• 제목/요약/키워드: peak external pressure

검색결과 37건 처리시간 0.024초

선체의 변형을 감지하기 위한 새로운 형태의 장주기 광섬유 격자 소자 (Novel Long-period Fiber Grating devices for Monitoring the Deformation of Ship Hull)

  • 손경락
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제31권6호
    • /
    • pp.761-767
    • /
    • 2007
  • We have developed novel optical-fiber sensors based on strain-induced long-period fiber gratings for monitoring the deformation of a hull. They have no external pressure for sustaining the mechanical formed gratings. The pressure, which provides a force to form the periodic grating along the single mode fiber, was realized by the bonding strength of a photopolymer. To reduce the polarization dependency of the sensors caused by the asymmetry structure of gratings, a Faraday Rotator Mirror (FRM) was utilized in this experiment. We have realized the polarization-insensitive function of the proposed sensors. The change of an external strain are measured by an optical spectrum analyzer. When the external stain increases. the attenuation at the resonant wavelength decreases and the loss peak was slightly shifted to the shorter wavelength.

Linearized analysis of the internal pressures for a two-compartment building with leakage

  • Yu, Xianfeng;Gu, Ming;Xie, Zhuangning
    • Wind and Structures
    • /
    • 제28권2호
    • /
    • pp.89-97
    • /
    • 2019
  • The non-linear equations governing wind-induced internal pressures for a two-compartment building with background leakage are linearized based on some reasonable assumptions. The explicit admittance functions for both building compartments are derived, and the equivalent damping coefficients of the coupling internal pressure system are iteratively obtained. The RMS values of the internal pressure coefficients calculated from the non-linear equations and linearized equations are compared. Results indicate that the linearized equations generally have good calculation precision when the porosity ratio is less than 20%. Parameters are analyzed on the explicit admittance functions. Results show that the peaks of the internal pressure in the compartment without an external opening (Compartment 2) are higher than that in the compartment with an external opening (Compartment 1) at lower Helmholtz frequency. By contrast, the resonance peak of the internal pressure in compartment 2 is lower than that in compartment 1 at higher Helmholtz frequencies.

쌍곡선포물선 대공간 구조물의 측벽개구율에 따른 지붕의 풍압특성 (Characteristic of Wind Pressure Distribution on the Roof of Hyperbolic Paraboloid Spatial Structures)

  • 유장열;유기표
    • 한국공간구조학회논문집
    • /
    • 제13권1호
    • /
    • pp.51-57
    • /
    • 2013
  • There can be diverse causes in the destruction of a large space structure by strong wind such as characteristics of construction materials and changes in internal and external wind pressure of the structure. To evaluate the wind pressure of roof against the large space structure, wind pressure experiment is performed. However, in this wind pressure experiment, peak internal pressure coefficient is set according to the opening of the roof in Korea wind code. In this article, it was tried to identify the change of internal pressure coefficient and the characteristics of wind pressure coefficient acting on the roof by two kinds of opening on the side of the structure with Hyperbolic Paraboloid Spatial Structures roof. When analyzing internal pressure coefficient according to roof shape, it was found that minimum (52%) and maximum (30%~80%) overestimation was made comparing to partial opening type proposed in the current wind load. It is judged that evaluation according to the opening rate of the structure should be made to evaluate the internal pressure coefficient according to load.

Auto-PEEP이 존재하는 환자에서 호흡 일에 대한 External PEEP의 효과 (The Effect of External PEEP on Work of Breathing in Patients with Auto-PEEP)

