• Title/Summary/Keyword: penumbra

Search Result 126, Processing Time 0.029 seconds

Effect of Chungpaesagan-tang on cerebral Ischemic Damage Induced by MCAO in Rats (청폐사간탕(淸肺潟肝湯)이 MCAO에 의한 흰쥐의 뇌허혈 손상에 미치는 영향)

  • Jung, Gwang-Sik;Kim, Bum-Hoi;Hwang, Won-Duk
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.13 no.1
    • /
    • pp.13-27
    • /
    • 2009
  • This study aimed to validate neuroprotective effect of Chungpaesagan-tang on the early stage of cerebral ischemic damage. Cerebral ischemic damage was induced by the middle cerebral artery occlusion (MCAO) for 2 hours in the Sprague-Dawley rats. Water extract of Chungpaesagan-tang(8.7g/kg) was administered orally twice at 1 and 4 hours after the MCAO. Neurological score was tested at 3 and 24 hours after the MCAO and Chungpaesagan-tang administration. At 24 hours after the MCAO, infarct volume and edema ratio was evaluated with the TTC staining. Apoptotic cell death in cerebral cortex and caudate putamen was observed with cresyl violet staining and TUNEL labeling. Bax expression in the MCAO rat brain was stained with immunohistochemistry. Chungpaesagan-tang improved neurological and behavioral impairment of the MCAO rats and reduced infarct area, infarct volume and brain edema formation. Chungpaesagan-tang attenuated cell death percentage in cortex penumbra and reduced TUNEL positive cells in cortex penumbra and in caudate putamen of the MCAO rats. Chungpaesagan-tang reduced Bax positive neurons in caudate putamen and reduced c-Fos positive neurons in cortex penumbra of the MCAO rats. Chungpaesagan-tang intensified neuronal HSP72 expression in cortex penumbra of the MCAO rats. In results, Chunpaesagan-tang reduces infarct volume and edema formation through anti-apoptotic effect. This result suggests that Chunapaesagan-tang has an adequate neuroprotective effect on the early stage of cerebral ischemic damage.

  • PDF

Dose Distribution and Characterization for Radiation Fields of Multileaf Collimateor System (방사선 입체조형치료용 다엽콜리메이터의 특성과 조직내 선량분포 측정)

  • Chu, Sung-Sil;Kim, Gwi-Eon
    • Radiation Oncology Journal
    • /
    • v.14 no.1
    • /
    • pp.77-85
    • /
    • 1996
  • Purpose : Multileaf collimator(MLC) is very suitable tool for conformal radio-therapy and commissioning measurements for a multileaf collimator installed on a dual energy accelerator with 6 and 10MV photons are required, For modeling the collimator with treament planning software, detailed dosimetric characterization of the multileaf collimator including the penumbra width, leaf transmission between leaf leakage and localization of the leaf ends and sides is an essential requirement. materials and Methods : Measurement of characteristic data of the MLC with 26 pair block leaves installed on CLINAC 2100C linear accelerator was performed. Low sensitive radiographic film(X-omatV) was used for the penumbra measurement and separate experiments using radiographic film and thermoluminescent dosimeters were performed to verify the dose distribution, Measured films were analized with a photodensitometer of WP700i scanner. Results : For 6 & 10 MV x-ray energies, approximately $2.0\%$ of photons incident on the multileaf collimator were transmitted and an additional $0.5\%$ leakage occurs between the leaves. Localizing the physical end of the leaves showed less than 1mm deviation from the $50\%$ decrement line and this difference is attributed to the curved shaped end on the leaves One side of a sin히e leaf corresponded to the $50\%$ decrement line, but the opposite face was aligned with a lower value. This difference is due to the tongue and groove used to decrease between leaf leakage. Alignment of the leaves to form a straight edge resulted larger penumbra at far position from isocenter as compare with divergent alloy blocks. When the MLC edge is stepped by sloping field, the isodose lines follow the leaf pattern and Produce scalloping isodose curves in tissue. The effective penumbra by 45 degree stepped MLC is about 10mm at 10cm depth for 6MV x-ray. The difference of effective penumbra in deep tissue between MLC and divergent alloy blocks is small (5mm). Conclusion : Using the characteristic data of MLC, the MLC has the clinlical acceptability and suitability for 3-D conformal radiotherapy except small field size.

