• Title/Summary/Keyword: performance characterization

Search Result 1,052, Processing Time 0.029 seconds

A Study on Performance Test Methods for Cooled Infrared Detector (냉각형 적외선 검출기 성능평가 기술 연구)

  • Kim, Jae-Won
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.13 no.4
    • /
    • pp.542-550
    • /
    • 2010
  • Cooled infrared detector is widely used as the core part in a variety of the thermal imaging systems. For the selection of the highly reliable cooled infrared detector with good performance, it is necessary for us to possess the characterization methods of the well defined performance index of cooled infrared detector. In this paper, various performance index of the cooled infrared detector including reliability as well as the optical and cooling performance of cooled infrared detector are defined and their characterization methods will be investigated and implemented systematically.

Image Quality Evaluation of Digital X-Ray Detector Using Amorphous Selenium Layer and Amorphous Silicon TFT Array (비정질 셀레늄층과 비정질 실리콘TFT배열을 사용하는 디지털 X-선 검출기의 영상특성 평가)

  • Kim, Chang-Won;Yoon, Jeong-Key;Kim, Jong-Hyo
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.219-226
    • /
    • 2008
  • In this study, we have conducted characterization of imaging performance for a flat panel digital X-ray detector using amorphous Selenium and a-Si TFT which was developed by the authors. The procedures for characterization were in concordance with internationally recommended standards such as IEC (international electrotechnical commission). The measures used for imaging performance characterization include response characteristic, modulation transfer function (MTF), detective quantum efficiency (DQE), noise power spectrum (NPS), and quantum limited performance. The measured DQEs at lowest and highest spatial frequencies were 40% and 25% respectively, which was superior to that of commercial products by overseas vendor. The MTF values were significantly superior to that of CR and indirect type DRs. The quantum limited performance showed the detector was limited by quantum noise at the entrance exposure level below 0.023 mR, which is sufficiently low for general X-ray examination.

  • PDF

THE USE OF NUMERICAL MODELS IN SUPPORT OF SITE CHARACTERIZATION AND PERFORMANCE ASSESSMENT STUDIES FOR GEOLOGICAL REPOSITORIES

  • Neerdael, Bernard;Finsterle, Stefan
    • Nuclear Engineering and Technology
    • /
    • v.42 no.2
    • /
    • pp.145-150
    • /
    • 2010
  • The paper is describing work being developed in the frame of a 5-year IAEA Coordinated Research Programme (CRP) started in late 2005. Participants gained knowledge of modelling methodologies and experience in the development and use of rather sophisticated simulation tools in support of site characterization and performance assessment calculations. These goals were achieved by a coordinated effort, in which the advantages and limitations of numerical models are examined and demonstrated through a comparative analysis of simplified, illustrative test cases. This knowledge and experience should help them address these issues in their own country's nuclear waste program. Coordination efforts during the first three years of the project aimed at enabling this transfer of expertise and maximizing the learning experience of the participants as a group. This was accomplished by identifying common interests of the participants (i.e., Process Modelling and Total System Performance Assessment methodology), and by defining complementary tasks that are solved by the members. Synthesis of all available results by comparative assessments is planned in the coming months. The project will be completed end of 2010. This paper is summarizing activities up to November 2009.

Characterization and surface engineering of two-dimensional atomic crystals

  • Yu, Yeong-Jun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.63.1-63.1
    • /
    • 2015
  • The next generation electronics need to not only be smaller but also be more flexible. To meet such demands, van der Waals (vdW) heterostructures using two dimensional (2D) atomic crystals such as graphene, hexagonal boron nitride (h-BN) and transition metal dichalcogenides (TMDCs) have been attracted intensely. In particular, for high performance of vdW heterostructures device, ultraclean interface between stacked 2D atomic crystals should be guaranteed. In this talk, I will present fabrication and characterization of the vdW field effect transistors toward performance enhancement by employing TMDCs channel, h-BN insulating layer and graphene electrode. Furthermore, it will also be introduced the characterization and surface engineering of graphene for gas molecule sensor.

  • PDF

The fabrication of electrode and characterization of performance in the PEMFC (고분자 연료전지의 전극 제조 및 성능 평가)

  • Park In-Su;Cho Yonghun;Choi Baeckbeom;Jung Daesik;Cho Yoonhwan;Sung Yung-Eun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.227-230
    • /
    • 2005
  • There is a worldwide interest In the development and commercialization of PEMFCs for vehicular and stationary applications. The major problem in the practical use of PEMFCs is the deactivation of the Pt anode electrocatalyst by the adsorption of carbon monoxide. Therefore, intensive work has been devoted to finding electrocatalysts that are tolerant to CO in hydrogen at operating temperatures bellow $100^{\circ}C$. Also, DMFC is considered to be one of the most promising technologies for energy generation. But, the most important problem associated with the DMFC is the slow reaction rate of methanol oxidation and the second major problem is fuel crossover. So, the performance of a state-of-the-art DMFC is considerably lower than that of hydrogen-fuelled PEMFC. In this research, the preparation and characterization of electrode materials will be introduced. Also, some electrochemical techniques for the characterization of PEMFCs will be presented.

