• 제목/요약/키워드: peak current

검색결과 1,752건 처리시간 0.038초

Low Voltage-Driven CNT Cathode and It's Applications

  • Lee, Chun-Gyoo;Lee, Sang-Jo;Cho, Sung-Hee;Chi, Eung-Joon;Lee, Byung-Gon;Jeon, Sang-Ho;Ahn, Sang-Hyuck;Hong, Su-Bong;Choe, Deok-Hyeon
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2004년도 Asia Display / IMID 04
    • /
    • pp.851-854
    • /
    • 2004
  • By approaching the counter electrode to the CNT emitter, remarkable reduction of the cathode operating voltage has been accomplished in the under-gate CNT cathode structure. The peak emission current density of 2.5 ms/$cm^2$, which is sufficient for high brightness CNT field emission display, was obtained at the cathode-to-gate voltage of 57 V when the CNT-to-counter electrode gap was 2.2 ${\mu}m$. The gate current was less than 10 % of the anode current. The CNT cathode with low driving voltage can help the cost-effective field emission display implemented.

  • PDF

A Maximum Power Point Tracking Control for Photovoltaic Array without Voltage Sensor

  • Senjyu Tomonobu;Shirasawa Tomiyuki;Uezato Katsumi
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.617-621
    • /
    • 2001
  • This paper presents a maximum power point tracking algorithm for Photovoltaic array using only instantaneous output current information. The conventional Hill climbing method of peak power tracking has a disadvantage of oscillations about the maximum power point. To overcome this problem, we have developed a algorithm, that will estimate the duty ratio corresponding to maximum power operation of solar cell. The estimation of the optimal duty ratio involves, finding the duty ratio at which integral value of output current is maximum. For the estimation, we have used the well know Lagrange's interpolation method. This method can track maximum power point quickly even for changing solar insolations and avoids oscillations after reaching the maximum power point.

  • PDF

멀티레이트 신호처리와 동적 래이턴스 보정에 의한 단일 응답 유발전위 뇌파 추출 (Estimation of single-trial event-related potentials using multirate signal processing latency compensation)

  • 이용희;이두수
    • 전자공학회논문지S
    • /
    • 제34S권12호
    • /
    • pp.60-69
    • /
    • 1997
  • We present an average method based on the multirate signal processing and dynamic allocation average for the purpose of monitoring event-related potentials(ERP) and continuously and dynamically. In the proposed method, first, latency shifts are detected through the cross correlation between a current response and the reference response. Then, the multirate signal processing which is composed of up-sampler, lowpass filter, and down sampler is performed to compensate the latency shifts of the reference response, therefore we obtain the reference response with a peak latencies compenated by those of a current response. Finally, the single response is obtained by averaging the compensated reference response and a current response. In the simulation, the results of quantitative evaluation by simulation and the results using linical data are presented. From the result, the proposed method reflects dynamic time-varying ERP more exactly than previous methods and is also effective in consecutive monitoring of ERP.

  • PDF

MAG용접의 Arc안정성에 미치는 Si의 영향 (Effect of Si on Arc Stability of MAG Welding)

  • 안영호;이종봉;엄동석
    • Journal of Welding and Joining
    • /
    • 제16권6호
    • /
    • pp.52-58
    • /
    • 1998
  • The effect of Si content in welding wires on th arc stability was investigate, in the region of short circuit transfer and spray transfer. In the region of short circuit transfer, with increasing Si content, average arcing time and average short circuit time were increased. Therefore, droplet transfer frequency was decreased, due to the increase of arcing time and peak current at the moment of arc-reiginition was increased, due to the increase of short circuit time. In the region of spray transfer, the fluctuations of arc current and arc voltage was the most stable in wire with Si content of about 00.60 wt.%.

  • PDF

포화자성체 코어를 이용한 직교류 저전류측정장치 (AC/DC low current measurement system using the saturable magnetic cores)

  • 박영태;장석명;이용대
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.620-622
    • /
    • 2001
  • 자성체 코어의 비선형 특성을 이용하여 DC와 AC 전류를 측정하는 Zero-Flux Current Transformer는 정밀 전류 측정용으로 많이 연구되고 있다. Zero-Flux Current Transformer는 DC 대전류 측정에 합당하며 저 전류 측정에 사용될 경우 소모전류, 안정되고 첨예한 필터 제작, magnetic modulator에 의한 zero point drift, 자화 전류가 비대칭일 때 출력 등과 같은 문제가 해결되어야 한다. 그리고 상용으로 사용하기 위하여 Hand-Held Type으로 제작되어야하며 동작시의 소모전류가 작고 정확도가 우수하여야 한다. 본 연구에서는 자화 전류가 비대칭일 때 출력을 zero로 만들기 위하여 사용하는 필터와 복잡한 회로로 구성된 magnetic modulator 부분을 여러개의 peak detector를 사용하여 AC와 DC를 측정하는 클램프미터를 개발하였으며 그 특성에 대한 내용을 기술하였다.

