• Title/Summary/Keyword: performance test criteria

Search Result 706, Processing Time 0.029 seconds

A Study on the Standard Criteria of Solid Particle Separation Test for Marine Centrifugal Purifier (선박용 정유기 고형분 분리 성능시험 규격기준에 관한 연구)

  • Jeong, Sang-Hu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.8
    • /
    • pp.1028-1034
    • /
    • 2007
  • In order to establish a criteria of solid particle separation performance test on marine centrifugal purifier at factory acceptance test, an investigation had been done on criteria of test standards, regulations and test specifications of purifier manufactures. KS V 7836, fuel oil and lubricating oil purifiers for marine use-centrifugal type, the criteria of solid particle separation is studied in the point of reality, restricts and analysis method. It is proposed that a reasonable criteria and analysis method should be adopted, and the current criteria shall be revised to adequate levels considering reasonable basis and industrial technology levels. Also, the test analysis conceptions, separation efficiency method and particle size restriction method, are reviewed to fulfil separation performance test for marine centrifugal purifiers.

Results of Developing an ITS Device Performance Test-Bed and Criteria of Its Selection (ITS 장비 성능시험장 선정기준 및 구축결과)

  • Lee, Sang Hyup;Lee, Mi Young;Baik, Nam Cheol
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.5D
    • /
    • pp.703-708
    • /
    • 2006
  • In the United States and Japan ITS device performance test-beds have been widely developed to enhance the reliability of traffic information and to expedite the standardization of components for securing the compatibility of device. In this study the selection criteria for developing ITS device performance test-bed are investigated by analyzing the cases and studies of overseas. Based on the criteria, a test-bed is developed and test-run. The importance of developing ITS device performance test-bed was identified as the result of reviewing the test run of each selection.

Analysis of the Predictive Validity of College Entrance Criteria

  • Bae, Hyun-Wung
    • Journal of the Korean Data and Information Science Society
    • /
    • v.18 no.4
    • /
    • pp.973-983
    • /
    • 2007
  • Korea Military Academy has been using College Scholastic Ability Test(CSAT) and High School Grades(HSG) with other measures such as an Essay-type Test(ET), Physical Test(PT) and Personal Interview(PI) as criteria for entrance. The purpose of study is to investigate the properness of the criteria in admission decisions by examining the relationship between the college GPA and criteria, and the prediction of academic performance. The study showed that CSAT and HSG are significantly correlated with the college GPA, and these two criteria are better predictors for academic performance. Regression analysis also provided an important message that HSG is a better predictor than CSAT.

  • PDF

The Optimization Study on the Test Method of Remanufactured Power Steering Oil Pump by Using FMEA (FMEA를 활용한 재제조 파워스티어링 오일펌프 시험법에 대한 최적화 연구)

  • Seo, Youngkyo;Jung, Dohyun;Yu, Sangseok;Rha, Wanyong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.24 no.1
    • /
    • pp.90-98
    • /
    • 2016
  • Currently government certified test method for an automobile remanufactured products is insufficient. Thus many automotive parts in the remanufacturing market are lacking proper evaluation criteria and production of defective products are causing customer dissatisfaction. In this paper a power steering oil pump, which requires stringent manufacturing standards, is studied by the failure mode and effect analysis approach. The research suggested that the test criteria such as discharge flow characteristic test, tightness test, pulley run-out test, pressure switch operation test, low temperature test and rotation pressure durability test should be performed to evaluate the reliability of remanufactured power steering oil pumps. As a result of tests, the performance of remanufactured power steering oil pump satisfied the evaluation criteria of pressure switch operation test and low temperature test. However, the remanufactured power steering oil pump failed to satisfy the evaluation criteria on discharge performance test, tightness test and pulley run-out test. These performance evaluation tests proved the necessity of standard process for the remanufactured power steering oil pump.

A Study on Floor Slip Resistance Standard and Test Method for BF Certification (BF인증을 위한 바닥 마감재 미끄럼 성능기준 및 측정방법에 대한 연구)

  • Shin, Dong-Hong;Seong, Ki-Chang;Park, Kwang-Jae
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.25 no.3
    • /
    • pp.75-83
    • /
    • 2019
  • Purpose: There are no clear criteria for slip performance in the BF certification process, so the evaluator relies on subjective judgments depending on the field situation. Physical criteria for determining the slip performance of various floor finishes are not clear. C.S.R., the only criterion currently being used to check slip performance, may raise questions about its coverage, feasibility and reliability. Method: For an analysis of domestic standards and status, KS L 1001, KS M 3510, and KS F 2375. External standards are analyzed for ADA Standard, ANSI Standard, and BS EN Standard. Analyze the test methods and evaluation criteria of O-Y-PSM, BPT, and the dynamic slip resistance test used in these criteria. It also presents an improvement plan for the rational presentation of standards. Results: To date, various kinds of test methods and measuring devices of the slip resistance coefficient have been developed, but there are not many ways to trust useful results related to user safety. Reliability and thoroughly verified test methods and criteria should be used to assess the slip performance of the floor. In order to improve the standard for the evaluation of slip performance in Korea, the existing standard should first be raised to the same level as the overseas standard, and the application of the discriminatory standard should be applied considering the characteristics and usage patterns of each space. Implication: Currently, Korean standards propose various test methods, but the proper use of test methods, scope and assessment criteria are not established, so improvement of the comprehensive standard is necessary.