  • PDF

Effect of Daeseungki-tang on Apoptotic Neuronal Cell Death of MCAO Rats (대승기탕(大承氣湯)이 중대뇌동맥 폐쇄 흰쥐의 신경세포 자연사에 미치는 영향)

  • Choi, Eun-Bin;Kim, Youn-Sub
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.22 no.2
    • /
    • pp.403-409
    • /
    • 2008
  • In Oriental medicine daeseungki-tang is one of the prescription that is used clinically for constipation of paralytics. The objective of the study was to observe the effect of daeseungki-tang on apoptotic neuronal cell death. In the present study, middle cerebral artery occlusion(MCAO) rats were treated with daeseungi-tang for 5 days and the edema percentage of cerebral hemisphere of MCAO rats were investigated primary. Secondary, appearances of Bax, Bcl-2,-factors that is related to apoptotic neuronal cell death - and HSP72 in the brain of MCAO rats were investigated via immunohistochemistry. Daeseungki-tang significantly decreased edema percentage of the cerebral hemisphere of MCAO rats. Daeseungki-tang significantly decreased Bax positive cells, but did not change the apperances of Bcl-2 positive cells in the penumbra of the cerebral cortex and the caudoputamen of MCAO rats. Daeseungki-tang significantly decreased HSP72 positive cells in the penumbra of the cerebral cortex, but not in the caudoputamen of MCAO rats. Based on the present results, it can be suggested that treatment with daeseungki-tang may decrease edema of the cerebral hemisphere and restrain apoptotic neuronal cell death in the penumbra of the cerebral cortex.

Initial Experience of ACE68 Reperfusion Catheter in Patients with Acute Ischemic Stroke Related to Internal Carotid Artery Occlusion

  • Jang, Hyoung-Gyu;Park, Jung-Soo;Lee, Jong-Myong;Kwak, Hyo-Sung
    • Journal of Korean Neurosurgical Society
    • /
    • v.62 no.5
    • /
    • pp.545-550
    • /
    • 2019
  • Objective : Penumbra ACE68 reperfusion catheter is a new large bore aspiration catheter used for reperfusion of large vessel occlusion. The objective of this study was to investigate the efficacy of this catheter in comparison to that of previous Penumbra catheters in patients with acute ischemic stroke related to internal carotid artery (ICA) occlusion. Methods : Data of all eligible patients who received endovascular treatment (EVT) for ICA occlusion using Penumbra aspiration catheters between January 2015 and December 2018 were retrospectively reviewed. After dividing into two groups according to use of penumbra ACE68, baseline characteristics of patients, successful recanalization rate, puncture to recanalization time, and switch to stent base technique rate were assessed. Successful recanalization was defined by a thrombolysis in cerebral infarction (TICI) score ${\geq}2b$ and favorable functional outcome was defined according to modified Rankin scale (score, 0-2). Results : ACE68 reperfusion catheter was used in 29 of 75 eligible patients (39%). The puncture to recanalization time was significantly shorter ($26{\pm}18.2$ minutes vs. $40{\pm}24.9$ minutes, p=0.011) and the rate of switch to stent-based retrieval was significantly lower (3% vs. 20%, p=0.046) in ACE68 catheter group. Moreover, although not statistically significant, the successful recanalization rate was higher (83% vs. 76%, p=0.492) in ACE68 catheter group. Favorable functional outcome was observed in 48% of patients treated with ACE68 reperfusion catheter and in 30% of patients treated using other Penumbra systems (p=0.120). Baseline Alberta Stroke Program Early CT Scores ${\geq}8$ (odds ratio [OR], 9.74; 95% confidence interval [CI], 1.72-54.99; p=0.010) and successful recanalization (OR, 10.20; 95% CI, 1.13-92.46; p=0.039) were independent predictors of favorable outcome. Conclusion : EVT using ACE68 reperfusion catheter can be considered a first-line therapy in patients with acute ICA occlusion as it can achieve rapid recanalization and reduce the frequency of conversion to stent-retrieve therapy.

