• Title/Summary/Keyword: path-line

Search Result 846, Processing Time 0.026 seconds

A Study on multi-channel temperature monitoring for the detection of leakage or seepage in dam body (댐 침투수 탐지를 위한 멀티 채널 온도 모니터링 연구)

  • Oh, Seok-Hoon;Kim, Jung-Yul;Park, Han-Gyu;Kim, Hyoung-Soo;Kim, Yoo-Sung
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.1211-1218
    • /
    • 2005
  • Temperature variation according to space and time on the inner parts of engineering constructions(e.g.: dam, slope) can be a basic information for diagnosing their safety problem. In general, as constructions become superannuated, structural deformation(e.g.: cracks, defects) could be occurred by various factors. Seepage or leakage of water through these cracks or defects in old dams will directly cause temperature anomaly. Groundwater level also can be easily observed by abrupt change of temperature on the level. This study shows that the position of seepage or leakage in dam body can be detected by multi-channel temperature monitoring using thermal line sensor. For this, diverse temperature monitoring experiments for a leakage physical model were performed in the laboratory. In field application of an old dam, temperature variations for water depth and for inner parts of boreholes located at downstream slope were measured. Temperature monitoring results for a long time at the bottom of downstream slope of the dam showed the possibility that temperature monitoring can provide the synthetic information about flowing path and quantity of seepage of leakage in dam body.

  • PDF

Design and Implementation of a Low-Noise SMPS for Distributed Control Systems (분산제어시스템을 위한 저잡음 SMPS의 설계 및 구현)

  • Cheong, Tai-Hyun;Park, Jong-Tae;Yu, Chong-Gun
    • Journal of IKEEE
    • /
    • v.12 no.1
    • /
    • pp.59-64
    • /
    • 2008
  • In this paper, a new efficient SMPS has been designed and implemented. It can replace the existing product that is widely used in industry. To investigate the performance of the conventional SMPS, the output voltage changes due to variations in the input voltage and the load conditions, and the ripple and noise voltages have been measured and analyzed. As a result, it has been confirmed that the noise in the conventional SMPS is severe due to the deficiency of patterns for current. This is because the conventional SMPS draw out all outputs using one transformer and the alarm logic exists in the output path. To solve this problem, the switching frequency is increased from 17KHz to 70KHz and the current patterns are fully guaranteed by separating the alarm circuit and PWM circuit as a sub-board from the main board. Measurement results shows that the output noise of the designed SMPS decreases below 32% of the conventional SMPS noise for various test conditions, and both the line and load regulations are improved.

  • PDF

Development of Practical Integral Condition Monitoring System for A Small Turbojet Engine Using SIMULINK and LabVIEW (SIMULINK와 LabVIEW를 이용한 소형 터보제트 엔진의 실용 통합 상태 진단 시스템 개발)

  • Kong, Changduk;Kho, Seonghee;Park, Gilsu;Park, Gwanglim
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.17 no.1
    • /
    • pp.80-88
    • /
    • 2013
  • In currently developed engine condition monitoring systems, most field engine maintenance engineers have difficulties to use them in fields due to complexity, unpractical use, lack of understanding, etc. Therefore a practical usable engine condition monitoring system must be needed. This work proposes a practical performance condition monitoring of a small turbojet engine through comparing between the on-line performance monitoring data and the initial clean performance data calculated by the base engine performance model. Moreover the proposed monitoring system checks the gas path components' on-line health condition through comparing the component performance characteristics between the running engine represented as a deteriorated engine or a degraded engine and the base engine performance model represented as a clean engine. The proposed condition monitoring system is coded in a friendly GUI type program for easy practical application by a commercial tool, MATLAB/SIMULINK and LabVIEW.

