• Title/Summary/Keyword: patient room

Search Result 861, Processing Time 0.037 seconds

Automatic Notification System for Nuclear Medicine Blood Test (핵의학 혈액 검사의 경고치 자동통보 시스템)

  • Sim, Seong-Jae;Yoon, Pil-Young;Lim, Soo-Yeon;Cheon, Jun-Hong;Shin, Young-Kyoon;Yu, Seon-Hui;Cho, Si-Man
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.159-164
    • /
    • 2009
  • Purpose: The automatic notification system for alarm values on blood tests conducted by this hospital is designed to immediately inform the attending physician of the result of a blood test, to help the relevant patient to promptly receive proper treatment, and furthermore, to reduce the likelihood of a fatal influence to the patient. From 2004, the clinical pathology department of this hospital has been operating an automatic notification system for blood tests, in relation to the items of WBC, Hb, Plt, PB cell morphology, Malaria, PT, aPTT, BT, fibrinogen, Ca, K, Na, Cl, Mg, Glucose, Ketone, Digoxin, PKU, Homocystinuria, 17-OHP, Neonatal TSH, and Galactosemia. Recently, the blood test room of the nuclear medicine department has been operating an automatic notification system for the alarm values of a blood test, in relation to three items of TSH, FT4, and 17-${\alpha}$-OH-PGR, and the details of its operation will be described here. Materials and Methods: The subjects were newborn babies that were receiving TSH, FT4, and $17{\alpha}$-OH-PGR prescriptions from February $19^{th}$ to May $11^{st}$, 2009, and who met with the following criteria: N2340 Thyroid-Stimulating Hormone: >$10{\mu}IU/mL$ (Reference value: 0.4~5.0). N2360 Free-Thyroxine: <$0.8{\mu}g/dL$ (Reference value: 0.8~1.9), N2444 $17{\alpha}$-OH-Progesterone: >$30\;{\mu}g/mL$ (Reference value: Male (0.6~3.42), Female follicular phase (0.19~1.8). The automatic notification system was operated by entering test items, relevant treatment departments, and standard values for reporting alarm values into the OCS program, and then transmitting results that met with the input conditions to the PDAs of the prescription and the attending physician by SMS. Results: Reporting an alarm value of the nuclear medicine blood test, which can have a fatal influence on the lives of patients, will help cure patients, improve the quality of the test, and furthermore, will increase the patient's satisfaction with the prescription and treatment of the test.

  • PDF

Early and Mid-Term Results of MIDCAB (최소 침습적 관상 동맥 우회술의 중단기 성적)

  • 손호성;방영호;황진욱;민병주;조양현;박성민;이성호;김광택;선경
    • Journal of Chest Surgery
    • /
    • v.37 no.10
    • /
    • pp.827-832
    • /
    • 2004
  • Background: The significance of MIDCAB is emerging topics recently as OPCAB is going to be universalized, and long-term outcome of bypass graft surgery was proved to be more excellent than balloon dilation or stent insertion. We report our MIDCAB results in 73 patients in the last three years. Material and Method: Retrospective analysis of medical records was done from November 1, 2000 through November 31, 2003. There were 47 males and 26 females ranging in age from 31 years to 79 years (average $61.3\pm9.8$ years). Observation periods after operative procedures were 10 to 1238 days (average $763\pm319.8$ days). Left longitudinal parasternal incision as a standard procedure was done to approach the heart after dissection of the left internal thoracic artery by partial or total resection of 3rd to 5th ribs. Result: Of those patients, 46 patients were transferred to ICU after extubation at operation room and 58 patients were extubated within 3 hours after operation. Average ICU staying periods was $26.8\pm11.5$ hours. Follow-up angiography during admission was done in 36 patients and showed 100% patency. Only one patient died on the 10$^{th}$ post operative day because of sudden CVA. Complications included wound problems in 4 patients, and constructing pericardial window using thoracoscopy due to continuous pericardial effusion in 1. Permanent pacemaker was inserted in one patient owing to sick sinus syndrome. In one patient with recurrence of angina 8 months after operation, stenosis at anastomic site was found and improved with balloon dilatation. Conclusion: We were satisfied with our results of MIDCAB in single and multi-vessel coronary artery disease. These results have made the cardiologists tried to operate positively and we expect widening operative indications including hybrid revascularization.

