• Title/Summary/Keyword: per unit quantity

Search Result 114, Processing Time 0.027 seconds

An EMQ Model with Rework (재작업이 수반되는 경우에서의 경제적 생산량 결정)

  • Kim, Chang Hyun
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.31 no.2
    • /
    • pp.173-179
    • /
    • 2005
  • This paper presents an extended EMQ model which determines an optimal production quantity for a single stage production system when defective items are stochastically produced in the production process and they are re-processed in the rework process to convert them into non-defectives. Through the mathematical modeling, an optimal solution minimizing the average cost per unit time and minimum average cost as well as some properties are derived. It can be shown that each of the existing models is a special case of the proposed model under some conditions. Numerical experiment is carried out to examine the behavior of the proposed model and support properties derived.

Generalized Single Manufacturer and Multiple Retailers Supply Chain Model in JIT Purchasing (JIT구매를 고려한 단일 제조업자-다소매업자의 공급사슬에서 통합재고모형)

  • Kim, Dae-Hong
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.34 no.4
    • /
    • pp.25-34
    • /
    • 2011
  • In this paper, we investigate an inventory system where a single manufacturer purchases and processes raw materials in order to deliver finished goods to multiple retailers. Earlier study in this type of supply chain only consider a single raw material in order to produce finished goods, but we consider multi-raw materials in order to produce finished goods. Also, we develop an iterative solution procedure to find the order quantity for the finished goods and raw materials, and the number of shipments between manufacturer and retailers that minimizes the total cost per unit time of the raw materials ordering and holding, manufacture's setup and finished goods holding, the retailer's ordering and inventory holding. Numerical examples are presented to illustrate that jointly considering the total cost results in less total cost than that of considering them separately.

Developing a Scanner for Assessing Foliage Moisture

  • Nakajima, Isao;Ohyama, Futoshi;Juzoji, Hiroshi;Ta, Masuhisa
    • Journal of Multimedia Information System
    • /
    • v.6 no.3
    • /
    • pp.155-164
    • /
    • 2019
  • We intended to confirm that microwave attenuation by tree leaves is strongly linked to water content in leaves. We sampled natural broadleaves, including Japanese cinnamon, and investigated their effects on the microwave (3 to 20 GHz) frequency characteristics using a network analyzer. Experiments determined that microwave attenuation by foliage increases as a linear function of frequency per unit weight (gram). As the frequency increases, the spatial resolution increases, but the phase difference (imaginary component) increases. So we solved the dispersion of phase difference by sweeping the frequency and taking the intermediate value. Based on these experimental results, we developed a microwave scanner on 10Ghz to describe foliage moisture as a image and to enable assessments of leaf condition. Photosynthesis is the process whereby plants synthesize oxygen and sugars from carbon dioxide and water, thereby converting light energy into chemical energy. Since water is a major parameter of photosynthesis, the quantity of water accumulated inside a leaf reflects leaf health. The equipment described here and related microwave technologies will help assess the capacity of leaves to absorb atmospheric carbon dioxide.

Standardization and Method Selection for the Trenchless Repair Technology of Sewer using Cured-in-place Pipe

  • Kim, Taeeung
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.14 no.2
    • /
    • pp.70-78
    • /
    • 2022
  • The trenchless entire repair technology (TERT) have many different names depending on the companies, and they have the same or similar methods as well as materials. In addition, there was quiet difficulty in application of field working and even confuse to classify for new TERT, while application criteria of TERT is not listed systematically. This study proposed standardization and method for TERT affecting by pipe condition, working materials, working method, specification/quantity per unit according to field condition, strange affairs and others. Determination criteria of defective sewer pipe has proposed to effective method which modify a criteria between Ministry of Environment and Seoul Metropolitan City. A Cured-in-place pipe (CIPP) is suitable for TERT, and the design criteria for the entire broken pipe are proposed when the pipe itself deforms more than 10%. A check lists are specimen preparing, hardening site made by clamped mold, numbers, flexural and tensile property, water leak and desquamation test, and have to use material property of minimum CIPP value depend on ISO 11296-4, ISO 11297-4, KS M3550-7 and KS M3550-9.

Revisions on the payline for overbreak in Tunnel

  • Park, T.;Ahn, B.;Baek, S.;Tae, Y.
    • International conference on construction engineering and project management
    • /
    • 2015.10a
    • /
    • pp.714-715
    • /
    • 2015
  • Drill and blast method has been most widely used in tunnel excavation, after NATM (New Austrian Tunneling Method) was introduced in 1983. The NATM method utilized mass of shotcrete to secure the bearing capacity of tunnels. Overbreak defined how much larger the actual excavation was than the planned. When it became larger, more shotcrete was required to fill in it Here, payline fixed allowable overbreak, referring to payable amounts of shotcrete. Since owner was not responsible for shotcrete exceeding payline, it was important to properly establish the standards for payline. Although the standards were provided in 'Poom-sam'(standardized quantity per unit), they did not properly reflect the actual conditions for excavation. Thus, this study reviewed existing domestic and foreign standards for overbreak, and estimated overbreak for each type of support using survey data, and finally provided the improvements on the current standards.