Variation of Undrained Shear Behavior with Consolidation Stress Ratio of Nakdong River Sand (압밀응력비에 따른 낙동강모래의 비배수전단거통 특성)

  • 김영수;정성관;송준혁;정동길
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.4
    • /
    • pp.83-93
    • /
    • 2003
  • This research, in order to study the effects of initial shear stress of anisotropically consolidated sand that has 0.558% fines, performed several undrained static and dynamic triaxial test. To simulate the real field conditions, loose and dense samples were prepared. Besides, the cyclic shear strength of Nakdong River sand under various combinations of initial static shear stress, stress path, pore water pressure and residual strength relationship was studied. By using Bolton's theory, peak internal friction angle at failure which has considerable effects on the relative density and mean effective stress was determined. In p'- q diagram, the phase transformation line moves closer to the failure line as the specimen's initial anistropical consolidation stress increases. Loose sands were more affected than dense sands. The increase of consolidation stress ratio from 1.4 to 1.8 had an effect on liquefaction resistance strength resulting from the increase of relativity density, and showed similar CSR values in dense specimen condition.

A Numerical Estimation on Extension of Marine Afforestation Area using Particle Tracking Method (입자추적기법을 이용한 바다숲 조성지의 확장에 관한 수치예측)

  • Cho, Jae-Kweon;Kim, Dae-Kweon;Lee, Moon-Ock;Oh, Tae-Geon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.6
    • /
    • pp.922-934
    • /
    • 2010
  • To arrange artificial reefs for marine afforestation effectively, tidal currents were analyzed by numerical experiments, and particle tracking based on tidal currents was carried out to clarify the path of algae spores. The experiments were conducted by the Environmental Fluid Dynamics Code (EFDC), and water column was vertically divided into five layers. Tidal current patterns were showed to be affected by main currents outside of the study area, and two circle currents were observed during the analysis of residual currents. Particle tracking lasted 15 days at three installation places where artificial reefs for marine afforestation could be deployed. According to the results of the particle tracking experiment, particle movements at the No.1 and No. 3 stations were belt types along the coastal line. The No. 2 station documented an ellipse type movement 300~500m from coast line. These results suggest that artificial reefs for marine afforestation should be installed in the belt zones at of the No. 1 and No. 3 stations, and in the ellipse zone at the No. 2 station.

Domestic Efforts for SFCL Application and Hybrid SFCL (국내 초전도 한류기 요구와 하이브리드 초전도 한류기)

  • Hyun, O.B.;Kim, H.R.;Yim, Y.S.;Sim, J.;Park, K.B.;Oh, I.S.
    • Progress in Superconductivity
    • /
    • v.10 no.1
    • /
    • pp.60-67
    • /
    • 2008
  • We present domestic efforts for superconducting fault current limiter (SFCL) application in the Korea Electric Power Corporation (KEPCO) grid and pending points at issue. KEPCO's decision to upgrade the 154 kV/22.9 kV main transformer from 60 MVA to 100 MVA cast a problem of high fault current in the 22.9 kV distribution lines. The grid planners supported adopting an SFCL to control the fault current. This environment friendly to SFCL application must be highly dependent upon the successful development of SFCL having specifications that domestic utility required. The required conditions are (1) small size of not greater than twice of 22.9 kV gas insulated switch-gear (GIS), (2) sustainability of current limitation without the line breaking by circuit breakers (CB) for maximum 1.5 seconds. Also, optionally, recommended is (3) the reclosing capability. Conventional resistive SFCLs do not meet (1) $\sim$ (3) all together. A hybrid SFCL is an excellent solution to meet the conditions. The hybrid SFCL consists of HTS SFCL components for fault detection and line commutation, a fast switch (FS) to break the primary path, and a limiter. This characteristic structure not only enables excellent current limiting performances and the reclosing capability, but also allows drastic reduction of HTS volume and small size of the cryostat, resulting in economic feasibility and compactness of the equipment. External current limiter also enables long term limitation since it is far less sensitive to heat generation than HTS. Semi-active operation is another advantage of the hybrid structure. We will discuss more pending points at issues such as maintenance-free long term operation, small size to accommodate the in-house substation, passive and active control, back-up plans, diagnosis, and so on.

  • PDF

An Effect of Electrical Interconnect in Optical Transceiver Module (광송수신 모듈 구현을 위한 전기 접속부에 관한 연구)

  • 조인귀;한상필;윤근병;정명영
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.8
    • /
    • pp.863-870
    • /
    • 2003
  • The digital transmission system entered in a RF region as digital system use IC chips of the speeder edge rate and clock speed nowadays. Optical path really was used in order to obtain the more capacity. In this paper, we described importance of electrical interconnect to get the signal integrity in optical module by simulation and experiment. 12 channel${\times}$2.5 G/ps optical parallel transmitter modules were manufactured by two different method ; access lines with microstrip and stripline type. We have clearly shown that the optical module adopting microstrip type with S$\sub$11/ $\geq$ -10 dB presents distortion but the optical module adopting stripline type with S$\sub$11/ $\leq$ : 15 dB obtains eye opening in 2.5 Gbis optical eye pattern response.

