• Title/Summary/Keyword: permissible

Search Result 689, Processing Time 0.028 seconds

A Probabilistic Order Level System When Delay in Payment Is Permissible

  • Shah, Mita H.
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.18 no.2
    • /
    • pp.175-182
    • /
    • 1993
  • The probabilistic order level inventory model is developed when a supplier allows some credit period T for settling the accounts for purchase quantity. The credit period T is known constant. Mathematical models are derived for both the cases i) T'.leq. T and ii) T'>T. Expressions are derived for average expected total cost of the system, the optimum cycle time and for obtaining optimum order level S = S$_{0}$ in each case. The exmaples are given to illustrate the model.

  • PDF

A Study on the Improvement of Depreciation Management for Construction Equipment Considering Economic Efficiency (경제성에 의한 건설중장비 감가상각관리 개선)

  • Lee, Yongsu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.4D
    • /
    • pp.357-366
    • /
    • 2012
  • Construction equipment has applied to depreciation over the years, however, the price index for construction equipment is not properly reflected in existing quantity per unit and the local tax law. Thus, this study shows the analysis of the corporate tax law, the local tax law and business accounting standards, characteristics of the domestic depreciation system and depreciation methods, and the capital recovery factor of construction equipment applying the theory for economic efficiency. It also presents cases of depreciation on the basis of quantity per unit and tax law using straight-line depreciation method and declining balance method. It is proposed that the relations of the application system of permissible period for construction equipment and the existing system be explained and the application system of permissible period for construction equipment be imposed. Furthermore, it proposes the development of depreciation tables of construction equipment monthly expenses based on the domestic price index and applications. In addition of that, it proposes the analysis of pros and cons of the methods suggested and application limits of the study and subsequent improvement plans. This study should reflect more rational and objective reality in quantity per unit and tax law.

Simulated tropical cyclonic winds for low cycle fatigue loading of steel roofing

  • Henderson, David J.;Ginger, John D.;Morrison, Murray J.;Kopp, Gregory A.
    • Wind and Structures
    • /
    • v.12 no.4
    • /
    • pp.383-400
    • /
    • 2009
  • Low rise building roofs can be subjected to large fluctuating pressures during a tropical cyclone resulting in fatigue failure of cladding. Following the damage to housing in Tropical Cyclone Tracy in Darwin, Australia, the Darwin Area Building Manual (DABM) cyclic loading test criteria, that loaded the cladding for 10000 cycles oscillating from zero to a permissible stress design pressure, and the Experimental Building Station TR440 test of 10200 load cycles which increased in steps to the permissible stress design pressure, were developed for assessing building elements susceptible to low cycle fatigue failure. Recently the 'Low-High-Low' (L-H-L) cyclic test for metal roofing was introduced into the Building Code of Australia (2007). Following advances in wind tunnel data acquisition and full-scale wind loading simulators, this paper presents a comparison of wind-induced cladding damage, from a "design" cyclone proposed by Jancauskas, et al. (1994), with current test criteria developed by Mahendran (1995). Wind tunnel data were used to generate the external and net pressure time histories on the roof of a low-rise building during the passage of the "design" cyclone. The peak pressures generated at the windward roof corner for a tributary area representative of a cladding fastener are underestimated by the Australian/New Zealand Wind Actions Standard. The "design" cyclone, with increasing and decreasing wind speeds combined with changes in wind direction, generated increasing then decreasing pressures in a manner similar to that specified in the L-H-L test. However, the L-H-L test underestimated the magnitude and number of large load cycles, but overestimated the number of cycles in the mid ranges. Cladding elements subjected to the L-H-L test showed greater fatigue damage than when experiencing a five hour "design" cyclone containing higher peak pressures. It is evident that the increased fatigue damage was due to the L-H-L test having a large number of load cycles cycling from zero load (R=0) in contrast to that produced during the cyclone.

Management Changes of Hazardous Air Pollutants Sources and Its Proposed Improvement in Korea (유해대기오염물질 배출원 관리의 변천과 개선방향)

  • Kim, Jong-Ho;Lee, Jeong Joo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.29 no.5
    • /
    • pp.536-544
    • /
    • 2013
  • Even a small amount of hazardous air pollutants could have a harmful influence upon human beings, animals and plants. Hazardous air pollutants have the properties of toxicity, canceration and organism accumulation. They include heavy metals, volatile organic compounds, polycyclic aromatic hydrocarbons, dioxin, etc. The Clean Air Conservation Act has defined specific hazardous air pollutants and designated 35 pollutants, distinguishing them from common air pollutants for special control. This study investigates the history of the controls of specific hazardous air pollutants with reference to some relevant laws and regulations in Korea. It investigates the regulations at the permission stage, such as the restrictions on installation of emission facilities, the permission and reporting of installation of emission facilities, and the regulations at the operation stage, such as maintaining permissible emission levels, installation of measuring devices, dues for emission, self-measurement and securing environmental engineers. The current regulatory management is not so satisfactory in regards to the serious effects of specific hazardous air pollutants upon the human body. An advanced new concept, like the maximum available control technology in US, the facilities management standards, which will soon take effect, will be able to lessen the emissions of fugitive hazardous air pollutants. In addition, this study discusses some possible stricter controls on the emission facilities of specific hazardous air pollutants and proposes some measures to maintain and supplement the current systems.

