• 제목/요약/키워드: patient exposure dose

검색결과 380건 처리시간 0.021초

뇌 동맥류 질환 자기공명검사에서 고분해능(High-Resolution) 기법의 관한 연구 - 고분해능기법과 표준기법 비교 - (A Study on High-Resolution Technique in MRI Scan for Cerebral Aneurysm Disease -Comparison between High-Resolution Technique and Standard Technique-)

  • 최성현;구은회;황선광;이강원;이종웅
    • 대한디지털의료영상학회논문지
    • /
    • 제14권1호
    • /
    • pp.7-12
    • /
    • 2012
  • The purpose of this study was to examine usefulness of 3T equipment-based time-of-flight magnetic resonance angiography (3T-TOF MRA) by comparing standard technique (ST) with high resolution technique (HRT) in evaluation of cerebral blood vessel. The 3T-TOF MRA was performed for 31 patients who were suspected of having cerebrovascular disease from March to July 2010. For evaluation of cerebral blood vessel, classification was conducted randomly: group I that included vertebral artery and basilar artery, group II that ranged from 2.5cm before basin part of common carotid artery to basin part of internal and external carotid arteries and to genu part of internal carotid artery, group III that ranged from vertebral part of internal carotid artery to the first basin art of anterior and middle cerebral through education recognizes the importance of dose reduction and examine if their efforts and further reduce patient dose could achieve optimization of the medical exposure is considered.

  • PDF

코발트-60 원격치료기를 이용한 전신 방사선 조사에서 선량율의 차이에 따른 급성효과 (Acute Response to Co-60 Total Body Irradiation (TBI) With 600 cGy at 3 Different Does Rates in the Mice)

  • 강철훈;김성규;신세원;김명세
    • Radiation Oncology Journal
    • /
    • 제8권2호
    • /
    • pp.151-154
    • /
    • 1990
  • 영남대학교 의과대학 치료방사선과학교실에서는 코발트-60원격치료기를 이용하여 80마리의 ICR 백서를 대상으로 서로다른 세가지 선량율로 600 cGy 단일조사를 시행한뒤 9주일동안 체중 및 말초혈액소견의 변화를 추적조사한 결과 다음과 같은 성적을 얻었다. 1. 체중변화는 선량율에 상관없이 조사 1주일부터 감소하여 6-7주일부터 치료전의 체중까지 회복 되었다. 2. 혈색소의 변화는 전 추적조사기간에 걸쳐 변화가 없었다. 3. 말초 혈액내의 백혈구의 총수는 조사 1주일부터 3주일까지 형태학적 구분이 안되는 수개의 세포만이 인지되었고 4주일부터 호중구의 회복이 임파구에 비해서 현저하였으며 8-9주일부터 조사전의 상태로 완전 회복되었다. 이상의 결과를 토대로 보다 다양한 실험을 거친후 저선량율 전신조사의 가장 큰 단점인 장시간의 조사로 인한 기계의 무리와 환자 위치고정의 해결을 위하여 분당 선량율을 15 cGy까지 올릴 수 있으리라 기대된다.

  • PDF

Preliminary Application of Synthetic Computed Tomography Image Generation from Magnetic Resonance Image Using Deep-Learning in Breast Cancer Patients

  • Jeon, Wan;An, Hyun Joon;Kim, Jung-in;Park, Jong Min;Kim, Hyoungnyoun;Shin, Kyung Hwan;Chie, Eui Kyu
    • Journal of Radiation Protection and Research
    • /
    • 제44권4호
    • /
    • pp.149-155
    • /
    • 2019
  • Background: Magnetic resonance (MR) image guided radiation therapy system, enables real time MR guided radiotherapy (RT) without additional radiation exposure to patients during treatment. However, MR image lacks electron density information required for dose calculation. Image fusion algorithm with deformable registration between MR and computed tomography (CT) was developed to solve this issue. However, delivered dose may be different due to volumetric changes during image registration process. In this respect, synthetic CT generated from the MR image would provide more accurate information required for the real time RT. Materials and Methods: We analyzed 1,209 MR images from 16 patients who underwent MR guided RT. Structures were divided into five tissue types, air, lung, fat, soft tissue and bone, according to the Hounsfield unit of deformed CT. Using the deep learning model (U-NET model), synthetic CT images were generated from the MR images acquired during RT. This synthetic CT images were compared to deformed CT generated using the deformable registration. Pixel-to-pixel match was conducted to compare the synthetic and deformed CT images. Results and Discussion: In two test image sets, average pixel match rate per section was more than 70% (67.9 to 80.3% and 60.1 to 79%; synthetic CT pixel/deformed planning CT pixel) and the average pixel match rate in the entire patient image set was 69.8%. Conclusion: The synthetic CT generated from the MR images were comparable to deformed CT, suggesting possible use for real time RT. Deep learning model may further improve match rate of synthetic CT with larger MR imaging data.