3-D Conformal Radiotherapy for CNS Using CT Simulation (입체조준장치를 이용한 중추신경계의 방사선 입체조형치료 계획)

  • 추성실;조광환;이창걸
    • Progress in Medical Physics
    • /
    • v.14 no.2
    • /
    • pp.90-98
    • /
    • 2003
  • Purpose : A new virtual simulation technique for craniospinal irradiation (CSI) that uses a CT-simulator was developed to improve the accuracy of field and shielding placement as well as patient positioning. Materials and Methods : A CT simulator (CT-SIM) and a 3-D conformal radiation treatment planning system (3D-CRT) were used to develop CSI. The head and neck were immobilized with a thermoplastic mask while the rest of the body was immobilized with a Vac-Loc. A volumetric image was then obtained with the CT simulator. In order to improve the reproducibility of the setup, datum lines and points were marked on the head and body. Virtual fluoroscopy was performed with the removal of visual obstacles, such as the treatment table or immobilization devices. After virtual simulation, the treatment isocenters of each field were marked on the body and on the immobilization devices at the conventional simulation room. Each treatment fields was confirmed by comparing the fluoroscopy images with the digitally reconstructed radiography (DRR) and digitally composited radiography (DCR) images from virtual simulation. Port verification films from the first treatment were also compared with the DRR/DCR images for geometric verification. Results : We successfully performed virtual simulations on 11 CSI patients by CT-SIM. It took less than 20 minutes to affix the immobilization devices and to obtain the volumetric images of the entire body. In the absence of the patient, virtual simulation of all fields took 20 min. The DRRs were in agreement with simulation films to within 5 mm. This not only reducee inconveniences to the patients, but also eliminated position-shift variables attendant during the long conventional simulation process. In addition, by obtaining CT volumetric image, critical organs, such as the eyes and the spinal cord, were better defined, and the accuracy of the port designs and shielding was improved. Differences between the DRRs and the portal films were less than 3 m in the vertebral contour. Conclusion : Our analysis showed that CT simulation of craniospinal fields was accurate. In addition, CT simulation reduced the duration of the patient's immobility. During the planning process. This technique can improve accuracy in field placement and shielding by using three-dimensional CT-aided localization of critical and target structures. Overall, it has improved staff efficiency and resource utilization by standard protocol for craniospinal irradiation.

  • PDF

Effects of Telephone Hotline Counseling Program on Stroke Care (뇌졸중 환자에 적용한 핫라인 전화상담 프로그램의 효과)

  • Baik Kyun Kim;Dong-Wan Kang;Do Yeon Kim;Jung Hyun Park;Ji-Seok Woo;Young-Hee Kim;Hyun-Sook Kim;Min-Joo Moon;Jeong-Yoon Lee;Hyung Seok Guk;Nakhoon Kim;Sang-Won Choi;Hakyeu Ahn;Bosco Seong Kyu Yang;Jun Yup Kim;Jihoon Kang;Moon-Ku Han;Hee-Joon Bae;Beom Joon Kim
    • Health Policy and Management
    • /
    • v.33 no.2
    • /
    • pp.185-193
    • /
    • 2023
  • Background: This study focuses on the establishment and operation of a stroke patient hotline program to help patients and their caregivers determine when acute neurological changes require emergency attention. Method: The stroke hotline was established at the Gyeonggi Regional Cerebrovascular Center, Seoul National University Bundang Hospital, in June 2016. Patients diagnosed with stroke during admission or in outpatient clinics were registered and provided with stroke education. Consulting nurses managed hotline calls and made decisions about outpatient schedules or emergency room referrals, consulting physicians when necessary. The study analyzed consultation records from June 2016 to December 2020, assessing consultation volumes and types. Outcomes and hotline satisfaction were also evaluated. Results: Over this period, 6,851 patients were registered, with 1,173 patients (18%) undergoing 3,356 hotline consultations. The average monthly consultation volume increased from 29.2 cases in 2016 to 92.3 cases in 2020. Common consultation types included stroke symptoms (22.3%), blood pressure/glucose inquiries (12.8%), and surgery/procedure questions (12.6%). Unexpected outpatient visits decreased from 103 cases before the hotline to 81 cases after. Among the 2,244 consultations between January 2019 and December 2020, 9.6% were recommended hospital visits, with two cases requiring intra-arterial thrombectomy. Patient satisfaction ratings of 9-10 points increased from 64% in 2019 to 69% in 2020. Conclusion: The stroke hotline program effectively reduced unexpected outpatient visits and achieved high patient satisfaction. Expanding the program could enhance the management of stroke-related neurological symptoms and minimize unnecessary healthcare resource utilization.