A study on the status of working environment control and health management of workers in a manufacturing industries (일부 제조업 사업장의 작업환경 및 보건관리 실태)

  • Ham, Jung-O;Hwang, Kyu-Yoon;Ahn, Kyu-Dong;Lee, Byung-Kook;Nam, Tack-Sung
    • Journal of Preventive Medicine and Public Health
    • /
    • v.23 no.3 s.31
    • /
    • pp.275-284
    • /
    • 1990
  • To obtain the useful information for the status of working environment and health management of workers in manufacturing industries, comparision of results on the status of working environmental and health management of workers for 32 manufacturing industries in Chunan area from 1988 to 1989 was carried out. The results were as follows : 1. The rate of over-PEL (Permissible Exposure Limit) to for hazardous factors decreased significantly 23.5% in 1988, 18.3% in 1989 (p<0.05) and, the highest rate of over-PEL was the stone and sand handling industry, the highest rate of over-PEL was the dusty workplace as 38.5% in 1988, 35.2% in 1989. 2. The rate of workers exposed to hazardous factors in 1988 and in 1989 was 22.4% respectively, the rate of workers checked up special health examination was 40.1% in 1988, 75.3% in 1989. In stone and sand handling and medicochemical industries, none of workers exposed to hazardous factors was subjected to special health examination in 1988, but 75% of workers exposed to hazardous factors had checked up in 1989. 3. The 6 industries appointed as part-time factory physician among 17 industries which were supposed to have factory physician according to the Safety and Healthy Act of Korea, 6 out of 24 industries only appointed industrial hygienist, furthermore 4 out of 6 hygienists had another duty in addition to occupational hygiene itself.

  • PDF

Recycling of the Bottom Ash, Sourced from the Local MSW (Municipal Solid Waste) Incinerators, as a Fine Sand for Concrete (소각장(燒却場)에서 발생되는 바닥재의 콘크리트용 잔골재(骨材)로서의 재활용(再活用))

  • Lim, Nam-Woong
    • Resources Recycling
    • /
    • v.16 no.2 s.76
    • /
    • pp.40-47
    • /
    • 2007
  • This paper described recycling of the bottom ash, sourced from the local incinerators as a fine sand for concrete. 10% bottom ash was substituted for the ordinary beach sand in the mortar(on a weigh basis), in conjunction with the pozzolznic diatomite. The specimens were tested according to KS L 5105 and analysed by TCLP(Toxic Chemical Leaching Procedure). The results showed that the hazardous heavy metals in the bottom ash are within the maximum permissible limit of TCLP. The compressive strength of the mortar with 10% bottom ash was highly improved, compared to the control mortar when the pozzolanic diatomite was used. It revealed that the hazardous heavy metals of the mortar with 10% bottom ash were leached within the maximum permissible limit of TCLP. It was concluded that the bottom ash can be reused as a fine sand for concrete when the pozzolanic diatomite was used as a stabilizer.

Analysis on the Risk-Based Screening Levels Determined by Various Risk Assessment Tools (III): Proposed Methodology for Lead Risk Assessment in Korea (다양한 위해성평가 방법에 따라 도출한 토양오염 판정기준의 차이에 관한 연구(III): 우리나라 납 오염 위해성평가 방법 제안)

  • Jung, Jae-Woong;Nam, Kyoungphile
    • Journal of Soil and Groundwater Environment
    • /
    • v.20 no.6
    • /
    • pp.1-7
    • /
    • 2015
  • The most critical health effect of lead exposure is the neurodevelopmental effect to children caused by the increased blood lead level. Therefore, the endpoint of the risk assessment for lead-contaminated sites should be set at the blood lead level of children. In foreign countries, the risk assessment for lead-contaminated sites is conducted by estimating the increased blood lead level of children via oral intake and/or inhalation (United States Environmental Protection Agency, USEPA), or by comparing the estimated oral dose to the threshold oral dose of lead, which is derived from the permissible blood lead level of children (Dutch National Institute for Public Health and the Environment, RIVM). For the risk assessment, USEPA employs Integrated-Exposure-Uptake-Biokinetic (IEUBK) Model to check whether the estimated portion of children whose blood lead level exceeds 10 µg/dL, threshold blood lead level determined by USEPA, is higher than 5%, while Dutch RIVM compares the estimated oral dose of lead to the threshold oral dose (2.8 µg/kg-day), which is derived from the permissible blood lead level of children. In Korea, like The Netherlands, risk assessment for lead-contaminated sites is conducted by comparing the estimated oral dose to the threshold oral dose; however, because the threshold oral dose listed in Korean risk assessment guidance is an unidentified value, it is recommended to revise the existing threshold oral dose described in Korean risk assessment guidance. And, if significant lead exposure via inhalation is suspected, it is useful to employ IEUBK Model to derive the risk posed via multimedia exposure (i.e., both oral ingestion and inhalation).