  • 진재용;임채만;고윤석;박평환;최종무;이상도;김우성;김동순;김원동
    • Tuberculosis and Respiratory Diseases
    • /
    • 제43권2호
    • /
    • pp.201-209
    • /
    • 1996
  • 연구배경: Auto-PEEP 혹은 intrinsic PEEP은 호기말에 폐용적이 전체 호흡기계의 이완 용적으로 돌아오지 않음으로써, 증가된 호흡기계의 탄성반도압만큼 호기말 폐포내압(alveolar pressure) 이양의 값을 보이는 것을 말한다. Auto-PEEP 이 존재하는 만성폐쇄성폐질환 환자에게 externa1 PEEP을 적용하면 환자의 호흡 일을 줄일 수 있어서, 질환의 급성악화시 혹은 기계호흡으로부터의 이탈시 환자의 자발호흡을 보조하기 위한 요법으로 제시되고 있다. 이에 기계호흡중인 환자에서 auto-PEEP의 존재가 호흡 일에 미치는 영향을 알아보고, externa1 PEEP의 사용이 auto- PEEP에 의해 증가된 호흡 일을 줄이는지를 알아보기 위해 본 연구를 시행하였다. 방법: 호흡부전으로 기계호흡을 하고 있는 환자 15명을 대상으로 연구가 이루어 졌으며, 이들 7명에서 auto-PEEP이 관찰되었고(auto-PPEP군) 8명에서 auto-PEEP이 auto-PEEP군). 양군 간의 환자의 호흡역학적 지표의 차이를 조사하였으며, auto-PEEP이 존재하는 환자들에 대해 3cm $H_2O$의 external PEEP을 적용한 뒤 호흡역학적 지표들의 변화를 조사하였다. 호흡역학적 지표는 상시호흡량(tidal volume, 이하 $V_T$), 분당 호흡수, 분당환기량 (minute ventilation 이하 $V_E$), 최고흡기유량(peak inspiratory flow rate, 이하 PIFR), 최고호기유행peak expiratory flow rate, 이하 PEFR), 최고흡기압(peak inspiratory pressure, 이하 PIP), $T_I/T_{TOT}$, auto-PEEP, 폐 동적탄성 (dynamic compliance of lung, 이하 Cdyn), 호기 기도저항(expiratory airway resistance, 이하 RAWe), 평균 기도저항(mean airway resistance, 이하 RAWm), $P_{0.1}$, 환자에 의해 수행되는 호흡 일 (work of breathing performed by patient, 이하 호흡 일), pressure-time product(이하 PTP)등이었다.

  • PDF

Internal pressure dynamics of a leaky and quasi-statically flexible building with a dominant opening

  • Guha, T.K.;Sharma, R.N.;Richards, P.J.
    • Wind and Structures
    • /
    • 제16권1호
    • /
    • pp.61-91
    • /
    • 2013
  • An analytical model of internal pressure response of a leaky and quasi-statically flexible building with a dominant opening is provided by including the effect of the envelope external pressure fluctuations on the roof, in addition to the fluctuating external pressure at the dominant opening. Wind tunnel experiments involving a flexible roof and different building porosities were carried out to validate the analytical predictions. While the effect of envelope flexibility is shown to lower the Helmholtz frequency of the building volume-opening combination, the lowering of the resonant peak in the internal and net roof pressure coefficient spectra is attributed to the increased damping in the system due to inherent background leakage and envelope flexibility. The extent of the damping effects of "skin" flexibility and background leakage in moderating the internal and net pressure response under high wind conditions is quantified using the linearized admittance functions developed. Analytical examples provided for different combinations of background leakage and envelope flexibility show that alleviation of internal and net pressure fluctuations due to these factors by as much as 40 and 15% respectively is possible compared to that for a nominally sealed rigid building of the same internal volume and opening size.

A study of aerodynamic pressures on elevated houses

  • Abdelfatah, Nourhan;Elawady, Amal;Irwin, Peter;Chowdhury, Arindam
    • Wind and Structures
    • /
    • 제31권4호
    • /
    • pp.335-350
    • /
    • 2020
  • In coastal residential communities, especially along the coastline, flooding is a frequent natural hazard that impacts the area. To reduce the adverse effects of flooding, it is recommended to elevate coastal buildings to a certain safe level. However, post storm damage assessment has revealed severe damages sustained by elevated buildings' components such as roofs, walls, and floors. By elevating a structure and creating air gap underneath the floor, the wind velocity increases and the aerodynamics change. This results in varying wind loading and pressure distribution that are different from their slab on grade counterparts. To fill the current knowledge gap, a large-scale aerodynamic wind testing was conducted at the Wall of Wind experimental facility to evaluate the wind pressure distribution over the surfaces of a low-rise gable roof single-story elevated house. The study considered three different stilt heights. This paper presents the observed changes in local and area averaged peak pressure coefficients for the building surfaces of the studied cases. The aerodynamics of the elevated structures are explained. Comparisons are done with ASCE 7-16 and AS/NZS 1170.2 wind loading standards. For the floor surface, the study suggests a wind pressure zoning and pressure coefficients for each stilt height.

