• Title/Summary/Keyword: patient exposure

Search Result 900, Processing Time 0.029 seconds

Comparisons and Measurements the Dose Value Using the Semiconductor Dosimeter and Dose Area Product Dosimeter in Skull, Chest and Abdomen (두개부, 흉부, 복부검사 시 반도체 선량계와 면적 선량계를 이용한 선량 값의 측정 및 비교)

  • Kim, Ki-Won;Son, Jin-Hyun
    • Journal of radiological science and technology
    • /
    • v.38 no.2
    • /
    • pp.101-106
    • /
    • 2015
  • Recently, There has been a growing interests in exposure dose to the patient who take a examination using radiation. The radiological technologists should be concerned about the exposure dose to patients and make an efforts to reduce the patient dose without decreasing the image quality. In the case of foreign, the exposure dose of general X-ray examination have been managed by standard value of exposure dose using dose area product (DAP) and entrance surface dose (ESD) dosimeter. This study is to compare DAP and ESD in skull anterior posterior (AP), chest posterior anterior (PA), and abdomen AP projections of phantom by using DAP and ESD dosimeter. In the results, there were no differences between DAP and ESD dosimeter.

Dose assessment according to Differences in the Content of Iodine in Contrast Media used in Interventional Procedure (중재적 시술에 사용하는 조영제의 요오드(53I) 함유량 차이에 따른 피폭선량 평가)

  • Bak, Hyeok;Jeon, Ju-Seob;Kim, Yong-Wan;Jang, Seong-Joo
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.3
    • /
    • pp.337-345
    • /
    • 2014
  • The purpose of this study is to evaluate exposure dose and absorbability according to differences in the content of iodine in contrast media used in interventional procedure and angiography. There were 7 levels of iodine content as 240, 270, 300, 320, 350, 370, and 400 I $mg/m{\ell}$. The higher iodine content was, the more elevated exposure dose and absorbability were. The output dose was about 8.5% from iodine content with 350I $mg/m{\ell}$ higher than that with 270 I $mg/m{\ell}$ in TACE. These results mean that contrast media can have an effect on patient's exposure dose and high iodine content contrast media results in elevation of patient's exposure dose.

Palate bone exposure from flexible denture: a case report (탄성의치에 의한 구개부 골노출 증례)

  • Jin, Soo-Yoon;Kim, Mi-Gyeong;Kim, Hee-Jung;Lee, Gyeong-Je
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.1
    • /
    • pp.19-24
    • /
    • 2017
  • Recently, flexible denture is widely used with some advantages such as esthetics, flexibility and biocompatibility. However, there is an opposite opinion about stability because of the movement of denture by the material's flexibility. As the denture moves to tissue surface during mastication, it irritates the supporting tissue. It can lead to trauma and rapid resorption of residual ridges if this irritation lasts for a long time. In this case, the patient has used flexible denture with insufficient stability, retention and support for several years and thus continuous irritation of the supporting tissue resulted in palate bone exposure. The patient discomfort and palate bone exposure underwent improvements by the new denture with stability and retention. A careful case selection for flexible denture, regular checkup and proper treatment are necessary to prevent the side effects.

A Survey of the Management of Patient Dose at Medical Center (의료기관의 환자 피폭선량 관리 실태조사)

  • Jeon, Go-Eun;Jin, Gye-Hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.3 no.1
    • /
    • pp.23-28
    • /
    • 2009
  • Medical radiation therapy using radioactive isotope I-131 is an extremely critical part of nuclear medicine. It is important to evaluate patients' radiation exposure dose for the safe handling of radiation in the medical area. Cautions related to patients' exposure to radiation are as follows. First, the dose should not exceed the level required for medical purpose. Second, unnecessary exposure should be avoided. Third, it should be considered carefully first whether the same medical purpose is attainable without the use of radiation. For these purposes, we need to evaluate patients' radiation exposure dose. Thus, in order to promote the safety of patients in medical wards, this study sampled air using an air sampler and measured the radioactivity of the sample using a gamma counter. According to the results of measuring I-131 in medical wards, the highest level, the average and the lowest level were $404.11Bq/m^3$, $228.27Bq/m^3$ and $126.17Bq/m^3$, respectively.

