Kim, seon myeong;Kim, young bum;Bak, sang yun;Lee, sang rok;Jeong, se young
The Journal of Korean Society for Radiation Therapy
/
v.27
no.2
/
pp.107-113
/
2015
Purpose : The measurement of skin dose is very important that treatment of breast cancer. On account of the cold or hot dose as compared with prescription dose, it is necessary to analyse the skin dose occurring during the various plan of the breast cancer treatment. At our hospital, we want to apply various analyses using a diversity of dosimeters to the breast cancer treatment. Subjectss and Methods : In the study, the anthropomorphic phantom is used to find out the dose difference of the skin(draining site), scar and others occurring from the tangential treatment plan of breast cancer. We took computed tomography scan of the anthropomorphic phantom and made plans for the treatment planing using open and wedge, Field-in-Field, Dose fluence. Using these, we made a comparative analysis of the dose date points by using the Eclipse. For the dose comparison, we place the anthropomorphic phantom in the treatment room and compared the measurement results by using the TLD and MOSFET on the dose data points. Results : On the central point of treatment planing basis, the upward and downward skin dose measured by the MOSFET was the highest when the fluence was used. The skin dose of inner and outer was distinguished from the figure(5.7% ~ 10.3%) when the measurements were fulfilled by using TLD and MOSFET. The other side of breast dose was the lowest in the open beam, on the other hand, is highest in the Dose fluence plan. In the different kinds of treatment, the dose deviation of inner and outer was the highest, and so this was the same with the TLD and MOSFET measurement case. The outer deviation was highest in the TLD, and the Inner'was highest in the MOSFET. Conclusion : Skin dose in relation to the treatment plan was the highest in the planing using the fluence technique in general and it was supposed that the high dose had been caused by the movement of the MLC. There's some differences among the all the treatment planning, but the sites such as IM node occurring the lack of dose, scar, drain site are needed pay close attention. Using the treatment planning of dose fluence is good to compensate the lack of dose, but It increases the dose of the selective range rather than the overall dose. Therefore, choosing the radiotherapy technique is desirable in the lights of the age and performance of the patient.
Kim, Jong-Deok;Lee, Haeng-O;You, Jae-Man;Ji, Dong-Hwa;Song, Ju-Young
The Journal of Korean Society for Radiation Therapy
/
v.19
no.1
/
pp.1-5
/
2007
Purpose: The accuracy and advantages of OBI(On Board Imager) against the conventional method like film and EPID for the setup error correction were evaluated with the analysis of the accumulated data which were produced in the process of setup error correction using OBI. Materials and Methods: The results of setup error correction using OBI system were analyzed for the 130 patients who had been planned for 3 dimensional conformal radiation therapy during March 2006 and May 2006. Two kilo voltage images acquired in the orthogonal direction were fused and compared with reference setup images. The setup errors in the direction of vertical, lateral, longitudinal axis were recorded and calculated the distance from the isocenter. The corrected setup error were analyzed according to the lesion and the degree of shift variations. Results: There was no setup error in the 41.5% of total analyzed patients and setup errors between 1mm and 5mm were found in the 52.3%. 6.1% patients showed the more than 5mm shift and this error were verified as a difference of setup position and the movement of patient in a treatment room. Conclusion: The setup error analysis using OBI in this study verified that the conventional setup process in accordance with the laser and field light was not enough to get rid of the setup error. The KV images acquired using OBI provided good image quality for comparing with simulation images and much lower patients' exposure dose compared with conventional method of using EPID. These advantages of OBI system which were confirmed in this study proved the accuracy and priority of OBI system in the process of IGRT(Image Guided Radiation Therapy).
Purpose : Early surfactant treatment and minimal ventilation, bronchopulmonary dysplasia needed prolonged oxygen supplement is a problem. This study aimed to report the effects of early surfactant treatment and minimal ventilation on the prevention of bronchopulmonary dysplasia in respiratory distress syndrome. Methods : We retrospectively studied 139 premature newborn infants (gestational age, 36 weeks; birth weight, 1,500 gm) admitted to the neonatal intensive care unit of Daegu Fatima Hospital between January 2001 and December 2006. We analyzed the occurrence of bronchopulmonary dysplasia with respect to ventilator care and surfactant treatment. Results : The incidence of bronchopulmonary dysplasia was significantly higher with prolonged ventilator care, moderate to severe respiratory distress syndrome, and low Apgar score (P<0.001). Despite early surfactant treatment and minimal ventilation, mild bronchopulmonary dysplasia occurs in a considerable number of patients with mild respiratory distress syndrome. The patient group with low Apgar scores required ventilator care for a prolonged period (P=0.020). Conclusion : Early surfactant treatment and minimal ventilation shortens the duration of ventilator care; however, the preventive effects on bronchopulmonary dysplasia are limited. Therefore, not only early surfactant treatment and minimal ventilation but also appropriate management in the delivery room is essential.
