a prototype HTS coil with the technique was fabricated, and tested under various temperatures. Because the coil doesn't have any electric terminals for current leads, an HTS background magnet was used to induce the persistent current in the coil by field cooling process. A conduction cooling system with a GM cryocooler was prepared to keep the operating temperatures of the prototype coil much below the 77 K. We investigated the magnetic field drift characteristics under the various operating temperatures by measuring the center magnetic field with a cryogenic Hall sensor. The persistent current mode operation at 20 ~ 50K showed a strong possibility of the winding technique for the application such as MRI or NMR.

Characteristics Analysis of a Small Scale Persistent Current Switch System by using Coated Conductor (Coated Conductor를 이용한 소용량 영구전류스위치 시스템의 특성 해석)

  • Kim, Yeong-Sik;Yoon, Yong-Soo;Yang, Seong-Eun;Park, Dong-Keun;Ahn, Min-Cheol;Ko, Tae-Kuk
    • Progress in Superconductivity and Cryogenics
    • /
    • v.9 no.1
    • /
    • pp.47-52
    • /
    • 2007
  • This paper presents characteristics analysis of persistent current switch(PCS) system on a small scale by using YBCO coated conductor(CC). A high temperature superconductor(HTS) PCS system mainly consists of a PCS, a HTS magnet load and a magnet power supply(MPS). To design the optimal heater triggering switch. the three-dimensional heat conduction model was analyzed by finite element method(FEM). The electrical equivalent model considering the n-value of CC was applied to analyze current decay during persistent current mode. In the experiment and simulation, the heater was applied with a current of 0.43A and the current was ramped up to 10A and 20A with 0.2A/s. Finally, experimental results of the HTS PCS system have been compared with the theoretical results. It has been concluded that flux creep can not influence the results because the operating current was 40% of critical current and optimal sequential operation of the PCS system is indispensable to enhance its performance.