• Title/Summary/Keyword: patient' body movement

Search Result 128, Processing Time 0.024 seconds

Schwannoma Originating from Infraorbital Nerve (안와하신경에서 기원한 신경초종의 치험례)

  • Ha, Won;Lee, Ji Won;Choi, Jae Il;Yang, Wan Suk;Kim, Sun Young
    • Archives of Craniofacial Surgery
    • /
    • v.14 no.1
    • /
    • pp.61-64
    • /
    • 2013
  • Schwannomas are well-differentiated solitary benign tumors that originate from the schwann cells of the nerve sheath. They can readily occur in the head and neck regions, but the schwannoma originating from the infraorbital nerve is extremely rare and usually painless, slow-growing, and without specific symptoms. The author experienced a rare case of infraorbital schwannoma, which was completely removed through the intraoral approach. A 20-year-old woman was admitted to our hospital for a painless, solid and circular mass located on the right infraorbital region. The eyeball movement and visual field were normal. There was no globe displacement or proptosis. Preoperative computed tomography demonstrated $13{\times}10{\times}5mm$-sized soft tissue mass. On March 2011, the mass was removed through an intraoral approach. On histopathological examination, the gross specimen consisted of a smooth, well-encapsulated and light yellowish solid mass, measuring $12{\times}7{\times}5mm$. Microscopically, it presented a typical manifestation of schwannoma with Antoni A area with Verocay body, and Antoni B area on H&E stain. The result of the immunohistochemical staining was positive for the S-100 protein. The patient had hypoesthesia of the nasal septum and vestibule in the postoperative period, and this finding confirmed that the internal nasal branch of infraorbital nerve was the nerve in which the schwannoma originated. Infraorbital schwannomas are very rare and must be included in the differential diagnosis of the orbital masses inferior to the eyeball. In the case of early diagnosis, the small-sized infraorbital schwannomas can be completely removed without any scar through an intraoral approach.

Treatment of a Huge Aneurysmal Bone Cyst of the Talus through a Segmental Bone Graft of the Tricortical Bone: A Case Report (삼피질골의 분절성형 골이식을 통한 거골 거대 동맥류성 골낭종의 치료 1예: 증례 보고)

  • Lee, Seung-Jin;Lee, Hyobeom;Kim, Gab-Lae;Kim, Donghyeon
    • Journal of Korean Foot and Ankle Society
    • /
    • v.25 no.4
    • /
    • pp.185-189
    • /
    • 2021
  • An aneurysmal bone cyst (ABC) can occur in many parts of the human body, but a primary ABC of the talus is extremely rare. ABCs are benign, but aggressively growing tumors that usually occur in the first two decades of life. Patients mainly complain of pain, limited movement of the involved joint or a palpable mass. Pain may worsen suddenly because of pathological fractures. If not treated properly, ABC has a risk of local recurrence, followed by the destruction of the joint and a significant functional deficit. While the complete removal of the bone tumor is essential, it is also important to treat the resultant bone defect after removal. The talus has an important part to play in weight-bearing. Therefore, an appropriate bone graft is required for large bone defects that occur after an ABC removal from the talus. We report a primary ABC of the talus in a 28-year-old male that was treated by curettage and a bone pillar pattern graft of autologous tricortical iliac crest bone. The patient had an excellent functional outcome with early weight-bearing, and there was no recurrence at 16 months of follow-up.

Evaluation Tools for Patients with Neurologic Disorders Based on the ICF Model: A Survey of Korean Physical Therapists (ICF 모델 기반 신경계 환자 물리치료 평가 도구 사용 조사)

