• Title/Summary/Keyword: performance tests and methods

Search Result 1,096, Processing Time 0.027 seconds

A Study on the Surface Air-Void Reduction of High Performance Concrete (고성능 콘크리트의 표면기포 저감에 관한 연구)

  • Park, Sang-Joon
    • Journal of the Korea Institute of Building Construction
    • /
    • v.9 no.1
    • /
    • pp.49-55
    • /
    • 2009
  • In this study, reduction methods of surface air void were examined for high performance concrete having high viscosity. The effects of assumed influencing factors such as form types, form-coating materials, tamping equipments and methods were examined based on the tests on mock-up specimens made of high performance concrete. The test results can be summarized as follows: As for form types, the most favorable results were obtained when coated plywood form was used with panel-shape tamping equipments at the contact region with concrete, the second and the third being the water/air-permeable sheets and steel with coated plywood, respectively. As for tamping equipments, a vibrator with 6.5cm diameter was most effective. Finally, the shorter the tamping intervals, the better the reduction effect of surface air void. As a conclusion, an improved method was proposed to reduce surface air void and it was verified with the test result that only four air voids as large as $5{\sim}10mm$ are found in the are of $1m^2$.

Laboratory Performance Evaluation of Alternative Dowel Bar for Jointed Concrete Pavements (콘크리트 포장용 고내구성 대체 다웰바의 실내공용성 평가)

  • Park, Seong Tae;Park, Jun Young;Lee, Jae Hoon;Kim, Hyung Bae
    • International Journal of Highway Engineering
    • /
    • v.15 no.1
    • /
    • pp.23-36
    • /
    • 2013
  • PURPOSES: The problem under this circumstance is that the erosion not only drops strength of the steel dowel bar but also comes with volume expansion of the steel dowel bar which can reduce load transferring efficiency of the steel dowel bar. To avoid this erosion problem, alternative dowers bars are developed. METHODS: In this study, the bearing stresses between the FRP tube dowel bar and concrete slab are calculated and compared with its allowable bearing stress to check its structural stability in the concrete pavement. These comparisons are conducted with several cross-sections of FRP tube dowel bars. Comprehensive laboratory tests including the shear load-deflection test on a full-scale specimen and the full-scale accelerated joint concrete pavement test are conducted and the results were compared with those from the steel dowel bar. RESULTS: In all cross-sections of FRP tube dowel bars, computed bearing stresses between the FRP tube dowel bar and concrete slab are less than their allowable stress levels. The pultrusion FRP-tube dowel bar show better performance on direct shear tests on full-scale specimen and static compression tests at full-scale concrete pavement joints than prepreg and filament-winding FRP-tube dowel bar. CONCLUSIONS: The FRP tube dowel bars as alternative dowel bar are invulnerable to erosion that may be caused by moisture from masonry joint or bottom of the pavement system. Also, the pultrusion FRP-tube dowel bar performed very well on the laboratory evaluation.

Seismic Performance Evaluation of the Ceiling Bracket-type Modular System with Various Bracket Lengths and Bolt Types (천장 브래킷형 모듈러 시스템의 브래킷 길이와 볼트에 따른 내진성능평가)

  • Kwak, Eui-Shin;Kang, Chang-Hoon;Shon, Su-Deok;Lee, Seung-Jae
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.4
    • /
    • pp.25-33
    • /
    • 2018
  • In regard to modular systems, new methods, as well as middle and high-story unit design ideas, are currently being studied. These studies need to focus on the enhanced stiffness and seismic performance of these connections, and see that the development of fully restrained moment connections can improve the seismic performance. For this reason, this study evaluates the performance of the connections of the ceiling bracket-typed modular system through repeated loading tests and analyses. In order to compare them with these modular units, new unit specimens with the bracket connection being different from that of the traditional modular unit specimens were designed, and the results of repeated loading tests were analyzed. In the traditional units, the structural performances of both welding connection and bolt connection were evaluated. In regard to the testing results, the initial stiffness of the hysteresis curve was compared with the theoretical initial stiffness, and the features of all specimens were also analyzed with regard to the maximum moment. In addition, the test results were examined with regard to the connection flexural strength of the steel special moment frame specified under the construction criteria KBC2016. The connections, which were proposed in the test results, were found to be fully restrained moment connections for designing strong column-weak beams and meeting the requirements of seismic performance of special moment frames.

