• 제목/요약/키워드: peak detection

검색결과 944건 처리시간 0.028초

뒤집힌 촉매수소 전류 봉우리를 이용한 로듐의 정량 (Determination of Rhodium by Inverted Catalytic Hydrogen peak as Analytical peak)

  • 권영순;임경희
    • 분석과학
    • /
    • 제16권4호
    • /
    • pp.269-276
    • /
    • 2003
  • 새로운 종류의 벗김전압전류법, 즉 전도된 촉매 벗김전압전류법 ($IC_tSV$)을 소개한다. 염산 용액에서 로듐-포름알데히드 착물은 역주사 동안에 환원전류 봉우리 즉 전도된 촉매수소 봉우리가 생긴다. 이 전도된 봉우리의 특징을 조사하고 이 봉우리를 분석 봉우리로 이용하여 결정한 검출한계는 $1.2{\times}10^{-10}M$ (축적시간 50초)이었다. 최적 실험 조건은 0.015% (W/V) HCHO-0.42 M HCl, 농축전위 -1.1 V, 주사속도 100 mV/s이다.

Sharpness-aware Evaluation Methodology for Haze-removal Processing in Automotive Systems

  • Hwang, Seokha;Lee, Youngjoo
    • IEIE Transactions on Smart Processing and Computing
    • /
    • 제5권6호
    • /
    • pp.390-394
    • /
    • 2016
  • This paper presents a new comparison method for haze-removal algorithms in next-generation automotive systems. Compared to previous peak signal-to-noise ratio-based comparisons, which measure similarity, the proposed modulation transfer function-based method checks sharpness to select a more suitable haze-removal algorithm for lane detection. Among the practical filtering schemes used for a haze-removal algorithm, experimental results show that Gaussian filtering effectively preserves the sharpness of road images, enhancing lane detection accuracy.

인가신호 제거를 이용한 STDR의 케이블 고장 검출 성능 향상 (Cable Fault Detection Improvement of STDR Using Reference Signal Elimination)

  • 전정채;김택희
    • 한국산학기술학회논문지
    • /
    • 제17권3호
    • /
    • pp.450-456
    • /
    • 2016
  • 케이블에 인가되는 신호로 의사잡음 수열을 사용하여 인가신호와 반사신호의 시간 상관 분석을 실시하여 케이블 고장을 검출하는 STDR (sequence time domain reflectometry)은 노이즈 환경에 강하고, 단선, 합선을 포함한 간헐적 고장의 검출이 가능한 것으로 알려져 있다. 하지만 고장 위치의 거리가 멀거나 경미한 고장의 경우 반사신호의 감쇄가 크고 상관계수가 작아지게 되어, 케이블 고장 판별이 어렵거나 측정 거리 오차가 커진다. 또한 위상과 피크치 검출에 의한 고장 탐지 자동화가 어렵게 된다. 따라서 본 논문에서는 기존의 STDR의 고장 검출 성능을 향상시키기 위해 케이블에 인가되는 인가신호의 상관계수의 최댓값을 검출하고, 다음으로 인가신호를 제거하여 반사신호의 상관계수의 최댓값을 검출하는 알고리즘을 제안하였다. 제안된 방법은 저압 전력 케이블에서의 고장 검출 실험을 통해 성능을 입증하였다. 그 결과 제안된 방법은 신호가 감쇄되더라도 전통적인 STDR보다 고장 여부의 정확한 구분과 위치의 추적이 가능하였다. 또한 기준신호 제거와 상관계수의 정규화를 통해 위상과 최대값 검출 방법을 사용함으로써 자동 고장 판별과 거리 계산에 오류가 발생하지 않았다.

적응형 문턱치와 QRS피크 변화에 따른 P파 검출 알고리즘 (P Wave Detection Algorithm through Adaptive Threshold and QRS Peak Variability)

  • 조익성;김주만;이완직;권혁숭
    • 한국정보통신학회논문지
    • /
    • 제20권8호
    • /
    • pp.1587-1595
    • /
    • 2016
  • P파는 심장의 전기적, 생리적 특성을 나타내는 파라미터로써 심방성 부정맥 진단에 있어 매우 중요하다. 하지만 R파에 비해 신호의 크기가 작고 그 형태가 다양하여 검출에 많은 어려움이 있다. P 파를 검출하기 위한 기존 연구방법으로는 주파수 분석과 비선형 접근방법 등이 제안되어 왔지만 방실 차단과 같은 전도 이상이나 심방성 부정맥의 경우에는 검출 정확도가 낮아진다. 이는 심장 상태에 따라 다양한 모양의 P파의 패턴이 존재하기 때문이다. 본 연구에서는 QRS 피크 변화에 따른 P파의 패턴을 분류하고 적응형 문턱치를 이용하여 P파를 검출하는 방법을 제안한다. 이를 위해 전처리를 통해 잡음이 제거된 심전도 신호에서 Q, R, S를 검출한다. 이후 피크 변화에 따른 P파의 3가지 패턴을 분류하고 적응형 윈도우와 문턱치를 통해 P파를 검출하였다. 제안한 방법의 우수성을 입증하기 위해 MIT-BIH 부정맥 데이터베이스 48개의 레코드를 대상으로 한 P파의 평균 검출율은 92.60%의 성능을 나타내었다.