Shielding for Critical Organs and Radiation Exposure Dose Distribution in Patients with High Energy Radiotherapy (고 에너지 방사선치료에서 환자의 피폭선량 분포와 생식선의 차폐)

  • Chu, Sung-Sil;Suh, Chang-Ok;Kim, Gwi-Eon
    • Journal of Radiation Protection and Research
    • /
    • v.27 no.1
    • /
    • pp.1-10
    • /
    • 2002
  • High energy photon beams from medical linear accelerators produce large scattered radiation by various components of the treatment head, collimator and walls or objects in the treatment room including the patient. These scattered radiation do not provide therapeutic dose and are considered a hazard from the radiation safety perspective. Scattered dose of therapeutic high energy radiation beams are contributed significant unwanted dose to the patient. ICRP take the position that a dose of 500mGy may cause abortion at any stage of pregnancy and that radiation detriment to the fetus includes risk of mental retardation with a possible threshold in the dose response relationship around 100 mGy for the gestational period. The ICRP principle of as low as reasonably achievable (ALARA) was recommended for protection of occupation upon the linear no-threshold dose response hypothesis for cancer induction. We suggest this ALARA principle be applied to the fetus and testicle in therapeutic treatment. Radiation dose outside a photon treatment filed is mostly due to scattered photons. This scattered dose is a function of the distance from the beam edge, treatment geometry, primary photon energy, and depth in the patient. The need for effective shielding of the fetus and testicle is reinforced when young patients ate treated with external beam radiation therapy and then shielding designed to reduce the scattered photon dose to normal organs have to considered. Irradiation was performed in phantom using high energy photon beams produced by a Varian 2100C/D medical linear accelerator (Varian Oncology Systems, Palo Alto, CA) located at the Yonsei Cancer Center. The composite phantom used was comprised of a commercially available anthropomorphic Rando phantom (Phantom Laboratory Inc., Salem, YN) and a rectangular solid polystyrene phantom of dimensions $30cm{\times}30cm{\times}20cm$. the anthropomorphic Rando phantom represents an average man made from tissue equivalent materials that is transected into transverse 36 slices of 2.5cm thickness. Photon dose was measured using a Capintec PR-06C ionization chamber with Capintec 192 electrometer (Capintec Inc., Ramsey, NJ), TLD( VICTOREEN 5000. LiF) and film dosimetry V-Omat, Kodak). In case of fetus, the dosimeter was placed at a depth of loom in this phantom at 100cm source to axis distance and located centrally 15cm from the inferior edge of the $30cm{\times}30cm^2$ x-ray beam irradiating the Rando phantom chest wall. A acryl bridge of size $40cm{\times}40cm^2$ and a clear space of about 20 cm was fabricated and placed on top of the rectangular polystyrene phantom representing the abdomen of the patient. The leaf pot for testicle shielding was made as various shape, sizes, thickness and supporting stand. The scattered photon with and without shielding were measured at the representative position of the fetus and testicle. Measurement of radiation scattered dose outside fields and critical organs, like fetus position and testicle region, from chest or pelvic irradiation by large fie]d of high energy radiation beam was performed using an ionization chamber and film dosimetry. The scattered doses outside field were measured 5 - 10% of maximum doses in fields and exponentially decrease from field margins. The scattered photon dose received the fetus and testicle from thorax field irradiation was measured about 1 mGy/Gy of photon treatment dose. Shielding construction to reduce this scattered dose was investigated using lead sheet and blocks. Lead pot shield for testicle reduced the scatter dose under 10 mGy when photon beam of 60 Gy was irradiated in abdomen region. The scattered photon dose is reduced when the lead shield was used while the no significant reduction of scattered photon dose was observed and 2-3 mm lead sheets refuted the skin dose under 80% and almost electron contamination. The results indicate that it was possible to improve shielding to reduce scattered photon for fetus and testicle when a young patients were treated with a high energy photon beam.

A Study on the Availability of the On-Board Imager(OBI) and Cone-Beam CT(CBCT) in the Verification of Patient Set-up (온보드 영상장치(On-Board Imager) 및 콘빔CT(CBCT)를 이용한 환자 자세 검증의 유용성에 대한 연구)