EVALUATION OF CAMERA PERFORMANCE USING ISO-BASED CRITERIA

  • Ko, Kyung-Woo;Park, Kee-Hyon;Ha, Yeong-Ho
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2009.01a
    • /
    • pp.76-79
    • /
    • 2009
  • This paper investigates the performance of a vehicular rear-view camera through quantifying the image quality based on several objective criteria from the ISO (International Organization for Standardization). In addition, various experimental environments are defined considering the conditions under which a rear-view camera may need to operate. The process for evaluating the performance of a rear-view camera is composed of five objective criteria: noise test, resolution test, OECF (opto-electronic conversion function) test, color characterization test, and pincushion and barrel distortion tests. The proposed image quality quantification method then expresses the results of each test as a single value, allowing easy evaluation. In experiments, the performance evaluation results are analyzed and compared with those for a regular digital camera.

  • PDF

Presentation of Performance Test Criteria for Denuclearization Verification Equipment Considering North Korea Environment (북한 환경을 고려한 비핵화 검증 장비의 성능 시험 기준 제시)

  • Ji-Young, Han;Su-Hui, Park;Yong-Min, Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.71-77
    • /
    • 2023
  • The issue of North Korea's denuclearization is an global issue that transcends the North and South. It is necessary to prepare for the denuclearization process in preparation for the situation in which North Korea reveals its intention to denuclearize. In the process of North Korea's denuclearization, it is required to guarantee the normal operation of the denuclearization verification equipment. If a performance test criteria that takes into account the North Korean environment is established, it is highly likely that it will be used in the future denuclearization process. For this purpose, basic materials related to performance test standards were established through analysis of test standards such as international standards. After that, we established a performance test criteria. This includes high temperature, low temperature, humidity, vibration and shock tests. Through follow-up studies, validity of test criteria will be established through actual device testing.

Analysis and Test of Vehicle Dynamics for '97-New Mugunghwa Coaches (97-신조 무궁화 객차의 차량동특성 해석 및 시험)

  • 양희주;김진태;김필환;이찬우
    • Proceedings of the KSR Conference
    • /
    • 1998.05a
    • /
    • pp.494-501
    • /
    • 1998
  • This Paper describes the evaluation methods and criteria used to verify running Performance of railway vehicle, and shows results of vehicle dynamics simulation and running performance tests for New Mugunghwa Coaches that were designed and manufactured by DHI in 1997. Through running performance test of New Mugunghwa Coaches, Vibration, Ride Comfort were measured on the condition of service operation. As a results, each simulation and test results meet the criteria proposed by Korean National Railroad(KNR) and Korea Railroad Research Institute(KRRI).

  • PDF

Identification of Supply Chain Management Performance Assessment Criteria for Textile and Apparel Enterprises in Distribution Science

  • Nhu-Mai Thi NONG;Duc-Son HA
    • Journal of Distribution Science
    • /
    • v.22 no.7
    • /
    • pp.73-82
    • /
    • 2024
  • Purpose: This study aims to identify the assessment criteria on textile and apparel supply chain management performance. Research design, data, and methodology: An integrated method of Delphi, quantitative survey, and ANP, in which Delphi with Kamet principle was applied to define the set of criteria, quantitative survey with reliability and validity test was utilized to ensure the match between the set of criteria and the whole textile and apparel industry, and ANP was used to derive weights of these criteria. Results: The set of supply chain management performance evaluation criteria composes of seven criteria namely order fulfillment quality, agility, costs, asset management, information sharing, innovation, and product development and 19 sub-criteria. Conclusions: This study theoretical contribution is the proposition of the set of evaluation criteria on supply chain performance. Regarding practical contribution, the study findings are guidelines for T&A companies in assessing and improving their supply chain capability. However, the findings are only for Vietnamese T&A context. Future research, therefore, may be expanded to other regions or countries' T&A industry. Additionally, future step to this study may be the utilization of other techniques of MCDM or methodological approaches like multiple regression, PLSSEM in defining weights of criteria or performance evaluation.

The Performance Improvement of Lightning Arrester Leakage Current Measuring Device for GIS (GIS용 피뢰기 누설전류 측정장치 성능개선)

  • Kim, Won-Gyu;Kim, Min-Soo;Baek, Young-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.12
    • /
    • pp.1726-1731
    • /
    • 2014
  • This paper shows the developed new lightning arrester LCM (Leakage Current Measuring device) which is important element of GIS (Gas Insulated Switchgear) Preventive & Diagnostic system and verify its performance though strengthened test standards. The existing lightning arrester LCM was modified to solve measuring errors which happened frequently. At first, we explained the principle of measuring leakage current. Through analyzing some problems which the existing LCM have. we got some improvable items. For the performance verification of the improved LCM, we manufactured prototype LCM which is applied some improvable items such as improving LCM circuit, adding protection circuit, optimizing inner structure of LCM and changing ground design. After then we carried out the performance test. Accredited testing laboratory carried out the performance verification test according to performance test criteria and procedure of reliability test standards, IEC-60225, 61000 and 60068 etc. We confirmed the test results which correspond with the performance test criteria. Also, we confirmed the performance of the improved LCM installed & being operated at G Substation through the immunity test against the normal noise and open/close surge etc.