Purpose: Alvarado scoring system was evaluated regarding its usefulness for the early diagnosis of acute appendicitis in adult and in reduction of the incidence of negative appendicectomies. To evaluate the accuracy of diagnosing appendicitis using the Alvarado score in children. Methods: Prospectively, we surveyed 122 patients (male 67, female 55) suffering from abdominal pain, who had visited to the emergency department of Chosun University Hospital from June 2002 to May 2003. The Alvarado score has been computed from the white blood cell count, neutrophil count, body temperature, resistance in the right lower quadrant, length of symptoms, nausea and vomiting. Each patient was evaluated by a pediatric resident and then by a general surgeon independently. Results: Out of 170 total children who visited to the emergency department due to abdominal pain, 122 patients were associated with appendicitis. A total of 122 patients (67 male and 55 female) were visited to the emergency room with suspected appendicitis. From 105 operated patients, 92 (87.6%) were diagnosed acute appendicitis and erronous diagnostic rate was 12.4%, pathologically. Mean alvarado score of appendicitis group was $5.40{\pm}1.24$ whereas those of non-appendicitis group was $3.73{\pm}1.82$ (p<0.05). From 6 Alvarado score high sensitivity (86.4%) and high specificity (80.0%) were observed. Sensitivity of ultrasonography or computed tomography was 92.5%. Conclusion: We found that Alvarado score system is a noninvasive, safe diagnostic method, which is simple, reliable and repeatable. Alvarado score is useful system for a first, rapid and economic evaluation for the appendicitis in children.
This study was done to investigate how importantly midwives thought of Lamaze Method of Childbirth, how satisfactorily they performed their Lamaze Method of Childbirth and what inhibited their activities from being performed if not done satisfactorily. The subjects of this study were 76midwives at midwifery in Pusan, Deagu, Kyungnam and Kyungbok. Data were collected by using questionaire from Sep. 1 to Sep.30, 1991. The measurement tools was maded by the researcher based on Kim's scale for prenatal nursing activities. The statistical analysis was done with based statistical values likes frequencies, means, standard deviations and advanced methods such as Pearson's correlation coefficient, 1-test, F-test, F-test by using SPSS package program. The results of this study can be summarized as follows ; 1. The results of Investigating perception according to importance degree and performance degree of Lamaze Method of Childbring showed that midwives were slightly below both perception according to importance(2.17) and performance(2.16) of Lamaze Method of Childbirth 2. Inhibiting factors of Lamaze Method of Childbirth were abscence of husband(3.08), lack of teaching room(2.71), and lack of books or literature of Lamaze Method (2.58). 3. There appears to be a positive relation between perception according to importance degree and performance degree of Lamaze Method of Childbirth (r=0.69, P<0.01). There appears to be a negative relation between perception according to importance degree and inhibit factors of performance (r=-0.38, P<0.01). There appears to be a negative relation between performance and inhibit factors of performance (r=-0.22. P<0.01). 4. The item of highest perception defree in prenatal education is 1st, Consultation about sexual life (2.53), End, illustration of the importance of a bath and perinal cleanliness and Avoidance of excessive respiration method and also its comfortable application during uterine contractility(2.45). The item of lowest perception degree is about pregnant symptom sign and predicted date of birth (E.D.C.). On the other hand, The item of highest performance degree is education about nurtrition during pregnacy. 2nd, Illustration of the Importance of a bath and perineal cleanness(2.45). The lowest one is leaching the pregnant woman and her family about the role of husband and her family and also teaching the couple to learn exercise and respiration method (1.84). Though importance perception degree and performance degree is low. Midwives who wert subject in this research shoves that they perform general items concerning prenatal education well. 5. In the relationship between perception according to importance degree of Lamaze Method of Childbirth and the general characteristics of subjects, the differences in mean number of visiting pregnacies for 1 month. 6. In the relationship between performance degree of Lamaze Method of Childbirth and the general characteristics of subjects, the differences in age, marriage, and mean number of visiting pregnancies for 1 month. With the above information we see the importance of midwife prenatal care education and high correlation between performance degree and perception degree. When Lamaze prenatal education is well performed the number of pregnant woman who have follow-up, check-ups increase. Therefore in this research we can validity that there is a relation between Lamaze prenatal education and patient follow-up. This research showes in a situation where if one does not maximally perform a prenatal education there is a possibility that the popular use of midwife activities may encounter obstacles so the education to save new knowledge and training for prenatal education is needed as a function of Lamaze prenatal education, when a special Lamaze education is well performed for the pregnant woman, who follows-up at amidwife clinic. With the above conclusion we can suggest : 1. Continued research which minimized obstacles to Lamaze prenatal education is needed. 2. The official method of midwives is necessary.