POLARIZATION-MAGNETIC FIELD CALIBRATION CURVE (편광-자기장 눈금조정 곡선)

  • Kim, Kap-Sung
    • Publications of The Korean Astronomical Society
    • /
    • v.12 no.1
    • /
    • pp.1-21
    • /
    • 1997
  • We have obtained theoretical calibration curves to convert the amount of polarization into the strength of magnetic field, by a numerical calculation of radiation transfer for the polarized spectral line of FeI $6303{\AA}$. In our calculation, three kinds of atmospheric models (VAL-C, penumbra, umbra) have been used to make a proper calibration for an active region composed of quiet, penumbral and umbral areas. It was found that firstly, the results of our calculation depend highly on a kind of atmospheric model rather than on any other input parameters used in a model. Secondly, observed line profile showed m solar spectrum atlas proved to be very similar to the calculated profiles obtained by using a penumbra model. Finally, another method except this calibration curve should be developed to estimate correctly the distribution of magnetic field in solar active region from the observation of polarized spectral line.

  • PDF

Surgical Managements of Ischemic Stroke (뇌허혈증의 외과적 치료)

  • Choe, Byeong-Yeon
    • Journal of Yeungnam Medical Science
    • /
    • v.11 no.2
    • /
    • pp.202-212
    • /
    • 1994
  • 뇌헐혈증은 다양한 요인으로 유발될 수 있겠으나 궁극적으로는 국소적 뇌혈류량이 적정수준 이하로 감소됨으로 해서 초래된다. 이렇게 뇌혈류가 감소된 부위의 중심에는 이미 괴사가 일어난 부위도 있겠지만, 그 주위에 현재 뇌기능은 없으나 장차 혈류가 충분해 지면 소생 가능한 penumbra 영역이 있다. 이런 penumbra영역으로 다시 혈류가 충분히 보충되면 뇌기능이 소생되어 호전의 양상을 보이게 되나, 혈류가 계속 저하되어 있으면 비가역적 뇌손상을 받게 되어 증상이 악환된다. 병변 부위는 자율조절기능(autoregulation)이 파괴되어 혈관이 이완된 상태이기 때문에 측부혈행을 통하여 뇌혈류를 공급시키기기 위해서 혈압을 올리면서 혈액유동을 원활하게 해주는 보존적인 방법을 시행하면서 적응증이 되는 경우에는 수술적으로 외내경동맥문합술과 같은 여러 방법의 bypass혈관 수술이나 경동맥내막절제술로 뇌허혈 부위에 뇌혈류를 적극적으로 증강시켜 호전시킬 수 있다.

  • PDF

An Algorithm for Generating the Umbra from a Convex Quadric Light Source (볼록 이차 광원으로부터 완전음영부를 생성하는 알고리즘)

  • Yoo, Kwan-Hee;Shin, Sung-Yong
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.27 no.6
    • /
    • pp.541-548
    • /
    • 2000
  • An area light source in the three dimensional space shines past a scene polygon, to generate two types of shadow volumes for each scene polygon, i.e., one with partial occlusion and the other with the complete occlusion. These are called, penumbra and umbra, respectively. In this paper, consider the problem for computing the umbra of a convex polygon from convex quadric light sources such as circles, ellipses, spheres, ellipsoids and cylinders. First, we give characteristics of the boundary surfaces of the umbra and then propose an algorithm for generating the umbra using them.

  • PDF

Effects of Dodam-tang on Cerebral Ischemic Damage of Hyperlipidemic Rats (도담탕(導痰湯)이 고지혈증 흰쥐의 뇌허혈 손상에 미치는 영향)

  • Kim, Kyung-Hun;Kim, Do-Hoon;Kim, Youn-Sub
    • The Korea Journal of Herbology
    • /
    • v.29 no.5
    • /
    • pp.23-30
    • /
    • 2014
  • Objectives : Dodam-tang has been reported to have a control effect against the hyperlipidemia and thrombosis. Based upon these previous reports, this study investigates the effects of Dodam-tang on the cerebral ischemic damage of the hyperlipidemic rats. Methods : Hyperlipidemia was induced by the beef tallow 30% diet for 14 days on Sprague-Dawley rats. Ischemic damage was induced by the middle cerebral artery occlusion (MCAO) for 2 hours with the intraluminal thread method. Then water extract of Dodam-tang was administered daily for 5 days. The effect of Dodam-tang was evaluated with the serum lipids, infarct volume and edema percentage, and immunohistochemical expressions of iNOS, MMP-9, and GFAP in the brain tissue. Results : The obtained results were as follows; Dodam-tang reduced significantly the infarct size in a TTC-stained 5th brain section of the hyperlipidemic MCAO rats. Dodam-tang suppressed the infarct volume of the hyperlipidemic MCAO rats, but not significant statistically. Dodam-tang suppressed the edema percentage of the hyperlipidemic MCAO rats significantly in the brain tissue. Dodam-tang suppressed significantly the iNOS expression in the cerebral penumbra and caudate putamen of the hyperlipidemic MCAO rats. Dodam-tang suppressed significantly the MMP-9 expression in the cerebral penumbra of the hyperlipidemic MCAO rats. Dodam-tang suppressed significantly the GFAP-expressed atrocytes in the cerebral penumbra of the hyperlipidemic MCAO rats. Conclusions : These results suggest that Dodam-tang suppresses the brain edema formation through the suppression of the iNOS, MMP-9 and GFAP, but the neuroprotective effect against the cerebral infarct are not distinct.