  • Lee, Ji-ah;Woo, Yong-Keun;Won, Jong-Im;Kim, Su-jin
    • PNF and Movement
    • /
    • v.20 no.3
    • /
    • pp.359-370
    • /
    • 2022
  • Purpose: Physical therapists are required to properly choose the most appropriate treatment for each patient within the framework of the International Classification of Functioning, Disability, and Health (ICF model). The aims of this study were to determine whether neurological physical therapists in clinical settings in South Korea know about the ICF model and to investigate the current trends of outcome measures (OMs) used by them. Methods: Two hundred and one physical therapists who worked with patients with neurological disorders participated in this study. The survey was conducted via e-mail and asked about commonly used OMs and the considerations for selecting OMs. Results: All physical therapists involved in this study responded completely, and 45.8% of participants learned about the ICF model, while 37.3% understood the detailed information related to the ICF model. The rest of the participants did not know or just heard about the ICF model. The most frequently used tools at the body function/structure level were the Range of Motion (98%), Manual Muscle Test (97%), Berg Balance Scale (83.1%), and Modified Ashworth Scale (70.6%) when allowing repetition. At the activity level, the 10-meter walk test (71.1%), 6-minute walk test (54.2%), and Functional Ambulatory Category (43.3%) were used, while the Activity-Specific Balance Confidence Scale (23.9%) was used at the participation level. There was a positive relationship between the number of tools used and years of work, as well as the level of understanding of the ICF model. Conclusion: The results of this study suggest that it is necessary to learn the ICF model in a clinical setting. In addition, the medical system needs to be modified to encourage physical therapists in South Korea to use proper OMs within the ICF model.

Comparative Analysis of Absorption Doses between Exposed and Unexposed Area on Major Organs During CT Scan (전산화 단층촬영시 주선속내 외의 주요장기 흡수선량 비교분석)

  • 사정호;서태석;최보영;정규회
    • Progress in Medical Physics
    • /
    • v.11 no.1
    • /
    • pp.59-71
    • /
    • 2000
  • It is possible to obtain a fast CT scan during breath holding with spiral technique. But the risk of radiation is increased due to detailed and repeated scans. However, the limitation of X-ray doses is not fully specified on CT, yet. Therefore, the purpose of the present study is to define the limitation of X-ray doses on CT The CT unit was somatom plus 4. Alderson Rando phantom, Solenoid water phantom, TLD, and reader were used. For determining adequate position and size of organs, the measurement of distance(${\pm}$2mm) from the midline of vertebral body was performed in 40 women(20~40 years). On the brain scan for 8:8(8mm slice thickness, 8mm/sec movement velocity of the table) and 10:10(10mm slice thickness, 10mm/sec movement velocity of the table) methods, the absorption doses of exposed area of the 10:10 were slightly higher than those of 8:8. The doses of unexposed uterus were negligible on the brain scan for both 8:8 and 10:10. On the chest scan for 8:8, 8:10(8mm slice thickness, 10mm/sec movement velocity of the table), 10:10, 10:12(10mm slice thickness, 12mm/sec movement velocity of the table) and 10:15(10mm slice thickness, 15mm/sec movement velocity of the table) methods, 8:8 method of the absorption doses of exposure area was the most highest and 10:15 method was the most lowest. The absorption doses of 8:10 method was relatively lower than those of the other methods. In conclusion, the 8:10 method is the most suitable to give a low radiation burden to patient without distorting image quality.

  • PDF

Impact of the Planning CT Scan Time on the Reflection of the Lung Tumor Motion (전산화단층촬영 주사시간(Scan Time)이 폐종양운동의 재현성에 미치는 영향 분석)