  • PDF

Tobacco Smoke Exposure and Breast Cancer Risk in Thai Urban Females

  • Pimhanam, Chaisak;Sangrajrang, Suleeporn;Ekpanyaskul, Chatchai
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.17
    • /
    • pp.7407-7411
    • /
    • 2014
  • The incidence of urban female breast cancer has been continuously increasing over the past decade with unknown etiology. One hypothesis for this increase is carcinogen exposure from tobacco. Therefore, the objective of this study was to investigate the risk of urban female breast cancer from tobacco smoke exposure. The matched case control study was conducted among Thai females, aged 17-76 years and living in Bangkok or its surrounding areas. A total of 444 pairs of cases and controls were recruited from the Thai National Cancer Institute. Cases were newly diagnosed and histologically confirmed as breast cancer while controls were selected from healthy women who visited a patient, matched by age ${\pm}5$ years. After obtaining informed consent, tobacco smoke exposure data and information on other potential risk factors were collected by interview. The analysis was performed by conditional logistic regression, and presented with odds ratio (ORs) and 95% confidence intervals(CI). From all subjects, 3.8% of cases and 3.4% of controls were active smokers while 11.0% of cases and 6.1% of controls were passive smokers. The highest to lowest sources of passive tobacco smoke were from spouses (40.8%), the workplace (36.8%) and public areas (26.3%), respectively. After adjusting for other potential risk factors or confounders, females with frequent low-dose passive smoke exposure (${\leq}7$ hours per week) from a spouse or workplace had adjusted odds ratio 3.77 (95%CI=1.11-12.82) and 4.02 (95%CI=1.04-15.50) higher risk of breast cancer compared with non-smokers, respectively. However, this study did not find any association of breast cancer risk in high dose passive tobacco smoke exposure, or a dose response relationship in cumulative passive tobacco smoke exposure per week, or in the active smoker group. In conclusion, passive smoke exposure may be one important risk factor of urban female breast cancer, particularly, from a spouse or workplace. This risk factor highlights the importance of avoiding tobacco smoke exposure as a key measure for breast cancer prevention and control.

Analysis of Patients with Acute Industrial Toxic Exposure at an Emergency Department in an Industrial Complex (공단밀집지역에 위치한 일개 응급의료센터에 내원한 급성산업중독환자에 대한 분석)

  • Shin, Jun-Hyun;Moon, Sung-Woo;Baek, Seung-Won;Lim, Sung-Ik;Yoon, Young-Hun;Lee, Sung-Woo;Hong, Yun-Sik
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.6 no.2
    • /
    • pp.117-122
    • /
    • 2008
  • Purpose: Surveys on poisoning usually involves intoxication rather than inhalation, skin contact, etc. Therefore, we examined the characteristics of patients who visited the emergency department in an industrial complex after acute industrial exposure to toxic materials. Methods: Medical records of patients exposed to toxic materials in the work places from April, 2006, to March, 2008, were analyzed retrospectively. Inhalation patients due to fire were excluded. Results: Subjects included 66 patients, with a mean age of $35.4{\pm}10.9$ years, mostly men (91%). Toxicity occurred in 51 patients (77%) by contact, 15 patients (23%) by inhalation, and none by oral ingestion. For toxic materials, 10 patients were exposed to hydrofluoric acid, 8 to hydrochloric acid, 7 to sodium hydroxide, 7 to metals, and others. The face and hands were the most frequent exposure site by contact. Most exposures were caused by accidents, with 29 cases (42%) exposed because of carelessness or not wearing protective equipment. Most complaints were pain on exposure site, but 7 of the inhalation patients complained of dyspnea. The majority of patients with contact exposure were discharged after wound care or observation. After inhalation exposure, 1 patient died and 5 patients were admitted to the intensive care unit. Conclusion: Major causes of workplace exposure were not wearing protective equipment or carelessness. Although contact exposures are usually benign, cautious observation and management are required in patients with inhalation exposure.

  • PDF

Image Evaluation for Optimization of Radiological Protection in CBCT during Image-Guided Radiation Therapy (영상유도 방사선 치료 시 CBCT에서 방사선 방호최적화를 위한 영상평가)