Purpose: Recognition of impending death is crucial not only for efficient communication with the caregiver of the patient, but also determination of the time to refer to a separate room. Current studies simply list the events 'that have already occurred' around 48 hours before the death. This study is to analyze the predictability of each event by comparing the time length from 'change' to death. Methods: Subjects included 160 patients who passed away in a palliative care unit in Incheon. The analysis was limited to 80 patients who had medical records for the last week of their lives. We determined 9 symptoms and 8 signs, and established the standard of 'significant change' of each event before death. Results: The most common symptom was increased sleeping (53.8%) and the most common sign was decreased blood pressure (BP) (87.5%). The mean time to death within 48 hours was 46.8% in the case of resting dyspnea, 13.6% in the ease of low oxygen saturation, and 36.9% in the case of decreased BP. The symptom(s) which had the highest positive predictive value (PV) for death within 48 hours was shown to be resting dyspnea (83%), whereas the combination of resting dyspnea and confusion/delirium (65%) had the highest negative PV. As for the most common signs before death within 48 hours, the positive PVs were more than 95%, and the negative PV was the highest when decreased BP and low oxygen saturation were combined. The difference in survival patterns between symptoms and signs was significant. Conclusion: The most reliable symptoms to predict the impending death are resting dyspnea and confusion/delirium, and decline of oxygen saturation and BP are the reliable signs to predict the event.
Purpose: According to increment of thyroid cancer recently, patients of high dose radioiodine therapy were accumulated. Taking into consideration the acceptance capability in the current facility, this study is to calculate the maximum value of high dose radioiodine therapy in patients for treatment. Materials and Methods: The amount and radioactivity of waste water discharged from high dose radioiodine therapy in patients admitted at present hospital as well as the radiation density of the air released into the atmosphere from the high dose radioiodine therapy ward were measured. When the calculated waste water's radiation and its density in the released air satisfies the standard (management standard for discharge into water supply 30 Bq/L, management standard for release into air 3 $Bq/m^3$) set by the Ministry of Education, Science and Technology, the maximum value of treatable high dose radioiodine therapy in patients was calculated. Results: When we calculated in a conservative view, the average density of radiation of waste water discharged from treating high dose radioiodine therapy one patient was 8 MBq/L and after 117 days of diminution in the water-purifier tank, it was 29.5 Bq/L. Also, the average density of radiation of waste water discharged from treating high dose radioiodine therapy two patients was 16 MBq/L and after 70 days of diminution in the water-purifier tank, it was 29.7 Bq/L. Under the same conditions, the density of radiation released into air through RI Ventilation Filter from the radioiodine therapy ward was 0.38 $Bq/m^3$. Conclusion: The maximum value of high dose radioiodine therapy in patients that can be treated within the acceptance capability was calculated and applied to the current facility, and if double rooms are managed by improving the ward structure, it would be possible to reduce the accumulated treatment waiting period for radioiodine therapy in patients.