Characteristics of wind loads on roof cladding and fixings

  • Ginger, J.D.
    • Wind and Structures
    • /
    • 제4권1호
    • /
    • pp.73-84
    • /
    • 2001
  • Analysis of pressures measured on the roof of the full-scale Texas Tech building and a 1/50 scale model of a typical house showed that the pressure fluctuations on cladding fastener and cladding-truss connection tributary areas have similar characteristics. The probability density functions of pressure fluctuations on these areas are negatively skewed from Gaussian, with pressure peak factors less than -5.5. The fluctuating pressure energy is mostly contained at full-scale frequencies of up to about 0.6 Hz. Pressure coefficients, $C_p$ and local pressure factors, $K_l$ given in the Australian wind load standard AS1170.2 are generally satisfactory, except for some small cladding fastener tributary areas near the edges.

Field studies of wind induced internal pressure in a warehouse with a dominant opening

  • Guha, T.K.;Sharma, R.N.;Richards, P.J.
    • Wind and Structures
    • /
    • 제16권1호
    • /
    • pp.117-136
    • /
    • 2013
  • A field study of wind-induced internal pressures in a flexible and porous industrial warehouse with a single dominant opening, of various sizes for a range of moderate wind speeds and directions, is reported in this paper. Comparatively weak resonance of internal pressure for oblique windward opening situations, and hardly discernible at other wind directions, is attributed to the inherent leakage and flexibility in the envelope of the building in addition to the moderate wind speeds encountered during the tests. The measured internal pressures agree well with the theoretical predictions obtained by numerically simulating the analytical model of internal pressure for a porous and flexible building with a dominant opening. Ratios of the RMS and peak internal to opening external pressures obtained in the study are presented in a non-dimensional format along with other published full scale measurements and compared with the non-dimensional design equation proposed in recent literature.

유압 실린더의 쿠션특성에 관한 실험적 연구 (An Experimental Study on the Cushion Characteristics of Hydraulic Cylinder)

  • 이상기;김동수;김형의
    • 기계와재료
    • /
    • 제11권2호통권40호
    • /
    • pp.53-61
    • /
    • 1999
  • The paper describes a characteristics analysis for cushion pressure and cushion stroke time at hydraulic cushioning cylinder. In hydraulic cushioning cylinder, an inertia exaggerates a kinetic energy at a reciprocation that collide with an end of stroke and generate a destructive shock, noise and vibration within the structural and operating member of machine of equipment. In order to reduce which cause to undesirable noise, vibration and fatigue in hydraulic control system, it is indispensible measure a cushion parameters at cushion region of hydraulic cushioning cylinder. A cushioning device is applied to absorb high impact energy and to decelerate a fast travelling object, too. At an experimental results, it turns out that cushion pressure is mainly a function of the external load and cylinder input flowrate rather than the supply pressure.

  • PDF

롤러 프로파일링을 고려한 박용 디젤기관 캠-롤러사이의 탄성유체윤활해석 (Elastohydrodynamic Lubrication Analysis on the Cam-Roller for a Marine Diesel Engine with Consideration of Roller Profiling)

  • 구영필;조용주
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제24권6호
    • /
    • pp.147-154
    • /
    • 2000
  • A numerical procedure to analyze 3-dimensional elastohydrodynamic lubrication was applied on the cam-roller contact of the valve mechanism for a marine diesel engine. Both the pressure distribution and the film thickness between the cam and roller follower were calculated for each time step of the whole cycle. The pressure spike is shown at the outlet of the roller edge and it is getting higher as the external load is increased. An effective profiling method for the roller edge was suggested using the results of elastohydrodynamic lubrication analysis and the peak pressure was removed completely with the new profiling.

  • PDF