• Title/Summary/Keyword: peak current

Search Result 1,752, Processing Time 0.035 seconds

The Effects of Isokinetic Exercise on Knee Joint Combined Russian Current Stimulation

  • Kim, Dong-Hoon;Jung, Ho-Bal
    • The Journal of Korean Physical Therapy
    • /
    • v.27 no.5
    • /
    • pp.351-355
    • /
    • 2015
  • Purpose: This study was conducted to determine how stimulation using Russian current changes isokinetic exercise performance of quadriceps muscle and its antagonist muscles. Methods: Subjects were 20 20-year-old healthy adults who were instructed in the flexion to extension of knees in angular velocity $60^{\circ}/sec$ and $180^{\circ}/sec$ using a Biodex (Biodex system 3). We measured the difference in muscle performance between the Russian current stimulated at the same time during the flexion to extension of knees and not stimulated. Results: The results showed that when Russian current stimulation was applied at the angular velocity $60^{\circ}/sec$, the flexed and extended muscles and the angular velocity $180^{\circ}/sec$ increased significantly, but the peak torque of flexing muscles at the angular velocity $180^{\circ}/sec$ did not increase. Conclusion: These findings suggest that Russian current stimulation with isokinetic exercise of the knee joint could affect the quadriceps muscle and its antagonist muscle performance of muscle strength and endurance.

The effect electrolysis conditiong on the composition and the preferred orientation of Co-Fe-Cr alloy electrodeposits (Co-Fe-Cr 합금도금층의 조성 및 우선방위에 미치는 전해조건의 영향)

  • 예길촌;문근호
    • Journal of the Korean institute of surface engineering
    • /
    • v.31 no.6
    • /
    • pp.393-399
    • /
    • 1998
  • The composition and the properred orientation of Co-Fe-Cr alloy electrodeposits were invesigated according to the electrolysis conditions using sulface bath. The current efficiency and the cathode overpotential decrased noticeably with the increase of Cr content in the bath. As the D.C. current density increased increased, the Cr content in the alloy increasd, while Co content decreased and Fe content remained constant, In the pulse current electrolysis, the Cr content of the alloy increased with the mean current density and off-time and then its content increased mord more noticeably with the peak current density than that of D.C. electrolysis. The preferred orientation of the alloy changed from (220)+(111) to (220) with decreasing cathode overpotential.

  • PDF

A Study on the Parameter Measurement of Three Phase Brushless DC Moto (삼상 브러시리스 직류전동기의 파라미터 측정에 관한 연구)

  • 임영철;장영학;조경영;정영국
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.5 no.3
    • /
    • pp.54-63
    • /
    • 1991
  • This paper describes an effort to develope a microcomputer-based parameter measurement system for a brushless DC motor. Back EMF equation is derived from back EMF waveform of a brushless DC motor. To minimize error the due to the ripple component in the measured armature current, digital averaging filter is employed. The whole identification process of signal generation, measurement parameter determination is fully automated. A new identification algorithm for the brushless DC motor parameters is developed. New parameter correction method is proposed using the deadzone current and the time to reach the peak current. In the proposed correction method, the measured current is in excellent agreement with the estimated current.

  • PDF

An analytical study on the Effect of High impedance Transformer to reduce Distribution Fault Current (변압기 임피던스 증가에 의한 배전계통의 고장전류 저감방안의 영향분석)

  • Lee, Hyun-Chul;Lee, Geun-Joon;Hyun, Ok-Bae;Hwang, Si-Dol
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.239_240
    • /
    • 2009
  • This paper presents the brief analytical study on 돋 effects of higher impedance transformer(HIT) to reduce distribution system fault current. With the increase of source and load capacity of power system, fault current of D/L is much more increased and, conventional protection equipment-such as sectionalizer and recloser, have to be replaced higher switching capacity. However, this replacements needs a lot of budget to utility. Increase of transformer impedance is can be a countermeasure in practical basis. This paper compares the voltage and fault current magnitude of both cases -%Zt=20% and %Zt2=33.3%(transformer capacity is 75/100MVA). The simulation results show that the steady state voltage of HIT is dropped 5~6% more in peak load, and fault current was decreased about 5kA by high impedance on transformer.

  • PDF

Affect of Corrosion Potential and Current Density on Polarization Curves Variations of Polyvinylchloride[II]

  • Park, Chil-Nam;Yang, Hyo-Kyung;Kim, Sun-Kyu
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • v.3 no.3
    • /
    • pp.159-167
    • /
    • 1999
  • This study performed experiments for measuring corrosion potential and current density variations in the polarzation curves of polyvinylchloride. The results were examined to identify particular influences affectingthe corrosion potential such as temperature, pH, enzyme, and salt. The lines representing active anodic dissolution were only slightly shifted in the potential direction by temperature, pH, enzyme and salt. The Tafel slope for the anodic dissolution was determined using the polarization effect with varying conditions. The slope of the polarization curves describing the active-to-passive transition region was noticeably shifted in the potential direction. In addition, using the variation in conditions, the best temperature and pH were determined for the corrosion rate, and resistance of corrosion. The second anodic current density peak and maximum passive current density were designated as degraded(IP/I0). The value of IP/I0 was used in measuring the extent of the degradation of the polyvinychloride. The potentiodynamic parameters of the corrosion were obtained using a Tafel plot.

