• Title/Summary/Keyword: peak time

Search Result 4,694, Processing Time 0.045 seconds

A study on the Management of Non-point Source Using Peak Water Quality Concentration (첨두수질농도를 이용한 비점오염원 관리방안 연구)

  • Kal, Byungseok;Park, Jaebeom;Kwon, Heongak;Im, Taehyo;Lee, Jiho
    • Journal of Wetlands Research
    • /
    • v.19 no.3
    • /
    • pp.287-295
    • /
    • 2017
  • In this study, rainfall runoff characteristics according to peak concentration were analyzed using the water quality and flow data in the Geumho river, and the direction of nonpoint source management such as monitoring and management period by pollution source was derived. Peak Water Quality Concentration is the concept that utilizes the extreme value as the concentration of non-point pollution control standard with the highest water quality in the rainwater runoff. Using this method, the evaluation factors such as cumulative precipitation(total precipitation), peak water quality concentration, cumulative precipitation up to peak water quality concentration, time to peak water quality concentration, and EMC to peak water quality concentration were examined and long- Rainfall runoff characteristics of nonpoint sources were analyzed. The results of the analysis suggested proper monitoring and management method to manage nonpoint source.

The Study on Temperature Measurement for the Standardization of Moxibustion (구법(灸法)의 표준화를 위한 온도 측정 연구(硏究))

  • Kim, Yoon-Hong;Lee, Seung-Ho;Yeo, Su-Jung;Choe, Il-Hwan;Kim, Young-Kon;Lim, Sabina
    • Journal of Acupuncture Research
    • /
    • v.25 no.2
    • /
    • pp.129-138
    • /
    • 2008
  • Objectives : The moxibustion is the method in using the heat stimulation made of attached and burned a moxa or other herbal materials on a healing point or acupuncture point and the chemical stimulation of a resin made from burning them. We need to standardize the characteristics of moxa combustion in order to get more systematic and objective result in operation mechanism and effects and then get more clinical abilities in these fields. Methods : In this study, using of labview system on the moxibustion. 1. we studied relation the size of barley and jujube seed with the moxa cone's peak combustion temperature and then measured and compared the moxa cone's peak combustion temperature by tonification and sedation method. 2. we measured the peak combustion temperature of indirect moxibustion. Results & comclusions : 1. When we measured a direct moxibustion's combustion temperature, the jujube seed sized moxa cone's peak temperature was higher than the barley sized moxa cone's when it burned and the time to peak temperature of the barley sized moxa cone was shorter than the jujube seed sized moxa cone's. 2. When the direct moxibustion was burned by the tonification and sedation method, the sedation method's peak temperature was higher than the tonification method's, the tonification's time to peak temperature was shorter than the sedation method's. 3. When we measured the temperature of the moxa combustion in the kinds of sliced herbal materials, the peak temperature of indirect moxibustion with a ginger when it sliced a 1.3mm size and a 1.5mm size was degreed within $40^{\circ}C$ to $52^{\circ}C$ and the peak temperature of indirect moxibustion with a garlic when it sliced a 1.7mm size was degreed within $46^{\circ}C$ to $62^{\circ}C$.

  • PDF

A Clock Frequency Detector for Improving Certainty of the Embedded System (임베디드 시스템의 정확성 향상을 위한 클럭 주파수 검출기)

  • Jeong, Gwanghyeon
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.23 no.5
    • /
    • pp.516-522
    • /
    • 2020
  • In this paper, the frequency detector which detects the clock frequency of the embedded system is proposed and analyzed. The proposed frequency detector is consisted of filter and peak voltage detector. The clock signal is converted from square wave to triangular wave by the filter. The peak voltage of the triangular wave is determined according to the frequency response of filter. The peak voltage detector detects and holds the peak voltage of the signal. Moreover, the proposed clock frequency detector can detect the frequency within 1ms and it gives guarantee of real-time operation.

Improved methods for measuring early reflections from Five-channel room impulse response using newly introduced Peak-Detecting algorithm

  • Kim Lae-Hoon;Doo Sejin;Oh Yangki;Lee Heewon;Sung Koeng-Mo
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.439-442
    • /
    • 2000
  • When we measure the acoustical properties of a room using multiple microphone system, it is important to grasp exact time delay of the early reflections from impulse response pair. But it is often very difficult to identify the early reflections in natural shape, because a waveform may be deformed due to the characteristics of a sound source loudspeaker, microphone and reflected wall and overlapping of plural waveform. In this paper to obtain more accurate and enough early reflections, we propose the brand-new five-channel sound receiving system and introduce peak-detecting algorithm. The system has microphones mounted at the origin and four points of a regular tetrahedron. The newly introduced peak-detecting algorithm can show exact peak position in each channel, in spite of deformation due to reflected walls, loudspeaker and microphone.

