• Title/Summary/Keyword: performance monitor

Search Result 1,152, Processing Time 0.029 seconds

Design of Integrity Monitor Functions for Maritime DGPS RSIM (해양용 DGPS 기준국의 무결성 감시 기능 설계)

  • Seo, Ki-Yeol;Park, Sang-Hyun;Cho, Deuk-Jae;Suh, Sang-Hyun
    • Journal of Navigation and Port Research
    • /
    • v.33 no.6
    • /
    • pp.395-400
    • /
    • 2009
  • In order to prepare for the DGNSS recapitalization and implementation of the functions for software based reference station and integrity monitor (RSIM) system, this paper proposes a design of integrity monitor functions of maritime differential GPS RSIM. The most critical functions of the integrity monitor (IM) are to generate and send flags to the reference station (RS) along with system feedback. Firstly, it presents the architecture of software based RSIM, and analyzes the performance standard of integrity monitor for maritime DGPS reference station This paper then designs the functions of integrity monitor for DGPS reference station based on the performance standard. Finally, this paper presents the results of performance analysis for the functionality of integrity monitor using the GNSS simulator. it discusses the study method and its application for the system implementation.

On-Line Assessment of High Voltage Motor Condition using the Motor Performance Monitor (MPM을 이용한 고압전동기 운전중 상태 평가)

  • Kim, Hee-Dong;Kong, Tae-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.9
    • /
    • pp.1589-1593
    • /
    • 2008
  • The condition of a high voltage motor was monitored with the motor performance monitor (MPM) at the motor control center. The MPM detected defects in the rotor bar and end ring and input power according to motor and load conditions. The assessment of the condition of a coal pulverizer motor indicated it was clearly in good condition in terms of the rotor bars, over voltage, and motor performance. However, the side bands at frequency, 56.48 Hz indicated existence of rotor end-ring fault. The large torque ripple indicated abnormal operating conditions. After visual inspection, it has been observed that an impeller blade of the circulating water pump was broken off causing the irregular torque pattern.

The Effect of Background Grey Levels on the Visual Perception of Displayed Image on CRT Monitor (CRT 모니터의 배경계조도가 영상의 시각인식에 미치는 영향)

  • 김종효;박광석
    • Journal of Biomedical Engineering Research
    • /
    • v.14 no.1
    • /
    • pp.63-72
    • /
    • 1993
  • In this paper, the effect of background grey levels on the visual perception of target image displayed on CRT monitor has been investigated. The purpose of this study is to investigate the efficacy of CRT monitor as a display medium of image Information especially in medical imaging field. Tllree sets of experiments have been performed in this study : the first was to measure the luminance response of CRT monitor and to find the best fitting equation, and the second was the psychophysical experiment measuring the threshold grey level differences between the target image and the background required for visual discrimination (or various background grey levels, and the third was to develop a visual model that is predictable of the threshold grey level difference measured in the psychophysical experiment. The result of psycophysical experiment shows that the visual perception performance is significantly degraded in the range of grey levels lower than 50, which is turned out due to she low luminance change of CRT monitor in this range while human eye has been adapted lo relatively bright ambient illumination. And it Is also shown in the simulation study using the developed visual model that the dominant factor degrading the visual performance is the reflected light from the monitor surface by ambient light in general illumination condition.

  • PDF

Real-Time Detection on FLUSH+RELOAD Attack Using Performance Counter Monitor (Performance Counter Monitor를 이용한 FLUSH+RELOAD 공격 실시간 탐지 기법)

  • Cho, Jonghyeon;Kim, Taehyun;Shin, Youngjoo
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.8 no.6
    • /
    • pp.151-158
    • /
    • 2019
  • FLUSH+RELOAD attack exposes the most serious security threat among cache side channel attacks due to its high resolution and low noise. This attack is exploited by a variety of malicious programs that attempt to leak sensitive information. In order to prevent such information leakage, it is necessary to detect FLUSH+RELOAD attack in real time. In this paper, we propose a novel run-time detection technique for FLUSH+RELOAD attack by utilizing PCM (Performance Counter Monitor) of processors. For this, we conducted four kinds of experiments to observe the variation of each counter value of PCM during the execution of the attack. As a result, we found that it is possible to detect the attack by exploiting three kinds of important factors. Then, we constructed a detection algorithm based on the experimental results. Our algorithm utilizes machine learning techniques including a logistic regression and ANN(Artificial Neural Network) to learn from different execution environments. Evaluation shows that the algorithm successfully detects all kinds of attacks with relatively low false rate.

Machine Learning-Based Detection of Cache Side Channel Attack Using Performance Counter Monitor of CPU (Performance Counter Monitor를 이용한 머신 러닝 기반 캐시 부채널 공격 탐지)

  • Hwang, Jongbae;Bae, Daehyeon;Ha, Jaecheol
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.30 no.6
    • /
    • pp.1237-1246
    • /
    • 2020
  • Recently, several cache side channel attacks have been proposed to extract secret information by exploiting design flaws of the microarchitecture. The Flush+Reload attack, one of the cache side channel attack, can be applied to malicious application attacks due to its properties of high resolution and low noise. In this paper, we proposed a detection system, which detects the cache-based attacks using the PCM(Performance Counter Monitor) for monitoring CPU cache activity. Especially, we observed the variation of each counter value of PCM in case of two kinds of attacks, Spectre attack and secret recovering attack during AES encryption. As a result, we found that four hardware counters were sensitive to cache side channel attacks. Our detector based on machine learning including SVM(Support Vector Machine), RF(Random Forest) and MLP(Multi Level Perceptron) can detect the cache side channel attacks with high detection accuracy.

