• Title/Summary/Keyword: peak fitting

Search Result 148, Processing Time 0.034 seconds

Characterization of Thermal Degradation of Polymide 66 Composite: Relationship between Lifetime Prediction and Activation Energy (폴리아미드 66 복합소재의 열 열화 특성: 수명 예측과 활성화 에너지의 상관관계)

  • Jung, Won-Young;Weon, Jong-Il
    • Polymer(Korea)
    • /
    • v.36 no.6
    • /
    • pp.712-720
    • /
    • 2012
  • Thermal degradation for glass fiber-reinforced polyamide 66 composite (PA 66) with respect of thermal exposure time has been investigated using optical microscopy, scanning electron microscopy and Fourier transform infrared spectroscopy. As the thermal exposure time was prolonged, a slight increase in tensile strength for only initial stage and afterward, a proportional decrease of tensile strength was observed. These results can be explained by the increase of crystallinity, followed by the increase of crosslinking density, chain scission and the decrease in chain mobility, due to thermal oxidation with the exposure time. Fourier transform infrared spectroscopy results showed the increase of ketone peak and silica peak on the surface of thermally exposed PA 66. In addition, the thermal decomposition kinetics of PA 66 was analyzed using thermogravimetric analysis at three different heating rates. The relationship between activation energy and lifetime-prediction of PA 66 was investigated by several methodologies, such as statistical tool, UL 746B, Ozawa and Kissinger. The activation energy determined by thermogravimetric analysis had a relatively large value compared with that from the accelerated test. This may result in over-estimating the lifetime of PA 66. In this study, a master curve of exponential fitting has been developed to extrapolate the activation energy at various service temperatures.

Pharmacokinetics of oxytetracycline in rabbits after intravenous and intramuscular administrations (토끼에서 oxytetracycline의 정맥 및 근육 투여시의 약물동태학)

  • Kim, Eun-jung;Yun, Hyo-in;Park, Seung-chun;Oh, Tae-kwang;Cho, Chun-hyung
    • Korean Journal of Veterinary Research
    • /
    • v.34 no.2
    • /
    • pp.259-266
    • /
    • 1994
  • The study was carried out to determine the pharmacokinetic parameters after intravenous(iv) and intramuscular(im) administration (10mg/kr) in healthy rabbits. The results obtained through the experiments were summarized as follows: 1. Bioassay (Bacillus cereus 11778) was evaluated very useful for the determination of oxytetracycline(OTC) in the rabbit serum and tissues, with the detection limit of $0.125{\mu}g/ml$. 2. The pharmacokinetic profiles of OTC (10mg/kg, iv) in rabbits were best described with a two compartment open model $(C=29.5e^{-4,3t}{\pm}3.6^{-0.2t})$, whereas that of OTC (10mg/kg, im) showed a one compartment curve fitting. 3. Following iv administration, a rapid distribution phase was predominant [$t_{\frac{1}{2}}({\alpha}):1.43{\pm}0.98hr$ (♂), $0.5{\pm}0.1hr$(♀)], and then more slow elimination phase ensued [$t_{\frac{1}{2}}({\beta}):4.52{\pm}0.76hr$(♂), $7.32{\pm}2.52hr$(♀)]. Other computer generated pharmacokinetic values were as follows:C1 [$67.76{\pm}18.59ml/kg/h$(♂), $76.03{\pm}22.98ml/kg/h$ (♀)] Vd [$257.74{\pm}180.47ml/kg$ (♂), $92.33{\pm}23.62$ (♀)] AUC [$25.6{\pm}4.44mgh/L$ (♂), $39.6{\pm}12.13mgh/l$ (♀)]. There were no statistical significance between both sexes for all the parameters at the confidence level of 95%. 4. After im administaration, the absorption from the injection sites was very rapid [ Ka:$0.18{\pm}0.03h^{-1}$ (♂), $0.24{\pm}0.02h^{-1}$ (♀)] followed by a monoexponential elimination fashion. The time to peak blood level (Tmax) were calculated $1.64{\pm}0.15hr$ and $1.34{\pm}0.24hr$, in the male and female, respectively. The peak levels (Cmax) at the corresponding time were $1.69{\pm}0.23{\mu}g/ml$ (♂) and $2.08{\pm}0.16{\mu}g/ml$ (♀), with no statistical differences (p>0.05).