  • PDF

AlGaAs/GaAs 단일양자 우물 구조에서 Airy 함수를 이용한 공명터널링 현상에 관한 고찰 (Analysis of the Resonant Tunneling in an AlGaAs/GaAs Single Quantum Well Structure by an Airy Function Approach)

  • 김성진;이경윤;이헌용;성영권
    • 전자공학회논문지A
    • /
    • 제29A권1호
    • /
    • pp.19-24
    • /
    • 1992
  • The analysis of the resonant tunneling based on the exact solution of Schrodinger equations is performed in a single quantum well structure under applied bias. The transmittivity and the net tunneling current density are calculated with Airy function and the boundary conditions which is suggested by Bastard. The results are compared with those from other methods and boundary conditions. From the calculated J-V characteristics for the tunneling current, the dependence of the voltage location showing the first peak current on the various temperatures and Fermi level is investigated. In addition, the wave function within the structure is obtained and compared with that from the flat-potential model.

  • PDF

Comparison with Polarization Characteristic of Polymers

  • Choi, Chil-Nam;Yabg, Hyo-Kyung
    • 한국환경과학회:학술대회논문집
    • /
    • 한국환경과학회 2001년도 가을 학술발표회 발표논문집
    • /
    • pp.188-190
    • /
    • 2001
  • We carried out to measure the variations of potential with current density polymers. The results were particularly examined to identify the influences on corrosion potential and corrosion rate of various factors including temperature and pH. The Tafel slope for anodic dissolution was determined by the polarization effect depending on these conditions. The optimum conditions were established for each case. The second anodic current density peak and maximum passive current density were designated as the relative corrosion sensitivity($I_{r}I_{f}$). The mass transfer coefficient value (${\alpha}$) was determined with the Tafel slope for anodic dissolution based on the polarization effect with optimum conditions.

  • PDF

Time Varying 전원 전압을 고려한 PWM 컨버터 제어 (PWM Converter Control considering time varying source voltage)

  • 주인원;임선경;남광희
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.692-695
    • /
    • 1999
  • A new control scheme is proposed suitable for the three phase PWM converter having abrupt load variation such as a crane. In the converter used in a crane, the peak value of source voltage varies instantaneously due to the abrupt load variations. Such a voltage variation degrades the performance of DC-link control of PWM converter. To overcome this problem, load variations should be detected and compensated properly. We propose a new method for detecting and compensating the load variations without the additional hardware. With the proposed scheme, load variations are detected by estimating the current of DC-link capacitor. The estimated current information is feedbacked to a current controller to improve the performance. Additionally, the variation of source voltage is compensated using feedforward controller. The performance of the proposed scheme has been verified through simulations.

  • PDF

Signal Analysis of Motor Current for End Point Detection in the Chemical Mechanical Polishing of Shallow Trench Isolation with Reverse Moat Structure

  • Park, Chang-Jun;Kim, Sang-Yong;Seo, Yong-Jin
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제2C권5호
    • /
    • pp.262-267
    • /
    • 2002
  • In this paper, we first studied the factors affecting the motor current (MC) signal, which was strongly affected by the systematic hardware noises depending on polishing such as pad conditioning and arm oscillation of platen and recipe, head motor. Next, we studied the end point detection (EPD) for the chemical mechanical polishing (CMP) process of shallow trench isolation (STI) with reverse moat structure. The MC signal showed a high amplitude peak in the fore part caused by the reverse meal. pattern. We also found that the EP could not be detected properly and reproducibly due to the pad conditioning effect, especially when conventional low selectivity slurry was used. Even when there was no pad conditioning effect, the EPD method could not be applied, since the measured end points were always the same due to the characteristics of the reverse moat structure with an open nitride layer.

싸이리스터 컨버터부하를 가지는 병렬형 능동전력필터 용량에 관한 연구 (A Study on the capacity of shunt type active power filter with a thyristor converter load)

  • 박노중;정숭기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 F
    • /
    • pp.2470-2474
    • /
    • 1999
  • The main drawback of parallel type active power filters (APFs) is the large capacity required for harmonic compensation. This paper evaluates the APF capacity requirement for harmonic/reactive power compensation for thyristor converter load. Theoretically achievable maximum power factor under partial load is evaluated. it is shown that the APF capacity can be considerably reduced by deliberately limiting the peak current, while maintaining the filtering performance with an acceptable total harmonic current level. the minimum capacity requirement of APF with current limiting is evaluated as a function of the firing angle of thyristor converter and short circuit ratio(SCR).

  • PDF