블라인드 테스트를 통한 요추 검사 시 조사 조건의 최적화 연구 (A Study on the Optimization of Exposure condition at Lumbar projection Using Blind Test)

  • 박지군;김교태;윤인찬;최일홍;정형진;강상식;노시철;정봉재
    • 한국방사선학회논문지
    • /
    • 제7권6호
    • /
    • pp.389-395
    • /
    • 2013
  • 본 연구에서는 일반 촬영 검사 부위 중 조사 조건이 가장 높은 요추 검사에서, 최적의 조사 조건에 대하여 알아보고자 하였다. 이를 위해 통계적으로 많이 이용하고 있는 조사 조건을 기준으로 선정하였고, 선량 변화 인자를 적용한 실험군을 선정하였으며, 환자선량 권고량을 활용하여 임상에 적합한 실험군을 선별하였다. 블라인드 테스트는 전문의 및 방사선사 10명에 의해 수행되었고, 결과 최적화된 조사 조건에서, 전후 방향 검사의 경우 2.09 mGy, 측방향 검사의 경우 4.42 mGy, 사방향 검사의 경우 3.65 mGy 만큼의 선량 저감화가 가능할 것으로 사료된다. 차후에는 환자의 상태에 따른 조사 조건의 최적화 연구가 수행되어야 할 것으로 사료된다.

복부 단순촬영의 이상적 영상구현을 위한 F. S system과 C.R system의 촬영조건 비교분석 (The Comparative Analysis of Exposure Conditions between F/S and C/R System for an Ideal Image in Simple Abdomen)

  • 손상혁;송영근;김제봉
    • 대한디지털의료영상학회논문지
    • /
    • 제9권1호
    • /
    • pp.37-43
    • /
    • 2007
  • I. 목적 : 본 연구에서는 복부의 이상적 영상 구현을 위한 Film Screen (F.S) System과 Computed Radiography(C.R) System의 촬영조건의 차이를 비교 분석해 보고, C.R system에서 촬영조건 변화에 따른 영상의 특성을 분석함으로써, C.R 환경에서 촬영조건 설정의 중요성을 살펴보고자 한다. II. 대상 및 방법 : F.S system에서 촬영 조건을 70kVp로 고정시키고, mAs를 단계적으로 변화시켜 복부 단순겸사를 시행하여 영상을 획득한 후, 진단방사선과 전문의와 방사선사로 구성된 영상평가 팀의 정량적, 정성적 분석을 통하여 F.S system 최적의 영상을 선정하였다. 동일 환자를 대상으로 C.R system 에서 위와 동일한 방법으로 영상을 획득한 후, F.S system과 C.R system의 영상의 특성곡선(Characteristic Curves)을 비교분석하고, C.R system에서 촬영조건 변화에 따른 복부 장기의 농도변화 및 영상의 특정을 비교 평가하였다. 마지막으로, F.S system과 C.R system의 최적의 영상 획득을 위한 촬영조건의 차이를 비교 분석하고, C.R 환경에서 촬영조건의 중요성을 살펴보았다. III. 결과 : F.S system에서 영상평가팀의 평가를 통하여 선택된 최적 영상의 촬영 조건은 70kVp, 20mAs로 나타났다. C.R system에서는 촬영조건 12mAs, 70kVp에서 복벽과 직접노출구역의 농도 차이가 최대인, 진단적 가치가 높은 영상을 얻을 수 있었다. C.R system에서는 (70kVp로 고정)변화한 mAs량(3.2mAs, 8mAs, 12mAs, 16mAs, 20mAs)에 상관없이 복부 장기는 거의 통일한 농도를 나타냈으며 12mAs 기준으로 노출 조건의 감소 또는 증가에 따라서 복벽과 직접노출부분의 명확한 구분이 불가능하였으며, mAs량이 낮아질수록 양자반점(Quantum Mottle)으로 인한 artifact는 증가함을 볼 수 있었다. IV. 결론 : 위의 실험 결과 본원 system의 복부단순검사에서는 C.R system 사용 시 F.S system 보다 촬영 조건을 약 40% 감소시킬 수 있었다. C.R환경에서 x-ray장치 Image processing 장치, 자동 감도조절(EDR : exposure data recognition processing) 장치, PACS 등 사용하는 장비들의 특성을 분석하여 적정 노출조건을 재설정한다면, 최소의 피폭선량으로 최대의 영상정보를 지닌 진단적 가치가 높은 영상의 획득이 가능하다고 사료된다.