  • PDF

Pharmacokinetics of amoxicillin after intramuscular injection at different temperatures to cultured olive flounder, Paralichthys olivaceus (Amoxicillin의 근육투여에 따른 수온별 넙치 체내 약동학적 특성)

  • Kim, Ji-Soo;Lee, Ji-Hoon;Lee, Soo-Jin;Park, Kwan-Ha
    • Journal of fish pathology
    • /
    • v.28 no.1
    • /
    • pp.43-51
    • /
    • 2015
  • The pharmacokinetic properties and residue levels of amoxicillin (AMOX) were studied after intramuscular injection to cultured olive flounders ($100{\pm}50g$), Paralichthys olivaceus. For pharmacokinetic studies, AMOX of 20 to 80 mg/kg body weight was administered at $17{\pm}2^{\circ}C$ or $22{\pm}2^{\circ}C$ and AMOX concentrations were determined in plasma, the liver, and the kidney by HPLC-UVD. Plasma samples were assessed at 0.25, 0.5, 1, 3, 6, 12, 24, 48, 72, 96, 168 hours post-dose, whereas liver and kidney concentrations were measured at 0.25 to 48 hours post-dose. The kinetic profiles of AMOX were analyzed by fitting to a 2-compartmental model with PKSolver program. The following parameters were obtained for a single dosage of 20, 40 and 80 mg/kg of body weight at $22^{\circ}C$ and 20 and 40 mg/kg of body weight at $17^{\circ}C$ in plasma, liver and kidney, respectively: $C_{max}$ (the peak concentration)= $27.23-257.36{\mu}g/m{\ell}$, $5.49-41.65{\mu}g/g$, $16.75-129.31{\mu}g/g$; $t_{max}$ (the time for peak concentration)= 0.05-0.91, 1.36-3.28, 1.95-4.49 h. For residue studies, AMOX of 40 and 400mg/kg was administered, and muscle samples were taken at 2, 5, 7, 14 and 21 days post-dose. The residueof AMOX in the muscle were found under the MRLs (maximum residue levels) within 7 days for the two doses.

Pharmacokinetics of oxytetracycline in olive flounder (Paralichthys olivaceus) by intramuscular injection (Oxytetracycline을 근육 주사한 넙치 (Paralichthys olivaceus)의 약물동태학적 특성)

  • Jung, Sung-Hee;Choi, Dong-Lim;Kim, Jin-Woo;Jo, Mi-Ra;Seo, Jung-Soo;Ji, Bo-Young
    • Journal of fish pathology
    • /
    • v.22 no.1
    • /
    • pp.91-95
    • /
    • 2009
  • The pharmacokinetic properties of oxytetracycline (OTC) were studied after intramuscular injection to cultured olive flounder, Paralichthys olivaceus. Plasma concentrations of OTC were determined after dosage of 12.5, 25 and 50 ㎎/㎏ body weight in olive flounder (average 600 g, $23{\pm}1{^{\circ}C}$). Plasma samples were taken at 3, 5, 10, 15, 24, 32, 48, 72, 120, 168, 240 and 360 h post-dose. With 25 and 50 ㎎/㎏, the peak plasma concentrations of OTC, which attained at 5 h post-dose, were 0.99 and 1.49 $\mu{g}/m\ell$, respectively. However, the peak plasma concentration of 12.5 ㎎/㎏ was 0.35 $\mu{g}/m\ell$ after 10 h post-dose. Plasma concentrations of OTC were not measurable at 360 h post-dose in all doses. The kinetic profile of absorption, distribution and elimination of OTC in plasma were analyzed fitting to a 1-compartment model by Win-Nonlin program. The following parameters were calculated for 12.5, 25 and 50 ㎎/㎏ body weight, respectively: AUC (the area under the concentration-time curve)?D���D24.98, 44.67 and 50.45 $\mu{g}$ $h/m\ell$ $T_{1/2}$ (half-life) ?D���D0.42, 0.59 and 0.41 h; $T_{max}$ (time for maximum concentration)?D���D8.46, 6.34 and 2.66 h; $C_{max}$ (maximum concentration)?D���D0.30, 0.63 and 1.13 $\mu{g}/m\ell$.