Performance Evaluation System for Tow-Channel Ring-Core Flux-Gate Compass (2-체널 링-코어 프럭스-게이트 콤파스의 성능평가 시스템 개발)

  • 임정빈;김봉석
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2002.11a
    • /
    • pp.13-19
    • /
    • 2002
  • Design and implementation methodologies on the performance evaluation system of two-channel ring-core Flux-Gate Compass (FG-Compass) are described, with evaluation procedures and methods based on the polynomial regression models. Performance evaluation system is consists of a step motor driving unit, a bearing transmitting unit and, evaluation programs using polynomial regression formulae. Through performance evaluation tests, total residual deviation tests, total residual deviation of $\pm$4$^{\circ}$ and eigen residual deviation of $\pm$2$^{\circ}$ are obtained from the FG-Compass. The result is more accurate values than the typical FG-Compass with eigen residual deviation of $\pm$4$^{\circ}$ and is provide a possibility to develop a high performance FG-Compass. In addition, the design methodology of a smart FG-Compass with the self estimation and correction of residual deviations is also discussed.

  • PDF

A Study on the Improvement of Sampling Rate of Performance Test in Public Survey (공공측량 성과심사에서 심사비율 개선을 위한 연구)

  • Kim, Kyu-Seong;Lee, Young-Min;Jung, Byung-Chul;Choi, Yoon-Soo
    • Communications for Statistical Applications and Methods
    • /
    • v.17 no.6
    • /
    • pp.853-863
    • /
    • 2010
  • The performance test in a public survey is conducted by a sample survey and the sampling rate of the performance test is a very important factor in the test process. Since the current sampling rate was decided empirically at an earlier time, it has been criticized for two points: the first is that it has a lack of a theoretical background on the decision for the sampling rate and the second is that the sampling rate should be improved in accordance with current test situations. In this paper, we review the present state of performance tests in public surveys in Korea and study the relationship between the rate of the performance test and fitness probability, number of tests, and the success rate in order to create a theoretical background to improve the test rate. In addition, we discuss relationship between the test rate and cost in the performance test.

Clinical Usefulness of Point-of-care Test Chemistry Analyzer in Neonatal Intensive Care Unit

  • Jang, Yeong-Uk;Kim, Su-Nam;Cho, Hye-Jung;Sun, Yong-Han;Shim, So-Yeon;Son, Dong-Woo;Park, Pil-Whan
    • Neonatal Medicine
    • /
    • v.18 no.2
    • /
    • pp.301-309
    • /
    • 2011
  • Purpose: Point-of-care tests (POCTs) have the potential to significantly influence management of neonates. The aim of this study was to assess the clinical usefulness of the POCT chemistry analyzer in a neonatal intensive care unit (NICU). Methods: Blood samples of neonates admitted to the NICU were tested using a POCT chemistry analyzer (Piccolo Xpress Chemistry Analyzer, Abaxis, Union City, CA, USA) and a central laboratory chemical analyzer (Chemistry analyzer 7600-110, Hitachi Ltd., Tokyo, Japan) from March to September, 2010. Correlation of 15 analytes between the POCT and the central laboratory machine was evaluated. For consistency of the POCT, three consecutive samplings were performed. Differences among the three tests were recorded. The causes of performance errors were checked through log files. Results: One hundred of 112 pairs of tests for accuracy performed in 54 neonates showed a high correlation between the two machines. Twelve performance errors occurred during the 112 tests. The most common error was insufficient sample error. Eighteen triplet tests performed in 18 patients for consistency revealed a difference range of 3-10%, which was considered to be acceptable. No error occurred during the 54 tests. Conclusion: The POCT is capable of analyzing multiple analytes with a minimal amount of whole blood in a short time. The few performance errors noted presently are likely preventable. This POCT is concluded to be suitable for use as a simple and rapid diagnostic method in the NICU with a minimal amount of blood collected in a less invasive manner.

