• Title/Summary/Keyword: permissible

검색결과 693건 처리시간 0.034초

전동차 실내의 적정 환기율 및 이산화탄소 농도 기준치에 관한 고찰 (A survey of the optimal ventilation rate and the permissible CO2 concentration in the saloon)

  • 조용성;강석택;박영훈
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 추계학술대회 논문집
    • /
    • pp.312-317
    • /
    • 2005
  • Electric Multiple Unit is one of the major mass public transportation systems and passengers are under the influence of indoor air quality such as air temperature, relative humidity and concentration of CO2 gas. Therefore ventilation system of Electric Multiple Unit should be designed for both healthy and comfortable environments. We survey the optimal ventilation rate and the permissible CO2 concentration in the saloon with the consideration of the cooling and heating capacity and fresh air induced from tunnel.

  • PDF

식생매트 허용 소류력 평가를 위한 실규모 실험 연구 (A Real Scale Experimental Study for Evaluation of Permissible Shear Stresses on Vegetation Mats)

  • 이두한;김동희;김명환;이동섭
    • 한국산학기술학회논문지
    • /
    • 제13권12호
    • /
    • pp.6151-6158
    • /
    • 2012
  • 친환경 하천사업의 활성화로 식생매트의 사용은 증가하고 있으나 수리적 안정성에 대한 평가는 미흡한 실정이다. 본 연구는 호안용 식생매트 제품의 객관적인 수리안정성 시험 기법 개발을 위해 수행하였다. 이를 위해서 식생매트 2종에 대한 실규모 실험을 수행하여 수리량을 측정하고 분석하여 작용 소류력을 계산하였다. 1차원 부정류 모형을 이용하여 최적 조도계수를 결정하고 작용 소류력을 계산하였다. 각 유량의 시험 후에는 매트 표면 및 기반층의 변동 여부를 기록하여 평가하였으며 이에 따라 매트표면의 손상 유형 3가지 및 기반층의 손상 유형 2가지를 제시하였다. 본 연구에서는 식생매트의 표면 변동이 있더라도 하부 기반층의 유실이 발생하지 않는 경우에는 안정한 상태로 제안하였다. 이에 따라 실험체 2종의 허용소류력을 평가하였으며 철망으로 보강된 식생매트가 허용 소류력 측면에서 효과가 있는 것을 확인할 수 있었다.

토양 손실 평가에 의한 식생매트의 허용 소류력 결정 (Determination of Permissible Shear Stresses on Vegetation Mats by Soil Loss Evaluation)

  • 이두한;이동섭;김명환
    • 한국산학기술학회논문지
    • /
    • 제14권11호
    • /
    • pp.5956-5963
    • /
    • 2013
  • 친환경 하천사업의 활성화로 식생매트의 사용은 증가하고 있으나 수리적 안정성에 대한 평가기법은 제시되지 않은 실정이다. 본 연구는 호안용 식생매트 제품의 객관적인 수리안정성 시험 기법 개발을 위해 수행하였다. 이를 위해서 식생매트 2종에 대한 실규모 실험을 수행하여 수리량을 측정하고 분석하여 작용 소류력을 계산하였다. 작용 소류력에 대한 토양손실평가를 위하여 지상라이다에 의한 측량을 수행하고 실험 전후의 하상고 변화를 평가하여 토양손실지수(CSLI)를 산정하였으며, 작용 소류력과 함께 도시하여 허용 소류력을 정량적으로 평가하였다. 하상고에 대한 정밀 측량 결과 분석에 의해서 식생매트가 안정한 경우에는 하상 변동이 국부적으로 제한되나, 불안정으로 판정되는 경우에는 식생매트 하부에서 비교적 큰 규모의 하상 변동이 발생하며 이는 자연 하상의 거동과 유사함을 확인하였다. 이상의 연구를 통해서 ASTM D 6040에 의한 식생매트의 허용 소류력 평가가 파괴 메카니즘 및 토양손실판정 기준에서 유효함을 확인할 수 있었다.