  • PDF

Development of Piezoelectric Transducers For Measuring Dynamic Stiffness of Subsurface Materials (지반의 동적 물성치 측정을 위한 압전소자형 계측기 개발)

  • 목영진
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1997.10a
    • /
    • pp.101-108
    • /
    • 1997
  • A pair of piezoelectric transducers was developed for geotechnical site characterization in rock materials. SH-wave measurement capability of the transducers can provide a more complete characterization. The performance of the transducers was tested at a limestone site.

  • PDF

Thermal Characterization of Individual Pixels in Microbolometer Image Sensors by Thermoreflectance Microscopy

  • Ryu, Seon Young;Choi, Hae Young;Kim, Dong Uk;Kim, Geon Hee;Kim, Taehyun;Kim, Hee Yeoun;Chang, Ki Soo
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.15 no.5
    • /
    • pp.533-538
    • /
    • 2015
  • Thermal characterization of individual pixels in microbolometer infrared image sensors is needed for optimal design and improved performance. In this work, we used thermoreflectance microscopy on uncooled microbolometer image sensors to investigate the thermal characteristics of individual pixels. Two types of microbolometer image sensors with a shared-anchor structure were fabricated and thermally characterized at various biases and vacuum levels by measuring the temperature distribution on the surface of the microbolometers. The results show that thermoreflectance microscopy can be a useful thermal characterization tool for microbolometer image sensors.

Digital Video Camera Characterization Considering White Balance (White Balance를 고려한 디지털 비디오 카메라 Characterization)

  • 박종선;김대원;장수욱;김은수;송규익
    • Proceedings of the IEEK Conference
    • /
    • 2002.06d
    • /
    • pp.299-302
    • /
    • 2002
  • Digital video camera can be a useful tool to capture images for use in colorimeter. However, the RGB signals generated by different digital video camera are not equal for the same scene. The digital video camera for use in colorimeter is characterized based on the CIE standard colorimetric observer. One method of deriving a colorimetric characterization matrix between camera RGB output signals and CIE XYZ tristimulus values is Polynomial modeling. In this paper, 3${\times}$3 linear matrix and 3${\times}$l1 polynomial matrix is used to investigate the characterization performance of the professional digital video camera. In experimental results, it is demonstrated that proposed 3${\times}$3 linear matrix has a reasonable degree of accuracy for use in colorimeter.

  • PDF

Electrical Parameter Extraction of High Performance Package Using PEEC Method

  • Pu, Bo;Lee, Jung-Sang;Nah, Wan-Soo
    • Journal of electromagnetic engineering and science
    • /
    • v.11 no.1
    • /
    • pp.62-69
    • /
    • 2011
  • This paper proposes a novel electrical characterization approach for a high-performance package system using an improved Partial Element Equivalent Circuit (PEEC). As the effect of interconnects becomes a pivotal factor for the performance of high-speed electronic systems, there is a great demand for an accurate equivalent model for interconnects. In particular, an equivalent model of interconnects is established in this paper for the Fine-Pitch Ball Grid Array (FBGA) package using the improved PEEC method. Based on the equivalent model, electrical characteristics are analyzed; furthermore, these are verified through the measurement results of a Vector Network Analyzer (VNA).

Characterization of the performance of the next-generation controller for the BOES CCD

  • Park, Su-Hwan;Yu, Young Sam;Sung, Hyun-Il;Park, Yoon-Ho;Lee, Sang-Min;Bang, Seung-Cheol;Chun, Moo-Young;Seong, Hyeon-Cheol;Kim, Minjin
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.46 no.2
    • /
    • pp.76.2-76.2
    • /
    • 2021
  • We present the characterization of the performance of the next-generation controller (SDSU Gen III) for BOAO Echelle Spectrograph CCD (BOES CCD) at the Bohyunsan Optical Astronomy Observatory. The current controller (SDSU Gen II) of the BOES CCD will be upgraded to SDSU Gen III to provide a more stabilized operation. To assess the performance of the new controller (e.g., conversion gain, full well capacity, S/N), we obtain various types of calibration images (e.g., bias, flat, science images of standard stars). Based on those datasets, we find that the overall performance of the new controller is somewhat comparable to that of the old controller if the slow mode is adopted for the readout. This may demonstrate that the new controller can be successfully substituted for the old controller without a substantial loss of performance. However, further analysis with a large dataset obtained in various observational conditions is necessary to confirm our results.

  • PDF