[ $M\ddot{o}ssbauer$ ] Spectroscopy and Crystal Chemistry of Aenigmatite, $Na_4(Fe^{2+},Ti,Fe^{3+}){_{12}}(Fe^{3+},Si){_{12}}O_{40}$ (에이니그마타이트($Na_4(Fe^{2+},Ti,Fe^{3+}){_{12}}(Fe^{3+},Si){_{12}}O_{40}$)의 뫼스바우어 분광분석과 결정화학)

  • Choi, Jin-Beom
    • Journal of the Mineralogical Society of Korea
    • /
    • v.20 no.4
    • /
    • pp.367-376
    • /
    • 2007
  • Aenigmatite, $Na_4(Fe^{2+},Ti,Fe^{3+}){_{12}}(Fe^{3+},Si){_{12}}O_{40}$, is a common constituent of sodium-rich alkaline igneous rocks and is classified a an open-branched single-chain silicate. $M\ddot{o}ssbauer$ spectroscopy of three natural aenigmatite specimens were done and the detailed crystal chemistry was obtained. Fitting of $M\ddot{o}ssbauer$ spectra led to the resolution of nine peaks. They consist of three doublets of $Fe^{2+}/oct$ and one merged peak at low velocity matching to two small peaks at high velocity which were assigned to $Fe^{3+}/tet\;and\;Fe^{2+}/oct$, respectively. Using the peak area for $Fe^{2+}\;and\;Fe^{3+}$ peaks, analytical data were recalculated. Precise assignment of $Fe^{2+}\;and\;Fe^{3+}$ ions in tetrahderal and octahedral sites revealed detailed crystal chemistry of aenigmatite. The existence of significant amounts of $Fe^{3+}/tet$ indicates that $Fe^{3+}$ has preference over $Al^{3+}$ for the tetrahedral sites. Crystal chemistry of aenigmatite (AEN1) yields the formula of $(Na_{3.97}Ca_{0.03})(Ca_{0.11}Mn_{0.59}Fe^{2+}{_{8.07}}Ti_{2.07}Mg_{0.70}Fe^{3+}{_{0.43}}Al_{0.04})(Fe^{3+}{_{0.56}}Al_{0.18}Si_{11.26})O_{40}$.

Study of RF Impairments in Wideband Chirp Signal Generator (광대역 첩 신호 발생기를 위한 RF 불균형 연구)

  • Ryu, Sang-Burm;Kim, Joong-Pyo;Yang, Jeong-Hwan;Won, Young-Jin;Lee, Sang-Kon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.12
    • /
    • pp.1205-1214
    • /
    • 2013
  • Recently spaceborne SAR systems are increasing image resolution and frequency. As a high quality image resolution, the wider bandwidth is required and a wideband signal generator with RF component is very complicated and RF impairments of device is increased. Therefore, it is very important to improve performance by reducing these errors. In this study, the transmission signal of the wideband signal generator is applied to the phase noise, IQ imbalance, ripple gain, nonlinear model of high power amplifier. And we define possible structures of wideband signal generator and measure the PSLR and ISLR for the performance assesment. Also, we extract error of the amplitude and phase from the waveform and use a quadratic polynomial curve fitting and examine the performance change due to nonlinear device. Finally, we apply a high power amplifier predistortion method for non-linear error compensation. And we confirm that distortion in the output of the amplifier by intermodulation component is decreased by 15 dB.

Optical properties of diamond-like carbon films deposited by ECR-PECVD method (ECR-PECVD 방법으로 증착한 Diamond-Like carbon 박막의 광 특성)

  • Kim, Dae-Nyoun;Kim, Ki-Hong;Kim, Hye-Dong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.2
    • /
    • pp.291-299
    • /
    • 2004
  • DLC films were deposited using the ECR-PECVD method with the fixed deposition condition, such as ECR power, methane and hydrogen gas-flow rates and deposition time, for various substrate bias voltage. We have investigated the ion bombardment effect induced by the substrate bias voltage on films during the deposition of film. The characteristic of the films were analyzed using the FTIR, Raman, and UV/Vis spectroscopy analysis shows that the amount of dehydrogenation in films was increased with the increase of substrate bias voltage and films thickness was decreased. Raman scattering analysis shows that integrated intensity ratio(ID/IG) of the D and G peak was increased as the substrate bias voltage increased and films hardness was increased. Optical transmittances of DLC film were decreased with increasing deposition time and substrate bias voltage. From these results, it can be concluded that films deposited at this experimental have the enhanced characteristics of DLC because of the ion bombardment effect on films during the deposition of film.