  • PDF

Distribution Characteristics of Bottom Litter in Chinhae Bay, Korea

  • Kim Jong-Hwa;Kim Sam-Kon;Kim Jong-Kyu
    • Fisheries and Aquatic Sciences
    • /
    • v.4 no.3
    • /
    • pp.150-158
    • /
    • 2001
  • A study on the amount, distribution and item of bottom litter on the sea-bed was conducted by the bottom trawl net at 5 sections in Chinhae Bay over a year. The number and weight of litter found per unit of swept area (1 hectare) in each section were estimated as the range of 8.76-80.63 pieces, 3.51-108.39kg, respectively. The seasonal variation of high (Aug., '97) and low season (Feb., '98) in quantity was small, and it was about 2 times as the range of 24.58- 52.61 pieces/ha between them. But the weight variation between high (Apr., '98) and low season (Aug., '97) was very large, about 30 times as the range of 4.06-119.64kg/ha. The largest and second composition on the weight of bottom litter in Chinhae Bay are $76\%$ in other-litter with compound and bulky materials, and $93\%$ in fishing gear, respectively. The relationship between quantity and weight of bottom litter was not occurred due to the variety of specific gravity. Of the fishing gear, fishing nets was portioned to be 2.571kg/ha in weight and $84.9\%$ in composition. So these results prove that fishing nets were discarded as the most part of fishing gear during fishing activity in the bay. The largest composition of the soiled state classified into 3 styles in overall bottom litter was $69\%$ in very soiled state, and the second one of $28\%$ in the soiled state. On the other hand, new state is very small and portioned in $3.0\%$ of all. Chinhae Bay was estimated to be about 10 times in quantity and about 36 times in weight of Tokyo Bay. Therefore, these suggest that Chinhae Bay is a very serious polluted estuary caused by the bottom litter such as heavy and bulky wastes, fishing gear.

  • PDF

A study of a combined release model using perturbation solutions (섭동해를 이용한 혼합 누출에 관한 연구)

  • Kim, Myungbae
    • Journal of Energy Engineering
    • /
    • v.23 no.4
    • /
    • pp.41-48
    • /
    • 2014
  • Leak of liquid has been categorized conventionally into instantaneous release and continuous release. In this study, the spread of cryogenic liquid due to limited period of release is investigated for the first time to establish a new classification method with recognizing the irrationality of the conventional one. Such physical phenomena are governed by simultaneous equations concerning volume, radius and height of pool of the cryogenic liquid, and major parameters are evaporation rate per unit area, time of release, and spill quantity. The simultaneous governing equations is decoupled to get efficiently perturbation solutions. As the results, for the same spill quantity, in view of release model, combined release model that consists of continuous and consecutive instantaneous model is necessary with small time of release, while continuous model is solely required with large time of release. Also, the combined model is necessary for small spill quantity with the same time of release. These two regimes of release are clearly distinguished using the perturbation solution to provide a clear basis for the new classification of release models.

Optimized Conditions for In Situ Immobilization of Lipase in Aldehyde-silica Packed Columns

  • Seo Woo Yong;Lee Kisay
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.9 no.6
    • /
    • pp.465-470
    • /
    • 2004
  • Optimal conditions for the in situ immobilization of lipase in aldehyde-silica packed columns, via reductive amination, were investigated. A reactant mixture, containing lipase and sodium borohydride (NaCBH), was recirculated through an aldehyde-silica packed column, such that the covalent bonding of the lipase, via amination between the amine group of the enzyme and the aldehyde terminal of the silica, and the reduction of the resulting imine group by NaCBH, could occur inside the bed, in situ. Mobile phase conditions in the ranges of pH $7.0{\~}7.8$, temperatures between $22{\~}28^{circ}C$ and flow rates from $0.8{\~}1.5\;BV/min$ were found to be optimal for the in situ immobilization, which routinely resulted in an immobilization of more than 70 mg­lipase/g-silica. Also, the optimal ratio and concentration for feed reactants in the in situ immobilization: mass ratio [NaCBH]/[lipase] of 0.3, at NaCBH and lipase concentrations of 0.75 and 2.5 g/L, respectively, were found to display the best immobilization characteristics for concentrations of up to 80 mg-lipase/g-silica, which was more than a 2-fold increase in immobilization compared to that obtained by batch immobilization. For tributyrin hydrolysis, the in situ immobilized lipase displayed lower activity per unit mass of enzyme than the batch-immobilized or free lipase, while allowing more than a $45\%$ increase in lipase activity per unit mass of silica compared to batch immobilization, because the quantity of the immobilization on silica was aug­mented by the in situ immobilization methodology used in this study.