Implementation of a Distributed System for Banking Accounting with the TP monitor (TP 모니터를 이용한 계정계 업무 분산 시스템 구축)

  • Lee, Sung-Joo;Choi, Wan-Gyu;Na, Young-Nam
    • The Transactions of the Korea Information Processing Society
    • /
    • v.4 no.11
    • /
    • pp.2651-2661
    • /
    • 1997
  • We can get very enhanced performance in case of adding the TP monitor to the on_line transaction processing system rather than just using the DBMS. Futhermore, It is getting boomed to establish a OLTP system with the TP monitor. We designed and implemented a distributed processing system with the TP monitor focused quick response time and expansionality and basic the ACID of transaction. In this paper, We explain the implementation about downsizing and upon distributed system and verified of performance.

  • PDF

Development of A Multipurpose Passive Type Radon Monitor (다목적 수동형 라돈농도 측정기 개발)

  • Lee, Bong-Jae;Park, Yeong-Ung
    • Radioisotope journal
    • /
    • v.21 no.4
    • /
    • pp.55-65
    • /
    • 2006
  • A passive type radon monitor adopting two silicon PIN detector as radiation detector has been developed, manufactured and test-evaluated. A radiation signal processing circuit has been electronically tested and then the radiation detection characteristics of this instrument has been performance-tested by using reference radon concentration and a reference photon radiation field. As a result, in a electronic performance test, radiation signals from each detector were well observed in each signal processing circuit. The radiation detection sensitivity of this instrument after several test-irradiations to a Cs-137 gamma radiation source and a standard radon concentration appeared to be 1.37 cph/$\mu$Svh-1 and 1.66 pCi/L respectively. The developed radon monitor in this paper could be used conveniently in monitoring of radon concentration in buildings which population utilize in Korea.

  • PDF

High Optical Performance of 7" Mini-monitor Based on 2D-3D Convertible Autostereoscopic Display

  • Kim, Sun-Kyung;Park, Sang-Hyun;Kim, You-Jin;Min, Kwan-Sik;Park, Seo-Kyu;Jhun, Chul-Gyu;Kwon, Soon-Bum
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.1367-1370
    • /
    • 2009
  • We have developed a 2D-3D convertible 7" autostereoscopic mini-monitor with high 3D quality, in which the parallax barrier LCD is attached on the TFTLCD. The excellent optical performance was achieved by design of the ghost free barrier and precise assembly between the barrier layer and the TFT-LCD panel. Our design principle and fabrication technology suppressed 3D cross-talk and improved viewing angle. In this paper, the design and fabrication process of the 3D mini-monitor are described. The evaluation for the 3D performance is also discussed.

  • PDF

Exploring Branch Target Buffer Architecture on Intel Processors with Performance Monitor Counter (Performance Monitor Counter를 이용한 Intel Processor의 Branch Target Buffer 구조 탐구)

  • Jeong, Juhye;Kim, Han-Yee;Suh, Taeweon
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2019.10a
    • /
    • pp.24-27
    • /
    • 2019
  • Meltdown, Spectre 등 하드웨어의 취약점을 이용하는 side-channel 공격이 주목을 받으면서 주요 microarchitecture 구조에 대한 철저한 이해의 필요성이 커지고 있다. 현대 마이크로프로세서에서 branch prediction이 갖는 중요성에도 불구하고 세부적인 사항은 거의 알려지지 않았으며 잠재적 공격에 대비하기 위해서는 반드시 현재 드러난 정보 이상의 detail을 탐구하기 위한 시도가 필요하다. 본 연구에서는 Performance Monitor Counter를 이용해 branch 명령어를 포함한 프로그램이 실행되는 동안 Branch Prediction Unit에 의한 misprediction 이벤트가 발생하는 횟수를 체크하여 인텔 하스웰, 스카이레이크에서 사용되는 branch target buffer의 구조를 파악하기 위한 실험을 수행하였다. 연구를 통해 해당 프로세서의 BTB의 size, number of way를 추정할 수 있었다.

Development and Performance Evaluation of a Real-time PM Monitor based on Optical Scattering Method (광산란방식을 이용한 미세먼지 실시간 모니터링 장치 개발 및 성능평가)

  • Kang, Doo Soo;Oh, Jung Eun;Lee, Sang Yul;Shin, Hee Joon;Bong, Ha Kyung;Kim, Dae Seong
    • Particle and aerosol research
    • /
    • v.14 no.4
    • /
    • pp.107-119
    • /
    • 2018
  • In this study, we have developed a real-time monitoring device for measuring PM10 and PM2.5 of ambient aerosol particles. The real-time PM monitor (SENTRY Dust Monitor) uses the optical scattering method and has 16 channels in particle size. The laboratory and field tests were carried out to evaluate the developed SENTRY Dust Monitor. Arizona Test Dust particles were used as test particles in the laboratory test and the field test was carried out at the Jongno-gu Observatory in Seoul. The measurements of PM10 and PM2.5 concentrations obtained by SENTTRY Dust Monitor were compared with Grimm Dust Monitor (Model 1.108) and a beta ray gauge. It was shown that the PM10 and PM2.5 concentrations obtained by SENTRY Dust Monitor agree well with that of the reference devices. Based on the results obtained in this study, it could be concluded that the SENTRY Dust Monitor can be used as a PM monitoring device for real-time monitoring of the ambient aerosols.