  • PDF

A Measurement and Analysis of Thermoluminescence Spectra of LaAlO3 (LaAlO3에 대한 열자극발광 스펙트럼의 광학적 분석)

  • Lee, J.I.;Moon, J.H.;Kim, D.H.
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.4 no.2
    • /
    • pp.141-146
    • /
    • 1999
  • We measured and analyzed thermoluminescence spectra of $LaAlO_3$, single crystal by 3 dimensional data for temperature, wavelength and luminescence intensity. $LaAlO_3$, has used as the substrates of YBCO(superconductor) or semiconductors. We could determined the energy of recombination center, that is impossible through analysis of glow curve data. We could obtained the energy through analysis of the spectrum data at peak temperature by Franck-Condon model. The total glow curve was deconvoluted to three glow curves by curve fitting method. The activation energies were 0.54eV, 0.91eV and 1.02eV respectively. The energies of recombination centers were determined with 2.04eV and 2.75eV from the analysis of luminescence intensity data for wavelength.

  • PDF

Point-diffraction interferometer for 3-D profile measurement of light scattering rough surfaces (광산란 거친표면의 고정밀 삼차원 형상 측정을 위한 점회절 간섭계)

  • 김병창;이호재;김승우
    • Korean Journal of Optics and Photonics
    • /
    • v.14 no.5
    • /
    • pp.504-508
    • /
    • 2003
  • We present a new point-diffraction interferometer, which has been devised for the three-dimensional profile measurement of light scattering rough surfaces. The interferometer system has multiple sources of two-point-diffraction and a CCD camera composed of an array of two-dimensional photodetectors. Each diffraction source is an independent two-point-diffraction interferometer made of a pair of single-mode optical fibers, which are housed in a ceramic ferrule to emit two spherical wave fronts by means of diffraction at their free ends. The two spherical wave fronts then interfere with each other and subsequently generate a unique fringe pattern on the test surface. A He-Ne source provides coherent light to the two fibers through a 2${\times}$l optical coupler, and one of the fibers is elongated by use of a piezoelectric tube to produce phase shifting. The xyz coordinates of the target surface are determined by fitting the measured phase data into a global model of multilateration. Measurement has been performed for the warpage inspection of chip scale packages (CSPs) that are tape-mounted on ball grid arrays (BGAs) and backside profile of a silicon wafer in the middle of integrated-circuit fabrication process. When a diagonal profile is measured across the wafer, the maximum discrepancy turns out to be 5.6 ${\mu}{\textrm}{m}$ with a standard deviation of 1.5 ${\mu}{\textrm}{m}$.

Alternating Acquisition Technique for Quantification of in vitro Hyperpolarized [1-13C] Pyruvate Metabolism

  • Yang, Seungwook;Lee, Joonsung;Joe, Eunhae;Lee, Hansol;Song, Ho-Taek;Kim, Dong-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.20 no.1
    • /
    • pp.53-60
    • /
    • 2016
  • Purpose: To develop a technique for quantifying the $^{13}C$-metabolites by performing frequency-selective hyperpolarized $^{13}C$ magnetic resonance spectroscopy (MRS) in vitro which combines simple spectrally-selective excitation with spectrally interleaved acquisition. Methods: Numerical simulations were performed with varying noise level and $K_p$ values to compare the quantification accuracies of the proposed and the conventional methods. For in vitro experiments, a spectrally-selective excitation scheme was enabled by narrow-band radiofrequency (RF) excitation pulse implemented into a free-induction decay chemical shift imaging (FIDCSI) sequence. Experiments with LDH / NADH enzyme mixture were performed to validate the effectiveness of the proposed acquisition method. Also, a modified two-site exchange model was formulated for metabolism kinetics quantification with the proposed method. Results: From the simulation results, significant increase of the lactate peak signal to noise ratio (PSNR) was observed. Also, the quantified $K_p$ value from the dynamic curves were more accurate in the case of the proposed acquisition method compared to the conventional non-selective excitation scheme. In vitro experiment results were in good agreement with the simulation results, also displaying increased PSNR for lactate. Fitting results using the modified two-site exchange model also showed expected results in agreement with the simulations. Conclusion: A method for accurate quantification of hyperpolarized pyruvate and the downstream product focused on in vitro experiment was described. By using a narrow-band RF excitation pulse with alternating acquisition, different resonances were selectively excited with a different flip angle for increased PSNR while the hyperpolarized magnetization of the substrate can be minimally perturbed with a low flip angle. Baseline signals from neighboring resonances can be effectively suppressed to accurately quantify the metabolism kinetics.