  • Kim Su Ssan;Ha Sung Whan;Choi Eun Kyung;Yi Byong Yong
    • Radiation Oncology Journal
    • /
    • v.22 no.1
    • /
    • pp.55-63
    • /
    • 2004
  • Purpose : To evaluate the reflection of tumor motion according to the planning CT scan time. Material and Methods : A model of N-shape, which moved aiong the longitudinal axis during the ventilation caused by a mechanical ventilator, was produced. The model was scanned by planning CT, while setting the relative CT scan time (T: CT scan time/ventilatory period) to 0.33, 0.50, 0.67, 0.75, 1.00, 1.337, and 1.537. In addition, three patients with non-small cell lung cancer who received stereotactic radiosurgery In the Department of Radiation Oncology, Asan Medical Center from 03/19/2002 to 05/21/2002 were scanned. Slow (10 Premier, Picker, scan time 2.0 seconds per slice) and fast CT scans (Lightspeed, GE Medical Systems, with a scan time of 0.8 second per slice) were peformed for each patient. The magnitude of reflected movement of the N-shaped model was evaluated by measuring the transverse length, which reflected the movement of the declined bar of the model at each slice. For patients' scans, all CT data sets were registered using a stereotactic body frame scale with the gross tumor volumes delineated in one CT image set. The volume and three-dimensional diameter of the gross tumor volume were measured and analyzed between the slow and fast CT scans. Results : The reflection degree of longitudinal movement of the model increased in proportion to the relative CT scan times below 1.00 7, but remained constant above 1.00 T Assuming the mean value of scanned transverse lengths with CT scan time 1.00 T to be $100\%$, CT scans with scan times of 0.33, 0.50, 0.57, and 0.75 T missed the tumor motion by 30, 27, 20, and $7.0\%$ respectively, Slow (scan time 2.0 sec) and Fast (scan time 0.8 sec) CT scans of three patients with longitudinal movement of 3, 5, and 10 mm measured by fluoroscopy revealed the increases in the diameter along the longitudinal axis Increased by 6.3, 17, and $23\%$ in the slow CT scans. Conculsion : As the relative CT scan time increased, the reflection of the respiratory tumor movement on planning CT also Increased, but remained constant with relative CT scan times above 1.00 T When setting the planning CT scan time above one respiration period (>1.00 T), only the set-up margin is needed to delineate the planning target volume. Therefore, therapeutic ratio can be increased by reducing the radiation dose delivered to normal lung tissue.

Evaluation of Combine IGRT using ExacTrac and CBCT In SBRT (정위적체부방사선치료시 ExacTrac과 CBCT를 이용한 Combine IGRT의 유용성 평가)

  • Ahn, Min Woo;Kang, Hyo Seok;Choi, Byoung Joon;Park, Sang Jun;Jung, Da Ee;Lee, Geon Ho;Lee, Doo Sang;Jeon, Myeong Soo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.201-208
    • /
    • 2018
  • Purpose : The purpose of this study is to compare and analyze the set-up errors using the Combine IGRT with ExacTrac and CBCT phased in the treatment of Stereotatic Body Radiotherapy. Methods and materials : Patient who were treated Stereotatic Body Radiotherapy in the ulsan university hospital from May 2014 to november 2017 were classified as treatment area three brain, nine spine, three pelvis. First using ExacTrac Set-up error calibrated direction of Lateral(Lat), Longitudinal(Lng), Vertical(Vrt), Roll, Pitch, Yaw, after applied ExacTrac moving data in addition to use CBCT and set-up error calibrated direction of Lat, Lng, Vrt, Rotation(Rtn). Results : When using ExacTrac, the error in the brain region is Lat $0.18{\pm}0.25cm$, Lng $0.23{\pm}0.04cm$, Vrt $0.30{\pm}0.36cm$, Roll $0.36{\pm}0.21^{\circ}$, Pitch $1.72{\pm}0.62^{\circ}$, Yaw $1.80{\pm}1.21^{\circ}$, spine Lat $0.21{\pm}0.24cm$, Lng $0.27{\pm}0.36cm$, Vrt $0.26{\pm}0.42cm$, Roll $1.01{\pm}1.17^{\circ}$, Pitch $0.66{\pm}0.45^{\circ}$, Yaw $0.71{\pm}0.58^{\circ}$, pelvis Lat $0.20{\pm}0.16cm$, Lng $0.24{\pm}0.29cm$, Vrt $0.28{\pm}0.29cm$, Roll $0.83{\pm}0.21^{\circ}$, Pitch $0.57{\pm}0.45^{\circ}$, Yaw $0.52{\pm}0.27^{\circ}$ When CBCT is performed after the couch movement, the error in brain region is Lat $0.06{\pm}0.05cm$, Lng $0.07{\pm}0.06cm$, Vrt $0.00{\pm}0.00cm$, Rtn $0.0{\pm}0.0^{\circ}$, spine Lat $0.06{\pm}0.04cm$, Lng $0.16{\pm}0.30cm$, Vrt $0.08{\pm}0.08cm$, Rtn $0.00{\pm}0.00^{\circ}$, pelvis Lat $0.06{\pm}0.07cm$, Lng $0.04{\pm}0.05cm$, Vrt $0.06{\pm}0.04cm$, Rtn $0.0{\pm}0.0^{\circ}$. Conclusion : Combine IGRT with ExacTrac in addition to CBCT during Stereotatic Body Radiotherapy showed that it was possible to reduce the set-up error of patients compared to single ExacTrac. However, the application of Combine IGRT increases patient set-up verification time and absorption dose in the body for image acquisition. Therefore, depending on the patient's situation that using Combine IGRT to reduce the patient's set-up error can increase the radiation treatment effectiveness.