  • PDF

Automation of the Parameter Measurement of D.C. Servomotors Using a Microcomputer (마이크로 컴퓨터를 이용한 직류 서어보전동기의 파라미터 측정의 자동화)

  • Chung, Hee-Young;Park, Gwi-T.;Lim, Young-H.;Jang, Young-H.;Cho, Kyeung-Y.
    • Proceedings of the KIEE Conference
    • /
    • 1989.07a
    • /
    • pp.12-15
    • /
    • 1989
  • This paper describes the efforts to develop an PC based parameter identification system for the D.C. servomotor. The whole identification process of signal generation, measuring, parameter determination is fully automated. To minimize errors due to the ripple component in the measured armature current, digital averaging filter is employed. The proposed parameter correction method using the deadzone current and the time to reach the peak current resulted in excellent agreement between the measured current and estimated current using the model.

  • PDF

Analysis of Characteristics for Current Resonant type Boost AC-DC Converter for PFC and Reducing Harmonics (역률개선과 고조파 저감을 위한 전류공진 승압형 AC-DC 컨버터의 특성 해석)

  • Ra, B.H.;Song, D.H.;Suh, K.Y.;Lee, H.W.
    • Proceedings of the KIEE Conference
    • /
    • 2001.11c
    • /
    • pp.341-344
    • /
    • 2001
  • In this paper, the characteristics of the proposed converter are show by simulation. As a result, the power factor is improved and the results show the usefulness of the proposed circuit. To improve the hard switching at turn-off of the basic circuit, the circuit using a current resonant switch is proposed. In the proposed circuit, THD of the input current is reduced to 1.8 of the basic circuit. The mechanism of the THD reduction is clarified. That is because the on period becomes shorter at the peak of the source voltage. Using the simulation, the characteristics of the output voltage, current flowing the switch, and THD of the input current are investigated by changing the resonant circuit parameters. Criteria for choosing resonant parameters of smaller THD are obtained.

  • PDF

Hydrodynamically Optimal Blade Design for 500kW Class Horizontal Axis Tidal Current Turbine (500kW급 수평축 조류발전기의 수력 최적 설계)

  • Ryu, Ki-Wahn
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.5
    • /
    • pp.73-80
    • /
    • 2009
  • A tidal current turbine is designed and analyzed numerically by using blade element momentum theory. The rated power has a limitation because the diameter of the tidal current turbine cannot exceed the depth of sea water. This study investigates a horizontal axis tidal-current turbine with a rated power of 500 kW. NACA-6 series laminar foil shape is used for basic airfoil along the blade span. The distributions of chord length and twist angle along the blade span are obtained from the hydrodynamic optimization procedure. Prandtl's tip loss correction and angle of attack correction considering the three-dimensional effect are applied for this study. The power coefficient curve shows maximum peak at the rated tip speed ratio of 6.0, and the maximum torque coefficient is developed at the tip speed ratio of 4. The drag coefficient reaches about 0.85 at the design tip speed ratio.

A New Partial Resonant Switching $3\phi$ Boost Converter with High Efficiency Using Lossless Snubber (새로운 무손실 스너버를 이용한 부분공진형 고효율 $3\phi$ AC-DC 부스터 컨버터)

  • 전종함;서기영;이현우
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.34S no.9
    • /
    • pp.118-125
    • /
    • 1997
  • This paper proposed a new partial resonant 3.PHI. AC-DC boost converter of high efficiency using lossless snubber. The proposed converter, DCM (Discontinuous Current Mode) has a merit of simple controlled circuit because the input current control discontinuously. But turned off switching loss and stress of the switching device increase when the switch turned off at the peak of current. Therefore, the paper improves efficiency by adopting the PRS$^{2}$(Partial Resonant Soft Switching) in 3.PHI. AC-DC boost converter and makes the unity power factor. The PRS$^{2}$ is reduced a current/voltage stresses of switching devices. Also, a DCMPRS$^{2}$M(Discontinuous Conduction Mode Partial Resonant Soft Switching Method) appear the current and voltage equation of this circuit. The paepr examine in a 3.PHI. AC-DC boost converter and show the result of that.

  • PDF

Influence of Redox Potential Current Density on Polarization Curves with Polypropylene Polymer

  • Park, Chil-Nam;Kim, Myung-Sun
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • v.4 no.4
    • /
    • pp.255-261
    • /
    • 2000
  • Experiments were carried out to measure the corrosion potential and current density variations in the polarization curves of polypropylene. In particular, the results were examined to identify those influences affecting the corrosion potential, such as temperature, pH, salt, and oxygen. The Tafel slope for the anodic dissolution was determined based on the polarization effect under various conditions. Furthermore, the optimum conditions for the most rapid transformation were establish based on a variety of conditions, including temperature, pH, corrosion rate, and resistance of corrosion potential. The second anodic current density peak and maximum passive current density were designated as the critical corrosion sensitivity(I(sub)r/I(sub)f). This I(sub)r/I(sub)f value was then used to measure the critical corrosion sensitivity of polypropylene. The potentiodynamic parameters of corrosion were obtained using a Tafel plot.

  • PDF