  • Min-Ho Choi;Kyung-Wan Kim;Dong-Yeon Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.305-314
    • /
    • 2023
  • With the development of medical technology and radiation treatment equipment, the frequency of high-precision radiation therapy such as intensity modulation radiation therapy has increased. Image-guided radiation therapy has become essential for radiation therapy in precise and complex treatment plans. In particular, with the introduction of imaging equipment for diagnosis in a linear accelerator, CBCT scanning became possible, which made it possible to calibrate and correct the patient's posture through 3D images. Although more precise reproduction of the patient's posture has become possible, the exposure dose delivered to the patient during the image acquisition process cannot be ignored. Radiation optimization is necessary in the field of radiation therapy, and efforts to reduce exposure are necessary. However, when acquiring 3D CBCT images by changing the imaging conditions to reduce exposure, there should be no image quality or artefacts that would make it impossible to align the patient's position. In this study, Rando phantom was used to scan and evaluate images for each shooting condition. The highest SNR was obtained at 100 kV 80 mA 25 ms F1 filter 180°. As the tube voltage and tube current increased, the noise decreased, and the bowtie filter showed the optimal effect at high tube current. Based on the actual scanned images, it was confirmed that patient alignment was possible under all imaging conditions, and that image-guided radiation therapy for patient alignment was possible under the condition of 70 kV 10 mA 20 ms F0 filter 180°, which showed the lowest SNR. In this study, image evaluation was conducted according to the imaging conditions, and low tube voltage, tube current, and small rotation angle scan are expected to be effective in reducing radiation exposure. Based on this, the patient's exposure dose should be kept as low as possible during CBCT imaging.

Comparison of the Breast Dose based on the Existence of the Bismuth Breast Protection Shield for Automatic Exposure Control and Manual Exposure Control with the Coronary Artery CT Angiography

  • Kim, Sang-Tae;Kang, Sang-Koo;Kim, Chong-Yeal
    • International Journal of Contents
    • /
    • v.7 no.4
    • /
    • pp.103-107
    • /
    • 2011
  • The effective dose and the organ absorbed dose, which are given to a breast in the cases of using and not using the bismuth breast protection shield for the protection of a breast with the coronary artery CT angiography, have been measured and compared for the manual exposure control (MEC)and the automatic exposure control (AEC). In the cases of using and not using the bismuth breast protection shield, it has been found that the measured dose shows the reduction of about 23 to 26% for the MEC and about 22 to 25% for the AEC when the shield is used compared to the case of not using it. By comparing the shield and non-shield cases for the AEC and the MEC, it can be said that the value measured by carrying out the scanning process with the AEC mode has decreased by about 24 to 30% compared to the case of applying the MEC mode. Such a result shows that it is recommended to use the AEC mode for the reduction of the patient's exposure dose during the CT examination.

Study of radiation exposure on human body using of Computed Tomography (전산화단층촬영 검사 시 인체에 미치는 방사선피폭선량 분석연구)

  • Seon, Jong-Ryoul;Yoo, Se-Jong
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.4
    • /
    • pp.193-198
    • /
    • 2015
  • This study analyzed the total number of 19,636 patients and radiation technologists, 11,433 of male and 8,203 of female by examined body parts, age, types of detectors, the using contrast enhancement and working condition of the technologists, regular staffs or rotation-duty staffs, based on the K-DOS program distributed by FDA with the DLP value of diagnostic evaluation. The result shows that the effective radiation dose was 0.7mSv~41.7mSv for each region and male patients had more radiation exposure than females. And the amount of exposure was also affected by the types and the method of detectors. Furthermore, the regular staffs took the role of helping the patient to get reduced amount of radiation exposure than rotation duty-staffs. Computed tomography (CT) use has increased dramatically over the past several decades. In this reason, to support the patients and the workers' health in the field, the hospitals should apply specialized regular working radiation technologist system and manufacturing companies of those CTs should develop low medical radiation exposure devices.

The Extensor Digitorum Brevis Muscle Island Flap for Soft Tissue Loss Around the Ankle and Distal Foot (단족지 신전근 도상 피판에 의한 족부 및 족관절부의 연부조직 수복)

  • Choi, Soo-Joong;Jun, Byoung-Hyuk
    • Archives of Reconstructive Microsurgery
    • /
    • v.14 no.2
    • /
    • pp.131-137
    • /
    • 2005
  • The extensor digitorum brevis (EDB) muscle island flap is a reliable, safe method for coverage of foot and ankle. There are many variation in approach such as curvilinear, zigzag, L-shaped or vertical longitudinal incision for exposure of the EDB muscle. These approaches use only single incision excluding the distal incision for exposure of the distal tendon. Since dorsalis pedis artery vascular bundle and sinus tarsi branch of the lateral tarsal artery both requires careful dissection, single incision alone may cause not only difficulty in exposure but also skin sloughing at donor site. So we tried to modify the approach into two parallel longitudinal incision, one for dorsalis pedis vascular bundle and the other for sinus tarsi branch exposure. The author treated 9 patient with EDB muscle flap. We used single incision in six patients, and two parallel incision in three patients. All the flap survived. In two parallel incision group, dissection was more easy and rapid. So we would like to suggest that two parallel longitudinal incision approach is better method than the single incision technique for exposure of the EDB muscle flap.

  • PDF