  • PDF

외과환자에 발생한 급성신부전의 진단과 치료 (Diagnosis and Management of Acute Renal Failure in Surgical Patient)

  • 권굉보
    • Journal of Yeungnam Medical Science
    • /
    • 제1권1호
    • /
    • pp.13-23
    • /
    • 1984
  • Acute renal failure refers to a rapid reduction in renal function that usually occurs in an individual with no known previous renal disease. Development of a complication of acue renal failure in critically ill surgical patients is not unusual, and it causes high morbidity and mortality. Acute renal failure can be divided as Pre-renal (functional), Renal (organic), and Post-renal (obstructive) azotemia according to their etiologies. Early recognition and proper correction of pre-renal conditions are utter most important to prevent an organic damage of kidney. These measures include correction of dehydration, treatment of sepsis, and institution of shock therapy. Prolonged exposure to ischemia or nephrotoxin may lead a kidney to permanent parenchymal damage. A differential diagnosis between functional and organic acute renal failure may not be simple in many clinical settings. Renal functional parameters, such as $FENa^+$ or renal failure index, are may be of help in these situations for the differential diagnosis. Provocative test utilyzing mannitol, loop diuretics and renovascular dilators after restoration of renal circulation will give further benefits for diagnosis or for prevention of functional failure from leading to organic renal failure. Converting enzyme blocker, dopamine, calcium channel blocker, and propranolol are also reported to have some degree of renal protection from bioenergetic renal insults. Once diagnosis of acute tubular necrosis has been made, all measures should be utilized to maintain the patient until renal tubular regeneration occurs. Careful regulation of fluid, electrolyte, and acid-base balance is primary goal. Hyperkalemia over 6.5 mEq/l is a medical emergency and it should be corrected immediately. Various dosing schedules for medicines excreting through kidney have been suggested but none was proved safe and accurate. Therefore blood level of specific medicines better be checked before each dose, especially digoxin and Aminoglycosides. Indication for application of ultrafiltration hemofilter or dialysis may be made by individual base.

  • PDF

Bisphosphonate(Zoledronic acid)와 연관된 하악골의 골수염-증례보고 (BISPHOSPHONATE(ZOLEDRONIC ACID) RELATED OSTEOMYELITIS ON MANDIBLE-A CASE REPORT)

  • 이수연;최소영;김진욱;권대근;장현중;김진수;이상한
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제30권4호
    • /
    • pp.395-398
    • /
    • 2008
  • Bisphosphonate are a class of drugs with a chemical structure which inhibit bone resorption, actually used for metastatic bone disease, osteoporosis, Paget's disease and multiple myeloma. Significant complication associated with their use is reported recently : mandibular and maxillary osteomyelitis or osteonecrosis. So we here report our case about the patient who was diagnosed of prostate cancer in 2004 April and treated with bisphosphonate(Zoledronic acid-$Zometa^{(R)}$, Novartis Co.) intravenously every 3 to 4weeks at a dose of 4mg to prevent bone metastasis, and also, the patient who came to the hospital due to the bony exposure of mandible and pain in 2006 November and was diagnosed osteomyelitis of mandible as a result of biopsy, bone scan, PET CT examination.