Kang, Jino;Kim, Hye Ri;Min, Kyungjoon;Kim, Na Ryoung;Heo, Yoon Kyung;Kim, Sun Mi
Korean Journal of Psychosomatic Medicine
/
v.27
no.2
/
pp.130-137
/
2019
Objectives : When a patient who attempts suicide visits the emergency room, it is important that the departments of emergency medicine, internal medicine, and psychiatry communicate with each other and prioritize treatment. This study was conducted to verify the effectiveness of the multidisciplinary emergency consultation system (ECS) for drug intoxicated patients. Methods : We retrospectively analyzed the data from medical records prior to the ECS, from July 2017 to May 2018, and after the ECS, from July 2018 to May 2019, to verify the effectiveness of the system. Results : After the ECS, admission to open wards was significantly higher than to the intensive care units (χ2=8.567, p=0.014). In addition, the proportion of consultations to the department of psychiatry among patients admitted to other departments tended to increase (χ2=4.202, p=0.053), and the time required for consultation response decreased (Z=-2.031, p=0.042). As a result of the consultation, the proportion of the patients who had been transferred to the department of psychiatry was increased (χ2=4.692, p=0.043), and the time spent to transfer tended to decrease (Z=-1.941, p=0.052). Conclusions : After implementing the ECS for drug intoxicated patients, unnecessary intensive care unit admissions, consultation response time, and the time spent to transfer were reduced, and the rate of consultation referrals and transfer rates increased. This means that the multidisciplinary consultation system rapidly provided essential medical services to patients at lower medical costs.
We did Tc-99m sestamibi myocardial perfusion SPECT in 36 patients with acute myocardial infarction when they arrived at the emergency room. And we compared myocardial perfusion images with ECG findings. Then we obtained the follows. The myocardial infarction by the obstruction of left coronary descending artery and right coronary artery showed a good concordance in the diagnosis and infarction site between myocardial perfusion images and ECG findings. The 7 patients with myocardial infarction by a left circumflex coronary artery showed a perfusion defect in the lateral wall in myocardial perfusion SPECT images. But 4 patients of them showed ST segment elevation, 2 patients showed ST depression and 1 patient showed normal ECG findings. The diagnostic sensitivity of Tc-99m sestamibi myocardial perfusion SPECT was 100% by a qualified analysis. The perfusion defect site in the myocardial perfusion SPECT were corresponded with the infarct related coronary artery in 31 patients which was diagnosed by coronary angiograpy. The size of perfusion defect in the po1ar map was $31{\pm}18%(M{\pm}SD)$, in the myocardial infarction with left anterior descending coronary arery obstruction, $31{\pm}13% (M{\pm}SD)$ in the myocardial infarction with right coronary artery obstruction and $25{\pm}5.9%(M{\pm}SD)$ in the myocardial infarction with left circumflex coronary artery obstruction. We concluded that emergency myocardial perfusion SPECT images are useful in the diagnose of myocardial infarction and it's very useful when we are difficult to diagnose with ECG like as lateral wall infarction or left bundle branch block.
The Journal of Korean Society for Radiation Therapy
/
v.21
no.1
/
pp.33-39
/
2009
Purpose: The aim of this study is to compare patient's body posture and its position at the time of simulation with one at the treatment room using On-board Imaging (OBI) and CT (CBCT). The detected offsets are compared with position errors of Rando Phantom that are practically applied. After that, Rando Phantom's position is selected by moving couch based on detected deviations. In addition, the errors between real measured values of Rando Phantom position and theoretical ones is compared. And we will evaluate target position's accuracy of KV X-ray imaging's 2D and CBCT's 3D one. Materials and Methods: Using the Rando Phantom (Alderson Research Laboratories Inc. Stanford. CT, USA) which simulated human body's internal structure, we will set up Rando Phantom on the treatment couch after implementing simulation and RTP according to the same ways as the real radioactive treatment. We tested Rando Phantom that are assumed to have accurate position with different 3 methods. We measured setup errors on the axis of X, Y and Z, and got mean standard deviation errors by repeating tests 10 times on each tests. Results: The difference between mean detection error and standard deviation are as follows; lateral 0.4+/-0.3 mm, longitudinal 0.6+/-0.5 mm, vertical 0.4+/-0.2 mm which all within 0~10 mm. The couch shift variable after positioning that are comparable to residual errors are 0.3+/-0.1, 0.5+/-0.1, and 0.3+/-0.1 mm. The mean detection errors by longitudinal shift between 20~40 mm are 0.4+/-0.3 in lateral, 0.6+/-0.5 in longitudinal, 0.5+/-0.3 in vertical direction. The detection errors are all within range of 0.3~0.5 mm. Residual errors are within 0.2~0.5 mm. Each values are mean values based on 3 tests. Conclusion: Phantom is based on treatment couch shift and error within the average 5mm can be gained by the diminution detected by image registration based on OBI and CBCT. Therefore, the selection of target position which depends on OBI and CBCT could be considered as useful.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.