Development of a Performance Appraisal Tool for Postoperative Anesthesia Care Unit Nurses (회복실간호사 업무수행평가 도구 개발)

  • Lee, Yoon Young
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.22 no.3
    • /
    • pp.270-278
    • /
    • 2016
  • Purpose: The purpose of this study was to develop a performance appraisal tool (PAT) for postoperative anesthesia care unit (PACU) nurses. Methods: This study was a descriptive, non-experimental methodological study. The PAT was developed through a literature review and tests for validity and reliability. Results: Subsequent to a review of the literature on nursing performance of PACU nurse, a 63 item questionnaire was developed. Through factor analysis, 61 items in 3 domains with 8 factors were derived. Cronbach's ${\alpha}$ coefficient of the final instrument was .99. Conclusion: This tool is an efficient PAT for PACU providing meaningful feedback for professional growth in PACU nurses.

Satellite Orbit Determination using the Particle Filter

  • Kim, Young-Rok;Park, Sang-Young
    • Bulletin of the Korean Space Science Society
    • /
    • 2011.04a
    • /
    • pp.25.4-25.4
    • /
    • 2011
  • Various estimation methods based on Kalman filter have been applied to the real-time satellite orbit determination. The most popular method is the Extended Kalman Filter (EKF) and the Unscented Kalman Filter (UKF). The EKF is easy to implement and to use on orbit determination problem. However, the linearization process of the EKF can cause unstable solutions if the problem has the inaccurate reference orbit, sparse or insufficient observations. In this case, the UKF can be a good alternative because it does not contain linearization process. However, because both methods are based on Gaussian assumption, performance of estimation can become worse when the distribution of state parameters and process/measurement noise are non-Gaussian. In nonlinear/non-Gaussian problems the particle filter which is based on sequential Monte Carlo methods can guarantee more exact estimation results. This study develops and tests the particle filter for satellite orbit determination. The particle filter can be more effective methods for satellite orbit determination in nonlinear/non-Gaussian environment.

  • PDF

Scheduling Methods for a Hybrid Flowshopwith Dynamic Order Arrival (주문 생산 방식을 따르는 혼합 흐름 공정에서의일정계획에 관한 연구)

  • Lee, Geun-Cheol
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.32 no.4
    • /
    • pp.373-381
    • /
    • 2006
  • This paper considers a scheduling problem for a hybrid flowshop with dynamic order arrival. A hybrid flowshop is an extended form of a flowshop, which has serial stages like a flowshop but there can be more than one machine at each stage. In this paper, we propose a new method for the problem of scheduling with the objective of minimizing mean tardiness of orders which arrive at the shop dynamically. The proposed method is based on the list scheduling approach, however we use a more sophisticated method to prioritize lots unlike dispatching rule-based methods. To evaluate the performance of the proposed method, a simulation model of a hybrid flowshop-type production system is constructed. We implement well-known dispatching rules and the proposed methods in the simulation model. From a series of simulation tests, we show that the proposed methods perform better than other methods.

Isomorphism, Human Resource Capability and Its Role in Performance Measurement and Accountability

  • WULANINGRUM, Puspita Dewi;AKBAR, Rusdi;SARI, Martdian Ratna
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.7 no.12
    • /
    • pp.1099-1110
    • /
    • 2020
  • This research tests the effects of institutional pressures, the use of performance measurement systems and accountability, and moderation effects of human resource capability between institutional pressures and the use of performance measurement systems in the Local Government institutions in Indonesia. The research aims to provide empirical evidence both quantitatively and qualitatively that isomorphism institutional pressures occurred in the scope of implementation of the performance measurement system and accountability in the public sector organizations and to show the importance of human resource capability enhancement in reducing external pressure impact. In addition, it tries to develop the correlation model of institutional pressures, human resource capability, implementation of the performance measurement system, and accountability of public sector organizations. The research used mixed methods with sequential explanatory design. The data collection used surveys and interviews in 209 regency/Special Region of Yogyakarta and Central Java local governments as samples. The research result indicated that the institutionalization process of the performance measurement is influenced by institutional pressures, especially coercive and mimetic pressures. Human resource capability was unable to weaken institutional pressures effects in the performance measurement system implementation. The research also proved that the use of a performance measurement system was able to improve local government institution accountability.