흉부촬영(胸部撮影)에서 증감지(增感紙)-필름계의 선질변화(線質變化)에 따른 감도(感度)와 화질에 관(關)한 연구(硏究) (Image and Exposure Dose in Accordance with Radiation Quality on Plain Chest Radiography)

  • 김정민;김동현;임태랑;석전유치;전전미향;앵정달야
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제15권1호
    • /
    • pp.65-78
    • /
    • 1992
  • Routine chest radiography is generally imaged by high voltage technique but some radiological technologists use low voltage for imaging. High voltage is usually said between $120\;kV{\sim}140\;kV$. Some RTs like using heavy filtration but others seldom like using it. However which is better for use calcium tungustate film screen system or ortho system and high contrast film or wide latitude c-type film for the exculusive use of chest radiography. We could not make a decision which is ideal method for use. In my opinion any method is not always exellent for chest radiography. In my experiments that I had at Kaken hospital in Japan last year I expect to keep the balance between image quality and diagnostic range and to reduce radiation dose for patients. My experiments are as follows. 1. We have looked into system characteristics(speed and contrast) in accordance with kVp($80{\sim}140$) and added filter($no{\sim}1/16\;VL$) in three screen film systems(BX3+CRONEX4, SRO750+MGH, SRO750+MGL). 2. We have looked into skin dose and film dose with same D=1.8 lung field density in accordance with kVp($80{\sim}140$) and added filter($no{\sim}1/16\;VL$) in three screen film systems. 3. We have compared with the evaluation between correlation of physical image quality(MTF) and optical diagnostic capability. Result are follows. 1. Speed of BX3+CRONEX4 became higher in accodance with kVp and thickness of filter but speed of ortho system was not as like regular system. Thicker filter diminished the speed over 100 kV range in SRO750+MGL. In case of SRO750+MGH speed of 1/16VL filter was looked into lower than speed of 1/4VL filter. Sensitivity of ortho system depends on tube voltage and added filter. 2. Skin dose has been detected $225\;{\mu}Gy{\sim}66\;{\mu}Gy$ in BX3+CRONEX4 from 80 kV, no filter to 140 kV, 1/16VL filter. SRO750+MGH could reduce the patient dose $1/2{\sim}1/3$ level in comparison to that of BX3+CRONEX4. 3. The higher kV was the worse MTF became the thicker filter was the worse MTF became too. MTF of BX3+CRONEX4 was detected better than MTF of SRO750+MGH but SRO750+MGH's optical detectability of small lesion in lung field came out better than that of BX3+CRONEX4. Conclusion Recently routine chest radiography is generally imaged by high voltage but it seems to be there are some questions in using of film screen combination. In high voltage chest radiography the subject contrast will come down that means latitude become wider. In this case if we select the low contrast film screen system(C or L type) the film contrast will fall down extremly and detectability of small lesion will be deteriorated. Wide latitude C, L type film has a merit of high detectability on mediastinum. Furthermore high contrast film screen system has the advantage to keep the high contrast in low density region as like mediastinum and heart shadow. Therefore in low subject contrast high voltage chest radiography we would rather choose the high contrast film screen system(H type) I think. From a view point of patient dose detectability of mediastinum and lung field. The optimum technical facter was found out 120 kV, 1/16VL filter : BX3+CRONEX4, 140 kV, 1/4VL filter : SRO750+MGH, 100 kV, 1/4VL filter : SRO750+MGL.