  • PDF

MUSIC THERAPY FOR ADOLESCENTS WITH CONDUCT DISORDER (품행장애 청소년의 음악치료 사례연구)

  • Jhin, Hea-Kyung;Kwon, Hea-Kyung
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.11 no.1
    • /
    • pp.110-123
    • /
    • 2000
  • The short-term music therapy was performed for adolescents with conduct disorder admitted to Seoul National Mental Hospital for 3 months from Jun to September, 1998. This case study focused mainly on two female patients who participated regularly in the group music therapy. The music therapy process was divided into three phases;beginning, opening up, and closing. This music therapy session consisted of three parts;hello song as beginning, various musical activities, and sound & movement activity as closing. Free musical improvisation, song discussion, musical monodrama, and sound & movement were the mainly applied techniques. Free improvisation was used to enhance, motivate, identify and contain the adolescents' feelings and ideas. Song discussion was used to convey their thoughts and to support each other. Musical monodrama was used to make them have insights into interpersonal relationships. Sound & movement was used to enhance spontaneity. It made them explore their body and voice as an expressive medium. Throughout three months period of music therapy, patient A's communication skill, socialization, and behavior areas were assessed with improvement. She could use music as a symbolic form and was able to share her feelings about herself and her family. Patient B's self-expression and cognitive areas were assessed with improvement. She became more spontaneous and could verbalize her emotions during the group session. Music as a non-verbal and therefore often a non-threatening medium wherein so much can be expressed provided two female patients an atmosphere where a sense of trust may be regained.

  • PDF

Effects of Change in Patient Position on Radiation Dose to Surrounding Organs During Chest Lateral Radiography with Auto Exposure Control Mode (자동노출제어장치를 적용한 흉부 측면 방사선검사 시 환자 위치 변화가 주변 장기의 선량에 미치는 영향)

  • Seung-Uk Kim;Cheong-Hwan Lim;Young-Cheol Joo;Sin-Young Yu
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.903-909
    • /
    • 2023
  • The purpose of this study is to compare and analyze the effect of changes in the patient's central position on the exposure dose and image quality of surrounding organs during a chest lateral examination using an Auto Exposure Control(AEC). The experiment was conducted on a human body phantom. A needle was attached to the lower part of the center of the coronal plane of the phantom, and a lead ruler was attached to the lower part of the detector so that the 50 cm point was located at the lower center of the AEC ion chamber. The exposure conditions were 125 kVp, 320 mA, the distance between the source and the image receptor was 180 cm, and the exposure field size was 14 × 17 inches. Only one AEC ion chamber was used at the bottom center, and the density was set to '0' and sensitivity to 'Middle', and the central X-ray was incident vertically toward the 6th thoracic vertebra. With AEC mode applied, the 50 cm point of the needle and lead ruler were aligned and the phantom was moved 5 cm toward the stomach (F5) and 5 cm toward the back (B5), and the dose factor was analyzed by measuring ESD. The ESD of the thyroid gland according to the change in patient center position was 232.60±2.20 μGy for Center, 231.22±1.53 μGy for F5, and 184.37±1.19 μGy for B5, and the ESD of the breast was 288.54±3.03 μGy for Center, F5 was 260.97±1.93 μGy, B5 was 229.80±1.62 μGy, and the ESD of the center of the lung was 337.02±3.25 μGy for Center, F5 was 336.09±2.29 μGy, and B5 was 261.76±1.68 μGy. As a result of comparing the average values of dose factors between each group, the difference in average values was statistically significant (p<0.01), and each group appeared to be independent. As a result of the study, there was no significant difference in the dose to the thyroid, breast, and center of the lung according to the change in the patient's central position, except for the breast (10%) when the patient moved forward about 5 cm. However, movement of about 5 cm posteriorly resulted in an average dose reduction of 23.7%. Additionally, when the patient's central position was moved to the rear, image quality deteriorated.