점착성 제방사면의 구간별 소류력 산정식 제안 및 적용 (A Suggestion of Formulae to Calculate Sectional Tractive Force on the Slope of Cohesive River Bank and its Application)

  • 한만신;최계운
    • 한국수자원학회논문집
    • /
    • 제45권6호
    • /
    • pp.583-596
    • /
    • 2012
  • 호안은 제방을 보호하기 위하여 제방법면에 설치되는 구조물로써, 국내 외 설계기준에 의하여 호안을 설계할 때, 하상과 호안법면에서의 최대 소류력을 산정하여 제방 사면에 평균적인 개념으로 적용하고 있다. 제방 사면의 허용소류력을 산정하는 경우에는 비점착성 토사를 기준으로 사면의 흘러내림을 고려하지만, 본 연구에서는 0 < ${\Phi}$ < $90^{\circ}$ 의 경사를 갖는 점착성 제방 단면의 구간별 소류력 공식을 제안하였으며, 호안의 식생밀도와 공법 재료 변화에 따른 허용소류력을 산정하였다. 구간별 소류력을 산정하기 위하여 길이 20m, 폭 2m의 개수로를 설치하였고, 유량 조건을 변화하면서 수리모형실험을 수행하였다. 제방 사면의 구간별 허용소류력을 산정한 결과 호안 재료 변화에 따라서는 조도가 큰 공법의 허용소류력이 가장 크게 산정되었으며, 식생밀도에 의한 영향으로는 식생이 있는 경우 저항에 의하여 허용소류력이 증가되었지만, 밀도변화에 의하여는 큰 차이가 나타나지 않았다.

벤젠의 국내 허용기준에 대한 연도별 초과 경향 연구 (A Survey on Annual Exceedance Trends for the Domestic Permissible Exposure Limit for Benzene)

  • 이경화;김기연
    • 한국산업보건학회지
    • /
    • 제28권2호
    • /
    • pp.144-150
    • /
    • 2018
  • Objectives: The purpose of this study is to analyze the trend for exceedance of the domestic permissible exposure limit of benzene based on a review of the previous literature. Materials and methods: From among 13 chemical substances regulated through a PEL (Permissible Exposure Limit) in the Occupational Safety and Health Act, the research object of this study is benzene. The information utilized is work environment measurement data from 2004 to 2013. The highest level among the concentration data measured at various workplaces was selected as a representative value through the data process. N.D. (Not Detected) data was considered as 1/2 of the LOD (limit of detection). Results: Among the work environment measurement data between 2004 and 2013, the highest number of exceeding workplaces and the excess rate (12 sites and 5.4%) was observed in the 2006 data when applying the current PEL for benzene. When compared with the action level, which means a level one-half of the PEL, 2005's data showed the highest number of exceeding workplaces and greatest excess rate (89 sites & 13.3%). The number of exceeding workplaces and excess rate relative to the PEL for benzene showed an increasing trend in 2004, but tended to decrease after 2007. Conclusions: Based on the results obtained from this study, the exposure level for benzene among domestic workers is not considered to be in a safe phase regardless of the year of work environment measurement. Thus, strict preventive management in workplaces should be provided for reducing exposure to benzene.

주파수 응답함수를 이용한 고정밀 장비의 진동허용규제치 결정기법에 관한 연구 (A Study on the Vibration Criteria Decision for High Technology Facilities using FRF)

  • 이홍기;김두훈;김사수
    • 소음진동
    • /
    • 제6권3호
    • /
    • pp.363-373
    • /
    • 1996
  • In the case of a precision equipment, it requires a vibration free environment to provide its proper function. Especially, lithography and inspection devices, which have sub-nanometer class high accuracy and resolution, have come to necessity for producing more improved giga class semiconductor wafers. This high technology equipments require very strict environmental vibration standard in promotion to the accuracy of the manufacturing, inspecting devices. The vibration criteria are usually obtained either by the real vibration exciting test on the equipment or by the analytical calculation. The former is accurate but requires a great deal of time and efforts while the latter lacks reliability. This paper proposes a new method to solve this problem at a time. The permissible vibration level to a precision equipment can be easily obtained by analyzing the process of Frequency Response Function(FRF). This paper also demonstrates its effectiveness by applying the proposed method to finding the permissible vibration criteria of a Computer Hard Disk Drive.