  • PDF

열형광선량계를 이용한 16-MDCT와 64-MDCT의 관상동맥 CT 혈관조영술 시 선량평가 (Evaluation of the dose of 16-MDCT and 64-MDCT in case of Coronary Artery CT Angiography using Thermoluminescence Dosimeter)

  • 김상태;최지원;조정근
    • 한국콘텐츠학회논문지
    • /
    • 제10권6호
    • /
    • pp.336-343
    • /
    • 2010
  • 관상동맥 CT 혈관조영술(coronary artery CT angiography)은 작은 스캔 길이에도 불구하고 방사선량이 높다. 3차원 영상을 얻기 위해서 다른 방사선 검사보다 고 선량(high dose)이 조사되는 CT촬영으로 인한 방사선 피폭이 중요한 문제로 대두되고 있어 MDCT의 이용 시 장기선량에 대한 고찰이 필요하다. 16-MDCT와 64-MDCT에서 동일 프로토콜의 관상동맥 CT 혈관조영술을 대상으로 16-MDCT와 64-MDCT에서의 주요장기의 흡수선량을 측정하여 주선속 내외의 주요장기 흡수선량 및 유효선량의 차이를 비교하였다. 그 결과 관상동맥 CT 혈관조영술시 받는 흡수선량이 큰 조직 순으로 열거하면 16-MDCT에서 심장, 위, 간, 췌장, 신장, 비장, 대장, 폐, 소장, 갑상선, 난소, 방광, 안와 순으로 $0.538{\pm}0.026(Mean{\pm}SD,\;p<0.05)mGy{\sim}71.316{\pm}4.316mGy$의 흡수선량 분포를 나타냈으며 64-MDCT에서는 심장, 위, 췌장, 비장, 간, 신장, 소장, 대장, 폐, 갑상선, 난소, 방광, 안와 순으로 $0.87{\pm}0.01mGy{\sim}115.26{\pm}1.59mGy$의 흡수선량 분포를 나타내 16-MDCT와는 그 분포 형태가 다소 다르게 나타났다. 관상동맥 CT 혈관조영술 1회 촬영으로 받는 환자선량이 16-MDCT에서 심장을 기준으로 한 흡수선량이 $71.316{\pm}4.316mGy$였으며 64-MDCT에서는 $115.26{\pm}1.59mGy$로 나타났고 유효선량은 16-MDCT에서 7.41 mSv, 64-MDCT에서 12.11 mSv로 나타났다. 상대적으로 스캔길이와 면적이 비교적 큰 뇌 CT 2.8 mSv, 안면-도관 CT 0.8 mSv, 가슴 CT 5.7 mSv, 골반 CT 7.2 mSv, 복부와 골반 CT에서 14.4 mSv임을 감안할 때 스캔구간이 심장에 제한된 13 cm의 스캔길이를 고려하면 상당히 높다. 그러나 주어진 진료 목적을 달성하면서 환자의 선량을 감축할 수 있다면 그러한 노력을 게을리 하지 말아야 할 것이다.

X선 촬영실에서 방호복 유무에 따른 공간산란선량의 측정 비교 (Measurement of Comparison to Scattering Dose Space According to the Presence or Absence of Protective Clothing in the X-ray Room)

  • 허예지;김교태;조창훈;강수만;박지군;강상식;노시철;정봉재
    • 한국방사선학회논문지
    • /
    • 제6권4호
    • /
    • pp.313-320
    • /
    • 2012
  • 현재 의료기관은 의학 기술의 발전과 더불어 건강에 대한 관심이 고조됨에 따라 방사선 발생장치의 이용이 급증하고 있다. 방사선으로 인해 환자가 받는 직접적인 피폭을 가능한한 줄이는 목적도 중요하지만 촬영시 공간 내에서 받을 수 있는 간접적인 피폭을 줄여 의료업에 종사하는 의료인, 방사선 작업종사자 및 보호자의 피폭을 줄여야 한다. 엑스선 촬영실에서는 방사선작업종사자 및 보호자에게 방호복의 착용을 권고하고 있으나 불가피하게 방사선작업종사자 및 보호자가 환자의 촬영 보조를 할 경우, 방호복 착용에 의한 중량감 및 불편함 때문에 방호복 착용이 등한시 되고 있다. 이에 본 연구에서는 방호복 유무에 따라 공간산란선량을 측정하고 거리, 가로면 각도 및 높이에 따라 측정함으로써 방호복 착용의 중요성을 알아보고자 하였다.