  • Bak, Jino;Park, Sung-Ho;Park, Suk-Won
    • Radiation Oncology Journal
    • /
    • v.26 no.2
    • /
    • pp.118-125
    • /
    • 2008
  • Purpose: On-line image guided radiation therapy(on-line IGRT) and(kV X-ray images or cone beam CT images) were obtained by an on-board imager(OBI) and cone beam CT(CBCT), respectively. The images were then compared with simulated images to evaluate the patient's setup and correct for deviations. The setup deviations between the simulated images(kV or CBCT images), were computed from 2D/2D match or 3D/3D match programs, respectively. We then investigated the correctness of the calculated deviations. Materials and Methods: After the simulation and treatment planning for the RANDO phantom, the phantom was positioned on the treatment table. The phantom setup process was performed with side wall lasers which standardized treatment setup of the phantom with the simulated images, after the establishment of tolerance limits for laser line thickness. After a known translation or rotation angle was applied to the phantom, the kV X-ray images and CBCT images were obtained. Next, 2D/2D match and 3D/3D match with simulation CT images were taken. Lastly, the results were analyzed for accuracy of positional correction. Results: In the case of the 2D/2D match using kV X-ray and simulation images, a setup correction within $0.06^{\circ}$ for rotation only, 1.8 mm for translation only, and 2.1 mm and $0.3^{\circ}$ for both rotation and translation, respectively, was possible. As for the 3D/3D match using CBCT images, a correction within $0.03^{\circ}$ for rotation only, 0.16 mm for translation only, and 1.5 mm for translation and $0.0^{\circ}$ for rotation, respectively, was possible. Conclusion: The use of OBI or CBCT for the on-line IGRT provides the ability to exactly reproduce the simulated images in the setup of a patient in the treatment room. The fast detection and correction of a patient's positional error is possible in two dimensions via kV X-ray images from OBI and in three dimensions via CBCT with a higher accuracy. Consequently, the on-line IGRT represents a promising and reliable treatment procedure.

Inappropriate Care of Oncologic Emergency in Korea (암환자 응급진료의 현황 및 문제점)

  • Heo, Dae-Seog;Yun, Young-Ho;Jeong, Joo-Young;Kim, Hong-Soo;Kim, Sung-Hye;Shin, Sang-Do;Rhee, Joong-Eui;Oh, Eun-Kyung;Yoo, Chul-Gyu;Bang, Yung-Jue;Kim, Noe-Kyeong
    • Journal of Hospice and Palliative Care
    • /
    • v.1 no.1
    • /
    • pp.14-22
    • /
    • 1998
  • Purpose : Cancer is a common cause for admission to emergency room(ER). Cancer patient present to ER with undiagnosed cancer, acute vague problem of cancer, or treatment related complication. But there is little information on the magnitute of the problems in the Korea. The purposes of our study were to evaluate the appropriateness of care for oncologic emergencies in Korea. Materials and Methods : This study was undertaken of all cancer patients above 15 years old presenting to the Seoul National University Hospital ER, who visited during the period from Oct. 16 to Nov. 15, 1997. ER record was reviewed and ER doctors evaluated patients' reason for visiting ER, appropriateness in patients' utilization of ER, oncology emergency Results : 266 cancer patients(17.4% of total patients) visited ER during this period and 166 cancer patients(62.4%) utilized inappropriately ER. Their average stay is 32.0 hours and 65.8% of them stayed for 6 hours. There were complaints of patients such as pain(44.8%), abdomen distension(9.4%), and dyspnea(7.5%). The most common oncologic emergency in ER during this study were gastrointestinal(34.0%), neurologic(21%), hematologic(8.0%), infectious(7.0%), respiratory(6.0%), and genitourinary(5.0%). Conclusion : For the care of symptoms like pain, most of cancer patients utilize ER inappropriately due to lack of attention from primary health delivery system. For the better care, the palliative medicine should be established in Korea.

  • PDF

Effect of Work Improvement for Promotion of Outpatient Satisfaction on CT scan (CT 외래환자의 만족도 향상을 위한 업무개선 연구)

  • Han, Man-Seok;Lee, Seung-Youl;Lee, Myeong-Goo;Jeon, Min-Cheol;Cho, Jae-Hwan;Kim, Tae-Hyung
    • Journal of radiological science and technology
    • /
    • v.35 no.1
    • /
    • pp.45-50
    • /
    • 2012
  • Nowadays, most of the hospital serves "one stop service" for CT scan. The patients could be taken the CT scan in the day they register for scan. On the contrary to the time convenience, patients are not satisfied with long waiting time and unkindness of staff. The objective of this study is to improve the patient's satisfaction for the CT scan, by analyzing inconvenience factors and improving the service qualities. From April 1 to August 30 in 2011, we investigated the satisfaction of patients who did examined abdomen CT scan with contrast media. We analyzed the 89 questionnaires before and after the service improvements from them. The worker's kindness, the environment of CT room and understanding about CT scan were answered by questionnaire and the waiting time of a day CT scan was drawn by medical information statistics. Also, the period before improvement was from April to June and the period after improvement was from July to September. And these questionnaire was analyzed through SPSS V. 15.0. In this study, kindness of staff, environment of CT room, intelligibility for CT scan and waiting time was explored and analyzed by SPSS V.15.0. The score of kindness was improved by 32%, satisfaction level of the environment was improved by 52.54%. The understanding level about CT scan was improved by 52.36% and the wating time of a day CT was shortened by 21% through our service enhancement programs. Consequentially, it is considered that these efforts would contribute to increase the revenue of hospital.