A Design of Embedded LED Display Board Module and Control Unit which the Placement of Pixels is Free (픽셀 배치가 자유로운 임베디드 LED 전광판 모듈 및 제어장치 설계)

  • Lee, Bae-Kyu;Kim, Jung-Hwa
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.10
    • /
    • pp.135-141
    • /
    • 2013
  • In this paper, we installed three high brightness red, green, and blue LED in one socket and made one pixel unit. And we also developed the full-color display board module and control unit which can express various images such as text, graphics, video image with the combination of pixel units and a number of modules. LED display driver module have a driver circuit within the combination of the RGB pixel dot on unit area. These modules of the existing form can be high priced because of implementation a fixed resolution in specific space and installation space. To overcome these shortcomings, we developed a LED driver and LED pixel modules free in array at random pitch intervals. Display board module of this paper enabled to display smoothly video image which have many data processing quantity through dragging data speed up 36 frames per second. Also there are an effect which is provided more clear image because of improving the flickering of the existing display board.

Determination of Nursing Costs for Hospitalized Patients Based on the Patient Classification System (종합병원에 입원한 환자의 간호원가 산정에 관한 연구)

  • 박정호;송미숙
    • Journal of Korean Academy of Nursing
    • /
    • v.20 no.1
    • /
    • pp.16-37
    • /
    • 1990
  • A cost analysis for hospitalized patients was carried out based upon Patient Classification System(PCS) in order to determine an appropriate nursing fee. The data were collected from 21 nursing units of three teaching hospitals from April 1 to June 30, 1989. first, all of the 22,056 inpatients were classified into mildly ill(Class Ⅰ), moderately ill(Class Ⅱ), acutely ill(Class Ⅲ), and critically ill(Class Ⅳ) by the PCS which had been carefully developed to be suitable for the Korean nursing units. Second. PCS cost accounting was applied to the above data. The distribution of inpatients, nursing costs, and nursing productivity were as follows : 1) Patient distribution ranged from 45% to class Ⅰ, 36% to class Ⅱ, 15% to class Ⅲ, and 4% to class Ⅳ, the proportion of class Ⅳ in ‘H’ Hospital was greater than that of the other two hospitals. 2) The proportion of Class Ⅲ and Ⅳ in the medical nursing units was greater than that of surgical nursing units. 3) The number of inpatients was greatest on Tuesdays, and least on Sundays. 4) The average nursing cost per hour was W 3,164 for ‘S’ hospital, W 3,511 for ‘H’ hospital and W 4,824 for ‘K’ hospital. The average nursing cost per patient per day was W 14,126 for ‘S’ Hospital, W 15,842 for ‘H’ hospital and W 21,525 for ‘K’ hospital. 5) The average nursing cost calculated by the PCS was W 13,232 for class Ⅰ, W 18,478 for class Ⅱ, W 23,000 for class Ⅲ, and W 25,469 for class Ⅳ. 6) The average nursing cost for the medical and surgical nursing units was W 13,180 and W 13,303 respetively for class Ⅰ, W 18,248 and W 18,707 for class Ⅱ, W 22,303 and W 23,696 for class Ⅲ, and W 24,331 and W 26,606 for class Ⅳ. 7) The nursing costs were composed of 85% for wages and fringe benefits, 3% for material supplies and 12% for overhead. The proportion of wages and fringe benefits among the three Hospitals ranged from 75%, 92% and 98% for the ‘S’, ‘H’, ‘K’ hospitals respectively These findings explain why the average nursing cost of ‘K’ hospital was higher than the others. 8) According to a multi- regression analysis, wages and fringe benefits, material supplies, and overhead had an equal influence on determining the nursing cost while the nursing hours had less influence. 9) The productivity of the medical nursing units were higher than the surgical nursing units, productivity of the D(TS) - nursing units was the lowest while the K(Med) - nursing unit was the highest in 'S' hospital. In ‘H’ hospital, productivity was related to the number of inpatients rather than to the characteristics of the nursing units. The ‘K’ hospital showed the same trend as ‘S’ hospital, that the productivity of the medical nursing unit was higher than the surgical nursing unit. The productivity of ‘S’ hospital was evaluated the highest followed by ‘H’ hospital and ‘K’ hospital. Future research on nursing costs should be extended to the other special nursing areas such as pediatric and psychiatric nursing units, and to ICU or operating rooms. Further, the PCS tool should be carefully evaluated for its appropriateness to all levels of institutions(primary, secondary, tertiary). This study took account only of the quantity of nursing services when developing the PCS tool for evaluating the productivity of nursing units. Future research should also consider the quality of nursing services including the appropriateness of nursing activities.

  • PDF