Evaluation of Comparison of Noise Power Spectrum according to the Time of Using Electronic Portal Imaging Device (EPID) for LINAC System (선형가속기의 시간에 따르는 전자조사문영상기구의 잡음전력스펙트럼 비교 평가)

  • Jung-Whan Min;Hoi-Woun Jeong
    • Journal of radiological science and technology
    • /
    • v.47 no.2
    • /
    • pp.117-123
    • /
    • 2024
  • This study was to assessment of quality assurance (QA) and noise characteristics of Noise Power Spectrum (NPS) according to the time of by using electronic portal imaging device (EPID) for LINAC (Linear Accelerator). LINAC device was (Varian ClinacR iX LINAC, USA) used and the were 40 × 30 cm2 of detector size were 1024 × 768 photo-electric diode array size. Signal could be obtained the K-space image of white noise images for NPS and we used to Overlap, Non-Overlap, Out of Penumbra, Flatness, Symmetry, Symmetry Rt, Lt methods. The 2013s NPS image Out of Penumbra quantitatively value more than 2013s NPS image Symmetry Rt, Lt methods quantitatively NPS based on the frequency of 1.0 mm-1. Thus, the 2022s NPS image Out of Penumbra quantitatively value more than 2022s NPS image Symmetry Rt, Lt methods quantitatively NPS based on the frequency of 1.0 mm-1. The assessment of comparison of white noise for NPS image noise and intensity of this study were to that should be used efficiently of the LINAC EPID detector system for Overlap method for International Electro-technical Commission (IEC).

Study on the beam properties of small field sizes (소조사면 전량분포의 특성에 관한 고찰)

  • Cho JeongHee;Lee SangKyu;An SeungKwon;Park Jell
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.1
    • /
    • pp.1-9
    • /
    • 2004
  • Purpose : The aim of this study is to investigate the properties of small field size and to measure the penumbra and central axis depth dose varying to the jaw setting and off axis distance for indicate this data to small field sizes radiation therapy. Material and methods : The percentage depth dose, beam profile and central axis output dose was measured by farmer type ion chamber and pinpoint chamber using Primart linac with 6MV energy. Beam quality and penumbra variations according to the central axis shift, from center to every 2cm outside increment, and field size, from $1{\times}1cm$ to $10{\times}10cm$ was investigated and compared with that of the standard geometrical condition's results Results : The differences of measured values between two ion chamber was about $37\%$ at 10cm depth with $1{\times}1cm$ field sizes but as field size increased this differences was diminished gradually. Measured data from various off axis distance with the different asymmetric collimations are not changed significantly but as size decreased the dose variation was increased and at $1{\times}1cm$ field size dose difference among off axis distance was as much as $13\%$, and as shallower the measured depth the central axis dose variations among the OAD was increased, penumbra was not changed noticeably depending on off axis distance but the percentage of penumbra from its initial field sizes was strongly dependant on field sizes and penumbra occupation rates of its own field sizes ranging from $6\%$ at $10{\times}10cm$ to $50\%$ at $1{\times}1cm$ field size. Conclusion : For imrt treatment, there are several numbers of different gentry angles with beams of nonuniform fluences are required and several complex factors involved. Among them the characteristics of beam output varying to the geometrical setting and design of collimators are of important to attaining a good treatment results. As mentioned in results the differences of measured values are changed significantly depends on ion chamber volume, depths and field size. For providing quality radiation treatment, especially at small field size, those factor's should have considering deliberately.

  • PDF