Evaluation of the Usefulness of the Respiratory Guidance System in the Respiratory Gating Radiation Therapy (호흡동조 방사선치료 시 호흡유도시스템의 유용성 평가)

  • Lee, Yeong-Cheol;Kim, Sun-Myung;Do, Gyeong-Min;Park, Geun-Yong;Kim, Gun-Oh;Kim, Young-Bum
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.167-174
    • /
    • 2012
  • Purpose: The respiration is one of the most important factors in respiratory gating radiation therapy (RGRT). We have developed an unique respiratory guidance system using an audio-visual system in order to support and stabilize individual patient's respiration and evaluated the usefulness of this system. Materials and Methods: Seven patients received the RGRT at our clinic from June 2011 to April 2012. After breathing exercise with the audio-visual system, we measured their spontaneous respiration and their respiration with the audio-visual system respectively. With the measured data, we yielded standard deviations by the superficial contents of respiratory cycles and functions, and analyzed them to examine changes in their breathing before and after the therapy. Results: The PTP (peak to peak) of the standard deviations of the free breathing, the audio guidance system, and the respiratory guidance system were 0.343, 0.148, and 0.078 respectively. The respiratory cycles were 0.645, 0.345, and 0.171 respectively and the superficial contents of the respiratory functions were 2.591, 1.008, and 0.877 respectively. The average values of the differences in the standard deviations among the whole patients at the CT room and therapy room were 0.425 for the PTP, 1.566 for the respiratory cycles, and 3.671 for the respiratory superficial contents. As for the standard deviations before and after the application of the PTP respiratory guidance system, that of the PTP was 0.265, that of the respiratory cycles was 0.474, and that of the respiratory superficial contents. The results of t-test of the values before and after free breathing and the audio-visual guidance system showed that the P-value of the PTP was 0.035, that of the cycles 0.009, and that of the respiratory superficial contents 0.010. Conclusion: The respiratory control could be one of the most important factors in the RGRT which determines the success or failure of a treatment. We were able to get more stable breathing with the audio-visual respiratory guidance system than free breathing or breathing with auditory guidance alone. In particular, the above system was excellent at the reproduction of respiratory cycles in care units. Such a system enables to reduce time due to unstable breathing and to perform more precise and detailed treatment.

  • PDF

Clinical Analysis of the Pediatric Patients Seen in the Emergency Medical Center (응급의료센터 소아 환자들의 경향 분석)

  • Lee, Hee Jung;Park, So Yoon;Lee, Young Hwan;Do, Byung Soo;Lee, Sam Bum
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.10
    • /
    • pp.1061-1067
    • /
    • 2005
  • Purpose : We studied a clinical analysis of pediatric patients who visited the emergency medical center of Yeungnam University Hospital to compare the characteristics of pediatric emergency patients after year 2000 with the previous studies. Methods : We reviewed 7,034 children under the age of 15 years who visited the emergency medical center of Yeungnam University Hospital during the 2 year period from January 2001 to December 2002, and then we performed a clinical and statistical analysis. We analyzed the pediatric patients according to gender, age, season, day of the week, time of the visit, the disease classification and the final disposition of the patients. Results : Among the patients who visited the emergency room, 15.6% of the total emergency patients were under the age of 15. The male to female ratio was 1.6 : 1. Among the 7,034 pediatric patients, the most common age group was between 1 year and under 3 years of age(26.9%). The peak seasonal incidence was early summer and spring, especially during June(11.2%) and May(10.6 %). The peak incidence day of the week was Sunday(24.8%) and the peak time when the emergency pediatric patients visited the emergency room was between 20 and 24 o'clock(28.8%). The distribution of diseases, according to ICD-10 system, were injury and poisoning(30.4%), diseases of the respiratory system(22.8%), and diseases of the digestive system(14.6%). 30% of total pediatric patients were admitted to the hospital. Conclusion : After year 2000, as compared with the previous studies, the proportions of emergency pediatric patients has decreased. The distribution of diseases was not much different from the previous studies and the proportions of non-urgent diseases, such as acute nasopharyngitis or acute gastroenteritis, were still high. These result have come about due to the declining birth rate and changes of the medical system in Korea.