  • PDF

등입도 투수성 콘크리트 보강 조립토 다짐말뚝의 거동특성 및 침하량 평가기법 (A Estimation Method of Settlement and The Behaviour Characteristics of Granular Compaction Pile Reinforced with Uniformly Graded Permissible Concrete)

  • 김정호;황정순;김승욱;김종민;김홍택
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2006년도 춘계 학술발표회 논문집
    • /
    • pp.362-371
    • /
    • 2006
  • The behaviour characteristics of Granular Compaction Pile(GCP) are mainly governed by the lateral confining pressure mobilized in the matrix soft soil to restrain the bulging failure of the granular compaction pile. The GCP method is most effective in soft soil with untrained shear strength ranging from $15\sim50\;kPa$. However, the efficiency of this method is falling down in the more compressible soil conditions, which does not provide sufficient lateral confinement. In the present study, the GCP method reinforced with uniformly graded permissible concrete is suggested for the extension of application to the soft ground. Also, large triaxial compression tests are conducted on composite- reinforced soil samples for verification of availability of the suggested method and the settlement estimation method of the reinforced GCP is proposed. Further, for the verification of a validity of the proposed method, predicted settlements are compared with results of numerical analyses. Tn addition, parametric studies are performed together with detailed analyses of relevant design parameters.

  • PDF

양식산 무지개송어에서의 항생제와 말라카이트 그린 잔류량 조사 (The Residues of Antibiotics (Tetracycline, Oxolinic Acid and Ciplofloxacin) and Malachite Green in Cultured Rainbow Trout)

  • 김영목;이명숙;정용현
    • 수산해양교육연구
    • /
    • 제25권4호
    • /
    • pp.828-835
    • /
    • 2013
  • Products from aquaculture have sometimes been focused on the problems caused by the contamination of chemical agents as the use of chemical agents in aquaculture has been annually increased. The risk of contamination of products by chemical agents is greater in freshwater than in seawater. In order to evaluate the food safety of a fish grown in freshwater, we investigated the residues of antibiotics (tetracycline, oxolinic acid and ciplofloxacin) and malachite green in cultured rainbow trout, Oncorhynchus mykiss. Malachite green, which was prohibited in the application of aquaculture, was not detected in samples tested in this study. The residual content of tetracycline was determined to be less than the permissible amount, <0.2 mg/kg. The contents of ciplofloxacin was also less than the permissible amount, <0.1 mg/kg. However, in case of oxolinic acid, one of samples was only exhibited higher content than the permissible amount (<0.1 mg/kg). The results obtained in this study suggested that the control and regulation of chemical agents such as antibiotics was important to maintain a safe and worry-free seafood supply.

22.9kV CN/CV 전력 케이블의 상시 허용전류에 관한 연구 (A study on the continuous permissible current rating in 22.9kV CN/CV underground distribution power cables)

  • 김정배;김정태;구자윤;선종호;류희석;조연옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 하계학술대회 논문집
    • /
    • pp.304-307
    • /
    • 1990
  • Referring to the calculation of the continuous permissible current rating in 22.9kV CN/CV underground distribution power cables, the current and temperature have been fully discussed and analyzed based on their three different values: one is the actually measured value throughout our test and the other two are calculated in connection with different specifications IEC-287 and JCS-168-D respectively. For this purpose, our test has been carried out with real cables which have been under stress either with induced current or with rating voltage. In the former, the calculated current of IEC-287 shows closer value to the measured one than that of JCS-168-D does. In the latter, there has been little difference on the temperature comparing with that measured without voltage application. Therefore, we think that it is preferable to choose the IEC-287 specification for the calculation of the continuous permissible current rating in the commercially power cables.

  • PDF

154kV XLPE 600㎟ 지중관로 수평배열 형태별 허용전류용량 산정에 관한 연구 (A Study on the Calculation of Transmission Current-Carrying Capacity by Horizontal Arrangement Type in the Installation Methods of 154kV XLPE 600㎟ Power Cable Buried Ducts in Ground)

  • 김세동;유상봉
    • 조명전기설비학회논문지
    • /
    • 제30권3호
    • /
    • pp.53-58
    • /
    • 2016
  • The underground transmission lines which have been built to expand the suppling facilities will be continuously accompanying with high growth of the increase of power demand in the metropolitan area in recent years. So, it is necessary to maximize the ability and reliability of power supply with the current-carrying capability of the underground transmission lines. Design criteria of KEPCO is to be presented and used frequently. But it has to be studied about the installation methods of power cable buried in ground. In this study, we used the program for calculating the current-carrying capability of underground transmission power cables. We estimated the maximum permissible current values by the horizontal arrangement in the installation methods of power cable(154kV XLPE $600mm^2$) buried ducts in ground. To see the general tendency of the analysis, we researched a statistical analysis with such parameters as the maximum permissible current values. Through the regression analysis, we analyze the most highly values of the maximum permissible current on the Ra type duct arrangement.