감마선 스펙트럼 비율을 이용한 매립 선원의 깊이 평가 방법론 개발 연구 (Study on Development of Embedded Source Depth Assessment Method Using Gamma Spectrum Ratio)

  • 김준하;정재학;홍상범;서범경;이병채
    • 방사성폐기물학회지
    • /
    • 제18권1호
    • /
    • pp.51-62
    • /
    • 2020
  • 본 연구는 감마스펙트럼 비율을 이용한 매립된 선원의 깊이 평가방법 개발 및 적용성 확인을 위해 진행되었다. 이를 위해 현장측정 HPGe 계측기 및 MCNP 전산모사를 이용하여 137Cs, 60Co, 152Eu 선원의 매질 내 깊이와 계측거리에 따른 Peak to Compton, Peak to Valley 비율(Q)의 변화를 평가하였다. 해당 결과를 이용해 계측거리 50 cm를 기준으로 PTV 및 PTC 비율(Q)과 매립 선원의 깊이 간의 상관 식을 도출하였다. 그리고 PTC 및 PTV 방법 이용 시 계측거리 변화에 따른 민감도를 평가한 결과, 50 cm 기준으로 계측거리가 20 cm로 감소할 경우 오차가 3 ~ 4 cm까지 증가하였다. 하지만 100 cm로 증가할 경우 계측거리에 의한 영향이 미미함을 확인하였다. 그리고 PTV 및 PTC 방법과 피크 영역의 계수율 변화를 통해 선원의 깊이를 평가하는 Two distance measurement 방법을 상호 비교하였다. 평가 결과 PTV 및 PTC 방법은 최대 1.87 cm의 오차, Two distance measurement 방법은 최대 2.69 cm의 오차를 나타내어 PTV, PTC 방법의 정확도가 비교적 높음을 확인하였다. 선원의 수평 방향 위치 변화 민감도 평가 결과 Two distance measurement 방법은 선원이 off-center 방향으로 30 cm 이동하였을 경우 최대 오차가 25.59 cm로 나타났다. 반면 PTV 및 PTC 방법은 최대 오차 8.04 cm로 현장 적용 시 높은 정확도를 나타낼 것으로 예상된다. 그리고 PTC 방법은 동일 시간 측정 시 다른 방법과 비교하여 낮은 표준편차를 나타내 신속한 평가가 가능할 것으로 기대된다.

Nanoplasmonic Spectroscopic Imaging and Molecular Probes

  • 최연호
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.85-85
    • /
    • 2013
  • Label-free, sensitive and selective detection methods with high spatial resolution are critically required for future applications in chemical sensor, biological sensor, and nanospectroscopic imaging. Here I describe the development of Plasmon Resonance Energy Transfer (PRET)-based molecular imaging in living cells as the first demonstration of intracellular imaging with PRET-based nanospectroscopy. In-vivo PRET imaging relied on the overlap between plasmon resonance frequency of gold nanoplasmonic probe (GNP) and absorption peak frequencies of conjugated molecules, which leads to create 'quantized quenching dips' in Rayleigh scattering spectrum of GNP. The position of these dips exactly matched with the absorption peaks of target molecules. As another innovative application of PRET, I present a highly selective and sensitive detection of metal ions by creating conjugated metal-ligand complexes on a single GNP. In addition to conferring high spatial resolution due to the small size of the metal ion probes (50 nm in diameter), this method is 100 to 1,000 folds more sensitive than organic reporter-based methods. Moreover, this technique achieves high selectivity due to the selective formation of Cu2+complexes and selective resonant quenching of GNP by the conjugated complexes. Since many metal ion ligand complexes generate new absorption peak due to the d-d transition in the metal ligand complex when a specific metal ion is inserted into the complex, we can match with the scattering frequency of nanoplasmonic metal ligand systems and the new absorption peak.

