• 제목/요약/키워드: period of vibration

검색결과 449건 처리시간 0.026초

발전용 가스터빈 Rotor 정지조건별 최적 Turning 운전시간 고찰: 501기종 현장실험 중심으로 (A Study on Optimal Turning Operation Time for Rotor Stop Condition in Gas Turbine: Based on Field Test of W501 Machines)

  • 유원주;이창열
    • 대한안전경영과학회지
    • /
    • 제25권3호
    • /
    • pp.1-7
    • /
    • 2023
  • As the capacity of renewable power generation facilities rapidly increases, the variability of electric power system and gas turbine power generation is also increasing. Therefore, problems may occur that require urgent repair while the gas turbine rotor is stopped. When the gas turbine rotor turning is stopped and then restarted, if the turning period is not appropriate, severe vibration may occur due to rotor bending. As a result of the experiment, it was confirmed that normal operation is possible when the gap data measured at the start of rotor turning after maintenance work is similar to the existing value. And the vibration value at the start of rotor turning was lower as the rotor temperature was lower or the stop period was shorter.

원심모형실험을 활용한 얕은 기초가 있는 다자유도 구조물의 지진응답 (Seismic Responses of Multi-DOF Structures with Shallow Foundation Using Centrifuge Test)

  • 김동관;김호수;김진우
    • 한국지진공학회논문집
    • /
    • 제26권3호
    • /
    • pp.117-125
    • /
    • 2022
  • In this study, centrifuge model tests were performed to evaluate the seismic response of multi-DOF structures with shallow foundations. Also, elastic time history analysis on the fixed-base model was performed and compared with the experimental results. As a result of the centrifuge model test, earthquake amplification at the fundamental vibration frequency of the soil (= 2.44 Hz) affected the third vibration mode frequency (= 2.50 Hz) of the long-period structure and the first vibration mode (= 2.27 Hz) of the short-period structure. The shallow foundation lengthened the periods of the structures by 14-20% compared to the fixed base condition. The response spectrum of acceleration measured at the shallow foundation was smaller than that of free-field motion due to the foundation damping effect. The ultimate moment capacity of the soil-foundation system limited the dynamic responses of the multi-DOF structures. Therefore, the considerations on period lengthening, foundation damping, and ultimate moment capacity of the soil-foundation system might improve the seismic design of the multi-DOF building structures.

Soil interaction effects on the performance of compliant liquid column damper for seismic vibration control of short period structures

  • Ghosh, Ratan Kumar;Ghosh, Aparna Dey
    • Structural Engineering and Mechanics
    • /
    • 제28권1호
    • /
    • pp.89-105
    • /
    • 2008
  • The paper presents a study on the effects of soil-structure-interaction (SSI) on the performance of the compliant liquid column damper (CLCD) for the seismic vibration control of short period structures. The frequency-domain formulation for the input-output relation of a flexible-base structure with CLCD has been derived. The superstructure has been modeled as a linear, single degreeof-freedom (SDOF) system. The foundation has been considered to be attached to the underlying soil medium through linear springs and viscous dashpots, the properties of which have been represented by complex valued impedance functions. By using a standard equivalent linearization technique, the nonlinear orifice damping of the CLCD has been replaced by equivalent linear viscous damping. A numerical stochastic study has been carried out to study the functioning of the CLCD for varying degrees of SSI. Comparison of the damper performance when it is tuned to the fixed-base structural frequency and when tuned to the flexible-base structural frequency has been made. The effects of SSI on the optimal value of the orifice damping coefficient of the damper has also been studied. A more convenient approach for designing the damper while considering SSI, by using an established model of a replacement oscillator for the structure-soil system has also been presented. Finally, a simulation study, using a recorded accelerogram, has been carried out on the CLCD performance for the flexible-base structure.

초고층 건물의 풍가속도응답 조절 기법 (Control Method of Wind Induced Vibration Level for High-rise buildings)

  • 김지은;서지현;박효선
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.375-382
    • /
    • 2005
  • In this paper, a practical control method of wind-induced vibration of high-rise buildings is presented in the form of resizing algorithm. In the structural design process for high-rise buildings, the lateral load resisting system for the building is more often determined by serviceability design criteria including wind-induced vibration level. Even though many drift method have been developed in various forms, no practical design method for wind induced vibration has been developed so far. Structural engineers rely upon heuristic or experience in designing wind induced vibration. The performance of the proposed method is evaluated by comparing wind-induced vibration levels estimated both from approximate techniques and wind tunnel test.

  • PDF

파라미터 해석을 통한 차량 성능 예측 기법 연구 (Study on the Prediction Technique of Vehicle Performance Using Parameter Analysis)

  • 김기창;김찬묵;김진택
    • 한국소음진동공학회논문집
    • /
    • 제20권11호
    • /
    • pp.995-1000
    • /
    • 2010
  • With the development of the auto industry, the automobile manufacturers demand to shorten development period and reduce the cost. Compared with the traditional method, applying the virtual prototype is more economical. This paper presents a method for parameters sensitivity analysis and optimizing the performance of vehicle noise and vibration. The existing design processes were repeatedly analyzed with a focus on vehicle performance to decide the design parameters of dimension, thickness, mounting type of body and chassis systems in the vehicle development period. This paper describes the prediction technique of vehicle performance using L18 orthogonal array layout, quality deviation analysis and parameter sensitivity analysis for robust design. This paper analyzed the performance correlation equation through the frequency and sensitivity database according to a design factor change. The new concept is that the performance prediction is possible without repeated activities of test and analysis. This paper described the parameter analysis applications such as bush dynamic stiffness and bush void direction of rear suspension. Design engineer could efficiently decide the design variable using parameter analysis database in early design stage. These improvements can reduce man hour and test development period as well as to achieve stable NVH performance.