  • PDF

A novel Kohonen neural network and wavelet transform based approach to Industrial load forecasting for peak demand control (최대수요관리를 위한 코호넨 신경회로망과 웨이브릿 변환을 이용한 산업체 부하예측)

  • Kim, Chang-Il;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.301-303
    • /
    • 2000
  • This paper presents Kohonen neural network and wavelet transform analysis based technique for industrial peak load forecasting for the purpose of peak demand control. Firstly, one year of historical load data were sorted and clustered into several groups using Kohonen neural network and then wavelet transforms are adopted using the Biorthogonal mother wavelet in order to forecast the peak load of one hour ahead. The 5-level decomposition of the daily industrial load curve is implemented to consider the weather sensitive component of loads effectively. The wavelet coefficients associated with certain frequency and time localization is adjusted using the conventional multiple regression method and the components are reconstructed to predict the final loads through a six-scale synthesis technique.

  • PDF

Equivalent linearization of friction damper and brace system based on peak distribution (응답의 피크분포에 기초한 마찰감쇠기의 등가선형화)

  • Park, Ji-Hun;Min, Kyung-Won;Moon, Byoung-Wook
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2005.03a
    • /
    • pp.437-444
    • /
    • 2005
  • An equivalent linearization technique based on Rayleigh peak distribution for friction damper and brace system (FDBS) under stochastic excitation is proposed. For verification, shaking table test of a small scale 3-story building model with the FDBS is conducted for various slip moment levels. Using experimental result, equivalent linearization of the FDBS is conducted based on Rayleigh peak distribution, which is compared with measured peak distribution. For comparative study, model updating technique is applied based on identified modal properties. Finally, complex modal analysis and time history analysis for the obtained equivalent linear systems are conducted and compared with experimental result.

  • PDF

Nonlinear Noise-Induced Transitions in Active Rotator Model

  • Kim, Seung-Hwan;Park, Seon-Hee;Ryu, Chang-Su
    • ETRI Journal
    • /
    • v.20 no.2
    • /
    • pp.214-230
    • /
    • 1998
  • We investigate noise-induced transitions in active rotator model with a fluctuating threshold in the presence of an additive noise. The fluctuation of the threshold depends on the additive noise in a nonlinear fashion. In the white-noise limit of the fluctuation, the Fokker-Planck equation of the system reduces to that of the system with correlated linear fluctuation implying that the nonlinearity may be transformed into the correlation of linear noises. We also investigate the system with a nonlinear colored noise which depends on the additive noise as its square. The system shows a single peak, two peaks, and three peaks in its steady state probability distribution according to the noise intensities and the correlation time whose change leads to peak-creating, peak-splitting, and peak-merging transitions.

  • PDF

Dynamic Response Improvement of Stand Alone Engine-Generator System using Double Voltage Detection Method (전압 이중 검출법에 의한 독립형 엔진-발전기 시스템 응답특성 개선)

  • Lee, Dong-Hee;Ahn, Jin-Woo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.7
    • /
    • pp.1195-1199
    • /
    • 2008
  • In this paper, peak detector of generator's output voltage and variable gain controller are introduced for a fast dynamic response. The conventional r,m.s, signal detected has inherent time delay, and the dynamic response of generator using conventional PID controller has some problem in sudden load change. In this paper, the peak detector and signal selector with variable gain controller is used to overcome this problem. The main controller can check the voltage state from the peak detector. When a sudden load change, the over-voltage and under-voltage signal from peak detector change the controller's gain and exciter's current reference. The proposed scheme can improve the dynamic response, which is verified from experimental test of 200kW diesel engine-generator.

A Study on the Pulse Peak Voltage and Cascading Ratio of Compact Pulse Generator using Cascading Method (Cascading 방식을 적용한 펄스발생기의 펄스전압 변성 및 Cascading 비율 특성)

  • Joung, Jong-Han;Kim, Hee-Je
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.7
    • /
    • pp.329-333
    • /
    • 2001
  • The pulsed poser system has been widely used to many applications, such as E/P(Electrostatic Precipitator), DeNox/DeSOx power system, ozon generator, etc. A pulse energy efficiency for load depends on the rising time, peak value, pulse duration and impedance matching, etc. The pulse generator generally required for short pusle duration and high peak value was forced to consider its volume and economy. In this study, developing a compact pulse generator that applied for cascading method to be made of two pulse transformers, we compared cascading voltage with non cascading one by applying the pulse energy to load. Adopting cascading technique to pulse transformer, we found that average cascading voltage was about 60[%] of theoretical value. Maximum cascading ratio was calculated at 60 times compared with non cascading voltage.

  • PDF

The Study on the Running Test of Urban Transit Maglev (II) - Levitation System - (도시형 자기부상열차의 주행성능시험(II) - 부상시스템 -)

  • Lee, Jeong-Seok;Lee, Seo-Woo;Kim, Bong-Seop
    • Proceedings of the KIEE Conference
    • /
    • 1999.07a
    • /
    • pp.6-8
    • /
    • 1999
  • In this paper deals with running test for the UTM(Urban Transit Maglev)-01, that is test and evaluation for the maglev. We will predict about the test value for running maglev vhicle. In this time we tested rms gap fluctuation and peak to peak air gap for levitation system of UTM-01. And then we profit for the upgrade Maglev System.

  • PDF