A Study on Control of Walking Assistance Robot for Hemiplegia Patients with EMG Signal (EMG 신호로 반신불수 환자의 보행 보조로봇 제어에 관한 연구)

  • Shin, D.S.;Lee, D.H.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.7 no.2
    • /
    • pp.55-62
    • /
    • 2013
  • The exoskeleton robot to assist walking of hemiplegia patients or disabled persons has been studied in this paper. The exoskeleton robot with degrees of freedom of 2 axis has been developed and tested for joint motion. The obtained EMG signal from normal person was analyzed and the control signal was extracted from it for convenient and automotive performance of assistance robot to help hemiplegia patient walks as normal person does. the purpose of using FES(Functional Electrical Stimulation) for hemiplegia patient's walk is to restore damaged body function by this, but this could give fatal electrical shock to patients by wrong use or cause quick fatigue in muscle by continuous stimulation. The convenient movement of hemiplegia patients with minimum muscle fatigue was looked possibly by operation of assistance robot exoskeleton using control signal. and the walking assistance exoskeleton robot seemed works more efficiently than using FES stimulator. The experiment in this study was performed based on usual motion in our life like walking, standing-up, sitting-down, and particularly feedback control system using Piezo sensor along with button switch was applied for smooth swing motion in walking. The experiment also shows that hemiplegia patients can move conveniently by using electromyogram signal of healthy leg for the operation signal of assistance robot system attached at damaged symmetrical leg.

  • PDF

Dose Characteristics of Stereotactic Radiosurgery in High Energy Linear Accelerator Proton Beam (고에너지 선형가속기에 의한 입체방사선수술의 선량특성)

  • Choi, Tae-Jin;Kim, Ok-Bae
    • Radiation Oncology Journal
    • /
    • v.10 no.2
    • /
    • pp.137-145
    • /
    • 1992
  • Three-dimensional dose calculations based on CT images are fundamental to stereotactic radiosurgery for small intracranial tumor. In our stereotactic radiosurgery program, irradiations have been performed using the 6 MV photon beam of linear accelerator after stereotactic CT investigations of the target center through the beam's-eye view and the coordinates of BRW frame converted to that of radiosurgery. Also we can describe the tumor diameter and the shape in three dimensional configuration. Non-coplanar irradiation technique was developed that it consists of a combination of a moving field with a gantry angle of $140^{\circ}$, and a horizontal couch angle of $200^{\circ}C$ around the isocenter. In this radiosurgery technique, we provide the patient head setup in the base-ring holder and rotate around body axis. The total gantry moving range shows angle of 2520 degrees via two different types of gantry movement in a plane perpendicular to the axis of patient. The 3-D isodose curves overlapped to the tumor contours in screen and analytic dose profiles in calculation area were provided to calculate the thickness of $80\%$ of tumor center dose to $20\%$ of that. Furtheremore we provided the 3-D dose profiles in entire calculation plane. In this experiments, measured isodose curves in phantom irradiation have shown very similiar to that of computer generations.

  • PDF