Non-linear Resistive Switching Characteristic of ZnSe Selector Based HfO2 ReRAM Device for Eliminating Sneak Current

  • Kim, Jong-Gi;Kim, Yeong-Jae;Mok, In-Su;Lee, Gyu-Min;Son, Hyeon-Cheol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.357-358
    • /
    • 2013
  • The non-linear characteristics of ON states are important for the application to the high density cross-point memory industry because the sneak current in neighbor cells occurred during reading, erasing, and writing process. Kw of above 20 in ON states, which is the writing current @ Vwrite/the current @ 1/2Vwrite, was required in cross-point ReRAM memory industry. The high current density non-linear IV curve of ZnSe selector was shown and the ALD HfO2 switching device has the linear properties of ON states and the compliance current of 100 uA. To evaluate the performance of the selection device, we connected itto HfO2 switching device in series. The bottom electrode of the selection device was connected to the top electrode of the RRAM. All of the bias was applied with respect to the top electrode of the selection device, whereas the bottom electrode of the RRAM was grounded. In the cross-point application, 1/2Vwrite and -1/2Vwrite were applied to the word-line and bit-line, respectively, which were connected to the selected cell, and a zero bias was applied to the unselected word-lines and bit-lines. The current @ 1/2Vwrite of the unselected cells was blocked by the selection device, thus eliminating the sneak path and obtaining a writing voltage margin. Using this method, the writing voltage margin was analyzed on the basis of the memory size.

  • PDF

Estimating Station Transfer Trips of Seoul Metropolitan Urban Railway Stations -Using Transportation Card Data - (수도권 도시철도 역사환승량 추정방안 -교통카드자료를 활용하여 -)

  • Lee, Mee-Young
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.38 no.5
    • /
    • pp.693-701
    • /
    • 2018
  • Transfer types at the Seoul Metropolitan Urban Railway Stations can be classified into transfer between lines and station transfer. Station transfer is defined as occurring when either 1) the operating line that operates the tag-in card-reader and that operating the first train boarded by the passenger are different; or 2) the line operating the final alighted train and that operating the tag-out card-reader are different. In existing research, transportation card data is used to estimate transfer volume between lines, but excludes station transfer volume which leads to underestimation of volume through transfer passages. This research applies transportation card data to a method for station transfer volume estimation. To achieve this, the passenger path choice model is made appropriate for station transfer estimation using a modified big-node based network construction and data structure method. Case study analysis is performed using about 8 million daily data inputs from the metropolitan urban railway.

129 GHz SIS MIXER RECEIVER FOR KOREAN VLBI NETWORK (한국우주전파관측망 129 GHz 초전도 믹서 수신기)

  • Lee, Jung-Won;Wang, Ming-Jye;Li, Chao-Te;Chen, Tse-Jun;Kim, Soo-Yeon;Lu, Wei-Chun;Kang, Yong-Woo;Shi, Sheng-Cai;Han, Seog-Tae
    • Publications of The Korean Astronomical Society
    • /
    • v.27 no.3
    • /
    • pp.71-80
    • /
    • 2012
  • We have developed superconducting mixer receivers for 129 GHz VLBI observation in Korean VLBI Network (KVN). The developed mixer has a radial waveguide probe with simple transmission line L-C transformer as a tuning circuit to its 5 series-connected junctions, which can have 125 - 165 GHz as the operation radio frequency (RF). For intermediate frequency (IF) signal path a high impedance quarter-wavelength line connects the probe to one end of symmetric RF chokes. The double side band (DSB) receiver noise of the mixer was about 40 K over 4 - 6 GHz IF band, whereas we achieved the uncorrected single side band (SSB) noise temperature of about 70 K and better than 10 dB image rejection ratio in 2SB configuration with 8 - 10 GHz IF band. Insert-type receiver cartridges employing the mixers have been under commission for KVN stations.