Tolerance Analysis on 3-D Object Modeling Errors in Model-Based Camera Tracking (모델 기반 카메라 추적에서 3차원 객체 모델링의 허용 오차 범위 분석)

  • Rhee, Eun Joo;Seo, Byung-Kuk;Park, Jong-Il
    • Journal of Broadcast Engineering
    • /
    • v.18 no.1
    • /
    • pp.1-9
    • /
    • 2013
  • Accuracy of the 3-D model is essential in model-based camera tracking. However, 3-D object modeling requires dedicated and complicated procedures for precise modeling without any errors. Even if a 3-D model contains a certain level of errors, on the other hand, the tracking errors cause by the modeling errors can be different from its perceptual errors; thus, it is an important aspect that the camera tracking can be successful without precise 3-D modeling if the modeling errors are within the user's permissible range. In this paper, we analyze the tolerance of 3-D object modeling errors by comparing computational matching errors with perceptual matching errors through user evaluations, and also discuss permissible ranges of 3-D object modeling errors.

The Characteristics of Dispersed Asbestos Fibers Produced From Building Materials (건축재료에서 발생되는 석면입자의 특성 연구)

  • 유성환
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.9 no.3
    • /
    • pp.191-199
    • /
    • 1993
  • This paper describes the results of a systematic study to determine the characteristics of particle generated from various types of asbestos containing material(ACM) and manmade fiber material(MMFM) during operations of cutting and grinding in laboratory and workplace. Tests were conducted with a specially designed glove box which allowed complete sampling of the generated asbestos fibers. Specificially, air measurements were made during ACM and MMFM installation in building. All personal air samples collected were identified by polarized light microscopy(PLM), X-ray diffraction(XRD) and scanning electron microscope with energy dispersive X-ray analysis(SEM/EDXA). Also, the samples were counted by phase contrast microscope(PCM) in order to compare the results with the permissible exposure standard for workplace. Results indicate that the characterisitcs of fibers found in the roofing sheet, the ceiling and the wall insulation boards were identical to those of asbestos, while the characteristics of fibers found in the ceiling insulation board, the floor tile and the sprayed on insulation products in parking area were identical to those of asbestos, while the characteristics of fibers found in the ceiling insulation board, the floor tile and the sprayed on insulation products in parking area were identical to those of rock wool. The concentrations of airborne fibers from various building materials cut by a grinder for 5 minutes were in the ranges of 0.09 $\sim$ 1.71 fibers/cc(f/cc). The highest concentration(1.71f/cc) was found during grinding the wall insulation board which also contains rock wool. The airborne fiber concentrations generated by installing at workplace were ranged from 0.0009 to 0.029 f/cc. All asbestos fibers from the ceiling insulation board at workplace were less than 20$\mu$m in length and more than 20% of them had the average aspect ratio greater than 20. Therefore, for the purpose of decreasing asbestos and man-made fiber concentrations at the workplace, the ceiling and wall board should use strong binding material to increase the binding force with fiber. Also, the permissible exposure standard for workplace(2.0f/cc) in Korea should be constituted below the maximum avaiable concentration measured at glove box.

  • PDF

A Study on the Evaluation of the Boarding Environment for the Ship Vibration (on the Basis of ISO-6954 : 2000(E)) (선박의 선내 진동에 의한 승선 환경 평가에 관한 연구 (ISO-6954 : 2000(E)의 평가방법에 기초))

  • Yu, Young-Hun
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.13 no.4
    • /
    • pp.107-112
    • /
    • 2007
  • The vibration generated on shipboard is very important because it greatly affects on the comfortable mind of passenger and working conditions of crews. Shipboard vibration is closely concerned with the development of propulsion method and the type of main engine to decide speed of ship. To make the propulsion power, the main engine of ship have continuous explosion process in engine room, so the shipboard vibration is generated. The shipboard vibration causes the physiological and psychological damages to human body. In the case of the human body exposed to the shipboard vibration, the evaluation of human exposure to whole-body vibration is prescribed in ISO 6954 : 2000(E). In this paper, to evaluate the shipboard working environment, two kinds of vibration levels onboard ship were measured and compared with one another between engine rooms, engine control rooms and wheel house by the regulation of ISO 6954 : 2000(E).

  • PDF