일부지역 탄광 착암 근로자의 진동증후군 유병율 (Prevalence of the Vibration Syndrome among Rock-drillers in the Anthracite Mining Area)

  • 노재훈
    • Journal of Preventive Medicine and Public Health
    • /
    • 제14권1호
    • /
    • pp.75-80
    • /
    • 1981
  • Due to rapid industrialization and economic development, the occupational diseases have appeared as one of the social problems in Korea. Up until now little has been known about the prevalence rate, predisposing factors and symptomatology of the occupational disease due to localized vibration in Korea. The researcher intends to investigate the prevalence rate and affecting factors of the occupational disease due to localized vibration among rock-drillers in the anthracite mines. A total of 135 rock-drillers were interviewed and examined from May 15th to 31th, 1980. The results were revealed as follows; 1. The prevalence rate of the vibration syndrome among rock-drillers was 12.6%. 2. The latent period of the vibration syndrome was 6.8 years. 3. The prevalence rate of the vibration syndrome was not significantly different between smokers and non-smokers. 4. With the increase of total vibration exposure time, the prevalence rate of the vibration syndrome increased also. 5. The average vibration sensation threshold was high (6.4dB) in stage 1 of the vibration syndrome and low (-0.6dB) in stage 0. 6. The average pain sensation threshold was high (4.4g) in stage 1 of the vibration syndrome and low (2.5g) in stage 0.

  • PDF

2단계 소호전압방식을 적용한 보상권선형 SRM의 진동.소음특성 (Vibration and Acoustic Noise characteristic on SRM with compensating winding by two stage commutation)

  • 오석규;이종근;최태완
    • 전력전자학회논문지
    • /
    • 제6권3호
    • /
    • pp.250-257
    • /
    • 2001
  • SRM 드라이브는 펄스 기자력과 스위칭 전류원리상 큰 소음과 진동이 발생된다. SRM 드라이브에서 발생하는 진동.소음의 주된 원인은 상 스위치-오프시의 고정자와 회전자 사이에 자기적인 스트레스로 작용하는 바사방향의 급격한 전자력 변화에 의한 고정자 프레임의 탄성진동에 의해 발생한다. 본 논문에서는 이러한 SRM 드라이브의 진동을 저감하는 방법으로 기존의 SRM에 상권선과 동일한 자속이 발생하도록 단방향 보상권선(Compensating Winding)을 감아 컴뮤테이션 기간동안 2단계 소호전압방식을 적용하는 방법을 제안하고자 한다. 2단계 소호전압방식을 적용함으로서 상전류를 빨리 소호시킬 수 있고 이로 인해 토크 활용구간과 에너지 활용도를 넓힐 수 있어서 큰 출력을 발생시킬 수 있었으며, 진동.소음저감효과를 얻울 수 있었다

  • PDF

성덕대왕신종의 등가 종과 맥놀이 주기 조절 (An Equivalent Bell and Beat Period Control in the Sacred Bell of the Great King Seongdeok)

  • 이중혁,;김석현
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2013년도 춘계학술대회 논문집
    • /
    • pp.472-475
    • /
    • 2013
  • This study proposes an equivalent bell model for the Sacred Bell of the Great King Seongdeok An equivalent bell model bas the modal property of the real bell and it consists of an axi-symmetric bell body and a point mass, The bell model is constructed by the finite element analysis based upon the theory of a revolutionary shell. Using the equivalent bell model. the beat period can be controlled by decreasing the thickness of local area. This study aims at showing a beat period control method for a large bell having the similar size to the Sacred Bell of the Great King Seongdeok.

  • PDF

기존 RC 아파트 바닥의 수직진동 성능 평가 (Evaluation of Floor Vibration Existing in Apartment Building)

  • 이민정;한상환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.329-334
    • /
    • 2002
  • In recent years building floors become larger and more spacious due to the development of new design methods and high strength and light weight materials, However, such long span floor systems may provide smaller amount of damping and have longer period so that they would be more vulnerable to the floor vibration. This study attempts to evaluate the performance of the floors in typical apartment buildings. Three different floors with the area of $43.2m^2 41.44m^2 and 34.5m^2$, were investigated. The guideline provided by AISC(1997) is used to check the acceptability of the floor vibration.

  • PDF

마이크로중력 과학 임무 수행용 초소형 위성의 진동 해석 (Vibration Analysis of a Nanosatellite for Microgravity Science Missions)

  • 김진혁;장정익;박설현
    • 한국기계가공학회지
    • /
    • 제18권12호
    • /
    • pp.104-110
    • /
    • 2019
  • A nanosatellite designed by the Korea Microgravity Science Laboratory (KMSL) is currently under development. The KMSL nanosatellite is designed to perform two different scientific missions in space. To successfully complete missions, a variety of tests must be conducted to verify the performance of the designed satellite before launch. As part of the qualification test campaign, the KMSL nanosatellite underwent high level vibrational tests (to comply with Falcon 9 qualification level) to demonstrate the integrity of the system. The purpose of this study is to demonstrate that the primary structure and all electronic and mechanical components can withstand the vibrations and the loads experienced during the launch period. To this end, the KMSL nanosatellite was exposed to static and dynamic loads and various types of vibrations that are inevitably produced during the space vehicle launch period. The vibration test results clearly demonstrated that all avionics and mechanical components can withstand the vibrations and the loads applied to the KMSL nanosatellite's body through a Pico-satellite Orbital Deployer (POD).