  • PDF

Fully Analog ECG Baseline Wander Tracking and Removal Circuitry using HPF Based R-peak Detection and Quadratic Interpolation

  • Nazari, Masoud;Rajeoni, Alireza Bagheri;Lee, Kye-Shin
    • Journal of Multimedia Information System
    • /
    • 제7권3호
    • /
    • pp.231-238
    • /
    • 2020
  • This work presents a fully analog baseline wander tracking and removal circuitry using high-pass filter (HPF) based R-peak detection and quadratic interpolation that does not require digital post processing, thus suitable for compact and low power long-term ECG monitoring devices. The proposed method can effectively track and remove baseline wander in ECG waveforms corrupted by various motion artifacts, whereas minimizing the loss of essential features including the QRS-Complex. The key component for tracking the baseline wander is down sampling the moving average of the corrupted ECG waveform followed by quadratic interpolation, where the R-peak samples that distort the baseline tracking are excluded from the moving average by using a HPF based approach. The proposed circuit is designed using CMOS 0.18-㎛ technology (1.8V supply) with power consumption of 19.1 ㎼ and estimated area of 15.5 ㎟ using a 4th order HPF and quadratic interpolation. Results show SNR improvement of 10 dB after removing the baseline wander from the corrupted ECG waveform.

유비쿼터스 헬스케어 시스템을 위한 노드기반의 R피크 검출 알고리즘 (R-peak Detection Algorithm in Wireless Sensor Node for Ubiquitous Healthcare Application)

  • 이대석;황기현;차경환
    • 한국정보통신학회논문지
    • /
    • 제15권1호
    • /
    • pp.227-232
    • /
    • 2011
  • 현재 무선센서노드 기반의 헬스케어 모니터링 시스템이 활발히 연구되고 있다. 하지만 생체신호의 모니터링을 위한 전체 데이터의 전달은 무선센서네트워크 내의 데이터 트래픽과 에너지 소모가 증가하게 된다. 본 연구에서는 경량의 전처리 과정 및 알고리즘을 통해 ECG신호에서 의미있는 파라미터만을 검출하여 전송하였다. 본 연구에서는 정상적인 ECG에서 무선센서노드에서 R피크, RR간격을 검출할 수 있는 TinyOS 기반 어플리케이션을 구현하였으며 결과로 dECG, R피크, RR간격, HRV를 그래프로 확인 할 수 있었다. 따라서 본 연구를 이용하면 ECG신호 전체 데이터가 아닌 주요 정보만을 보냄으로서 에너지 소모, 데이터량을 줄일 수 있다.

에너지절약형 주택에서의 단열차양 적용과 제어방법에 따른 냉난방부하 분석 (An Analysis of Heating and Cooling Loads by Insulated Shades and Control Method in an Energy Saving Apartment)

  • 권경우;원종서
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.33-38
    • /
    • 2009
  • Energy loss from windows accounts for large scores of heating and cooling loads also in energy saving apartments that is reduced over 30% of total energy consumption. Movable reflective insulations, insulation shutters, blinds, insulated shades are used to reduce energy loads from windows. In this study, energy saving performance of insulated shades was simulated by control methods. According to installation of insulated shades, heating loads were decreased about $10.5{\sim}11.3%$, and cooling loads are decreased about $11.0{\sim}15.5%$ on an energy saving apartment. The heating peak load was reduced about 9.5% by insulated shades, but the cooling peak load is hardly ever decreased. Because in the condition of cooling peak load, latent cooling loads accounts for large score of cooling loads. Difference of the energy loads by a schedule control method and an outdoor detection control was no more than 5% for a base model. In the case of insulated shades with automatic control system, simple time schedule control system would be more efficient than outdoor detection control system that should use several sensors.

  • PDF

초음파 탐상을 위한 고속 아날로그 입력 카드의 설계 (Design of High Speed Analog Input Card for Ultrasonic Testing)

  • 이병수;이동원;박두석
    • 한국컴퓨터정보학회논문지
    • /
    • 제5권4호
    • /
    • pp.62-68
    • /
    • 2000
  • A/D Board는 Data Acquisition 시스템에서 가장 중요한 하드웨어 기술로써, 컴퓨터를 이용하는 계측기기에 필수적으로 사용되는 장치이다. 특히, 초음파 탐상 장치의 A/D Board는 수 MHz대의 초음파를 디지털로 변환하기 위해 고속의 A/D 변환기가 필요하고, PC 메모리로 직접 전송할 수 있는 DMA 방식의 회로 설계가 요구된다. 본 연구는 측정하려는 대상으로부터 반사된 초음파 신호를 고속의 A/D 변환기에 의해 디지털화 한 후, 데이터의 Peak값을 추출하여 ISA Bus를 통해서 PC로 전송 지켜주는 카드를 설계하였다. 초음파 탐상에 사용되는 주파수가 보통 10MHz 이상이므로 이 신호를 안정적으로 획득하기 위해서는 샘플링 속도가 초음파 주파수 보다 굇배 이상 빨라야 한다. 따라서 50MHz의 샘플링 속도와 8 비트의 분해능을 갖는 A/D 변환기를 사용하였으며, 변환된 초음파 신호를 고속 처리하기 위해 Positive와 Negative Peak Detection 모드를 동시에 동작하도록 VHDL을 이용하여 설계하였다.

  • PDF